N673NK
Service difficulty reports · 34
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2025021038733Unknown · odorBETWEEN 8000-9000 FEET WE NOTICED A MILD CHEMICAL ODOR. I PERFORMED THE ELIMINATION OF ODOR/FUMES CHECLIST PER THE QRH. AFTER CALLING THE FA'S, I COULD NOT DETERMINE THE SOURCE AS THEY SMELLED IT IN THE CABIN ASWELL.-IAW TSM 05-50-00-810-831-A THE HIGHEST TOTASDR GTIA2024123138640A/C Pack · odorAIR QUALITY EVENT OF DESCENT ( PACKS )-REF LP 3612799-1 - INSPECTED PACKS 1 & 2. DID NOT FIND CONTAMINATION. PERFORMED LEVEL A DECONTAMINATION OF ENVIRONMENTAL CONTROL SYSTEM IAW AMM 21-00-00-615-802-A. DID NOT FIND AN AQE TO PRESENT DURING THIS TIME. R/R AIRSDR GTIA2024032238008Epsu · faultyDURING SVC ITEM #13 EMERGENCY GENERATION FOUND 15WL EPSU BATTERY FAULTING-R/R 15WL EPSU BATTERY IAW AMM 33-51-38. OPS CHECK GOOD. FAULT CLEARED. A/C OK FOR CONTINUED SERVICESDR GTIA2023020636942Not Reported · not reportedL4 PASSENGER DOOR ASSIST BOTTLE LOW.-CHARGED L4 PAX DOOR ASSIST CYLINDER BOTTLE PER AMM 52-10-00-614-001-A LEAK TEST NORMAL, OK FOR SVC.SDR GTIA2023012636907Fan · faultedVENT BLOWER FAN FAULT-FOUND CB AD10 AVNCS VENT/BLOWER/FAN POPPED. REF TSM 21-00-00-810-804-A. REMOVED AND REPLACED FIN 20HQ FAN-AVIONICS IAW AMM 21-26-51-400-001A. OPS CHECK GOOD. NO ODOR NOTED.SDR GTIA2022120536822Battery Pack · no test"EPSU BATTERY 13WL FAILED ON TEST. EPSU BATTERY (13WL) REPLACED I.A.W AMM 33-51-38-000/400-002-A REV.74 TEST OK."SDR GTIA2022120536821Battery Pack · no test"EPSU BATTERY 14WL FAILED DURING TEST. EPSU BATTERY (14WL) REPLACED I.A.W AMM 33-51-38-00/400-002-A REV. 74. TEST OK."SDR GTIA2022120536820None · noneDOUBLER BTW FR 81-83 STGR 2 RH RAF 3082720-02 CREATED FOR FURTHER EVALUATION-VERIFIED NR # 5001195484-0010 AND TC # 1003864642-0010 REPAIR WAS PERFORMED AS PER SPIRIT EO 5351- 2267 REVISION 00.SDR GTIA2022111036775Bottle · low pressureR2, L2, & L4 DOOR ASSIST BOTTLES REQ SVC-SVC R3, L2, & L4 DOOR ASSIST BOTTLES PER AMM 52-10-00SDR GTIA2022070436510None · noneDURING WEEKLY FOUND L4 DOOR ASSIST BOTTLE BELOW LIMITS.-SERVICED L4 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00.SDR GTIA2022050236406None · noneL4 DOOR ASSIST BOTTLE REQ SVC-SVC L4 DOOR ASSIST BOTTLE TO PROPER LVL AS PER AMM 52-10-00SDR GTIA2022041136373None · noneL4 DOOR ASSIST BOTTLE REQUIRES NITROGEN SERVICING-SERVICED THE L4 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM:52-22-00SDR GTIA2022033136355Unknown · odorDECENT THRU 10,000 FA SMELLED ODOR IN FWD CABIN COCKPIT ALSO HAS ODOR. TURNED OFF #1 PACK, LANDED ODOR DID NOT DISSIPATE-05-40-00-810-831, RAN ENG 1 AND ENG 2 ISOLATED PACK'S 1&2 WITH NO ODOR NOTED. A/C OK FOR CONTINUED SERVICE.SDR GTIA2022011736227None · noneL4 DOR ASSIST BOTTLE REQUIRES SERVICING -SERVICED L4 DOOR ASSISIT BOTTLES IAW AMM 52-10-00. LEAK CHECK GOODSDR GTIA2021101436047None · noneLH DOOR ASSIST BOTTLE LOW-SVCD L4 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021090635976Megaphone · inoperativeDURING CHECK MEGAPHONE INOP-R&R MEGAPHONE IAW AMM 25-65-51. OPS CK GOODSDR GTIA2021083035957Bottle · low pressureR3 DOOR