N703KW
Service difficulty reports · 57
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N703KW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N703KW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2DYA202609070023Battery Pack · dischargedR2 DOOR FLASHLIGHT NOT BLINKING. BATTERY PACK ORDERED. PLACED ON MEL 25-63-04-04A CAT "C" EXP. 19-SEP-26 DMI 703-26-0074. 9-SEP-26 LP 50753.SDR 2DYA202608230022Battery Pack · depletedDURING LINE CHECK L3 AISLE EXIT SIGN INOP. REMOVED AND REPLACED BATTERY PACK W/OH UNIT P/N ON: ABS-2012-1A S/N: 77501 IAW B767 AMM 33-51-07.OPS CHECKED GOOD. 24-AUG-26 LP 60501.-END-SDR 2DYA202608230021Battery Pack · dischargedDURING LINE INSP. OPS CHECK R3 AND R4 EMERGENCY EXTERIOR LIGHTS INOP. R & R R3 BULB AND BATTERY PACK W/OH UNIT. IAW AMM 33-51-07. OPS CHECKED GOOD.SDR 2DYA202604230010Bulb · inoperativeDURING CO. RAMP CHECK OVERHEAD EMERGENCY LIGHTS LEFT SIDE SEATS $ & 6 INOP. 22-APR-25 LP 60441-1SDR 2DYA202603150010Bulb · inoperativeDURING CO. RAMP CHECK OVERHEAD EMERGENCY LIGHTS LEFT SIDE SEATS $ & 6 INOP. 22-APR-25 LP 60441-1SDR 2DYA202604230015Bulb · inoperativeDURING CO. RAMP CHECK MULTIPLE EMERGENCY CEILING LIGHTS INOP L AND R AISLE FROM DOOR 3L-3R.22-APR-26 LP6044-2.SDR 2DYA202604230014Battery Pack · inoperativeDURING RAMP CHECK FOUND EMERGENCY EXIT SIGN ABOVE LAV DOOR 4R INOP. 22-APR-26 LP 60441-2SDR 2DYA202604230012Battery Pack · inoperativeDURING CO. RAMP CHECK EMERGENCY EXIT SIGN ABOVE LAV 4R INOP. 22-APR-26 LP 6044-3.SDR 2DYA202604230011Battery Pack · inoperativeDURING CO. RAMP CHECK EXTERIOR EMERGENCY LIGHTS AT DOORS 3 & 4 DID NIT TEST. 22-APR-26 LP 60440-2SDR 2DYA202603150009Battery Pack · inoperativeDURING CO. RAMP CHECK FOUND LIGHTED EXIT SIGN AT L2 DOOR INOP. 22-APR-26 LP 60440-3.SDR 2DYA202603150008Battery Pack · inoperativeDURING CO. RAMP CHECK FOUND LIGHTED EXIT SIGN AT L2 DOOR INOP. 22-APR-26 LP 60440-3.SDR 2DYA202603050003Battery Pack · dischargedDURING A1 CHECK EMERGENCY LIGHTS AT L2 DOOR FAILED TO TEST. R&R WITH NEW BATTERY PACK P/N AD692013-1A S/N 69431 IAW B767 AMM 33-51-07. OPS CHECKED GOOD. 3-MAR-26 LP 43008.-END-SDR 2DYA202512090014Battery · no testFWD CLOSET MEGAPHONE FAILED TO TEST. R&R BATTERIES. OPS CHECKED GOOD.SDR 2DYA202508130008Battery Pack · dischargedEMERGENCY LIGHTS INOP INTERIOR LIGHTS AT 1L AND 1R. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK AT DOORS 1L AND 1R IAW B767 AMM 33-51-07-022-001 AND AMM 33-51-07-422-012. OPS CHECK GOOD..13-OCT-25 LP 60220SDR 2DYA2025081300010Skin · puncturedLEFT HORIZONTAL STAB PUNCTURED AT TWO LOCATIONS REF LP 57598. INTERIM REPAIR INSTALLED TO THE LH H-STAB INSPAR LOWER SKIN AT RIB 10 BETWEEN STRINGERS 3 AND 7 PER ASI ENGINEERING REPAIR ORDER NO. 5510D4013. INSTALL A PERMANENT REPAIR DURING THE NEXT C-CHECK INSDR 2DYA2025F00239Skin · puncturedL/ HORIZONTAL STAB PUNCTURED AT TWO LOCATIONS. INTERIM REPAIR INSTALLED TO THE LH H-STAB INSPAR LOWER SKIN AT RIB 10 BETWEEN STRINGERS 3 AND 7 PER ASI ENGINEERING REPAIR ORDER NO. 5510D4013. INSTALL A PERMANENT REPAIR DURING THE NEXT C-CHECK INSPECTION. 