N683FE
Service difficulty reports · 289
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N683FE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N683FE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201112125248Floorboard · damagedAFT CARGO FLOORBOARD 152TF HAS CRUSHED CORE AT EDGE, 2 EA PUNCTURES ON INNER SKIN, AND DAMAGED UPPER PLY. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005.SDR FDEA201112095235Floorboard · crackedFLOORBOARD 252PH HAS ONE 12 INCH CRACK. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201112085217Floorboard · damagedFLOORBOARD 242CK HAS CORNERS BROKEN WHERE CLEVIS ATTACHES 2 CORNERS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005.SDR FDEA201112075206Floorboard · crackedFLOORBOARD 241 GK HAS ONE 12 INCH CRACK. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005.SDR FDEA201112075205Floorboard · damagedFLOORBOARD 242RJ HAS BROKEN EDGES WHERE CLEVIS ATTACHES. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005.SDR FDEA201112065181Floorboard · crackedFLOORBOARD 242 BF HAS SEVEN 10 INCH CRACKS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201112065180Floorboard · crackedFLOORBOARD 242QJ HAS 5 EA, 10" CRACKS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201112065179Floorboard · crackedFLOORBOARD 241GJ HAS TWO 11 INCH CRACKS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005.SDR FDEA201112055169Floorboard · crackedFLOORBOARD 232TG HAS TWO 10 INCH CRACKS, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005-REV J.SDR FDEA201112055168Floorboard · crackedFLOORBOARD 232YG HAS THREE 9 INCH CRACKS, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ-25-005, REV J.SDR FDEA201112055166Floorboard · crackedFLOORBOARD 242 ZJ HAS EIGHT 9 INCH CRACKS, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201112055165Floorboard · crackedFLOORBOARD 252ZG HAS ONE 10" CRACK, FABRICATED FLOORBOARD IAW DWG NR SRZ 25-005- REV J.SDR FDEA201112055164Floorboard · crackedFLOORBOARD 252 HH HAS ONE 9.5" CRACKS, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005 REV J.SDR FDEA201112055163Floorboard · crackedFLOORBOARD 241KJ HAS ONE 11" CRACK, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201112055162Floorboard · crackedFLOORBOARD 241HK HAS 2 EA 12" CRACKS, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201112055161Floorboard · crackedFLOORBOARD 242GF HAS 3EA 10" CRACKS, FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201112055160Floorboard · crackedFLOORBOARD 242UJ HAS 8 EA, 10" CRACKS FABRICATED FLOORBOARD IAW DWG SRZ25-005, REV J.SDR FDEA201112055159Floorboard · crackedFLOORBOARD 242 MF HAS 3 EA 9 INCH CRACKS, FABRICATED FLOORBOARD IAW DWG NR SR 25-005, REV J.SDR FDEA201108243449Handle · failedON DEPARTURE, SLATS WOULD NOT RETRACT. TRIED TO RESET FLAPS AND THEY WOULD NOT GO INTO THE DETENT 15/15. AFTER SEVERAL ATTEMPTS WE GOT THE FLAPS AT 15/20. THE HANDLE NEVER WENT INTO THE DETENT. CAME BACK AND THE SLATS/FLAPS SYS 1&2 FAULT LIGHTS ON THE OVERHSDR FDEA201103211090Pin · failedON TAKE OFF LANDING GEAR WOULD NOT RETRACT. HANDEL WOULD NOT RAISE PASS THE NUTRAL DETENT. AT 14000 FT AND 200 KTS CYCLED GEAR UP AND DOWN TWO TIMES WITH NO PROBLEM. PERFORMED BITE TEST ON PROXIMITY DETECTOR PROCESSING UNIT (54 GB) PER MM 32-31-71-04 SSDR FDEA201103171059Pseu · failedLANDING GEAR WOULD NOT RETRACT AFTER T/O IN SYS 1 OR 2. FOUND PROX BOX INDICATING FAULT ON RT MLG PITCH DAMPER, R&R IAW MM 32-11-15-04.SDR FDEA201008173032Starter · failedWITH 