N663UA
Service difficulty reports · 347
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA00931Cap · missingEND CAPS MISSING FROM EEL LIGHTING AT SEATS 1B AND 1F. INSTALLED END CAPSSDR 2008UALA00456Light · inoperativeLEFT SIDE CABIN FLOOR LIGHTING INOP IN BUSS AND 1ST CLASS. REPLACED LIGHTS, OPS CHECKS GOOD.SDR 2008UALA00391Unknown · smokeCREW REPORTED SMOKE IN CABIN AND RETURN TO FIELD.SDR 2008UALA00313Engine · leakingRTFL UNDER AMBER ALERT DUE TO ELECTRICAL ODOR. REMOVED NR 2 ENGINE AFTER CONFIRMATION OF DIAGNOSTIC TEST FLT. LABEL ENGINE REMOVAL REASON AS CABIN OIL ODOR & CHRONIC HUNG START. OIL SMOKE ENTERING THROUGH THE BLEED INLETS.SDR 2007UALA05248Unknown · unknownEICAS MSG R GEN OFF DISPLAYED. GEN OFF LIGHT ILLUM. CREW COMMENTS: A-C DID NOT PICK UP AC BUS AFTER RT ENGINE STARTED.SDR 2007UALA05044Unknown · unknownFLIGHT DIVERTED DUE TO RIGHT ENGINE CORE COWL PROBLEM.SDR 2007UALA04987Pump · malfunctionedNR 1 ACMP DOES NOT COME ON LINE WHEN IN AUTO MODE AND EDP IS SWITCHED OFF.SDR 2007UALA04944Cylinder · faultyRIGHT OVERWING SLIDE CYLINDER BOTTLE BALL IS BELOW THE SPRING FORCE MECHANISM.SDR 2007UALA04943Battery Pack · dischargedEEL EXTERIOR DOOR 1R AND 2L INOP.SDR 2007UALA04942Light · inoperativeEXTERIOR EMERGENCY LIGHT AT L-1 DOOR IS INOP.
SDR 2007UALA04895Light · looseRIGHT FUSELAGE EVACUATION (EMERGENCY) LIGHT LOOSE STA 1230, STR 23R.
SDR 2007UALA04867Light · inoperativeEMERGENCY EXIT LIGHT AT LEFT AND RIGHT AFT DOORS, LWR PORTION OF LIGHT (DOOR HANDLE ILLUMINATION) IS INOP.
SDR 2007UALA04866Light · inoperativeB-ZONE LEFT SIDE FWD 2 EA EEL LIGHT STRIPS ARE INOP.
SDR 2007UALA04857Stiffener · crackedBS 246 FLOORBEAM STIFFENER CRACKED RBL 26. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED STIFFENER.SDR 2007UALA01237Blades · damagedBIRD STRIKE TO NR 1 ENGINE. ACCOMPLISHED BOROSCOPE INSP OF NR 1 ENG HPC 5TH, 6TH, 10TH AND 11TH STG BLADES PER MM 72-00-00. FOUND 1 EA 6TH STG BLADE WITH LARGE TEAR IN AREA C OF L/E BEYOND FLYBACK LIMITS, 18 EA 10TH STG BLADES WITH DAMAGE BEYOND LIMITS IN ARSDR 2007UALA00851Wire · burnedF/O`S NR 1 WINDOW & CAPT'S SIDE WINDOW HEAT INOP. FOUND WINDOW HEAT WIRES BURNT BEHIND E2-1 RACK AT CONN D4294P, REF WDM 30-41-12. CONTROL SENSOR FOR LEFT WINDOW 2 MELTED AND OTHER WIRES HAVE HEAT DAMAGE. PWR WIRE W1120-203B-12 EXTENSIVELY DAMAGED. WIRES WERSDR 2006UALA01639Light · inoperativeFWD GALLEY CROSS AISLE EEL STRIP INOP.SDR 2006UALA01393Power Supply · inoperativeEMERGENCY POWER SUPPLY AT SEAT 20FG IS INOP. REPLACED POWER SUPPLY PER MM 33-51-07 AND OPS CHECK GOOD.SDR 2006UALA01380Insert · missingLT OVERWING SLIDE DOOR ACTUATOR SQUIB SHUNT CAP MISSING INSERT. REPLACED 3SF5951-501 SHORTING CAP. OK FOR RETURN TO SERVICE.SDR 2006UALA01190Spring · shearedRIGHT DOWN LOCK SPRING ON NOSE LANDING GEAR SHEARED. REPLACED