ASSIST BOTTLE LOW-SVCD R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021083035956Unknown · odorDURING DESCENT FOWL ODOR WAS SENSED BY BOTH PILOTS PROCEDURE WAS THEN FOLLOWED TO IDENTIFY SOUCE BUT COULD NOT IDENTIFY IT-CAPT. STATED HE SUSPECTED HEAVY RAINFALL AS SOURCE OF ODOR. PERFORMED OPS CHECK IAW TSM 05-50-00. NO ODOR NOTED AT THIS TIME. NO FURTHER SDR GTIA2021070135840Bottle · low pressureL4 DOOR ASSIST BOTTLE REQUIRED SERVICING-SERVICED L4 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021032235651Bottle · low pressureL4 DOOR ASSIST BOTLLE REQUIRES SERVICE-SERVICED L4 DOOR ASSITS BOTLLE IAW AMM 52-10-00SDR GTIA2021032235650Bottle · low pressureR1 DOOR ASSIST BOTTLE REQUIRES SERVICE-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021021835601Bottle · low pressureL4 DOOR ASSIST BOTTLE REQ SERVICING. SERVICED L4 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2020102635414Megaphone · inoperativeMEGA PHONE INOPERABLE AFT GALLEY. R & R AFT MEGA PHONE OPERATIONS CHECK OK, IAW CMM 25-60-01.SDR GTIA2020031635090Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW-SERVICED L1 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00. LEAK CHECK GOOD AT THIS TIMESDR GTIA2020031635089Bottle · low pressureR1 DOOR ASSIST BOTTLE LOW-SERVICED R1 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00. LEAK CHECK GOOD AT THIS TIMESDR GTIA2020012834974Skin · damagedPENETRATION DAMAGE FOUND ON RT ELEVATOR LOWER AND UPPER SKIN. DAMAGE LENGTH UPPER 20MM, LOWER 20MM X DAMAGE WIDTH UPPER 5MM, LOWER 15MM X DAMAGE DEPTH THROUGH, CAT A REPAIR, RAF01 2539928-1 OPENED. REVIEWED LTPR NRI 5000966665-0030 AND HAS BEEN ACCOMPLISHED PSDR GTIA2020011334928Bottle · low pressureL4 DOOR ASSIST BOTTLE REQUIRES NITROGEN SERVICE -SVCD L4 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2020011334927Bottle · low pressureRI DOOR ASSIST BOTTLE REQUIRES NITROGEN SERVICE-SVCD RI DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2019030603207Unknown · odorFA IN BACK SMELLED ANITFREEZE AND DIRTY SOCK SMELL ON "FINAL DESCENT". ( PACKS WITH MOD. 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/ MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )--SDR GTIA2018111292956A/C Pack · odorDIRTY SOCKS SMELL ON CLIMBOUT ISOLATED THE SMELL COMING FROM PACKS # 1-APPLIED TSM 05-50-00-810-831A. VISUAL INSP OF ENG, APU FUSELAGE AREAS. NO CONTAMINATION FOUND. SNIFFER TEST WITH NO 1 AND 2 ENGS AND PACKS ON SHOW NO FUME CONTAMINATION. A/C FOUND OK FOR SESDR GTIA2018101502887Bottle · low pressureL2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR ASSIST BOTTLE AS REQUIRED PER AMM 52-10-00.SDR GTIA2018080982791Unknown · odorFUME EVENT, PERFORMED TSM 05-50-00-210-831-A, NO ODOR NOTED WITH A/C PACK SYS OPERATING NORMAL. A/C PACK OK FOR SERVICE.SDR GTIA2018040502561Flashlight · inoperativeFIRST OFFICER`S FLASHLIGHT INOPERATIVE. R & R THE FLASHLIGHT IAW DRAWING NK-321.SDR GTIA2017041701881Oxygen Mask · brokenFIRST OFFICER`S OXYGEN MASK MISSING FASTENER OVER NOSE PIECE. R & R THE OXYGEN MASK IAW AMM 35-12-41, OPS CHECKED GOOD. OK FOR SERVICE.
Back to N673NK