40 PERCENT N1 STABLE SELECTED TO GO NR2 ENGINE DID NOT ACCELERATE LOW SPEED REJECT DUE TO YAW, ON SECOND ATTEMPT STABLE AT 50 PERCENT N1 ROLLING T/O SELECTED TO GO AND HAD NORMAL ACELERATION. STARTER FAILED ON ENG START BY MX-- SUSPECT STARTER, STAYEDSDR FDEA201008123001Autothrottle Sys · malfunctionedIN PROFILE WITH BLUE SPEED LINE AT 290 THROTTLE WENT TO IDLE WOULD NOT HONOR SELECTED SPEED. IN LEVEL CHANGE NO PROBLEMS. AT 10000 FT PROFILE SELECTED SPEED BUG WENT TO 126 & THROTTLE TO IDLE. NO PROBLEM IN LEVEL CHANGE. CATEGORY: C EXPIRATION: 22AUG10 "MESDR FDEA201001210206Controller · failedAFTER TAKEOFF FLAPS SYS 1 AND 2 FAULTED.ALSO HAD FLAPS LIGHT ON SFPI. FLAPS WERE STUCK AND WILL NOT MOVE. REMOVED AND REPLACED NR 1 AND NR 2 SFCC'S IAW MM 27-51-18-4. FLAP/SLAT OPS BITE ON NR 1 AND NR 2 SFCC CHECKS NORMAL IAW MM 27-51-00-5. PERFORMED FLAP/SDR FDEA200906192180Strap · crackedEMPENAGE TAIL SECTION FROM FRAME 85 TO FRAME 86; STRINGER 33R STRAP IS CRACKED. REMOVED OLD CRACKED STRAP AND INSTALLED A NEW STRAP REF SRM 51-40-21; PARA 6 AND 7.SDR FDEA200906192179Stiffener · crackedSTIFFENER AT FRAME 87, STRINGER 32 IS CRACKED. FABRICATED STIFFENER REF SRM 51-31-00 TABLE 3 SHEET 2. ALODINED STIFFENER REF SRM 51-21-10. PRIMED AND PAINTED REF SRM 51-23-10.SDR FDEA200906192178Stiffener · cracked1 EACH STIFFENER AT FRAME 86 NEEDS TO BE FABRICATED, PN A53988661248 IS CRACKED AT STRINGER 32R. FABRICATED STIFFENER REF SRM 51-34-0; TABLE 3; SHEET 2. STOPPED. ALODINED STIFFENER REF SRM 51-21-10 PRIMED AND PAINTED STIFFENER REF SRM 51-23-10.SDR FDEA200906192177Strap · crackedEMPENAGE TAIL SECTION AT FRAME 86; STRINGER 32 STRAP IS CRACKED. REMOVED OLD STRAP AND INSTALLED NEW STRAP REF A300-600 SRM 51-40-21; PARA 6 AND 7.SDR FDEA200906182157Tube · chafedRT WING, RIB 21, OTBD SIDE, INSIDE FUEL TANK, LARGE FUEL TUBING HAS EVIDENCE OF FRETTING AT THE SUPPORT CLAMP. REPAIRED DAMAGE ON FUEL TUBING AT RIB 21 AND 24 IAW EA 2810-127972.SDR FDEA200906182156Tube · chafedRT WING, BETWEEN RIBS 23 AND 24. INSIDE THE FUEL TANK, LARGE FUEL TUBING HAS EVIDENCE OF FRETTING AT THE 2 SUPPORT CLAMPS. REPAIRED DAMAGE ON FUEL TUBING AT RIB 21 AND 24 IAW EA 2810-127972.SDR FDEA200906162125Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED; 231 YG FABRIACTED NEW FLOOR PANEL REF DWG SRZ 25-0056; REV "H". REMOVED DAMAGED FLOR PANEL AND INSTALLED FLOOR NEW PANEL REF AMM 53-10-25-4; PG 3.SDR FDEA200906162124Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED; 252 VF. FABRIACTED NEW FLOOR PANEL REF DWG SRZ 25-0056; REV "H". REMOVED OLD FLOOR PANEL AND INSTALLED NEW FLOOR PANEL IAW AMM 53-10-25-4; PG 3.SDR FDEA200906162123Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED; 242RG REMOVED CRACKED FLOOR PANEL IAW AMM 53-10-25-4; PG 2. FABRICATED NEW FLOOR PANEL AND PART MARKED IAW DWG SRZ 25-0056; REV "H". INSTALLED FLOOR PANEL IAW AMM 53-10-25-4; PG 3.SDR FDEA200906162122Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED; 242 ZJ. REMOVED CRACKED FLOOR PANEL IAW AMM 53-10-25-4; PG 2. FABRICATED NEW FLOOR PANEL AND PART MARKED IAW DWG SRZ 25-0056; REV "H". INSTALLED FLOOR PANEL IAW AMM 53-10-25-4; PG 3.SDR FDEA200906152108Mount Bracket · crackedFWD CARGO COMPARTMENT; AFT FIRE BOTTLE MOUNTING BRACKET IS CRACKED AROUND THE ATTACH HOLES. REMOVED BRACKET AND INSTALLED NEW BRACKET ; LOCATED; DRILLED AND DEBURRED HOLES IAW SRM 51-72-10.SDR FDEA200906152106Housing · crackedLT FUEL TANK NR 9 SLAT TRACK HOUSING IS CRACKED ON THE MOUNT. REMOVED