9-OCTSDR 2DYA2025081300009Battery Pack · dischargedINTERIOR LIGHTS AT 4L AND 4R DOORS. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK AT DOORS 4L AND 4R IAW AMM 33-51-07-022-001 AND AMM 33-51-07-422-012. OPS CHECK GOOD. 13-OCT-25 LP 60220SDR 2DYA202508130007Battery Pack · dischargedEMERGENCY EXTERIOR LIGHTS FAILED TO TEST AT DOORS L3 &L4. R&R EMERGENCY LIGHT BATTERY PACK AT LOCATION M738. 13-OCT-25 LP 60221.SDR 2DYA2025082900006Access Panel · inflt separationUPON LANDING PANEL 'S 411GR AND 411DL DEPARTED THE ENG. DAMAGE TO FOLLOWING COMPONENTS, LT WING NR 2 FLAP (15"X6" LOWER AND 3X2) UPPER, OUTER SECTION OF EXHAUST NOZZLE, PANE'S 411PL AND 411QR, BLOCKER DOORSS 1,.2, 3, 4 & 8. 5.SDR 2025F00215Access Panel · detachedUPON LANDING PANEL #'S 411GR & 411DL DEPARTED THE ENGINE. DAMAGE TO FOLLOWING COMPONENTS: L/WING #2 FLAP (15"X6" LOWER & 3X2) UPPER, OUTER SECTION OF EXHAUST NOZZLE, PANEL #'S 411PL & 411QR, BLOCKER DOORS #'S 1.2.3.4 & 8.SDR 2DYA202508130003Battery Pack · no testM1209 E. BATTERY FAILED CAPACITY TEST. REF. WO # 7010-0009-2025 NR 0157SDR 2DYA202508130002Battery · no testM736 AND M1210 E. BATTERY FAILED CAPACITY TEST .REF. WO# 7101-0009-2025 NR#'S 0158 0159.SDR 2025F00197Battery Pack · no testBATTERY ALL FAILED CAPACITY TEST.SDR 29EA202508250194Battery Pack · dischargedM1209,M736 & M1210 E. BATTERY ALL FAILED CAPACITY TEST. WO # 7010-0009-2025 NR'S # 0157/0158/0159SDR 2DYA202403150078Bulb · burned outEMERGENCY EXIT SIGNS BULBS INOP.SDR 2DYA202403150075Bulb · burned outEMERGENCY CENTRAL LIGHTS DID NOT ILLUMINATE DURING THE TEST.SDR 2DYA202403130070Skin · corrodedBLEND REPAIR TO LH INSPAR WING PANEL NO.1 LOWER SURFACE AT REAR OF SPAR AND WS 1055.0SDR 2024F00069Skin · corrodedBLEND REPAIR TO LH SPAR WING PANEL NO.1 LOWER SURFACE AT STINGER NO.7 AND WS 1089.0SDR 2DYA202403130068Skin · corrodedBLEND REPAIR LH WING LOWER SKIN AT WS 1040.0SDR 2DYA202403130067Skin · corrodedBLEND REPAIR TO RH INSPAR WING PANEL NO.1 LOWER SURFACE AT THE REAR OF SPAR AND WS 635.0SDR 2DYA2024F00066Skin · corrodedCORROSION ON TE SKIN AT STA. WS 839.00SDR 2DYA2024F00065Skin · corrodedRH HORIZONTAL STAB UPPER SKIN BLEND REPAIR AT RIB #7SDR 2DYA202403130064Skin · corrodedCORROSION ON RH HORIZONTAL STAB INSPAR UPPER SKIN AT THE REAR OF SPAR & HSS 127.465.SDR 2024F00063Skin · corrodedLH HORIZONTAL STAB. CORROSION AT INB SPAR UPPER SKIN AT RIB N16 BETWEEN STRINGER 1 AND REAR.SDR 2DYA2023F00239Lamp · burned outBULBS IN-OP IN SIDEWALL EXIT SIGN AT R/H OVER WING EXIT.SDR 2022F00456Warning Light · faultedWHEN L1 DOOR WAS CLOSED, DOOR WARNING LIGHT DID NOT GO OUT .SDR 2022F00445Proximity Sensor · faultedENTRY DOOR LIGHT L FWD ENTRY DOOR AND EICAS