N694AE
Service difficulty reports · 191
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N694AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N694AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20210118001Cradle · brokenAFT EMERGENGY FLASHLIGHT CRADLE BROKEN MEL 2553-AUTH 01-193-C. C/A: R & R AFT EMERGENCY FLASHLIGHT AND CRADLE ASSEMBLY, IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPERATIONS CHECK GOOD. MEL RESTORED.SDR SIMA20210111002Cradle · brokenAFT EMERGENCY FLASHLIGHT CRADLE BROKEN. C/A: DEFERRED PER MEL 25-53 AUTH 010193-C EXP 01/22/21 M PROCEDURES COMPLIED WITH.SDR SIMA20201022002Light · inoperativeMAIN DOOR EXTERNAL EMERGENCY LIGHT INOPERABLE. C/A: R & R MAIN DOOR EXTERNAL EMERGENCY LIGHT, IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPERATIONS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA20200920003Switch · failedTAXING INTO DFW FOS' PUSH TO TALK BUTTON ON. CONTROL YOKE STARTED SMOKING HAD SMOKE AND ELECTRICAL SMELL IN COCKPIT. C/A R & R FO'S AP/TRIM/PUSHER DISC SWITCH, IAW EMB145 AMM 22-11-07. AP FUNCTIONAL TEST GOOD, IAW EMB145 AMM 22-11-00.SDR SIMA202009076005Lamp · inoperativeDURING PS-1 CHECK FOUND RT EXTERNAL EMERGENCY ABOVE WING INOPERABLE. C/A-RAR RT EXTERNAL EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPERATIONS CHECK GOOD.SDR SIMA20200827002Pressure Switch · malfunctionedDURING CLIMB RUDDER SYSTEM 1-2 INOP DECLARED EMERGENCY FLIGHT CONTINUED-C/A-FOLLOWED FIM TASK 27-22-00-810-804-A . RAR #2 RUDDER PRESSURE SWITCH IAW EMB-145 AMM 27-23-04. OPS CHEK GOOD IAW EMB-145 AMM 27-23-00.SDR SIMA202007243003Roller · fodMAIN CABIN DOOR STICKS WHEN OPENING FA NEEDED HELP TO OPEN. CLEANED FOD FROM MAIN CABIN DOOR ROLLERS REF 52-18-00. DOOR OPERATES GOOD IN REF TO E145 AMM 52-18-00SDR SIMA202007186002Cabin Pressure · malfunctionedDURING ICE PROTECTION TEST (PNEUMATIC IN FLIGHT) DURING CLIMB AT FL190, PRESSURIZATION EXPIRENCED ABNORMAL CABIN RATE FLUCUATIONS. QRH PROC COMPLIED WITH. NEITHER AUTO OR MANUAL CONTROL OF CABIN POSSIBLE. IN MAN MODE CABIN RATE FLUCUATED AND WAS UNRELATED TO MSDR SIMA202006154002Engine · odorSUPPLMENTAL BURNING SMELL PRESENT AT LOW ALTITUDE, BURING PLASTIC OR RUBBER. C/W FIM TASK 21-20-00-810-801 STEPS 1-10. NO FAULTS FOUND AT THIS TIME. PERFORMED DVI OF LT & RT RELAY PANELS LOOKING FOR DAMAGE, BURNT ITEMS & SMOKE SMELL. NO DISCREPANCIES FOUND ATSDR SIMA202005264002Fan · failedSMELL OF BURNING ELECTRONICS IN COCKPIT. C/A-REMOVED AND REPLACED LT RECIRCULATION FAN IAW 21-24-01. OPS CK AND LEAK CK GOOD. REMOVED AND REPLACED FUSE F0060 IAEW 20-13-08. REMOVED AND REPLACED RT RECIRCULATION FAN IAW AMM 21-24-01 OPS CHECK GOOD, LEAK CHECK GSDR SIMA20200520003Duct · unsecureSUPPLEMENTAL FOUL SMELL COMING STRONG OUT OF