N676UA
Service difficulty reports · 277
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N676UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N676UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011013100506Light · damagedSEAT 30H, SEAT MOUNTED EMERGENCY LIGHT STRIP RIPPED OFF AND WIRE EXPOSED. REPLACED EMERGENCY LIGHT STRIP ASSY.SDR UALA2011012800475Heater · faultedLAV TANK PRECHARGE IN TUBES HEAT BLANKETS B212 AND B213 WIRES ARC TUBES. REMOVED LAV TANKS. SENSORS ARE CORRODED. REPLACED B212 AND B213 WASTE TANK SVCE FITTING HEATERS REF WD AND SSM.SDR UALA2011012600424Roller · wornDURING FLT CONTROL CHECK AILERON STIFF AT MID ROLL. SOMETIMES LT SOMETIMES RT SIDE. FOUND AILERON CENTERING ROLLER WORN & FLATSPOTTED. REPLACED ROLLER IAW IPC. OPS CHECKED GOOD. CONTROL WHEEL SMOOTH FULL TRAVEL.SDR UALA2011012400384Fseu · faultyLEADING EDGE SLAT ASYM EICAS MESSAGE. REPLACED NR 4 INBD L/E SLAT SENSOR IAW 27-88-01. GROUND CHECKED GOOD. FSEU BITE SHOWS MESSAGE NR 27-51333. SEC 3 CB CHECKS NORMAL. REPLACED FSEU, OPS NORMAL.SDR UALA2011010700106Light · unsecureSEATS 4H AND 6H EMERGENCY LIGHTS ARE LOOSE AND HANGING OUT OF SEAT. REINSTALLED EMERGENCY LIGHTS INTO SEATS, OP OKAY.SDR UALA2010122704707Isolation Valve · faultyEICAS & STATUS MSG R REVERSER ISOLATION VALVE. REV LOCKED OUT. TR RELAY MODULE HAD LIGHT ON FOR HIV PRESSURE (HYD ISOLATION VALVE PRESS). REPLACED REVERSER ISOLATION VALVE ON NR 2 ENGINE, FAILED OPS CK, FAULT STILL SHOWING. CORRECTION TO LAST UPDATE, STOW SDR UALA2010121304550Computer · faultyFLIGHT REST SMK VAL STATUS MESSAGE. FOUND LT EICAS COMPUTER WITH INTERNAL FAULTS, REPLACED LT EICAS COMPUTER PER MM. LOADED SOFTWARE AND PERFORMED EICAS BITE WITH NO FAULTS.SDR UALA2010111104188Sensor · faultyL/E SLAT ASSY DISAGREE, RTFL. FOUND NR 4 LE SLAT SENSOR S285 FAULTED DURING PROX BOX BITE. PRIOR TO SENSOR REPLACEMENT FOUND WIRE LENGTH OF W430-04TB-20 AND W430-04TR-20 TOO SHORT TO SPLICE IN NEW SENSOR. LENGTHENED WIRES BY REPOSITIONING 25577 SHIELD TERMINSDR UALA2010102904015Wire · brokenSMALL PART CAME OFF ABOVE SEAT 6H. FOUND SEAT 6H AFT EMERGENCY LIGHT ON SIDE OF SEAT WIRES BROKEN. TAPED WIRES, TAPED LIGHT STRIP TO SEAT. ALL OTHER EMERGENCY LIGHTS CHECK OK.SDR UALA2010102803980Light · dislodgedSEAT 17HJ EMERGENCY LIGHT ATTACHED TO SEAT TORN OFF. TAPPED OVER AREA WHERE EMERGENCY LIGHT ATTACHES. REPLACED EMERGENCY LIGHT SEAT 17HJ.SDR UALA2010102203904Starter · making metalNR 1 ENG FOUND METAL FLAKES ON STARTER CHIP DETECTOR. STARTER OUT OF TOLERANCE. REPLACED STARTER. OPS NORMAL.SDR UALA2010101403816Light · unsecureEMERGENCY