N665UA
Service difficulty reports · 373
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N665UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N665UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011033001518Pressure Switch · faultyCTR AUX OVRD PUMP LOW PRESS LIGHT ON, SW ON, EICAS MSG CTR L-R FUEL PUMP. POSITION 7 (7=L CTR,11=R CTR). VERIFIED RIGHT PUMP LO PRESSURE LIGHT NORMAL OPS PER MEL. LEFT CTR PMP INOPED. NEED TO TROUBLESHOOT, LEFT PUMP APPEARS TO BE WORKING, ON RETURN TO BLOCSDR UALA2011032801467Outflow Valve · faultySTATUS MESSAGE CABIN ALT AUTO 1 UNABLE TO CLEAR. BITE SHOWING AC MOTOR. ACCMP'D BITE OF NR 1 CABIN PRESSURE CONTROLLER PER MM. FAULT SHOWS "SELECTOR". REPLACED CABIN PRESSURE SELECTOR PANEL M13 PER MM, OPS CKD GOOD. STATUS MSG RETURNED. ITEM HAS SEVERAL SDR UALA2011021800839Cap · out of toleranceA-T DISC LIGHT ON P1-3 PANEL INOP. REPLACED LIGHT SWITCH CAP, OPS CHECKED OKAY.SDR UALA2011020700630Wire · looseSEAT 1B HAS LOOSE WIRE AND PLACARD OFF SEAT ON FLOOR NEXT TO SEAT. REPLACED EMERGNECY LIGHT ASSY. OP CHECKED GOOD.SDR UALA2011020200561Light · unsecureEXIT SIGN HANGING BY WIRES SEAT 1B. SECURED 1B EMERGENCY STRIP. CKS OK.SDR UALA2011013100526Shutoff Valve · fluctuatesDURING CLIMB & DESCENT RT DUCT PRESSURE FLUCTUATES BETWEEN 15-35 PSI. REPLACED NR 2 ENG PRSOV. RAN ENG AND LEAK CKD. OPS CHECKED NORMAL.SDR UALA2011011000144Wire · looseSEAT 1B HAS LOOSE WIRES AT THE BOTTOM THAT LIGHT THE EMERGENCY EXIT PATH FLOOR MARKINGS. REPLACED SEAT EMERGENY LIGHT. OPS OKAY.SDR UALA2011010300011Connector · dirtySTATUS MESSAGE "RT IDG VALVE". FOUND 1K OHMS FROM (K1032) PIN 13 TO IDG OIL COOLER FAN AIR S-O VALVE PIN 'B' ON (D11046). CORRECTED BY CLEANING AND INSPECTING FIRE-WALL CONNECTOR (D4216P). NOW WIRING RINGS OK, OPS CHECKED GOOD WITH ENGINE RUN, NO FAULTS.SDR UALA2010121304534Light · dislodgedEMERGENCY EXIT LIGHT BROKE OFF OF SEAT 1B. INOPERATIVE IAW MEL. RESECURED LIGHT ASSY BUT LIGHT IS INOPERATIVE. REPLACED EMERGENCY LIGHT IAW MM. EMERGENCY LIGHT OPS CHECK OK.SDR UALA2010113004407Fan · odorELECTRICAL ODOR IN CABIN, FLIGHT DIVERTED. REPLACED RECIRCULATION FAN AND FILTER. RAN ENGINES FOR 5 MIN NO ODORS NOTED. ACFT RETURNED TO SERVICE.SDR UALA2010110304089Light · brokenEMERGENCY LIGHT ON SIDE OF SEAT 17B BROKEN IN HALF. REPLACED EMERGENCY LIGHT. CHECKS GOOD.SDR UALA2010102203901Blocker Door · out of positionNR 1 ENG LT REVERSER OTBD SIDE AT 12 O'CLOCK POSITION BLOCKER DOOR IS HANGING DOWN. INSTALLED BLOCKER DOOR AT POSITION 11:00 PER AMM. REPLACED DAMAGED BLOCKER DOOR PER MM. OPS CHECKS OKAY.SDR UALA2010101203795Gcu · faultyCREW REPORTS