DEFECTIVE SPRING DUE TO WEAR WAS BEYOND LIMIT.SDR 2005UALA00483Adc · failedFAILURE OF F/O AIR DRIVEN COMPUTER AND ALTIMETER. RT AIR DATA COMPUTER RPL, MR41190, NO DASH, BUT S/N=88041280. A/C HAD PREVIOUS HISTORY ON 18 MAY. NO UNIT HISTORY AVAILABLE IN CIDER FOR THIS S/N, SUSPECT THIS IS 1ST REMOVAL.SDR 2006UALA01156Latch · failedLT O/W HATCH FAILS INTEGRATOR TORQUE CHECK. REPLACED LATCHES.SDR 2004UALA00939Hydraulic System · leakingFLIGHT DIVERTED DUE TO RIGHT HYDRAULIC SYSTEM QUANTITY LOSS. REPLACED RIGHT SYSTEM EDP. NO FURTHER REPORTS NEXT 20 AC CYCLES.SDR 2003UALA00575Seat Track · corrodedMAIN CABIN BETWEEN BS 785.9 AND BS 814, LBL 55, SEAT TRACK CORRODED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW SPLICE SECTION.SDR 2003UALA00569Seat Track · corrodedMAIN CABIN BETWEEN STA 774 AND 785 AND LBL 55, SEAT TRACK HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SECTION WITH SPLICE DOUBLERS.SDR 2003UALA00568Seat Track · corrodedMAIN CABIN AT STA 1197+80 LBL 89 SEAT TRACK HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPLACEMENT TRACK AND SPLICES.SDR 2003UALA00567Seat Track · corrodedMAIN CABIN SEATTRACK AT STA 654+14 RBL 89 IS CORRODED OUT OF LIMITS. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION WITH SPLICE DOUBLERS.SDR 2003UALA00566Floor Support · corrodedCORROSION OUT OF LIMITS ON FLOOR SUPPORT ANGLE AT STA 368. OTBD BY LWR AFT R-2 DOOR ON STRUCTURE. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION.SDR 2003UALA00565Frame · puncturedAFT PIT FRAME HAS 3 INCH PUNCTURE STA 1351, STR 24R TO 25R. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER REPAIR.SDR 2003UALA00484Light · inoperativeLEFT MOST FWD EMERGENCY EEL STRIP INOPERATIVE. SECURED EEL STRIP, OPS CHECK OK.SDR 2004UALA00959Warning Light · illuminatedRT PRIM HYD OVERHEAT EICAS AND LIGHT. RIGHT HYDRAULIC QUANTITY DROPPED TO ZERO. RIGHT ENGINE DRIVEN PUMP REPLACED. FAILURE DUE TO FROZEN BEARINGS, PUMP OVERHEATED DUE TO LACK OF LUBRICATION.SDR 2002UALA01453Pbe · damagedPASSENGER BREATHING EQUIPMENT DAMAGED AT CLOSET 309. REPLACED PBE.SDR 2002UALA01144Generator · defectiveON CLIMB FROM SFO RIGHT HAND GENERATOR DROPPED OFFLINE AND WAS UNABLE TO BE RESET. SUPPLEMENTAL DATA UPDATE REPLACED RIGHT GENERATOR.DEFECTIVE PARTS - FOUND DIODE, ROTOR AND EXCITER FAILED.SDR 2001UALA02281Oxygen Mask · defectiveCAPTAINS OXYGEN MASK ASSEMBLY HEADBAND LEAKS AND WILL NOT COLLAPSE AROUND HEAD. MASK FAILED DUE TO NORMAL WEAR AND TEAR.SDR 2001UALA01435Warning System · activated"MAIN BATT CHGR" MESSAGE DISPLAYED ON EICAS.SDR 2001UALA00753Card · faultyRT ENG OVHT EICAS MESSAGE. FOLLOWED FLIGHT MANUAL PROCEDURE, REDUCED THROTTLE, MESSAGE REMAINED. SHUTDOWN ENGINE. *S/D* THE EICAS RT ENG OVHT MSG WITHOUT DISCRETE LIGHT ON WAS CAUSED BY AFOLTS CARD M10274. THE CARD WAS REPLACED