N668HH
Service difficulty reports · 135
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N668HH' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N668HH' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA2023050129001Lamp · inoperativeLH FORWARD OF WING EMERGENCY LIGHT INOP-C/A-RAR LH FWD OF WING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20230404001Lamp · inoperativeLH FWD FUSELAGE EMERGENCY LIGHT INOP.-C/A-REMOVED AND REPLACED LH FWD EMERGENCY LIGHT LAMP IAW AMM 33-50-10 OPS CHECKS GOOD.SDR SIMA20230329001Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-RAR THE LH OVERWING EMERGENCY LT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. END.SDR SIMA20230325001Lamp · inoperativeLH FORWARD WING EMERGENCY LIGHT INOP-C/A-RAR LH FORWARD WING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. END.SDR SIMA20230312001Strip · inoperativeROW 16 EMERGENCY LIGHT STRIP INOP MEL 3323 - AUTH# 03-79-C REF LOG PAGE 4910549-3 -C/A-RAR ROW 16 FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12.OPS CHECK GOOD. M PROCEDURES REVERSED. MEL ITEM RESTOREDSDR SIMA20230205001Not Reported · not reportedON CLIMBOUT LANDING GEAR DISAGREE / DECLARED EMERGENCY OVRWT LNDG / EQP SWAP FLT CONT. LANDING GEAR DISAGREE WARNING MESSAGE AFTER GEAR RETRACTION. FOLLOWED QRH UPON EXTENSION ALL GREEN DOWN AND LOCKED. GEAR RETRACTION GOT LND GEAR DISAGREE AGAIN WITH REG NOSESDR SIMA20220903002None · unserviceableSEAT 12A EMERGENCY LIGHT PLACARD INOP-C/A-RAR EMERGENCY BATTERY POWER SUPPLY 3 AND BATTERY PACK 3 IAW ENVOY WORK CARD 33-700-19. OPS CHECK GOOD. END.SDR SIMA20220903001None · unserviceableSEAT 3B EMERGENCY EXIT PLACARD INOP-C/A-RAR EMERGENCY BATTERY POWER SUPPLY 2 AND BATTERY PACK 2 IAW ENVOY WORK CARD 33-700-19. OPS CHECK GOOD. END.SDR SIMA20220731002Light · inoperativeLH FWD BELLY PANEL EMERGENCY LIGHT INOP.-C/A-RAR LH FWD BELLY PANEL EMERGENCY LIGHT ASSEMBLY, IAW AMM 33-50-10.SDR SIMA20220611001Lamp · inoperativeEXTERNAL EMERGENCY LIGHT FORWARD OF LH WING INOP-C/A-RAR EXTERNAL EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10. OPC GOODSDR SIMA20220517002None · noneHIGH SPEED ABORT TO FOR HS VALVE 2 FAIL / NO INJURIES REPORTED. HWS VLV 2 FAIL ON TAKEOFF ROLL SHORTLY AFTER SETTING TAKEOFF THRUST-C/A-PERFORMED TROUBLESHOOTING PER FIM 36-11-00-810-810-A. RAR HIGH STAGE VALVE PER AMM 36-11-02. OPC GOODSDR SIMA20220506001None · unserviceableMEL 2532 - AUTH# 05008M-C. LGPG 4874263. AFT FA FLASHLIGHT HOLDER CLIP BROKEN.