N673FE
Service difficulty reports · 360
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673FE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673FE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201503070709Floor Panel · delaminatedPANEL RACK, PANEL 147 AF UPPER SURFACE HAS THE SKIN DELAMINATING. FLOOR PANEL 147 AF FABRICATED ON T15 1125577 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503070708Floor Panel · delaminatedFLOOR PANEL 252UH DELAMINATED AROUND DENTS. FLOOR PANEL 252 UH FABRICATED ON T15 1125224 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503070707Floor Panel · delaminatedMDC FLOOR PANEL 232 BH DAMAGED & DISBONDED SKIN, PANEL RACK. FLOOR PANEL 232 BH FABRICATED ON T15 1125733 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503050694Floor Panel · delaminatedFLOOR PANEL 232GG, PUNCTURED & DELAMINATED FLOOR PANEL 232GG. FABRICATED ON T15 1125753 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503050693Floor Panel · delaminatedMCD FLOOR PANEL 232LG DAMAGED & DISBONDED, PANEL RACK, FLOOR PANEL 232LG. FABRICATED ON T15 1125754 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503050692Floor Panel · damagedMCD FLOOR PANEL 231QG DAMAGED, PANEL RACK. FLOOR PANEL 231QG FABRICATED ON T15 1125756 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503050691Floor Panel · damagedMCD FLOOR PANEL 231RG DAMAGED, PANEL RACK. FLOOR PANEL 231RG FABRICATED ON T15 1125757 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503050689Floor Panel · damagedFLOOR PANEL 252RH, DAMAGED. FLOOR PANEL 252RH FABRICATED ON T15 1125761 IAW DWG SRZ 25- 005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503050687Floor Panel · damagedFLOOR PANEL 241 ZJ, DAMAGED. FLOOR PANEL 241 ZJ FABRICATED ON T15/1125762 IAW DWG SRZ-25- 005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503020629Seat Track · corrodedMDCC FLOOR SEAT TRACK HAS SPOTS OF CORROSIONS LOCATED FRAME 78 TO 12 INCHES FWD OF FRAME 75, Y450.SDR FDEA201412194176Skin · delaminatedLEFT WING NR 4 SPOILER HAS A DELAM ON OTBD EDGE UPPER SURFACE. EVALUATED SPOILER PANEL & FOUND PLYS SEPARATING ON OTBD END PANEL BEYOND ALLOWABLE. DAMAGE WILL REQUIRE R & R IAW SRM 57-72-11. R & R LT WING NR 4 SPOILER IAW AMM 27-61-51-04. STILL REQUIRES OPSDR FDEA201412164182Spoiler · faultyFIRST OFFICER`S PREFLIGHT, LT NR 5 SPOILER NOT FAIRED. NEED NR 5 LT SPOILER PANEL & ACTUATOR AMM, SMP. R & R LT WING NR 5 SPOILER PANEL IAW MM 27-61-53-04. R & R LT WING NR 5 SPOILER PANEL ACTUATOR IAW MM 27-64-14-04. BOTH OPERATIONS & LEAK CHECKED GOOD. SDR FDEA201407101692Floorboard · damagedFLOORBOARD PNL 122NF IS DAMAGED AT INSERT HOLE & INSERT MISSING REPAIRED FLOORBOARD PNL 122NF IAW SRM 53-10-20 REPAIR 9.SDR FDEA201407091675Mount · damagedNUMBER 1 ENG PYLON FWD MOUNT HAS LIGHT PITTING & BOLT THREAD MARKS IN ALL FOUR HARDWARE BORES & BOTH AFT TWO EACH UPPER BORE SPOT FACE SURFACE. REPAIRED NR 1 ENG PYLON MOUNT IAW SRM 54-51-81.SDR FDEA201406011242Fitting · corrodedRIGHT MLG RIB 5 FWD LUG HAS CORROSION IN BORE, FWD & AFT FACES. COMPLIED WITH EA 6-5710-T0309069 P1.SDR FDEA201405301241Fitting · corrodedLEFT MLG RIB 5 FWD LUG HAS CORROSION IN BORE, FWD & AFT FACES. REPLACED FITTING IAW E.A. 6-5710-T0308917 P-2.SDR FDEA201401040020Transmitter · leakingIDENTIFIED A COVER HAS A BROKEN FLANGE IAW CMM 29-09-39 ITEM 20, WHICH CAUSED MASSIVE HYD LEAK. HYD PRESSURE