MESSAGE APPEAR AFTER DOOR IS CLOSED.SDR 2022FA0000336Fuse · blownCABIN EMERGENCY LIGHTS POWER SUPPLY (M730) FUSES. HAVE OPEN CIRCUITS AT STA 401.0SDR 2022F00285Battery Pack · depletedEMERGENCY BATTERY PACK DISCHARGES IN LESS THAN 15 MINUTES (M732) AT STA 1010RNSDR 2022F00284Stabilizer · dentedINTERIM REPAIR INSTALLED TO THE H-STAB RH LOWER SURFACE INSTALL PERMANENT REPAIR NEXT "C" CHECK. PERFORMED MAJOR REPAIR CAT "A" ON RH HORIZONTAL STAB LOWER PANEL AROUND STA AUXILIARY SPAR IAW SEMAN ED-0011 20220239 FAA FORM 8110-3 DATED JUNE 21-2022SDR 2DYA20211023000None · noneEMERGENCY SIGNS BY DOORS L4 AND R4 INOP. PERFORM OPERATIONAL CHECK IAM B676 AMM 33-51-00. OPS CHECK NORMAL AT THIS TIME.SDR 2DYA20201013000None · noneL/H ENGINE NO EPR INDICATION. MX USED PROCEEDURE IN FIM 77-12 FAULT TREE 8O6. PERFORMED WIRING CHECK OF AMM 77-12-02-404-007 DO OPS TEST TEST SATISFACTORY FOR A/C TO RETRUEN TO SERVICE. NO DEFECTS NOTED AT THE TIME.SDR 2DYA20210927000None · noneMX DISCOVERED THAT THE MID GALLEY COFFEE MAKER WAS INOP. MX MECHANIC CLEANED GROUND ELECTRICAL CONNECTORS IAW B767 AMM 20-41-00. COFFEE MAKER OPS CHECK NORMAL IAW B767 AMM 25-31-00.SDR 2DYA20200916000Hydraulic System · false indicationRIGHT HYDRAULIC SYSTEM INDICATES (RF) ON STATUS PAGE FLUID DROPPING IN QUANTITY (RIGHT HYD" EICAS MSG DISPLAYED. THE CORRETIVE ACTION WAS THE MECHANIC FIM 29-11 F/T 830 AND CHECKED A/C FOR LEAKS. NO LEAKS FOUND, TRANSFERED FLUID TO R/H SYSTEM AND CLEANED SHUTSDR 2DYA20200824000Module · leakingWHILE TAXING THE RT HYD SYSTEM DROPS 1% EVERY 9 MINUTES. AT 53% WHEN RETURNING TO THE FIELD. REMOVED AND RPLACE THE LEFT ANTI SKID MODULE PER AMM 33-42-02. OPS CHECK TEST OKAY. A/C RETURNED TO SERVICE.SDR 2DYA20210511002A/C Pack · odorACRID SMELL FROM AIR CONDITIONING WHEN ENGINES COME TO IDLE DURING DESCENT. PERFORMED GVI ON AIR CONDITIONING SYSTEM PER AMM 05-51-56 AND ENGINE RUN UP, NO ODOR NOTED. REF. B767 AMM 71-00-00 TEST# 3.SDR 2DYA20210511001Battery Pack · dischargedPASSENGERS COMPARTMENT & PASSAGEWAY, EXIT SIGN AND LH SIDE DOOR EMERGENCLY LIGHTS TURN OFF IN 10 SECONDS (L316, L314, L315, L317). CORRECTIVE ACTION: R/R PACK IAW AMM 33-51-07. OPS CHECK OK IAW AMM 33-51-07SDR 2DYA2021051100011Battery Pack · dischargedPASSENGERS COMPARTMENT & PASSAGEWAY, EXIT SIGN AND RH SIDE DOOR EMERGENCLY LIGHTS TURN OF IN 10 SECONDS (L1121, L777, L995, L321 AND L776). CORRECTIVE ACTION: R/R PACK IAW AMM 33-51-07. OPS CHECK OK IAW AMM 33-51-07SDR 2DYA20210222000Bulb · inoperativeDURING MAINTENANCE ROUTINE IT WAS FOUND THE L4 EMERGENCY EXTERIOR LIGHT IS INOP. BULB WAS REPLACED.SDR 2DYA20201218001Ground Wire · unsecureTROUBLESHOT IAW THE WIRE DIAGRAM MANUAL 33-51-01, FOUND WIRE GROUND LOOSE AT RIGHT MID. RE-SECURED AND CLEANED SOCKET ASSEMBLY AT RIGHT MID RIGHT AFT ASSEMBLY, RELAMPED. OPERATIONS CHECK NORMAL, PER STANDARD WIRE PRACTICE 20-10-13 AMM 33-51-02.