FRONT AIRPLANE VENTS (DIRTY SOCK) OZONE STALE SMELL PACK1 ASSOCIATED. DEFERRED PACK 1 IAW MEL 21-30 AUTH 050203-D-C EXPIRATION 5/30/2020. FOUND DUCT OFF ON LT RAM AIR VALVE. RESECURED DUCT IAW AMM 21-25-01-04. OPS CSDR SIMA20200417001Charger · failedREMOVE AND REINSTALL #1 EMERGENCY BATTERY POWER SUPPLY -C/A-REMOVED AND REPLACED THE #1 BATTERY AND CHARGER IAW EMB 145 AMM 33-50-04, SYS CKS GOOD.SDR SIMA2020041716003Frame · gougedFR 65 Z FRAME IS GOUGED AROUND 7 SCREW HOLES LH SIDE-C/A-PERFORMED REPAIR TO FR 65Z IAW ERS-EM-53MR-4084 REV1.SDR SIMA2020041614003Floor Support · corrodedSSI 53-20-11 LH OMEGA BEAM SIDEWALL IS PITTED ABOVE CROSSBEAM AT FR 44.-C/A-ACCOMPLISHED LH OMEGA BEAM REPAIR IAW ENVOY ERS-EM-53MR-4089SDR SIMA2020041614004Floor Support · corrodedSSI 53-20-11 LH OMEGA BEAM CORRODED ON THE SIDE AT FR 29 CROSS BEAM-C/A-ACCOMPLISHED LH OMEGA BEAM REPAIR IAW ENVOY ERS-EM-53MR-4090SDR SIMA20200413002Wire · brokenFLOOR PROXIMITY LIGHT STRIP # 6 WIRE BROKE OFF LIGHT.FOUND ON CLOSE UP.-C/A-REMOVED AND REPLACED FLOOR PROXIMITY LIGHT STRIP # 6 IAW EMB 145 AMM 33-50-12. SEE NRTC BOW339262 FOR OPS CHECK.SDR SIMA20200413001Wire · brokenEMERGENCY LIGHT STRIP WIRE AFT OF CONNECTOR SP9115 HAS BROKEN STRANDS MARKED. FOUND ON CLOSE UP.-C/A-REPAIRED WIRE W192-8760-22 AFT OF SPLICE SP9115 IAW EMB 145 SWPM 20-21-00.SDR SIMA20200413003Wire · damagedEMERGENCY LIGHT STRIP WIRE AFT OF CONNECTOR SP9036 HAS DAMAGED INSULATION.FOUND ON CLOSE UP.-C/A-REPAIRED WIRE INSULATION ON W192-8679-22 AFT OF SPLICE SP9036 IAW EMB 145 SWPM 20-21-00.SDR SIMA2020041305001Rib · crackedLH WING RIB 21 IS CRACKED INSIDE PANEL 551CB-C/A-INSTALLED REPAIR (DOUBLER,FILLER,SHIM) FOR LH WING RIB 21 INSIDE PANEL 551CB IAW EMB 145 SRM 57-20-07,FIGURE 203SDR SIMA2020041302010Structure · damagedLAVATORY BUCKET MOUNTING FLANGE FOUND TO HAVE MULTIPLE ELONGATED HOLES AT INBOARD SIDE-C/A-INSTALLED NEW LAVATORY BUCKET MOUNTING FLANGE DIGITAL IAW EMB 145 SRM 51-40-02.SDR SIMA2020041302009Floor Support · corrodedSSI 53-20-11 LH OMEGA BEAM CORRODED AT CROSS BEAM BTW FR 33-34-C/A-INSTALLED REPAIR DOUBLER FOR LH OMEGA BEAM AT CROSS BEAM BTW FR 33-34 IAW EMB 145 SRM 53-22-10RE, FIGURE 203SDR SIMA2020040602006Web · crackedSSI 52-30-08 CORROSION ON CARGO DOOR WEBBING. (3 EACH MARKED)-C/A-PERFORMED DOUBLER REPAIR ON CARGO DOOR WEBBING IAW EMB145 SRM 52-30-01 AND ETN-EM-52-043SDR SIMA202004031003Door Sill · corrodedSERVICE DOOR CUTOUT STRUCTURE ENTRENCE SILL HAS CORROSION AT NUT PLATE HOLES-C/A-REMOVED AND REPLACED THE SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.SDR SIMA2020042022007Skin · crackedCARGO DOOR SKIN IS CRACKED NEAR EXTERNAL HANDLE-C/A-PERFORMED PERMANENT REPAIR TO CARGO DOOR SKIN CRACK NEAR EXTERNAL HANDLE IAW ERS-EM-52MR-1074SDR