AND REINSTALLED IN REF TO AMM 57-20-43- 4-01. REPAIRED MOUNT IN REF TO FIRST ANGLE PROTECTION DWG A57140552.SDR FDEA200906152114Seat Track · wornMAIN CABIN COMPARTMENT SEAT TRACK IS WORN AT FRAME 44 LBL17. MEASURED SEAT TRACK WEAR TO BE 0.045. ALLOWABLE WEAR FOUND TO BE 0.040. SEAT TRACK FOUND TO BE OUT OF LIMITS. REMOVED OLD SEAT TRACK AND INSTALLED NEW SEAT TRACK REF SRM 51-40-21; PGS 7 AND 24. RSDR FDEA200906152109Floor Panel · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD, 242 UJ, IS CRACKED. REMOVED CRACKED FLOOR PANEL IAW AMM 53-10-25-4; PG 2. FABRICATED AND PART MARKED NEW FLOOR PANEL IAW DWG SRZ 25-005; REV "H". INSTALED NEW FLOOR PANEL IAW AMM 53-10-25-4; PG 3.SDR FDEA200906152105Angle · crackedRT WING INNER CAVITY AREA OF THE FRUGER FLAP; AFT OF THE FIXED L/E; THE INBD LOWER HORIZONTAL ANGLE IS CRACKED. REMOVED LOWER ANGLE ASSY IAW SRM 51-40-21; PG 7. FABRICATED DIAPHRAM; 4 BRACKETS AND 2 SIDE ANGLES IAW DWGS A57242003 AND A572420078. ALODINED PSDR FDEA200906122050Rib · crackedRT INBD FLAP, RIB 25 HAS APPROX 7.0 INCH CRACK IN VERTICAL WEB NEAR UPPER FLANGE, FWD END OF RIB. REMOVED AND REPLACED UPPER RUB STRIP, UPPER SKIN AND AFT SECTION, T/E WEDGE, AND 7 EA WEBS TO FOM. REMOVAL OF RIB 25A REF. SRM 51-40-21 PARA 6 AND FX EO 6-5750-SDR FDEA200906122048Rib · crackedLT I NBD FLAP, RIB 25 HAS APPROX. 4.5 INCH CRACK IN VERTICAL WEB NEAR UPPER FLANGE, FWD END OF RIB. REMOVED AND REPLACED RIB 25A LT INBD FLAP IAW FX EO 6-5750-7-5003 PT 1 INCH WINGS -INBD FLAP - REINFORCEMENT OF RIB 25A.SDR FDEA200906112028Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED; 242MF FABRICATED NEW FLOOR PANEL REF DWG SRZ 25-005; REV "H". REMOVED OLD DAMAGED FLOOR PANEL AND INSTALLED NEW FLOOR PANEL REF AMM 53-10-25-4.SDR FDEA200906112027Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED; 252UH FABRICATED NEW FLOOR PANEL REF DWG SRZ 25-005; REV "H". REMOVED DAMAGED FLOOR PANEL AND INSTALLED NEW FLOOR PANEL REF AMM 53-10-25-4 PG 3.SDR FDEA200906112026Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241GK IS DAMAGED. FABRICATED AND PART MARKED NEW FLOOR PANEL 241 EK PER DWG SRZ 25-005; REV "H" INSTALLED NEW FLOOR PANEL REF AMM 53-10-25-4 PG 3.SDR FDEA200906112025Floor Panel · crackedMAIN CABIN FLOOR PANEL 242EK CRACKED FABRICATED NEW FLOOR PANEL REF DWG SRZ 25-005; REV "H". REMOVED DAMAGED FLOOR PANEL AND INSTALLED NEW FLOOR PANEL REF AMM 53-10-25-4 PG 3.SDR FDEA200906112035Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED. FABRICATED NEW FLOOR PANEL 242BF IAW DWG SRZ 25-005; REV "H". REMOVED AND INSTALLED IAW AMM 53-10-23-4.SDR FDEA200906112034Floorboard · deterioratedMAIN CABIN CARGO COMPARTMENT FLOORBOARD QJ Z242 DETERIORATED/ PUNTURED. FABRICATED NEW FLOOR PANEL 242QJ IAW DWG SRZ 25-005; REV "H". REMOVED AND INSTALLED IAW AMM 53-10-23-4.SDR FDEA200906112033Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED. FABRICATED NEW FLOOR PANEL REF DWG SRZ 25-0056; REV "H". REMOVED DAMAGED FLOOR PANEL AND INSTALLED NEW FLOOR PANEL IAW AMM 53-10-25-4.SDR FDEA200906112032Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED. FABRICATED NEW FLOOR PANEL REF DWG SRZ 25-0056; REV "H". REMOVED OLD FLOOR PANEL AND INSTALLED NEW FLOOR PANEL IAW AMM 53-10-25-4.SDR FDEA200906112031Floor Panel · crackedMAIN CABIN FLOOR PANEL CRACKED. REMOVED CRACKED FLOOR PANEL IAW AMM 53-10-25-4; PG 2. FABRICATED NEW FLOOR PANEL AND PART MARKED IAW DWG SRZ 25-0056; REV "H". INSTALLED FLOOR PANEL IAW AMM 53-10-25-4; PG 3.