TRANSMITTER HAS APPROXIMATELY 3000PSI COMING TO & THROUGH IT WHICH COULD CAUSE DAMAGE TO ACFT OR PERSONNEL. R & R BLUE SYS HYD PRESSURE TRANSMITTER.SDR FDEA201308161912Priority Valve · failedDURING TAKEOFF ROLL, RECEIVED AN ECAM BLUE HYD LOW PRESSURE WARNING. ACCOMPANIED BY AIR LIGHT AND LOW PRESSURE LIGHT ON OVERHEAD PANEL. ECAM SHOWED LOSS OF ALL HYDS ON BLUE HYD SYSTEM. FOUND BOTTOM OF BLUE SYS PRIORITY VALVE BLOWN APART. R & R BLUE HYD SYSDR FDEA201207222641Floorboard · crackedMAIN DECK CARGO FLOORBOARD 251QH HAS AN 8 INCH CRACK AROUND CLEVIS CUT OUT. FABRICATED FLOORBOARD IAW DWG SRZ 25-005.SDR FDEA201207222640Floor Panel · crackedMAIN DECK CARGO AT FR 60 TO 62 INBETWEEN CARGO TRACKS 2L AND 3L FLOOR PANEL 250UH HAS A 7 INCH CRACK IN HONEYCOMB SKIN. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005 REV. JSDR FDEA201207222639Skin · dentedRT WING AILERON UPPER SURFACE T/E HAS 35 DENT FROM INBD EDGE TO OTBD EDGE LARGEST IS .5" L X .5" W X .011"D DENTS FOUND OUT OF LIMITS DUE TO DENTS BETWEEN REAR SPAR AND T/E AILERON IAW SRM 57-61-11, PG 108, PARA 6. R & R RT ASA IAW AMM 27-11-28-04. OPS CHECKESDR FDEA201207172597Seat Track · corrodedMAIN DECK CARGO AT FR 69 AND FR 70 SEAT TRACK 1 HAS CORROSION ON TOP OF SEAT TRACK SCALLOPS, REMOVED TWO AREAS OF LEVEL 1 CORROSION IAW SRM 53-10-16, FIG 201.SDR FDEA201207172599Floorboard · crackedFLOORBOARD 252YG HAS 1-4" AND 1-6" CRACK AT CLEVIS ADAPTER CUT OUTS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207172598Floorboard · damagedFLOORBOARD 151UF DAMAGED. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REVJ.SDR FDEA201207162589Floorboard · delaminatedFLOORBOARD 132LG HAS 32 SQUARE INCHES OF DELAMINATION & FIVE, ONE INCH PUNCTURES. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 055, REV J.SDR FDEA201207162581Cargo Track · corrodedMAIN DECK CARGO AT FR73 TO FR77 SEAT TRACK 1 HAS CORROSION ON THE INSIDE OF SEAT TRACK AND ON TOP OF SCALLOPS; 3 EA AREAS. AFTER REMOVAL OF LEVEL 1 CORROSION SEAT-TRACK 1 AT FR73 TO FR77 WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16. CUT AND REMOVED SEAT SDR FDEA201207142576Attach Fitting · crackedSEAT TRACK SUPPORT FITTING 10 INCHES BELOW SEAT TRACK 4R AT FR 48 HAS A CRACK THROUGH THE INBD LUG. R & R SEAT TRACK SUPPORT FITTING IAW FSRM 51-72-10, PG 1-3.SDR FDEA201207132574Floor Panel · crackedFLOOR PANEL 132RF HAS 3 AREAS OF EDGE DAMAGED, A PUNCTURE, A 9, 5, AND 3 INCH CRACK. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207132573Floor Panel · crackedFLOOR PANEL 132RF HAS 3 AREA OF EDGE DAMAGE, A PUNCTURE, AND A 9, 5, AND 3 INCH CRACKS. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207132569Floor Panel · crackedFLOOR PANEL 251BH HAS TWO, SIX INCH CRACKS AROUND CLEVIS ADAPTORS, FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207132566Floor Panel · crackedFLOOR PANEL 132RF HAS 3 AREAS OF EDGE DAMAGE, A PUNCTURE, AND A 9 INCH CRACK, A 5 INCH CRACK AND A 3 INCH CRACK. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207132572Floor Panel · damagedFLOOR PANEL 151PF BROKEN AT THE EDGE AND LOWER SURFACE. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207132571Floor Panel · damagedFLOOR PANEL 152MF BROKEN AT EDGES IN 3 PLACES. FABRICATED FLOOR PANEL IAW DWG SRZ25-005 REV J.SDR FDEA201207132570Floor Panel · damagedFLOOR PANEL 242LK BROKEN. FABRICATED FLOOR PANEL IAW DWG SRZ25-005 REV. JSDR FDEA201207132568Floor Panel · damagedFLOOR PANEL 152UF HAS 60 INCHES OF EDGE DAMAGE. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207132567Floor Panel · damagedFLOOR PANEL 152VF BROKEN AT EDGES UPPER AND LOWER SURFACES. FABRICATED FLOOR PANEL IAW DWG SRZ25-005 REV J.SDR FDEA201207132565Floor Panel · damagedFLOOR PANEL 152XF BROKEN IN TWO PLACES, AT EDGE. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207132563Seat Track · corrodedFR 73 & FR 74 SEAT TRACK 4R HAS CORROSION ON SEAT TRACK SCALLOP. REMOVED CORROSION FROM SEAT TRACK 4R FR 73 -74 ON UPPER SURFACE AND MATERIAL LOSS WAS OUT OF LIMIT IAW FSRM 53-10-10, PG 105, VIEW A. REMOVED SEAT TRACK AND REPLACED IAW SRM 51-40-21, PARA 6 ANSDR FDEA201207122559Floor Panel · damagedFLOOR PANEL 151VF HAS COMPOSITE DAMAGE TO THE LT EDGE, BOTTOM PLY IS CRUSHED, TOP PLY IS RIPPED AND EDGE FILLER IS MISSING. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207122558Floor Panel · crackedFLOOR PANEL 252UH HAS TWO, EIGHT INCH CRACKS AROUND CLEVIS ADAPTORS. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207122553Adapter · damagedFLOOR CLEVIS ADAPTER AT FR59 BETWEEN SEAT TRACKS 3L AND 4L HAS 3 AREAS OF SCALLOPS BROKEN. R & R FLOOR CLEVIS ADAPTER AT FR59 BETWEEN SEAT TRACKS 3L AND 4L IAW SRM 51-72-10.SDR FDEA201207112546Floor Panel · crackedFLOOR PANEL 242QJ HAS THREE, TEN INCH CRACKS. FABRICATED AND REPLACED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207112545Floor Panel · crackedFLOOR PANEL 242UJ HAS THREE, TEN INCH CRACKS. FABRICATED AND REPLACED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201207102533Floor Panel · delaminatedFLOOR PANEL 131RF HAS 20 SQUARE INCHES OF DELAMINATION AND TORN SKIN. FABRICATED FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201111024723Selector Valve · failedATTEMPTED LANDING EXTENSION HANDLE MOVED TO DOWN POSITION WITH NO INDICATION. CYCLED SWITCHED SYS. NO CHANGE. MANUAL EXTENSION ACCOMPLISHED. R & R LANDING GEAR SELECTOR VALVE (3GA) IAW-MM 32-31-12-04. OPS AND LEAK CHECKED NORMAL.SDR FDEA201110074352Ecu · failedNR 1 ENGINE POSSIBLE COMPRESSOR STALL WHILE DESCENDING. HEARD A POP ON LT SIDE AND NOTICED NR1 N1 RPM AT 20 PERCENT, EGT AT 700 DEG, AT N2 58 PERCENT ENGINE WOULD NOT RESPOND TO THROTTLE INPUTS. ENGINE APPEARED TO RECOVER TO NORMAL AFTER LANDED & TAXIED CLEASDR FDEA201108173323Check Valve · malfunctionedON FINAL APPROACH, NR 1 ENG STARTED TO VIBRATE AFTER A BANG. EGT WENT TO 700 DEG. ENGINE WAS AT FLIGHT IDLE. ENGINE APPEARED TO COME BACK AND OPERATE FINE. ON LANDING ROLLOUT, THE EGT CLIMBED TO 710 DEG. AND INCREASING. SHUTDOWN ENGINE. N1 & N2 LOOKED NORMASDR FDEA201011254487Smoke Detector · dirtyAIR TURN BACK FOR "AVIONICS SMOKE" ECAM. NO EMERGENCY DECLARED. FOUND WATER IN AVIONICS SMOKE DETECTOR. R & R AVIONICS SMOKE DETECTOR AS REQUIRED. OPS CHECK GOOD REF MM 26-15-12-04-0. PREMATURE REMOVAL/INSTALLATION. NOTE: PREV WRITE UP AT GATE - WATER CLSDR FDEA201009023239Seat Track · corrodedRIGHT NR 1 SEAT TRACK CORROSION AT FR58 POSITION. REMOVED THE CORROSION TRACK. POSITION AND TRANSFER DRILL THE FASTENER HOLES. REINSTALL WITH FASTENER. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA201009023242Seat Track · crackedRT NR 4 SEAT TRACK CRACKED AT FR 39 2". REPLACED THE SEAT TRACK BY FASTENER INSTALLED IAW AB6F, SRM 51-40-21. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.
Back to N673FE