EXIT LIGHT DANGLING FROM THE CEILING AT 6H. SEAT 6H IS MISSING 1 OF 2 OF THE SEAT MOUNTED ESCAPE PATH LIGHTS, REMAINING LIGHTS OPERATED NORMALLY IAW MEL REQUIREMENTS. REPLACED LIGHT. OPS CK GOOD.SDR UALA2010092803583Warning Light · false activationON PREFLIGHT "RAM AIR TURBINE PWR" CB TRIP. PERFORMED EXTENSION AND RETRACTION IAW MM. CHECKS OK.SDR UALA2010090703278Skin · damagedFWD FUSELAGE LWR AREA BETWEEN E&E DOOR AND LT NLG DOOR HAS 2 EACH AREAS OF SKIN DAMAGE AT FASTENERS FROM STATIC BURN. IAW EG REMOVED DAMAGE BY OPENING 1 HOLE TO 1-4 INCH AND SPOTFACING SKIN AT FASTENER REMOVED .050 AND .045 MATERIAL FROM SKIN.SDR UALA10080902893APump · faultyFLIGHT CONTROL ISSUE, FLIGHT DIVERTED. ON TAKE OFF, EXCESSIVE RUDDER TRIM ON CLIMB. RT INBD AIL ON EICAS SHOWS IN UP POSITION. CONFIRMED BY F/O, RT INBD AIL NOT MOVING, STUCK IN UP POSITION. RUDDER SYS FOUND NORMAL AT CTR WITH 0 TRIM. WITH CTR SYS ONLY PRESSUSDR UALA2010080902893Actuator · faultyFLIGHT CONTROL ISSUE, FLIGHT DIVERTED. ON TAKEOFF, EXCESSIVE RUDDER TRIM ON CLIMB. RT INBOARD AIL ON EICAS SHOWS IN UP POSITION. CONFIRMED BY FIRST OFFICER, RT INBOARD AIL NOT MOVING, STUCK IN UP POSITION. RUDDER SYS FOUND NORMAL AT CENTER WITH 0 TRIM. WITSDR UALA2010072602670Skin · damagedLIGHTNING STRIKE STA 564 BETWEEN STR 38&39. REMOVED DAMAGE, NDT INSPECTED AND TREATED BARE SKIN. WAITING FOR CLARIFICATION REGARDING DETAIL VIII. REPAIRED REF UA-EVA-73983.SDR UALA2010071902569Nozzle · out of positionAFT CARGO PIT SMOKE DETECTION NOZZLE DOES NOT PROTRUDE PAST CEILING PANEL DRIVE BAY E STA 1275, SECOND TO LAST SMOKE NOZZLE, INTERIM REPAIR MADE TO CEILING PANEL WITH CARGO PIT TAPE, SMOKE DETECTION NOZZLE NOW PROTRUDES 1-2 INCH. RESECURED CEILING AS NEEDED ISDR UALA2010070602385Light · inoperativeROW 37 RT, ROW 41 RT, ROW 41 LT CEILING EMERGENCY LIGHTS INOP. RELAMPED, OPS OKAY.SDR UALA2010070602384Light · missingROW 26H SEAT EEL STRIP MISSING. REPLACED STRIP.SDR UALA2010061102043Charger · faultedMAIN BATTERY CHARGER STATUS MESSAGE. REPLACED MAIN BATTERY AND CHARGER.SDR UALA2010060101892Battery · faultyMAIN BATTERY CHARGER STATUS MESSAGE. REPLACED ACFT MAIN BATTERY. ERY. OPS GOOD.SDR UALA2010052701831Light · missingSEAT 15HJ EMERGENCY LIGHT IS MISSING.SDR UALA2010052601805Light · missingSEAT 15HJ EMERGENCY LIGHT IS MISSING. REPLACED, OPS CKD OKAY.SDR UALA2010051301624Spacer · missingDUE TO NR 1 TIRE TEMP RISING AFTER TAKEOFF, CREW HAD TO EXTEND AND RETRACT GEARS 2 TIMES IN ORDER TO COOL OFF THE WHEEL. THE TIRE WAS REPLACED, REMOVE THE TIRE IAW MM. INSPECT GEAR AXLE FOR OVERHEAT CONDITIONS. FOUND