SIMA2020040622005Skin · crackedCARGO DOOR SKIN IS CRACKED NEAR EXTERNAL HANDLE-C/A-INSTALLED REPAIR FILLER AND DOUBLER IAW EMB 145 SRM 52-30-01SDR SIMA2020040622006Shear Tie · corrodedSSI 53-30-48 FR 65 SHEAR CLIP IS CORRODED BETWEEN STR 17L-16L-C/A-PERFORMED SPLICE REPAIR PER SRM 53-31-04, FIGURE 212SDR SIMA2020033022004Frame · crackedFR 73 IS CRACKED BETWEEN STR 17R-16R-C/A-REMOVED AND REPLACED FR 73 BTW FR 17L-15R IAW EMB145 SRM 51-40-02.SDR SIMA2020032320002Mount Bracket · crackedLH PYLON FWD LOWER YOKE FWD ENGINE MOUNT BRACKET IS CRACKED-C/A-ACCOMPLISHED REPAIR OF LH PYLON FWD LOWER YOKE FWD ENGINE MOUNT BRACKET IAW ENVOY ERS-EM-54MR-698SDR SIMA2020041319008Structure · corrodedLAV BUCKET INSIDE WASTE PANEL HAS CORROSION-C/A-APPLIED SEALANT AND INSTALLED SERVICEABLE LAV BUCKET IAW EMB 145 SRM 51-20-01 AND 51-40-02.SDR SIMA2020040619007Door Sill · corrodedSSI 53-30-48 CARGO DOOR LOWER SILL IS CORRODED-C/A-REMOVED AND REPLACED CARGO DOOR LOWER SILL IAW EMB 145 SRM 51-40-02.SDR SIMA202002032001Wire · broken#7 EMER FLOOR LIGHT STRIP, WIRE BROKEN-C/A-REMOVED AND REPLACED #7 EMER LIGHT STRIP IAW EMB 145 AMM 33-50-12SDR SIMA202002031003Wire · broken#5 EMERGENCY LIGHT STRIP HAS A BROKEN WIRE A/C SIDE-C/A-REPAIRED #5 EMERGENCY LIGHT STRIP IAW EMB 145 SWPM 20-50-00. OPERATIONAL CHECK GOOD.SDR SIMA202002031002Wire · brokenNUMBER 7 EMERGENCY LIGHT, WIRE BROKEN.-C/A-REMOVED AND REPLACED NUMBER 7 EMERGENCY LIGHT IAW EMB 145 AMM 33-50-12. OPS CHECK GOOD.SDR SIMA202001298002Charger · inoperativeLH FWD OVER WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH FWD OVER WING EMERGENCY LIGHT LAMP IN REFERANCE WITH 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. REMOVED AND REPLACED EMERGENCY LIGHT ASSEMBLY IAW 33-50-10-000-801-A AND 33-50-10-400-801-SDR SIMA202001065001Apu · fumesFUMES DETECTED IN COCKPIT AND CABIN OF ELECRICAL AND OR OIL IN SOURCE.-C/A-ACCOMPLISHED FIM TASK 21-20-00-810-803-A AND ETN EM-72-034, FOUND APU TO BE CAUSE OF OIL FUMES IN COCKPIT WITH PACK 1 ON. DEFFERED APU "M PROCEDURES COMPLIED WITH" AUTH 010215DM-C REF 4SDR SIMA201912021003Unknown · odorAIR CONDITIONING PACK NR 1 PRODUCING AN OILY SMELL & NOT COOLING VERY WELL. PERFORMED A NR 1 PACK OPS CHECK IAW AMM 21-51-00. PERFORMED ETN -EM -72-034-ENG ODOR EVENT TROUBLESHOOTING. NO ODOR WAS DETECTED AND SYS WAS COOLING PROPERLY. OPS CHECKED GOOD. NSDR SIMA2019101430002Inverter · inoperativeOVERWING EMERGENCY EXIT CEILING AFT SIGN INOP. REMOVED AND REPLACED #4 EMERGENCY LIGHT DC/AC INVERTER IAW EMB 145 AMM 33-50-11. OPC GOODSDR SIMA20190527002Acm · failedPACK 2 OVHTIN FLIGHT RESOLVED WITH QRH UPON LANDINGPACK 1&2TEMP CONTROL UNRESPNSIVE WITH EITHER BLEED CONFIG AND RUBBER SMELL. C/A-C/W EO EM-2100-048, REMOVED AND REPLACED #1 