AND SYSTEM CHECKED OK. SHOSDR 2000UALA00770Oven · fireFIRE IN MID GALLEY OVEN, LOCATION R31 RECON-OVEN. HAND HELD EXTINGUISHER USED. DIVERTED PHL. OVERWEIGHT LANDING. *S/D* FOUND PAPER BURNED BETWEEN TOP OF OVEN RACK AND EXHAUST FAN OPENING. THE OVEN WAS REMOVED AND THE ELECTRICAL CONNECTORS WERE INSPECTED.SDR 2000UALA00524Window · unsecureREJECTED TAKEOFF AT 100 KT DUE TO FLIGHT DECK WINDOW PROBLEM. *S/D* AIRCRAFT INSPECTED FOR HIGH SPEED RTO. NO DISCREPENCIES FOUND. NUMBER 1 SLIDING WINDOW WAS APPARENTLY NOT FULLY SECURED PRIOR TO DEPARTURE.SDR 2000UALA00107Video Unit · odorSTRONG ELECTRICAL SMELL IN MID CABIN. NO SMOKE OBSERVED, UNABLE TO CLEAR SMELL FROM CABIN. DIVERTED OMA. *S/D* TRACED SMELL TO SEAT 10C VDU. ISOLATE WIRING TO MONITOR ASSY AND SEAT ELEC BOX. CAPS AND SECURE CABLES. (DEFERRED) REPLACED VDB (VIDEO DISTRIBSDR 2000UALA00034Snubber · defectiveFORWARD SERVICE DOOR 1 RIGHT REQUIRES INTERIOR HANDLE TO BE PUSHED FULLY UP TO CLOSE. *S/D* MAINTENANCE FOUND THE INTERIOR HANDLE NOT HOLDING THE CORRECT POSITION WITH THE DOOR OPEN. THE SPRING HYDRAULIC SNUBBER WAS DEFECTIVE. REPLACED SNUBBER PER MM 52-11SDR 98UAL900554Oven · fireSMOKE REPORTED FROM OVEN NR 305, FLT ATTENDANT DISCHARGED HALON FIRE EXTINGUISHER INTO OVEN. CB PULLED. CAUSE DUE TO PLASTIC AND PAPER MELTING AND OVERHEATING IN THE FAN AREA ON THE BAFFLE. OVEN REPLACED.SDR 98UAL900392Light · malfunctionedAIRCRAFT RETURNED TO BLOCKS WITH REPORT OF LEFT AFT EXTERIOR EMERGENCY LIGHTS ILLUMINATED. *S/D* PERFORMED EXTERIOR EMERGENCY LIGHTS TEST PER MM. NO PARTS REPLACED, NO FURTHER REOCCURRENCE OF DISCREPANCY.SDR 98UAL900154Indication · malfunctionedAFTER LANDING GEAR EXTENSION, EICAS GEAR DISAGREE AND TAIL SKID WARNINGS. GEAR AND TAIL SKID WARNING LIGHTS ILLUMINATED ON LANDING GEAR INDICATION PANEL BUT HAD ALL GEAR DOWN LIGHTS GREEN. RECYCLED LANDING GEAR AND GOT ALL NORMAL INDICATIONS WITH NO ABNORMALSDR 97UAL900335Circuit Breaker · failedAIRCRAFT RETURNED TO SFO AFTER BOTH UTILITY BUS OFF LIGHTS CAME ON DURING TAKEOFF. *S/D* LEFT GENERATOR CONTROL BREAKER AUXILIARY CONTACT FAILED. REPLACED LEFT AND RIGHT GENERATOR CONTROL BREAKERS.SDR 97UAL900132Target Sensor · out of adjustTHE LEFT OVERWING EXIT DOOR REQUIRED 12 POUNDS OF FORCE TO OPEN DURING A MAINTENANCE CHECK. THE TARGET SENSOR WAS MISALIGNED IN THE INBOARD CORE OF THE DOOR. ADJUSTED TARGET SENSO, THE DOOR THEN OPENED FREELY AND THE ACTUATORS OPERATED PER DESIGN.SDR 97UAL900070Surge Valve · defectiveTHE APU SHUTDOWN PRIOR TO ENGINE START. THE APU WOULD NOT RESTART. *S/D* THE SURGE CONTROL VALVE WAS DEFECTIVE AND REPLACED, OPERATIONS CHECK NORMAL. NO OTHER APU DISCREPANCIES HAVE OCCURRED SINCE THIS INCIDENT.SDR 96UAL900124Lamp · inoperativeTHE RIGHT NR 6 SLIDE LIGHT IS INOP. REPLACED LAMP, OPS CHECK NORMAL.
Back to N663UA