N666UA
Service difficulty reports · 280
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N666UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N666UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011042101932Controller · failedNR 2 ENG PRC FAILED HEALTH CHECK STEPS 5Q THRU U. REMOVED AND REPLACED PRC VALVE ON THE NR 2 ENG IAW B767-300 AMM. OPS CHECK GOOD. USED OHM METER 13230064 CAL DUE DATE 08-05-2011.SDR UALA2011041201765Sliding Window · delaminatedF-O SLIDING WINDOW DELAMINATING. CAPTAIN IS AGREEABLE TO FLY ONE LEG TO TPA DUE TO EXTENSION OF LIMITS IN LEGEND. REMOVED AND REPLACED FO NR 2 SLIDING WINDOW WITH OVERHAULED UNIT & ADJUSTED IAW B767-300MM ON PEMCO NR 2542N00042.SDR UALA2011031701295Slide · unwanted deployRT OVERWING SLIDE DEPLOYED BUT NOT INFLATED AND RT OVRD SPOILER ACTUATOR FIRED 2ND TIME. SECURED SLIDE AND REPLACED SQUIBS PER MM. ACP RII OF RT OVERWING SLIDE SQUIBS INSTALLED PER MM. REPLACED ACTUATOR. RETURNED ESCAPE SLIDE SYSTEM TO NORMAL PER MM. ALL PSDR UALA2011031701290Slide · unsecureLT OVERWING SLIDE HAS LOOSE LACES. REPLACED LT OVERWING SLIDE IAM AMM. ACCOMPLISHED INSPECTION OF SLIDE INSTALLATION MM.SDR UALA2011031401204Light · missingAFT EEL LIGHT ON SEAT 5J IS MISSING. REPLACED LIGHT. CHECKS GOOD.SDR UALA2011022800976Slide · low pressureCABIN CREW DEP CHECK, AT START OF BOARDING 2L DOOR ESCAPE SLIDE PRESSURE FOUND LOW. REPLACED 2 LEFT DOOR SLIDE ASSY.SDR UALA2011020700643Computer · faultyRT EICAS COMPUTER STATUS MESSAGE RT EICAS COMPUTER INOPERATIVE. REPLACED RT EICAS COMPUTER IAW MM. CHECKED OPS PROGRAM IAW IPC. UNIT CHECKED OK AT THIS TIME.SDR UALA2011012400400Power Supply · failedCEILING MOUNTED EXIT SIGN INOP AT ROW 17 RT AISLE. REPLACED POWER SUPPLY M1209, OP CHECK NORMAL.SDR UALA2011011200192Feeder Cable · disconnectedIN FRONT OF SEATS 21DEF FLOOR EMERGENCY LIGHT INOPERATIVE. RECONNECTED AT FEEDER CABLE, CHECKS GOOD.SDR UALA2011011200191Feeder Cable · disconnectedLEFT MID LAV FLOOR EMERGENCY LIGHT INOPERATIVE. RECONNECTED FEEDER CABLE, CHECKS GOOD.SDR UALA2011011200190Connector · unsecureSEAT 20AB EMERGENCY LIGHT INOPERATIVE. SECURED UNDER SEAT CONNECTOR, CHECKS GOOD.SDR UALA2011011200189Battery Pack · faultyFWD GALLEY FLOOR EMERGENCY LIGHT INOPERATIVE. REPLACED FWD GALLEY EMERGENCY LIGHT ASSY AND BATTERY PACK, CHECKS GOOD.SDR UALA2011010600079Light · brokenSEAT 29B SIDE EMERGENCY LIGHT BROKEN. REPLACED ASSY. OPS OK.SDR UALA2010122704735Light · missingEMERGENCY LIGHT MISSING AT SEAT 1B. REPLACED LIGHT.SDR UALA2010122704734Battery Pack · inoperativeEMERGENCY LIGHTS INOP RT ROWS 1-6. REPLACED BATTERY PACK.SDR UALA2010122704733Light · looseEMERGENCY LIGHT STRIP TORN OFF 5HJ. 1 STRIP TORN, 1 IN PLACE. INSTALLED EMERGENCY LIGHT STRIP AT 5 HJ. CKS OK.SDR UALA2010122204685Pump · faultyLEFT CENTER AUX TANK OVERRIDE PUMP. REPLACED LT OVERRIDE & JETTISON PUMPS IAW MM. DID NOT REPLACE SHUTOFF SLEEVES, VERIFIED THAT THEY WERE 4 WINDOW STYLE.SDR UALA2010111604243Generator · faultyAPU GENERATOR FAILED AT DEPARTURE. REPLACED GENERATOR AND GCU, OP CHECKS NORMAL.SDR UALA2010111604242Light · missingEMERGENCY LIGHTS MISSING SEATS 1H, 5H. REPLACED EMERGENCY LIGHTS SEATS 1H, 5H, CHECKED GOOD.SDR UALA2010110104043Light · inoperativeEMERGENCY LIGHT INOP ON SEAT 5H AFT. REPLACED LIGHT ASSY, CHECKED NORMAL ON GROUND.SDR UALA2010102103897Pressure Switch · faultyRUDDER RATIO LIGHT ILLUMINATED IN FLIGHT. EICAS MESSAGE RUDDER RATIO DISPLAYED. REPLACED LEFT ELEC. HYD PRESSURE SWITCH S27 PER MM. ACP OPS CHECKED PER MM. CHECKS OKAY, NO FAULTS & NO MESSAGES.SDR UALA2010101203802Light · brokenSEAT 1B EMERGENCY LIGHT BROKEN OFF. REPLACED LIGHT ASSY. OPS OK.SDR UALA2010092703570Wire · disconnectedAT SEAT 1H, SEAT MOUNTED EMERGENCY STRIP INOPERATIVE. WIRES HAVE PULLED OUT OF THE CONNECTOR FOR THIS AFT EMERGENCY LIGHT. REPLACED EMERGENCY LIGHT ASSY AT 1H.SDR UALA2010091703468Processor · malfunctionedBOTH COCKPIT AND FUELING PANEL GAUGES QUANTITIES FLUCTUATE. FUELERS USED THE STICKS TO VERIFY. REPLACED FQIS IAW MM. OPS NORMAL.SDR UALA2010090803325Wire Harness · missingSEAT 1AB ONE EMERGENCY LIGHT MISSING. SEAT EMERGENCY LIGHT CABLE END FITTING RECEPTACLE MISSING UNABLE TO ATTACH EMERGENCY LIGHT TO CABLE. REPLACED CONNECTOR AND SEAT EMERGENCY LIGHT LAMP. OPS CHECK OKAY.SDR UALA2010062102162Light · unsecureEMERGENCY EXIT LIGHT STRIP AT 1B NEEDS TO BE REATTACHED. SECURED LIGHT ASSY, TESTS NORMAL.SDR UALA2010061702130Light · separatedSEAT 2H EMERGENCY LIGHT IS SEPARATED FROM IT'S MOUNT. SECURED LT STRIP TO SEAT & OP CHECKED.SDR UALA2010060401952Light · missingREFLECTIVE STRIP ON SIDE OF SEAT 2H HAS FALLEN OFF PIECE IN COCKPIT. REPLACED MISSING EMERGENCY LIGHT ON SEAT 2H.SDR UALA2010060101863Light · missingF-C PAX SEAT 2H AFT EMERGENCY LIGHT ASSY MISSING. REPLACED PAX SEAT AFT EMERGENCY LIGHT ASSY AND OPS CKD GOOD.SDR UALA2010052801851Outflow Valve · faultyCREW REPORTS ON TAXIOUT, GOT FWD EQUIP VALVE EICAS MSG. CYCLED CB B11 AND NO HELP. CYCLED EQUIP COOLING SELECTOR ON OVERHEAD, CONDITION NORMAL. VERIFIED 3-4 TIMES, UNABLE TO FAULT SYS. NO EICAS MSG OR IND LIGHT ILLUMINATED. REPLACED FWD OVERBOARD EXHAUST VALSDR UALA2010052101721Lamp · unsecureEMERGENCY LIGHTING STRIP AT SEAT 2H IS COMING OFF. SECURED LAMP AT ROW 2 AND FOUND ROW 1 EMERGENCY LAMP TORN OFF. REPLACED LAMP AT ROW 1, OP CHECKS GOOD.SDR UALA2010051901692Light · looseEMERGENCY LIGHT STRIP LOOSE FIRST CLASS 2H. SECURED LIGHT ASSY.SDR UALA2010051901691Light · missingSEAT MOUNTED EMERGENCY LIGHT IS MISSING ON SEAT 2J. REPLACED EMERGENCY STRIP, OPS CHECK OK.SDR UALA2010051001569Light · obstructedAFT RT LAV EMERGENCY LIGHT COVERED BY CARPET LT WORKS OK. TRIM CARPET AS NECESSARY. LIGHT NOW CLEARLY SEEN.SDR UALA2010041401262Battery · dischargedPRE DEPT FOUND APU DOOR STATUS MSG. RESET DOOR NUMEROUS TIMES. DOOR STUCK OPEN. SUSPECT ACTUATOR. DOOR SECURED CLOSED IAW MEL. REPLACED INLET DOOR ACTUATOR, NO HELP. DOOR DOESN'T OPEN, CRANKED