N688SL
Service difficulty reports · 160
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N688SL' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N688SL' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR I5PA2026100668801Smoke Detector · faultedMAIN CARGO FIRE AURAL IND ON SHORT FINAL - PERFORMED CFMU BITE. FOUND MAIN CARGO SMOKE DET 1A FAULTED. R & R SMOKE DETECTOR PER AMMSDR I5PA2026092368813Fire Warning · false activationFIRE WARNING ON FINAL WHEN APPROACH MODE WAS ARMED. PERFORMED APPLICABLE FIM, NO FAULTS FOUND. ISSUE FOUND TO BE A FALSE WARNING.SDR I5PA2026092288807Probe · damagedETOPS SIGNIFICANT REPORT, RT ENGINE EGT WENT BLANK. REPLACED RH EGT PROBE IAW AMM DUE TO FINDING ONE LOOSE STUD DURING INSPECTION.SDR I5PA2026092168812Valve · faultyETOPS SIGNIFICANT REPORT, LT ENGINE PNEUMATIC HEALTH CHECK REQUIRED - PERFORMED PNEUMATIC HEALTH CHECK PER AMM, FOUND HPSOV FAULTY. REPLACED HPSOV PER AMMSDR I5PA2026091768811Actuator · inoperativeETOPS SIGNIFICANT REPORT - CABIN AUTO 2 SYSTEM ON MEL - REPLACED OUTFLOW VALVE ACTUATOR PER AMMSDR I5PA2026091468810Ecu · inoperativeETOPS SIGNIFICANT REPORT - APU FAILED TO START. REPLACED APU ECU PER AMMSDR I5PA2026091468809Sensor · inoperativeETOPS SIGNIFICANT REPORT - RIGHT PACK TEMP BITE EICAS MESSAGE. PERFORMED BITE PER AMM, FOUND COMPRESSOR OUTLET TEMP SENSOR FAULT. REPLACED TEMP SENSOR PER AMM.SDR I5PA2026091168808Sensor · inoperativeETOPS SIGNIFICANT REPORT. STANDBY PACK TEMP CONTROL UNIT BITE FAILED. REPLACED LT PACK STANDBY COMPRESSOR OUTLET SENSOR IAW APPLICABLE AMMSDR I5PA2026091068807Reheater · crackedETOPS SIGNIFICANT REPORT, LT PACK REHEATER FOUND CRACKED. REPLACED LT PACK REHEATER IAW APPLICABLE AMM.SDR I5PA2026091068806Control Valve · inoperativeETOPS SIGNIFICANT REPORT. LEFT PACK TEMP EICAS MESSAGE, REPLACED LT PACK TEMP CONTROL VALVE IAW APPLICABLE AMM.SDR I5PA2026090968805Chip Detector · missingETOPS SIGNIFICANT REPORT. RT ENGINE CHIP DETECTOR MISSING DURING INSPECTION. REPLACED RT CHIP DETECTOR IAW APPLICABLE AMMSDR I5PA2026090968804Valve · intermittentETOPS SIGNIFICANT REPORT. APU PNEUMATIC SHUTDOWN VALVE INTERMITTENT. REPLACED APU PNEUMATIC SHUTOFF VALVE PER APPLICABLE AMMSDR I5PA2026090768803Switch · inoperativeETOPS SIGNIFICANT REPORT. APU PNEUMATICS INOP. REPLACED APU GEN DPI SWITCH PER APPLICABLE AMM.SDR I5PA2026090468801Sensor · faultyETOPS SIGNIFICANT REPORT AND EVENT. FLIGHT DECK TEMP REACHED 75 DEGREES FOR OVER AN HOUR. THE MIX MANIFOLD SENSOR WAS REPLACED. THE SUSPECTED UNSERVICEABLE MIX MANIFOLD SENSOR WAS CONFIRMED FAULTY DURING A BENCH CHECKSDR I5PA2026090468814Controller · malfunctionedETOPS SIGNIFICANT REPORT AND EVENT - LEFT PACK TEMP AND CABIN ALTITUDE EICAS MESSAGE. EMERGENCY DESCENT AND DIVERSION TO ROR - PERFORMED BITE CHECK OF PACK TEMP CONTROLLER AND CABIN PRESSURE CONTROLLER PER AMM. NO FAULTS FOUND, ALL MESSAGES