N692NK
Service difficulty reports · 47
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N692NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N692NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2024110838512Bottle · low pressureL1 & R2 DOOR ASSIT BOTTLE REQUIRE SERVICE-SERVICE L1 & R2 DOOR ASSIT BOTTLE IAW AMM 52-10-00 TO PROPER LEVELSDR GTIA2024102838491Unknown · odorSMOKE / BURNING SMELL COMING FROM FWD GALLEY / FAP PANEL -PER MOC PERFOERED GVI OF WIFI R&R RECP FILTERS , EPSU, COFFEE MAKERS, LAV WATER HEATER SEE L/P 3604613-2 THRU 360418-2 IAW TSM 05-50-00 PERFORMED ENG RUN WITH PACKS ON AND OFF IAW AMM 71-00-00 NO ODOR DSDR GTIA2024102838487Unknown · odorFLIGHT ATTENDANT REPORT OF ELECTRICAL BURNING SMELL BETWEEN ROWS 7ABC-11ABC-PERFORMED INSPECTION IAW TSM 05-50-00 NO DEFECTS NOTED UNABLE TO DUPLICATE AT THIS TIME A/C OK FOR CONTINUED SERVICESDR GTIA2024101238439Deck Plate · damaged"GALLEY G4 WORKDECK RAF 01-3337210-2 GENERATED -GALLEY G4 WORKDECK REPLACED IAW EC 2533-015"SDR GTIA2024080538273Bottle · low pressureDURING SERVICE CHECK, FOUND L1 AND R2 DOOR ASSIST BOTTLES LOW-SERVICED L1 AND R2 DOOR ASSIST BOTTLES IAW AMM 52-10-00.SDR GTIA2024070938221Bottle · low pressureR2 DOOR ASSIST BOTTLE REQ SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2024042338077Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW.-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2024031237981A/C Pack · odorBELOW 10,000 GOT DIRTY SOCK SMELL REPORTED BY THE FA. AFTER TAKEOFF RAN ELIMINATION OF ODER QRH- ODOR WENT AWAY, PACK 1 OFF, X BLEED SHUT-PERFORMED PACK BURNOUT IAW AMM 21-00-00. OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. A/C GOOD FOR SVC.SDR GTIA2024031237980Unknown · odorSUSPECTED FUME EVENT ON APPROACH TO MCO AT APPROX 5000FLT FA REPORTS DIRTY SOCK SMELL ALSO NOTICED BY REST OF CREW.SMELL REMAINED NOTICEABLE DURING TAXI UNTIL ENG 2 SHUTDOWN.2 PAX/FA SICK-PERFORMED AIR QUALITY EVENT IN REF TO TI 2100-2002-CEO ALSO PERFORMED DESDR GTIA2023102737564Lavatory · inoperativeALL LAVS WILL NOT FLUSH ALL ALTITUDES-REMOVED AND INSTALLED LIQUID LEVEL TRANSMITTER TO WASTE TANK IAW AMM 38-32-00. LEAK CHECK GOOD. PERFORMED LAVS OPS CHECK IAW AMM OPS CHECK GOOD AC GOOD FOR SVC.SDR GTIA2023081037401Manifold · overtempBRAKES HOT # 2 REACHED 980C 3&4 WERE OVER 500C FELT AS IF BRAKES WERE RUBBING-R + R ALTERNATE BRAKE MANIFOLD (2853GM) IAW AMM 32-43-32. OPS TEST AND LEAK TEST GOODSDR GTIA2023071037322Unknown · unknownR2 PASSENGER DOOR ASSIST BOTTLE NEEDS SERVICING-SERVICED R2 PASSENGER DOOR IAW AMM 52-10-00SDR GTIA2023032737076Unknown · unknownL1 DOOR ASSIST ACCUMULATOR @ 1400-SERVICED L1 DOOR ASSIST ACCUM. REF. AMM 52-11-14SDR GTIA2023032737075Unknown · unknownDOOR ASSIST ACCUMULATOR @ R2 @ 400PSI-SERVICED R2 DOOR ASSIST ACCUM. REF. AMM 52-11-14SDR GTIA2023032337066Unknown · unknownDURING TAKEOFF UNABLE TO BRING UP GEAR. THEN GOT VENT EXTRACT FAULT. NO LANDING GEAR ECAM INDICATION.--SDR GTIA2022121936838Flashlight · inoperativeFWD RH CABIN FLASHLIGHT INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R FLASHLIGHT ASSY IAW AMM 25-65-00. THIS CLEARS MDDR 44395. PLACARD REMOVED. MOC NOTIFIED.SDR GTIA2022091936671None · noneR2 DOOR ASSIST BOTTLE REQUIRES SERVICING -SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022091936669Lavatory · inoperativeDIVERTED TO DEN BECAUSE ALL LAVS INOP IN FLIGHT-PERFORMED OPS TEST OF THE WASTE WATER DRAIN SYS PER AMM 38-32-00-710-002-A OPS CHECK GOOD AT THIS TIME NO FURTHER DEFECTS NOTED ALL LAVS NOW OPERATE AS DESIGNED ACFT OK FOR SERVICESDR GTIA2022081536583None · noneDURING WEEKLY CHECK FOUND R2 DOOR ASSIST REQ SERVICE-SERVICED R2 DOOR ASSIST IAW AMM 52-10-00SDR GTIA2022032836353None · noneL1 AND R2 ENTRY DOORS ASSIST BOTTLE REQUIRE