ACM AND CONDENSER/MIXER IAW AMM 21-51-03 AND 21-51-04, PERFORMED ODOR EVENT TROUBLESHSDR SIMA20190205001Light · inoperativeFLOOR EMERGENCY PROX LIGHT STRIP BETWEEN SEATS 7 THROUGH 9 INOP. REMOVED AND REPLACED FLOOR EMERGENCY PROX LIGHTS STRIP BETWEEN SEATS 7 THROUGH 9 IAW AMM 33-50-12. OPS CHECK GOOD.SDR SIMA2018121412006Cradle · brokenFWD CABIN FLASHLIGHT CRADLE BROKEN-C/A-RAR FWD CABIN FLASHLIGHT CRADLE IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A..NO FURTHER DEFECTS NOTED AT THIS TIME END.SDR SIMA201811263004Lamp · inoperativeCOCKPIT EMERGENCY LIGHT INOP-C/A-RAR LAMP IN COCKPIT EMERGENCY LIGHT ASSEMBLY IAW EMB AMM 33-50-05-000-801-A AND 33-50-05-400-801-A OPC GOODSDR SIMA201810087005Cradle · brokenAFT FLASH LIGHT CRADLE BROKEN. -C/A-REMOVED AND REPLACED AFT CABIN FLASHLIGHT ASSY IAW AMM 33-50-16-000-801-A/33-50-16-400-801-A OPC GOOD.SDR SIMA201809121002Flashlight · damagedFA FLASHLIGHT DAMAGED. REMOVED AND REPLACED FA LASHLIGHT ASSY IAW AMM 33-50-16 OPS CHECK GOOD.SDR SIMA201806253003Smoke Warning · false activationLAVATORY SMOKE WARNING MESSAGE DURING FLIGHT. FLIGHT ATTENDANT STATED NO EVIDENCE OF FIRE, FUMES, OR SMOKE. COMPLIED WITH AN OPS CHECK OF THE LAVATORY SMOKE DETECTION SYSTEM. OPS CHECKED GOOD IAW AMM 26-14-00.SDR SIMA20180402001Power Supply · defectiveLEFT FWD LOWER EXTERIOR EMERGENCY LIGHT INOPERATIVE, TROUBLESHOT THE EMERGENCY LIGHT IAW WM 33-50-50, FOUND THE NR 1 EMERGENCY LIGHT POWER SUPPLY DEFECTIVE. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-50-04. OPS CHECKED GOOD.SDR SIMA20171124001Skin · damagedNUT PLATE FOR PROTRACTOR MOUNT POINT MISSING, RIVETS PULLED THROUGH RUDDER SKIN. CUT OUT THE DAMAGED SKIN, FABRICATED A FILLER AND DOUBLER AND INSTALLED A NEW NUT PLATE IAW SRM 55-40-01.SDR SIMA20171122001Sign · inoperativeAFT SIDE OF CENTER AISLE CEILING EMERGENCY EXIT LIGHT WILL NOT ILLUMINATE. REPLACED CENTER AISLE AFT EXIT LOCATING SIGN ASSEMBLY AND PERFORMED OPERATIONAL TEST. OPERATIONAL TEST GOOD IAW AMM 33-50-15 AND 33-50-00SDR SIMA20171120001Wire · damagedWIRE CONNECTORS FOR CABIN FLOOR LIGHTING STRIPPED FROM WIRES BETWEEN FRAMES 58-59, STRINGERS 19-21L, UNDERNEATH FLOOR PANEL 251HF. REPAIRED WIRING FOR EMERGENCY LIGHT AT FRAME 58-59 IAW SWPM 20-21-00, LIGHT OPS CHECK GOOD IAW AMM 33-50-00-700-801.SDR SIMA20171118002Shear Tie · corrodedCORROSION ON THE SHEAR TIE AT FRAME 60, BETWEEN STRINGERS 20R - 21R. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02.SDR SIMA2018082429009Bushing · missingPAX DOOR HINGE ARM FRAME SIDE TOP UPPER FITTING BUSHING MISSING-C/A-REAMED PAX DOOR HINGE ARM FRAME SIDE TOP UPPER FITTING BUSHING TO .5938 DIAMETER TO INSTALL NEW OVERSIZED BUSHING IAW EMB 145 SRM 52-18-02. FABRICATED REPAIR BUSHING IAW SRM 52-18-02,INSTALLED