-C/A-RAR AFT FA FLASHLIGHT BRACKET IAW AMM EMB145 33-51-01. NO DEFECTS NOTED. MEL ITEM RESTORED.SDR SIMA20220429001None · unserviceableEMERGENCY FLASHLIGHT ABOVE FLIGHT ATTENDANT SEAT WILL NOT CHARGE-C/A-RAR EMERGENCY FLASHLIGHT IAW AMM 33-50-16 OPS CHECK GOOD.SDR SIMA20220211004None · noneTHIS IS A SUPPLEMENTAL SHOWING THE FWD CARGO SMOKE DETECTOR WAS REPLACED P/N 473597-13 S/N 0094. BAGGAGE SMOKE WARNING ON DURING FLIGHT. C/A BLEW BOTTLES.MECH EMERGENCY DECLARED AT 14,000FT/ BAGG EXT BUTTON PRESSED PER QRH. REST OF QRH CW-C/A-RAR BOTH BAGGAGE SDR SIMA20210925003None · noneLG AIR/GND FAIL EICAS CAUTION DURING GEAR EXTENSION. WENT AWAY DURING GO AROUND."TRANSFERRED TO NRWC 668-ORD-05302" DECLARED EMERGENCY-C/A- RAR RH NLG ACTUATOR. REF NRWC 688-ORD-05302 FOR CORRECTIVE ACTIONS TAKEN.OPS CHECK GOOD. REF NWC 688-ORD-05302 FOR CORRESDR SIMA202109098002Flashlight · inoperativeMEL ITEM 25-32 AUTH 090096M-CLOG PAGE 4793078/1FA FWD EMERGECNY FLASHLIGHT INOP-C/A-RAR EMERGENCY FLASHLIGHT IAW AMM 33-50-16 OPS CHECK GOOD MPROCEDUES REVERSED MEL ITEM RESTOREDSDR SIMA202109097001Flashlight · inoperativeFA FWD EMERGENCYFLASH LIGHT INOP-C/A-FLIGHT CREW PLACRD FWD FA EMERGENCYFLASH LIGHT IAW MEL 2532 M PROC C/W MOC # 624980SDR SIMA20210505001Skin · damagedRUDDER 2 SKIN AND ATTACH ANGLE DAMAGE CAUSED BY FOD JUST BELOW THE LOWER HINGE POINT.-C/A-REPAIRED IAW ERS-EM-55MR-884 AND ERS-EM-55-885SDR SIMA20210427001Bushing · migratedR/H AILERON PCA FITTING HAS 3 EA MIGRATING BUSHINGS.(2 OUTBD BUSHINGS ARE LOOSE IN THE FITTING BORE) -C/A-RAR RH AILERON PCA FITTING ASSY IAW EO EM-27MR-112.SDR SIMA20210420005Floor Support · corrodedCPCP SSI: LH OUTBOARD FLOOR SUPPORT IS CORRODED AT NUTPLATE JUST AFT OF FRAME 20.-C/A-RAR'D LH OUTBD. FLOOR SUPPORT JUST AFT OF FR 20 IAW SRM 51-40-02.SDR SIMA20210419003Shim · migratedRUDDER #1 TO VERTICAL STAB LOWER HINGE POINT SCHACKLE HAS MIGRATING AND DAMAGED SHIMS.-C/A-RAR LOWER HINGE ASSY IAW EMB 145 SRM 51-40-02. (MAJOR REPAIR)SDR SIMA20210416009Firewall · crackedAPU FIREWALL HAS A CRACK PROTRUDING FROM THE UPPER R/H MOUNT-C/A-REPAIRED APU FIREWALL ON RH UPPER MOUNT IAW ETN-EM-53-244 R3.SDR SIMA20210416005Skin · crackedFUSELAGE SKIN HAS 4 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 79 BETWEEN STR 6R-7R. -C/A-REPAIRED SKIN AT FRAME 79 BETWEEN STR 6R-7R IAW SRM 53-32-01.SDR SIMA20210416008Skin · crackedFUSELAGE SKIN HAS 13 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 77 BETWEEN STR 3L-7L. E854459, E854460, E854461, AND E854462-C/A-REPAIRED SKIN AT FRAME 77 BETWEEN STR 3L-4L IAW SRM 53-32-01.-REPAIRED SKIN AT FRAME 77 BETWEEN STR 4L-5L IAW SRM 53-32SDR SIMA20210416007Skin · crackedFUSELAGE SKIN HAS 9 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 78 BETWEEN STR 5L-7L. (E854463, E854464) -C/A-REPAIRED SKIN AT FRAME 78 BETWEEN STR 6L-7L IAW SRM 53-32-01. AND REPAIRED SKIN AT FRAME 78 BETWEEN STR 5L-6L IAW SRM 53-32-01.SDR SIMA20210416006Skin · crackedFUSELAGE SKIN HAS 4 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 