SERVICING-SERVICED L1 AND R2 ENTRY DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022032836349Flashlight · inoperativeFWD FAS FLASHLIGHT INOP-R&R FWD F/AS FLASHLIGHT IAW CMM 25-60-02. OPS CK GOODSDR GTIA2022013136251Not Reported · not reportedDURING WEEKLY FOUND L1 AND R2 DOOR ASSIST PRESSURE REQ SERVICE-SERVICED L1 AND R2 DOOR ASSIST IAW 52-10-00.SDR GTIA2022011736221Not Reported · not reportedL1 DOOR ASSIST BOTTLE AND R4 DOOR ASSIST BOTTLE REQUIRES SERVICING. -SERVICED L1 DOOR ASSIST BOTTLE AND R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2021102136059None · inoperativeWX RADAR INOP.-R&R TRU (13SQ1) OPS CHECK OK REF AMM 34-41-51SDR GTIA2021091635989Bottle · low pressurePER WEEKLY FOUND L1 AND R2 DOOR EMER ASSIST BOTTLE REQ SERVICE -SERVICE L1 AND R2 DOOR EMER ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021082635947Bottle · low pressureR2 DOOR ASIST ACCUMULATER REQUIRES SERVICE-SERVICED R2 DOOR ASIST BOTTLE IAW AMM 52-10-02SDR GTIA2021062135821Bottle · low pressureR4 DOOR ASSIST BOTTLE REQUIRES SERVICING.-SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK + OPS TEST OK.SDR GTIA2021061035795Bottle · low pressure"R2 DOOR REQ SERVICE ON DOOR ASSIT -SERVICED R2 DOOR IAW AMM 52-10-00.SDR GTIA2021061035794Bottle · low pressure"L 1 DOOR REQ SERVICE ON DOOR ASSIT -SERVICED L1 DOOR IAW AMM 52-10-00.SDR GTIA2021040135666Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW.-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001SDR GTIA2021031235636Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021030435623Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2021020135577Bottle · low pressureDURING WEEKLY CHECK FOUND L2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR IAW AMM 52-10-00 LEAK CHECK GOOD.SDR GTIA2020113035477Bottle · low pressureRT AFT DOOR ASSIST BOTTLE REQUIRES SERVICE. SERVICED RT AFT DOOR ASSIST BOTTLE, IAW AMM 52-10-00.SDR GTIA2020112335462Bottle · low pressureR2 DOOR ASSIST BOTTLE PRESS IS LOW. SERVICE R2 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.SDR GTIA2020030235060Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW-SVC R2 DOOR ASSIST BOTTLE TO PROPER LVL IAW AMM 52-10-00. LEAK CHK GOODSDR GTIA2020012034951A/C Pack · fumesFUME EVENT ON APPROACH TO LANDING. PERFORMED T/S IAW TSM 05-50-00, ISOLATED PACK 1.SDR GTIA2020011634946Bottle · low pressurePASSENGER/ CREW DOOR R2 DOOR ASSIT BOTTLE NEEDS SERVICING. SERVICED THE PASSENGER / CREW DOOR R2 DOOR ASSIT BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2019120524830Lever · malfunctionedLGCIU 1 + 2 FAULT-R/R LANDNG GEAR LEVER IAW AMM 32-31-11. OPS CHECK GOODSDR GTIA2019083084581Seat · odorPAX REPORT EXTREMELY OFFENSIVE ODOR COMING FROM DEFERRED SEAT 4C. ( PASSENGER SEAT(S) PASSENGER SEAT(S) )--SDR GTIA2019081204548Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2019080334531Bottle · low pressureR2 DOOR ASSIST ACCUMULATOR LOW-SERVICED R2 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2019080134519Bottle · low pressureR2 DOOR ASSIST BOTTLE AT 250 PSI. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2019052903375Assist Assy · low pressureR2 DOOR ASSIST REQUIRES SERVICING. SERVICED R2 DOOR ASSIST IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2019050803334Bottle · low pressureR2 DOOR ASSIST BOTTLE NEED SERVICE. SERVICED TO PROPER LEVEL R2 DOOR ASSIST BOTTLE IAW AMM 52-22-00.SDR GTIA2019040853271Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2019022183167A/C Pack · odorCLIMBING OUT OF IAH. FA REPORTED AIR QUALITY EVENT IN AFT CABIN-FOLLOWED TSM 05-50-00 FOR CAUSE OF ODOR OR SMOKE, CHECKED ENGINES + APU FOR SIGNS OF LEAKAGES REF TSM 71-00-00 + 49-00-00 NONE NOTED. ENIGINES RAN BY FLT CREW ISOLATING BLEEDS WHILE OPERATING BOTH
Back to N692NK