N715UW

Service difficulty reports · 306

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N715UW' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR USAASA03029Psu · inoperativePHL - THE EMERGENCY EXIT LIGHT ON THE AIRCRAFT RIGHT SIDE, MID CABIN, WAS INOPERATIVE DURING THE EMERGENCY LIGHTS TEST. MAINTENANCE REPLACED AN EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK. (M)Mar 26, 2003 · N715UW · Airbus A319112 · Emergency LightingSDR USAASA02111Girt Bar · out of positionMSP - FLT 807 - MSP-CLT - PRIOR TO PUSHBACK, THE LEFT ENTRY DOOR WOULD NOT SHOW CLOSED ON ECAM WITH THE SLIDE SHOWING ARMED. UPON INSPECTION, THE GIRT BAR WAS FOUND HANGING BELOW THE DOOR. MAINTENANCE REINSTALLED THE GIRT BAR. OK FOR SERVICE. (M)Dec 16, 2002 · N715UW · Airbus A319112 · Emergency EquipmentSDR USAASA02112Girt Bar · out of positionCLT - FLT 807 - EN ROUTE MSP-CLT, AFTER TAKEOFF, A LOUD AIR LEAK WAS FOUND TO BE COMING FROM THE FORWARD LEFT DOOR. THE FLIGHT CONTINUED TO CLT AND LANDED WITHOUT INCIDENT. MAINTENANCE REINSTALLED THE GIRT BAR. OPERATIONALLY CHECKED OK. (M)Dec 16, 2002 · N715UW · Airbus A319112 · Emergency EquipmentSDR USAASA02108Valve · stuckEN ROUTE, A BURNING ODOR WAS PRESENT IN THE AIRCRAFT CABIN DURING THE FLIGHT. MAINTENANCE REPLACED THE AFT TRIM VALVE. OPERATIONALLY CHECKED, OK.Dec 11, 2002 · N715UW · Airbus A319112 · Cabin Temperature Control SystemSDR USAASA02107Valve · stuckEN ROUTE, WHILE CLIMBING THROUGH 10,000 FEET, FLIGHT ATTENDANT REPORTED AN ODOR OF SMOKE IN THE CABIN. THE FLIGHT RETURNED AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE AFT TRIM VALVE. OPERATIONALLY CHECKED OK.Dec 11, 2002 · N715UW · Airbus A319112 · Cabin Temperature Control SystemSDR USAASA01038Power Supply · dischargedBOS - THE EMERGENCY LIGHTS FAILED THE TEST ON THE CABIN INTERCOMMUNICATION DATA SYSTEM. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 11WL. (M)Jul 22, 2001 · N715UW · Airbus A319112 · Emergency Lighting
Back to N715UW