ON TAXIOUT GOT RT ENG IDG VALVE EICAS MESSAGE. VALVE LOCKED OUT PER MEL 7521D. ACP COMPONENT RESISTANCE CHECK AND OPERATIONAL TEST WITH EXTERNAL AIR USING MIPS PW 4000 IDG AOC TS. VALVE OPERATED WITH NO MSG. ACCOMPLISHED BLOCK 6 POWER RUN. VERISDR UALA2010092903596Lens · brokenSEAT 25A EMERGENCY PATH LIGHT BROKEN OFF. REPLACED LENS. OPS OK.SDR UALA2010091303408Light · missingEMERGENCY LIGHT MISSING ON SIDE OF SEAT 1A. INSTALLED EMERGENCY LIGHT.SDR UALA2010091303407Light · missingEMERGENCY LIGHT STRIP ON SIDE OF SEAT 2H MISSING. INSTALLED EMERGENCY LIGHT.SDR UALA2010082503134Module · faultyCAPT PITOT HEAT ON OVERHEAD PANEL DIM WITH SWITCH IN BRIGHT. DIM BRIGHT FUNCTION INOP. LIGHT DIM ONLY, PITOT HEATER SYS OPERATES NORMALLY. NEEDS CAP AND BASE ASSY. REPLACED LIGHT CAP MODULE. DIM BRT TEST AND PITOT HEAT TEST NORMAL.SDR UALA2010081602981Switch · intermittentAFT PIT SYS LATERAL RAILS INOP ELECTRICALLY. FOUND FWD LATERAL RAILS ELECTRICALLY INTERMITTENT REPLACED RELAYS K292, K294, K296, NO HELP. SWAPPED TDO RELAYS, NO HELP NEED TO CONTINUE. T-S FOUND EIGHT DIRECTION SELECTOR SWITCH INTERMITTENT. REMOVED AND REPLSDR UALA2010080902885Exciter · malfunctionedAPU NO START 3 ATTEMPT SWITCH FAULT LIGHT. REPLACED APU IGNITER AND IGNITION EXCITER AS PER MM, OPS CHECKED GOOD.SDR UALA2010080502846Sense Line · damagedFOUND AIR SENSE LINE DAMAGED ON LT SIDE OF NR 2 ENG TURBINE CASE AT STARTING AT APPROX 9 O'CLOCK POSITION, LINE IS RIGID AND APPROX 4' IN LENGTH. REPLACED WITH NEW SENSE LINE. SAFTIED AND SECURED.SDR UALA2010071302497Light · unsecureEMERGENCY EVAC LIGHT POPPED OUT AND HANGING BY WIRE ON SIDE OF 2H. SECURED EMERGENCY PATH LIGHT ON SEAT 2H & OP CHECKED.SDR UALA2010070802429Indicator · faultyFLAP INDICATOR SPLIT. FLAPS AT ZERO, VISUALLY VERIFIED, FLAP INDICATOR INDICATES LT AT ZERO, RT AT 1. PROBLEM WITH RIGHT SIDE INDICATOR: STICKS AT 1 DEGREE. OPERATED FLAPS THRU COMPLETE RANGE TO VERIFY OPERATIONS. NORMAL OPS. REPLACED INDICATOR, NO HELP.SDR UALA2010070602417Actuator · faulty'L PACK INOP' LIGHT ON. EICAS MSG 'L PACK TEMP' DISPLAYED. LIGHT DID NOT EXTINGUISH WHEN 'STAND BY' SELECTED. 'RESET' PUSHED, LIGHT EXTINGUISHED THEN WENT ON. CREW COMMENTS: SEEMS TO WORK NORMALLY IN STANDBY. REPAIRED LEFT RAM AIR INLET ACTUATOR. OP CHECSDR UALA2010070602410Actuator · faultyLEFT PACK CONTROLLER FAULTS RAM AIR INLET ACTUATOR. REPLACED LEFT RAM AIR INLET ACTUATOR. RAN PACK, OP CHECKS NORMAL.SDR UALA2010062102190Skin · damagedLT WING NR 1 L/E SLAT DAMAGED. REMOVED SLAT AND ROUTED TO SHOP 321. REPLACED NR 1 L/E SLAT IAW MM.SDR UALA2010061802152Valve · faultyRT ENG HPSOV EICAS AND RT