MISSING SPACER, IN ADDITION FOUND DAMASDR UALA2010042701404Actuator · faultyNR 1 ENGINE DRAIN NR 3 CONFIG 2, FUEL LEAKING 30 DROPS PER MIN STATIC ONLY. SPLIT THE DRAIN LINES AND FOUND THE VSV ACTUATOR AT FAULT. REPLACED NR1 ENG SVA IAW MM. OPS AND LEAK CHECK GOOD.SDR UALA2010041501272Light · inoperative39A SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHT INOP. REPLACED LIGHT, OPS CHECK OKAY.SDR UALA2010041401255Power Supply · intermittentEMERGENCY LIGHTS ON LAST 5 ROWS R SIDE ND EXIT SIGN 2R ON INTERMITTENTLY. REPLACED EMERGENCY LIGHT POWER SUPPLY M1556, AT STA 1384, RT SIDE. OPS CHK OK.SDR UALA2010032901044Wire · chafedOFF THE GATE RT GEN TRIPPED OFF, RESET RT GEN AND AGAIN TRIPPED OFF. FOUND YELLOW WIRE FOR IDG PMG CHAFED. NO DAMAGED WIRES. REPAIRED INSULATION. RAN ENG TWICE, GENERATOR OPS NORMAL.SDR UALA2010032501004Accelerometer · faultyNR 2 ENG VIBRATION. ACP'D HIGH POWER RUN, ENG PARAMETERS: AT 1.40 EPR, VIB = L ENG 1.4, R ENG 2.0, AT 1.26 EPR L ENG 1.5, R ENG 3.1, AT 1.15 EPR L ENG 0.6, R ENG 1.4. ACP'D T ROUBLESHOOTING IAW FIM71-05-00, FIG 104, BLOCKS 1-8. NO DEFECTS FOUND. ACCOMPLISHEDSDR UALA2010031200837Controller · faultyAPU SHUTDOWN AT GATE. REPLACED ECU PER MM. REPLACED RELAY K197. OPS CHECK OKAY.SDR UALA2010022400680Lamp · brokenFWD EMERGENCY LIGHT ON SEAT WAS BROKEN OFF. REPLACED SEAT 6H EMERGENCY LIGHT LAMP ASSY, OP CHECKS GOOD.SDR UALA2010022200661Apu · inoperative2 APU START ATTEMPTS NO START WITH APU FAULT LIGHT. BITE CHECKED THE ECU. HAVE AUTOSHUTDOWN. NO COMPONENT FAULT. WILL NOT START. REPLACED APU. REPLACED APU BATTERY CHARGER PER SERVICE TIP DUE TO APU NO START AND PNEUMATIC FLUCTUATIONS. OP CHECKS GOOD FOSDR UALA2010022200662Pseu · malfunctionedEICAS MSG LE SLAT ASYM DISPLAYED, LEADING EDGE LIGHT ILLUM WITH THE FLAP LEVER IN 1. BOTH FLAP POINTERS ARE CORRECT. L/E SLAT ASYM EICAS DISPLAYED AT FL 340, FLAP INDICATION BETWEEN UP & 1. PREPLACED PSEU PER MM. OP CHECKS GOOD.SDR UALA2010011900236Shutoff Valve · malfunctionedR-HPSOV MSG DISPLAYED ON EICAS. LAX REPORTS BITE FAULTED RT HPSOV & PRESS SENSOR. REPLACED RT HPSOV, ENG NEEDS TO BE RUN AT HIGHER POWER SETTING DUE TO EICAS MSG ON TAKEOFF ROLL.SDR UALA2009122403994Processing Unit · malfunctionedFUEL CONFIG LT -OFF-,NO "FUEL CONFIG" EICAS MSG WITH MAIN TANK UNBALANCE GREATER THAN 1500 LBS. L-R MAIN TANK WAS LOW. BITE CHECK & RESET BEFORE REPLACING PROCESSOR. REPLACED FQIS PROCESSOR UNIT. OPS CHECK OKAY.SDR UALA2009122103941Engine · malfunctionedNO FUEL CONFIG LT W-FUEL IMBALANCE OF 2000 NR R TANK LIGHT. NR 2 ENG BURNS 300 NR MORE THAN NR 1 CHRONIC REPLACED