CLEARED.SDR I5PA2026090468802Warning Message · illuminatedETOPS SIGNIFICANT EVENT AIR RETURN. LEFT PACK TEMP, FLIGHT DECK TEMP AND CABIN ALT WARNING EICAS MESSAGES. PERFORMED BITE TEST OF PACK TEMP AND CABIN PRESSURE CONTROLLERS, NO FAULTS FOUND. AIRCRAFT RETURNED TO SERVICE.SDR I5PA2026090268801Sensor · faultedETOPS SIGNIFICANT REPORT AND EVENT, LT PACK TEMP AT FL 310, AIRCRAFT DIVERTED TO MNL. REPLACED LT PACK TEMP SENSOR IAW AMM.SDR I5PA2026083068810Adc · faultedETOPS SIGNIFICANT REPORT, CAPT AND FO AIRSPEED INDICATION INOPERATIVE. REPLACED LT AND RT AIR DATA COMPUTERS IAW AMM.SDR I5PA2026083068809Controller · inoperativeETOPS SIGNIFICANT REPORT, CABIN ALT AUTO 2 STATUS MESSAGE. REPLACED CABIN PRESSURE CONTROLLER 2 IAW AMM.SDR I5PA2026083068808Circuit Card · inoperativeETOPS SIGNIFICANT REPORT, LT ENGINE FIRE LOOP 1 STATUS MESSAGE. REPLACED AFOLTS NR 1 CARD IAW AMM.SDR I5PA2026083068807Igniter · wornETOPS SIGNIFICANT REPORT, RT ENGINE UPPER IGNITER PLUG WORN. REPLACED IGNITER PLUG IAW AMM.SDR I5PA2026083068806Skin · corrodedCORROSION DISCOVERED ON EMPENNAGE AREA FWD OF APU. REPAIRED IAW EO APA-0046-023.SDR I5PA2026083068805Skin · corrodedCORROSION DISCOVERED ON RT WING LOWER SKIN AND FLAP UPPER SKIN. REPAIRED THE SKIN IAW EO APA-0046-019, -020, -021, -024, & -025.SDR I5PA2026083068804Skin · corrodedCORROSION DISCOVERED ON LT WING LOWER SKIN AND FLAP FWD SPAR. REPAIRED THE SKIN IAW EO APA-0046-017, -018 AND -035.SDR I5PA2026083068803Shear Web · corrodedCORROSION DISCOVERED ON LAV FLOOR SHEAR WEB. REPAIRED THE SHEAR WEB IAW EA 26-1008, & 26-1008-SR.SDR I5PA2026083068802Skin · corrodedCORROSION DISCOVERED ON RT HORIZONTAL STAB UPPER SKIN. REPAIRED THE STAB SKIN IAW EO APA-0046-011, -012, -013, -014, -015, & -016.SDR I5PA2026083068801Skin · corrodedCORROSION DISCOVERED ON LT HORIZONTAL STAB UPPER SKIN. REPAIRED THE SKIN IAW EO APA-0046-001, -002, -003, -004, -005, -006, -007, -008, -009, -010, & -036.SDR I5PA2026020168804Outflow Valve · faultedOUTFLOW REQUIRES MANUAL OPERATION TO OPEN ON THE GROUND. R & R OUTFLOW VALVE ACTUATOR IAW AMM 21-31-04.SDR I5PA2026013068803Pilot Valve · faultedDEFERRED RT ENG HPSOV IAW MEL 36-11-02. R & R RT ENG HIGH STAGE PILOT PER AMM 36-11-08.SDR I5PA2026012768802Starter · faultyAPU FAULT. R & R APU STARTER IAW AMM 49-41-01. OPS CHECKED NORMAL.SDR I5PA2026011988801Anti-Ice Valve · stickingLEFT ENG ANTI-ICE VALVE STICKING. R & R LT ENG ANTI-ICE VALVE IAW AMM 30-21-03. OP CHECKED NORMAL.SDR I5PA2025121168801Landing Gear · malfunctionedLEFT MAIN GEAR DID NOT RETRACT AFTER TAKEOFF. AIRCRAFT AIR RETURNED BACK TO HNL. MX PERFORMED FIM PROCEDURES WITH MULTIPLE FUNCTION CHECKS. NO DEFECTS NOTED. FUNCTIONAL FLIGHT PERFORMED. LANDING GEAR OPS CHECKED NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR I5PA2025101268801Ecu · faultyFLT: MGE820, APU FAULT, QRH PERFORMED AND RESTART OK. R & R APU ECU IAW AMM, OPS CHECK NORMAL. NO FAULTS ON ECU.SDR I5PA2025092968806Switch · inoperativeAPU GENERATOR SWITCH INOPERATIVE. REPLACED APU GENERATOR SWITCH PER AMM.SDR I5PA2025092568805Module · faultedAPU PNEUMATICS INOP. R & R APU FLOW SENSING MODULE PER AMM. OPS CHECK NORMAL.SDR I5PA2025092848804Apu · faultyAPU PNEUMATICS INOP. PERFORMED AU ECU BITE PER FIM 49-22 FT 866. P2 SENSOR HARD FAULT. R/R P2 SENSOR PER AMM, NO HELP. PERFORMED WIRING CHECK OF APU SYST. PER WDM NO DEFECTS FOUND. R/R APU PER TASK CARD. OPS CHECK NORMAL.SDR I5PA2025091768802Exciter · inoperativeRIGHT ENGINE IGNITION SYSTEM 1 INOP. PERFORMED OPS CHECK, FOUND SYSTEM 1 EXCITER INOP. REPLACED IGNITION EXCITER PER APPLICABLE AMM.SDR I5PA2025091768801Ignition Lead · damagedRIGHT ENGINE IGNITION SYSTEM 1 INOP. PERFORMED FIM, FOUND SYSTEM 1 IGNITION LEAD DAMAGED. REPLACED IGNITION LEAD PER APPLICABLE AMM.SDR I5PA2025083168804Transmitter · faultyAPU OIL QTY STATUS MSG. R & R APU OIL QTY TRANSMITTER PER AMM, OPS CHECK NORMAL.SDR I5PA2025082168803Apu · inoperativeAPU INOPERATIVE. R & R APU IAW AMM.SDR I5PA2025081368802Sensor · faultyFLT NO: MGE300, LEFT ENG BLEED OFF ON T/O, AIR RETURN HNL. MX PERFORMED FIM 36-10 FT 817, FOUND LH ENG PRECOOLER OUT TEMP FAULTY. R/R FAN AIR TEMP SENSOR PER AMM. PERFORMED PNEUMATIC HEALTH CHECK NO FAULTS NOTED.SDR I5PA2025080568801Window · crackedFLT NR MGE 300, L1 WINDOW CRACKED FLT 340, AIR RETURN HNL. R & R L1 WINDOW IAW AMM 56-11-01. ACFT RETURN TO SERVICE.SDR I5PA2025071168803Pilot Valve · faultedRIGHT HS PILOT FAILED PNEUMATIC HEALTH CHECK. R & R RH HS PILOT PER AMM. PERFORMED HEALTH CHECK. OPS CHK OK.SDR I5PA2025071168802Shutoff Valve · faultedRIGHT HPSOV FAILED PNEUMATIC HEALTH CHECK. R & R RH HPSOV PER AMM. PERFORMED HEALTH CHECK. OPS CHK OK.SDR I5PA2025071068801Isolation Valve · faultedFLT NO: MGE410, BLEED ISOLATION VALVE EICAS MSG, VALVE STUCK OPEN. PERFORMED BITE FIM 36-10 FT 809. R & R ISOLATION VALVE PER 36-11-04. OPS CHECK NORMAL.SDR I5PA2025062868807Display · faultedFLT: MGE600, F/O ATTITUDE DISPLAY BLANKED OUT DURING CLIMB OUT TO FLIGHT LEVEL. AIR RETURN BACK TO HNL. R & R F/O FLAT PANEL DISPLAY PER FDS-ICA ID-07688. OPS CHECK NORMAL. ACFT RETURNED TO SERVICE.SDR I5PA2025062768806Igniter · faultedFLT: MGE 300, ESI. APU FAULT ON TAXI IN. TROUBLESHOT PER FIM 49-11 FT 852. R & R APU IGN PLUG. OPS CHK OK.SDR I5PA2025062768805Exciter · faultyFLT: MGE 300, ESI. APU FAULT ON TAXI IN. TROUBLESHOT PER FIM 49-11 FT 852. R/R APU IGN EXCITER. OPS CHK OK.SDR I5PA2025061768804Converter · faultedLEFT ENG EPR FLUX ON CLIMB. R/R LH ENG 14TH STAGE BLEED CONVERTER PER AMM. OPS CHECK NORMAL PER AMM.SDR I5PA2025061368803Pilot Valve · faultyLEFT ENG BLEED VAL ON EICAS W/ ENG ANTI ICE ON DURING CLIMB. PERFORMED PNEUMATIC HEALTH CHECK PER AMM. HS PILOT FAILED TEST. R/R HS PILOT PER AMM. OPS CHECK OK.
Back to N688SL