77 BETWEEN STR 3R-4R. -C/A-REPAIRED SKIN AT FRAME 77 BETWEEN STR 3R-4R IAW SRM 53-32-01.SDR SIMA20210415009Mount · crackedCARGO DOOR TORSION BAR MOUNT FLANGE IS CRACKED ON THE FWD. END AT FR 61RH. -C/A-RAI CARGO DOOR TORSION BAR MOUNT AT FRAME 61 IAW SRM 51-40-02.SDR SIMA20210415008Floor Support · crackedSSI CENTER OMEGA BEAM OUTBD SUPPORT ANGLE IS CRACKED JUST AFT OF FRAME 46 -C/A-REPAIRED CENTER OMEGA BEAM OUTBD SUPPORT ANGLE JUST AFT OF FR46 IAW SRM 53-23-02-RE AND SRM 51-40-02.SDR SIMA20210415007Bracket · crackedCARGO DOOR HOLD OPEN ROD BRACKET IS CRACKED ON THE FUSELAGE. -C/A-RAR'D CARGO DOOR HOLD OPEN ROD BRACKET IAW SRM 51-40-02.SDR SIMA20210415005Channel · crackedR/H HAT BEAM SUPPORT IS CRACKED BETWEEN FRAMES 47 AND 48. -C/A-REPAIRED RH HAT BEAM SUPPORT IAW SRM 53-23-02. AND SRM 51-40-02.SDR SIMA20210415006Support · corrodedCPCP SSI R/H FLOOR/WALL SUPPORT IS CORRODED FROM FRAMES 50-57.-C/A-RAR RH FLOOR/WALL SUPPORT FROM FRAMES 50-57 IAW EMB 145 SRM 51-40-02.SDR SIMA20210411001Wire · brokenTHE SECOND EMERGENCY LIGHT STRIP ( GOING AFT ) HAS BROKEN WIRES AT THE POTTED END, REQUIRES REPLACEMENT.-C/A-COMPLETE:INSTALLED NEW #2 EMERGENCY LIGHT STRIP IAW AMM 33-50-12, OPS CHECK GOODSDR SIMA20210411003Connector · detachedTHE SECOND EMERGENCY LIGHT BELOW FLOOR WIRING (FLOOR BOARD 241BF) NEEDS A NEW CONNECTOR DUE TO THE ONE USED HAD TO BE CUT OFF,-C/A-COMPLETE:REPLACED CONNECTOR FOR EMERGENCY LIGHT UNDER FLOORBOARD 241BF IAW SWPM 20-50-00. REF NRWC E354290 FOR OPC.SDR SIMA20210227002Unknown · odorWHILE IN CRUISE FLIGHT FL30, COMING INTO DFW, WE EXPERIENCED HEAVY MODERATE TURBULENCE. WHILE GOING THROUGH IT, WE STARTED TO SMELL IN THE COCKPIT, AND SOME PASSENGERS SMELL IT TOO IN THE CABIN.-C/A-PERFORMED INSP. FOR SMOKE/ABNORMAL SMELL IN CABIN/COKPIT - UNSDR SIMA20210122001Connector · burnedBURNING SMELL NEAR ROW 8 IN CABIN WHEN PACK AND RECIRC FANS ON. CEILING LIGHT ASSY AT SEAT 6 CB SHOWS BURN MARKS ON CONNECTOR REF. TO AML 4523826 ITEM #1 BURNING SMELL NEAR ROWS 6,7 AND 8 IN CABIN PER WORK SCOPE INSPECTION.PERFORM FIM TASK 21-20-00-810-801-A (SDR SIMA20201231001Cradle · brokenAFT FLASHLIGHT MOUNT CLIP BROKEN. C/A: R & R AFT FLASHLIGHT, IAW ENVOY ETN-EM-33-059. OPERATIONS CHECK GOOD.SDR SIMA20201101002Cradle · brokenREAR EMERGENCY FLASHLIGHT HOLDER BROKEN IN CABIN. C/A: R & R EMERGENCY FLASHLIGHT ASSEMBLY, IAW AMM EMB-145 AMM 33-50-16. OPERATIONS CHECK GOOD.SDR SIMA20201011004Warning Message · false activationLAV SMOKE INDICATION WARNING IN FLIGHT. PASSENGER WAS IN LAV, FA REPORTS DID NOT SEE OR SMELL SMOKE. PASSENGER OPENED LAV DOOR. DECLARED EMERGENCY. C/A: PERFORMED OPERATIONS CHECK OF LAV SMOKE DETECTION SYSTEM, IAW AMM 26-14-00. OPERATIONS CHECK GOOD AT TSDR SIMA20200908002Unknown · odorSMOKE IN COCKPIT, BURNING SMELL IN THE AIRPLANE ON CLIMBOUT. NO SMOKE AND NO EICAS MESSAGES. TROULBESHOOTING ITEM NR 1, BURNING SMELL IN AIRPLANE. ETN -EM-72-034 DUE. C/A C/W ETN-EM-72-034.SDR SIMA202009086006Cradle · brokenFLASHLIGHT BRACKET BEHIND CAP & SHAIR BROKEN. C/A-RAR CAP FLASHLIGHT PER EMB AMM 33-50-16.SDR SIMA202006265001Connector · brokenBROKEN ELECTRICAL CONNECTOR ON FLOOR LIGHTING STRIP AT SEAT 7A.-C/A-INSTALLED NEW CONNECTOR ON LIGHTING STRIP AT SEAT 7A PER SPWM 20-50-01. OPS CK GOODSDR SIMA202006187002Unknown · odorFA REPORTS CHEMICAL SMELL IN CABIN AND SAYS CABIN BECAME VERY WARM. CABIN TEMP INDICATIONS SHOWED 18C. PACK 1 AND 2 OPERATIONAL TESTS GOOD WITH APU AND BOTH ENGINE PNEUMATIC SOURCES IAW AMM 21-51-00. PACK 1 AND 2 GVI AND LEAK CHECKED GOOD IAW AMM 21-51-14. NOSDR SIMA2020051403003Light · inoperativeSERVICE DOOR EMERGENCY LIGHT IS INOP-C/A-REMOVED AND REINSTALLED SERVICE DOOR EXTERNAL EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10. OPS-CK GOOD.SDR SIMA202003198003Flashlight · brokenSUPPLEMENTAL AFT CABIN FLASHLIGHT BROKEN-C/A-FLIGHT CREW PLACARD AFT CABIN FLASHLIGHT AUTH 030546-C REF - 25-53 MOC 864015. REMOVED AND REPLACED AFT CABIN FLASHLIGHT IAW EMB 145 AMM 33-50-16 OPS CHECK GOOD . MEL ITEM RESTOREDSDR SIMA202003065004Power Supply · disconnectedDURING PS-2 CHECK , WAS FOUND FWD CABIN EMERGENCY LIGHTS INOP.-C/A-RECOONNECTED #1 EMERGENCY KLIGHT POWER SUPPLY IAW EMB-145 AMM 33-50-04 . OPS CHECK GOOD.SDR SIMA2019010227003Wire · brokenEMERGENCY LIGHTING SYSTEM (FLOOR PROXIMITY STRIP) AT SEAT 3A WIRE BROKEN INOP-C/A-EMER FLOOR STRIP LIGHTING AT SEAT 3A DEFERRED. REPAIRED BROKEN WIRE AT FLOOR STRIP 3A IAW SWPM 20-21-00. OPS CHECK GOOD. MEL RESTORED.SDR SIMA201911276002Apu · malfunctionedAPU FAIL & SHUTDOWN DURING STEADY STATE OPERATION AT FL360.-C/A-CHECKED OK FOR DEFERRAL PER MEL 49-1. M PROCEDURES C/W. AUTH # 110898DM-C. EXPIRES 12-6-19. PLACARD INSTALLED. PERF OPERATIONL TEST OF APU WITH BOTH ELECTRICAL AND PNEUMATIC LOADS IAW EMB 145 SDR SIMA201910109003Lamp · inoperativeAFT CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED AFT CEILING EMERGENCY LAMP IAW AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPS CHECK GOOD.SDR SIMA201906243003Pressure Switch · corrodedNO TAKEOFF CONFIG WARNING ON THRUST SET WITH PERIMETER APPEARING OK. IN PARALLEL "TAKE OFF OK" IS GIVEN WITH P. BRAKE SET. FOUND PARKING BRAKE PRESSURE SWITCH AND PARKING BRAKE PRESSURE SWITCH CONNECTOR SEVERELY CORRODED. REPLACED BOTH. OPS/CK LK/CK GOOD. TAKSDR SIMA201906184006Bolt · damagedMAIN CABIN DOOR JAMMED IN THE CLOSED POSITION & WOULD NOT OPEN-C/A-DURING INSPECTION FOUND BOLT AND NUT SECURING DOOR HANDLE TO BE DAMAGED. REMOVED AND REPLACED BOLT AND NUT IAW EMB AMM 52-18-05