OPEN MANUALLY & REMOVED CONNECTOR PLUG APU, STILL NO CRANK. CLOSEDSDR UALA2010033001059Isolation Valve · faultyRT ISLN VALVE LIGHT ON WITH SWITCH IN OR OUT. VALVE DEEMED DEFECTIVE. REPLACED RIGHT ISOLATION VALVE. OPS ARE GOOD.SDR UALA2010031900917Light · inoperativeRIGHT MAIN GEAR DOWN INDICATOR LIGHT INOP. REPLACED LIGHT ASSEMBLY. AS PRECAUTION PERFORMED PSEU LANDING GEAR SYSTEM NR 1 AND NR 2 AND SYSTEM TEST NORMAL.SDR UALA2010012500284Light · missingSEAT 1B FWD EMERGENCY LIGHT MISSING. REPLACED SEAT 1B EMERGENCY LIGHT STRIP. CHECKS OK.SDR UALA2010011800224Unknown · odorHEAVY RUBBER ODOR IN AFT CABIN NEAR SEAT 25 & AFT. TURNED OFF BOTH UTILITY ON SHORT FINAL. IAW CAPTAIN THE BURNED ODOR WAS NOTICED ON THE FLIGHT DECK. IAW THE F/A THE ODOR WAS ON THE RT SIDE OF THE CABIN AND DISSIPATED AFTER CAPTAIN TURNED OFF THE UTILITY BUSSDR UALA2010010700097Shutoff Valve · malfunctionedL ENG HPSOV ON AND BLEED LIGHT ON. RETARDED THROTTLES TO IDLE. GOT LT ENG HPSOV EICAS MSG AND OVERHEAD PANEL BLEED LIGHT ILLUMINATED. SECURED LT HPSOV CLOSE POSITION. REPLACED HPSOV. OP CHECKS NORMAL.SDR UALA2010010400055Controller · malfunctionedDUCT PRESS APPROX 35L-20R IN CLIMB. REMAINS SPLIT 20L-10R IN CRUISE 350 EPR 1.17. RAN BITE CHECK ON AIR SUPPLY BITE MODULE, FOUND FAULTS ON PRV AND PRV CONTROL. REPLACED PRV AND PRV CONTROL. OP CHECKS NORMALSDR UALA2009122103937Lamp · brokenEMERGENCY LIGHT BROKEN AT SEAT 1A. LAMP FOUND DAMAGED. REPLACED LAMP. CHECKS OK.SDR UALA2009121103814Light · unsecureSEAT 1B EMERGENCY LIGHT DETACHED SECURED LIGHT STRIP AND OP CHECK LIGHT.SDR UALA2009120103708Light · missingSEAT 6H EEL LT MISSING. REPLACED EEL LIGHT STRIP AT 6H. TESTED OKAY.SDR UALA2009111603545Computer · faultyLOWER EICAS SCREEN WENT TO ALL BLUE COLOR. WORKS NORMAL ON RIGHT COMPUTER. REPLACED RT EICAS COMPUTER. ACP SOFTWARE LOAD. OPS CHECK OKAY.SDR UALA2009110403419Shutoff Valve · failedLEFT DUCT PRESSURE FLUCTUATES BETWEEN 25 TO 40 PSI ON DESCENT. FOUND PRSOV FAILED HEALTH CHECK. REPLACED PRSOV, OPS CHECKS GOOD.SDR UALA2009093003079Oven · dirtyAT DEPARTURE CREW REPORTS BURNING SMELL IN 1ST CLASS. FOUND SEVERAL LIGHTS INOP IN NEED OF BALLAST P2511. FOUND FWD GALLEY WARMING OVENS ON & EXTREMELY HOT WITH FOIL BREAD BAG INSIDE. AFTER OVENS OFF FOR 1 HR SMELL DISSIPATED. ODOR WAS STRONGEST AT MED 1LSDR UALA2009092202989Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED ON UPPER FLANGE BS 287, LBL 20 TO RBL 15. MAJOR REPAIR ACCOMPLISHED. CORROSION FOUND TO BE OUT OF LIMITS. DAMAGED SECTION OF FLOORBEAM REMOVED BETWEEN LBL 32 TO RBL 88. FABRICATED & INSTALLED A REPAIR T-ANGLE, SPLICE PLATE, ANSDR UALA2009092102966Skin · crackedNR 2 ENG PYLON SIDE SKIN AT PANEL 446BL UPPER FWD CORNER IS CRACKED. MAJOR REPAIR ACCOMPLISHED: STOP DRILL CRACK AND INSTALLED DOUBLER REPAIR.SDR UALA2009092102965Trigger · out of positionLEFT OVERWING SLIDE BOTTLE TRIGGER CABLE BALL IS OUTSIDE SPRING RETAINER. INSTALLED NEW LT OVERWING SLIDE BOTTLE.