FQIS. OP CHKS NORMAL.SDR UALA2009121503880Light · missingSEAT 2AB EMERGENCY LIGHT MISSING. NEW LIGHT ASSY ORDERED UNDER OSTF Q0769. WILL NOT ARRIVE BEFORE DEPARTURE. REPLACED MISSING LIGHT ASSY. CHECKS OKAY.SDR UALA2009120703789Control Unit · faultyBOTH UTILITY BUSSES SHED WITH APU RUNNING ALL HYD PUMPS OFF. REPLACED BPCU AND APU GCU. SYS OPS CKS NORMAL DURING PWR TRANSFER.SDR UALA2009113003701Igniter · inoperativeAPU WOULD NOT START AFTER 3 ATTEMPTS. ALSO APU FAULT EICAS. BOX BITE NO START WITH NO AUDIBLE IGNITION ON START ATTEMPTS. REPLACED IGNITER PLUG, LEAD AND IGNITION UNIT. APU STARTS NORMALSDR UALA2009110903467Light · brokenEEL STRIP ON SEAT 22H BROKEN. REPLACED EEL LIGHT.SDR UALA2009110403425Fuel Tank · leakingUNWANTED FUEL XFER TO CTR TANK. 3 PREV HITS ALL SINCE TANK WAS ENTERED IN GSO OCT 11. REQ AT LEAST 3-4 SHIFTS FOR TANK ENTRY AT SMB. AT PUSH BACK CTR FUEL READ 0, AT LEVEL OFF WENT TO 1000 NR. LEAK CHECKS GOOD, TANKS AND FUEL PLATE FOR THE SLAT DRAIN ARE CLSDR UALA2009102603328Power Supply · faultyAFT GALLEY EMERGENCY FLOOR LIGHTING AS WELL AS DOOR 2R EXIT LIGHTING FLASHING. EXAMINED WIRING AT SPLICE SM45, CONNECTOR D13244 AND D5086, NO DEFECTS NOTED. REPLACED POWER SUPPLY M1556.SDR UALA2009102603327Power Supply · faultyEMERGENCY EXIT LIGHTS COMING ON AND OFF IN ECONOMY. FLOOR LIGHTS AS WELL AS EXIT LIGHT AT 2L. EXAMINED WIRING AT SPLICE SM23, CONNECTOR D13210, AND D5084 NO DEFECTS NOTED REPLACED PWR SUPPLY M1561.SDR UALA2009102303310Light · unsecureSEAT 2B EEL LIGHTS LOOSE AND HANGING. RIPPED LOOSE FROM CARTS OR ROLLING ONBOARD LUGGAGE. RE-SECURED LIGHTS, OPS CHECK NORMAL.SDR UALA2009102303303Battery · dischargedEMERGENCY FLOOR LIGHTING LAST 6 ROWS ALTERNATINGLY COMING ON, WINDOW SEATING SECTIONS FOUND OVERHEAD EMERGENCY LIGHTS ON FIRST 6 ROWS ON RIGHT SIDE OF AIRCRAFT BY OVERWING EXIT DOORS TO BE MALFUNCTIONING. REPLACED BATTERY IN POWER SUPPLY UNIT M732, OPS CHECK SDR UALA2009102203289Battery · dischargedAISLE EMERGENCY LIGHTS FLICKERING ON IN AFT CABIN DURING FLT. REPLACED BATTERY AT 24AB AND OPS CHECK NOW NORMAL.SDR UALA2009102203288Light · inoperativeEEL LIGHT AT 18HJ IS INOP. INSTALLED NEW LIGHT BAR AND OPS CHECK GOOD.SDR UALA2009102203287Light · inoperativeEEL LIGHT AT 2AB IS INOP. INSTALLED NEW LIGHT BAR AND OPS CHECK GOOD.SDR UALA2009101203194Housing · crackedLEFT OFF WING SLIDE COMPARTMENT DOOR DISCONNECT HOUSING FOUND CRACKED DURING LATCH INSPECTION. INSPECTED 4 EACH LT OFF WING SLIDE COMPARTMENT DOOR LATCHES AND DISCONNECT HOUSING AND FOUND 4 EACH LATCHES GOOD. FOUND DISCONNECT HOUSING CRACKED. REMOVED AND RE