ENG BLEED LIGHT AFTER ENG START W-BLEED SWITCH OFF. REPLACED HPSOV AND HP CONTROLLER. HPSOV IS ACTIVATED FOR TEST. ACP'D HIGH PWR RUN IAW JRH, NR 2 BLEED OPS CK GOOD, NO FAULTS NOTED. BLEED LIGHT DID NOT COME ON.SDR UALA2010060701982Pump · leakingNR 2 ENGINE DRIVEN PUMP IS LEAKING HYDRAULIC FLUID. REMOVED & REPLACED LEAKING ENGINE DRIVEN PUMP. OPS NORMAL.SDR UALA2010060701970Receptacle · failedGROUND POWER RECEPTICAL FAILED NO-GO GAUGE TEST. UNABLE TO ACP DURING A-CK VISIT. ORDERED RECEPTACLE. PART NOT STOCKED HNL. REPLACED RECEPTACLE. TASK COMPLETED.SDR UALA2010060101871Light · unsecureSEAT 2H LIGHT ON SEAT SIDE OUT. EMERGENCY LIGHT STRIP NOT SECURE ON SEAT. SECURED EMERGENCY LIGHT STRIP.SDR UALA2010060101866Wire Harness · shortedEMERGENCY LIGHTS ON LT SIDE OF FIRST CLASS IS INOP. FOUND SEAT HARNESS AT SEAT 4AB SHORTED. NO SEAT HARNESS AT HNL. REPLACED HARNESS, OPS OK.SDR UALA2010052001707Light · missingEMERGENCY LIGHT ASSY MISSING AT:1B FWD, 5H FWD, 2B AFT, AND 2H AFT. REPLACED MISSING EMERGENCY LIGHT ASSY: 1B FWD, 5H FWD, 2B AFT, AND 2H AFT, CKD NORMAL ON GROUND.SDR UALA2010050701561Light · damagedSEAT 1B EMERGENCY LIGHT (1 EA) DAMAGED. REPLACED EMERGENCY LIGHT AT 1B. OPS CKS OK.SDR UALA2010042901437Unknown · unknownDURING CONTROL CHECK EXPERIENCED A HYD BUMP WHEN RELEASING AFT AND FULL FWD ELEVATOR. BUMP IN CONTROL COLUMNS IS FELT AFTER RELEASING COLUMN FROM FULL NOSE UP OR FULL NOSE DOWN POSITION. ACP'D CK AND INSPECTED PULLYS AND CABLES NO IRREG FOUND. POSSIBLY BUMP FSDR UALA2010041201230Wire Harness · damagedEMERGENCY LIGHT INOP AT SEAT 3HJ AFT LAMP. NEEDS SEAT HARNESS, AFT EMERGENCY LAMP CONNECTOR BROKEN. REPLACED HARNESS, CHECKS GOOD.SDR UALA2010041201229Wire · damagedFLOOR EMERGENCY LIGHT STRIP INOP AT LT LAV, BEHIND SEAT ROW 41AB. 2 EA LAMPS INOP ADJACENT TO EACH OTHER. FOUND EMERGENCY LIGHT WIRING UNDER SEAT 41AB CUT AND ENDS CAPPED AND STOWED. REPAIRED WIRING AND SEAT 41 AB AND LAV EMERGENCY LIGHT, OP CHECK GOOD.SDR UALA2010041201228Lamp · inoperativeEMERGENCY LIGHT INOP AT SEAT 29 HJ. RELAMPED, OPS CHECK GOOD.SDR UALA2010041201227Lamp · inoperativeEMERGENCY LIGHT INOP AT SEAT 20 HJ. RELAMPED, OP CHECKS GOOD.SDR UALA2010022500705Gcu · faultyACFT WON'T SWITCH TO APU GENERATOR POWER. NO TIME TS, TRIED RESETS NO HELP. REPLACED APU GCU. RAN APU AND POWER TRANSFERRED NORMALLY. APU GENERATOR VOLTS AND FREQ NORMAL AND ONLINE.SDR UALA2010022200660Starter · faultyCREW REPORTS RT ENG START VALVE OPENED AND LIGHT EXTINGUISHED BUT NO ENGINE ROTATION. ALSO GND CREW STATED SMOKE FROM ENG DURING START ATTEMPT. REPLACED STARTER AND STARTER SHUTOFF VALVE.SDR UALA2010021500588Transmitter · faultyCREW REPORTS L ENG OIL PRESSURE IS AT 400PSI ALL OTHER INDICATIONS NORMAL. FLT CREW NOTED 400 PSI AT CLIMB POWER ONLY. READ NORMAL AND MATCHED NR 2 ENGINE AT ALL OTHER POWER SETTINGS INCLUDING DESCENT AND IDLE. IN PROCESS OF REPLACING OIL PRESS TRANSMTR NR 1 SDR UALA2010021500565Light · missingEMERGENCY LIGHT STRIP MISSING ON SEATS 1AB, 2AB, 4AB AND 6AB. (1EA PER SEAT). REPLACED MISSING EMERGENCY LIGHT STRIPS, CHECKS OK.SDR UALA2010011800207Transmitter · faultyFLAP-SLAT ELEC LIGHT INTERMITTENT ON TAXI IN. UNABLE TO VERIFY THE PROBLEMS, REPLACED FSEU AS PRECAUTION AND SYS CHECKED NORMAL. PROBLEM RECURRED. ACCOMPLISHED BITE ON FSEU AND HAD M489 FAULT. RPLC'D NR 8 FLAP POSITION TRANSMITTER. SYS CHECKS OK AT THE PRSDR UALA2010011200147Battery Pack · faultyEMERGENCY LIGHTS INOP LT SEAT ROWS 1-6, FWD GALLEY FLOOR TRACKS 2EA AND DR 1L LWR EXIT SIGN. REPLACED BATTERY PACK. BATTERY PACK NO HELP. FOUND L901 SHORTED, DISCONNECTED EMERGENCY LIGHT STRIP AT DR 1L LAV. REPLACED EMERGENCY LIGHT STRIP. OPS CHECKED NORSDR UALA2010011100137Actuator · faultyFLAP DISAGREE MSG. FOUND "ALT FLAP PWR" CB POPPED. RE-SET AND SYS OP NORMAL. FOUND FLAP ROT ACT OVERLOAD IND ON ACT NR 1, NR 3 AND NR 8 POPPED. REPLACING ALL 3 ACT. NR 8 REPLACED. STARTING NR 1. REPLACED NR1 T-E ROTARY ACTUATOR. REPLACED NR 3 ROTARY ACTUASDR UALA2009122103951Switch · out of positionT/E FLAP DISAGREE. FLAP OVERRIDE SWITCH IN OVERRIDE. REPOSITIONED SWITCH. PERFORMED FSEU BIT. NO FAULTS. RAN FLAPS ON GROUND, NO FAULTS. LUBED TRAILING FLAPS. SYS GROUND CKS OKAY. NO PREVIOUS HISTORY.SDR UALA2009121603897Pca · malfunctionedWHEN ACCOMPLISHING FLIGHT CONTROL CHECK, ELEVATOR CHATTERS. DOES NOT FEEL LIKE CONTROL COLUMN PROBLEM, POSSIBLY HYDRAULIC OR FLT CONTROL PROBLEM, PER CREW. REPLACED LT ELEVATOR CENTER SYSTEM PCA. LEAK CHECK AND OPS CHECK GOOD.SDR UALA2009112303654Gcu · malfunctionedRT GEN FIELD MAN RESET LIGHT IS ON. REPLACED GCU, OPS CHECKS GOOD.SDR UALA2009112303652Oxygen Mask · inoperativeFIRST OBSERVERS O2 MASK MIC DOES NOT TEST. THE 1ST OBSERVERS SEAT INOPERATIVE. REPLACED O2 MASK ASSY.SDR UALA2009112303651Stowage Box · faultyCAPT O2 MASK MIC NOT WORKING. REPLACED AUDIO ACC UNIT, NO HELP. MASK STORAGE BOX BAD FROM STOCK, SWAPPED OBSERVERS WITH CAPT'S MASK BOX UNIT, ALL CHECKS OK.SDR UALA2009111703584Engine · separatedCREW REPORT: LEFT ENGINE WOULD NOT SHUTDOWN WITH FUEL CONTROL SWITCH, PULLED FIRE HANDLE TO SHUT DOWN. FOUND NR 1 ENG, INTERMEDIATE PRS CHECK VLV SEPARATED FWD SIDE. LOW STAGE HOT AIR DAMAGED MULTIPLE WIRES UNDER VLV ON WIRE BUNDLES "W3506"AND "W3538" BELON
Back to N665UA