N725UW
Service difficulty reports · 175
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N725UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N725UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011092000026Skin · saturated2S CHECK - AREA OF WATER INGRESS ON UPPER SURFACE OF RIGHT ELEVATOR APPROX 148 INCHES FROM INBOARD END. REPAIRED RIGHT ELEVATOR UPPER SURFACE IAW A319 SRM 55-21-11 PARA G, FIG 207.SDR USAA2011092000025Skin · saturated2S CHECK - AREA OF WATER INGRESS ON UPPER SURFACE OF RIGHT ELEVATOR APPROX 22 INCHES FROM INBOARD END IN 2 PLACES. REPAIRED RIGHT ELEVATOR UPPER SURFACE IAW A319 SRM 55-22-11 PARA G, FIG 207.SDR USAA2011092000024Skin · saturated2S CHECK - AREA OF WATER INGRESS ON UPPER SURFACE OF RIGHT ELEVATOR APPROX 89 INCHES FROM INBOARD END. REPAIRED RIGHT ELEVATOR UPPER SURFACE IAW A319 SRM 55-22-11 PARA G, FIG 207.SDR USAA2011092000023Skin · saturated2S CHECK - AREA OF WATER INGRESS ON UPPER SURFACE OF RIGHT ELEVATOR APPROX 39 INCHES FROM INBOARD END. REPAIRED RIGHT ELEVATOR UPPER SURFACE IAW A319 SRM 55-22-11 PARA G, FIG 207.SDR USAA2011092000022Skin · saturated2S CHECK - AREA OF WATER INGRESS ON UPPER SURFACE OF RIGHT ELEVATOR APPROX 107 INCHES FROM INBOARD END. REPAIRED RIGHT ELEVATOR UPPER SURFACE IAW A319 SRM 55-21-11 PARA G, FIG 207.SDR USAA2011092600011Flap · delaminated2S CHECK - DELAMINATION ON RIGHT OUTBOARD AFT FLAP TRAILING EDGE APPROX 66 INCHES FROM INBOARD END & 4 INCHES FROM TRAILING EDGE. REPLACED RIGHT OUTBOARD AFT FLAP ASSEMBLY IAW EA 130684, A319 AMM 27-54-62.SDR USAA2011092000033Floor Panel · cracked2S CHECK - CRACK IN CABIN FLOOR PANEL BETWEEN FR36 TO FR42 & BETWEEN Y254 TO Y765. REPLACED CABIN FLOOR PANEL BETWEEN FR36 TO FR42 & BETWEEN Y254 TO Y765 IAW A319 AMM 53-32-12-400-002.SDR USAA2009033090716Lens · missingFLT 1181 - DTW-CLT - EMERGENCY LIGHTS - EMERGENCY EXIT LIGHT COVER MISSING ON SEAT 10C. BULBS ARE OPERATING NORMAL. REMOVED AND REPLACED LENS ON EMERGENCY LIGHT ON ROW 10C.SDR USAA920081516Chiller · faultyFLT 1177-LGA-CLT- BURNING ODOR - FORWARD CHILLER HAS A BURNING ODOR. TURNED CHILLER OFF AND ODOR DISSIPATED. MAINTENANCE REMOVED AND REPLACED FORWARD CHILLER. OPERATIONAL CHECK WAS GOOD. (S)SDR USAA920081386Decoder · failedPIT-CII-EEL- EMERGENCY LIGHT BIT TEST FAILS. REPLACED FORWARD DECODER/ENCODER UNIT-B. (A)SDR SA08033Epsu · failedTPA - FWD EMERGENCY LIGHT POWER UNIT FAILED. MAINTENANCE REPLACED FWD POWER SUPPLY, OPS OK.SDR SB08033Epsu · failedTPA - FWD EMERGENCY LIGHT POWER UNIT FAILED. MAINTENANCE REPLACED FWD POWER SUPPLY, OPS OK.SDR SA06048Bulb · burned outTPA - ROW 19 A/B/C SEAT MOUNTED EMERGENCY LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PLACED THE AIRCRAFT ON MEL. MAINTENANCE RELAMPED THE EMERGENCY LIGHT ON ROW 19 A/B/C. OPERATIONALLY CHECKS OK.SDR SA05127Fan · overheatedSJU FLT 1037, EN ROUTE PHL TO SJU. DURING THE OPERATION OF THE AIRCRAFT, A BURNING ODOR WAS DETECTED IN THE FLIGHT DECK. AN ECAM WARNING OF BLOWER FAULT WAS GENERATED AROUND THE SAME TIME. THE CREW FOLLOWED PROCEDURES FOR THE WARNING AND COMPLETED THE FLIGSDR USAA051112Sill · corrodedFOUND CORROSION Y 1500 AND FRAME 6. DEFECTIVE PART REPLACED WITH IDENTICAL PART NUMBER, DEFECT SIZE: 2 SQ IN.SDR SA05100Sensor · faultyPIT FLT 268 ON CLIMB OUT FROM PIT, AT FL160, CREW REPORTED THE NR 1 ENGINE AGENT ONE DISCHARGE LIGHT ILLUMINATED. FLIGHT ATTENDANT REPORTED FLAMES OUT THE REAR OF THE ENGINE WHILE A DEADHEAD PILOT REPORTED EXCESSIVE VIBRATION. CREW DECLARED AN EMERGENCY ANSDR USAA051072Floorbeam · corrodedCORROSION FLOORBEAM FR 66 -Y1500. INSTALLED DOUBLER PER SRM 53-41-14 REPAIR 6. DEFECT SIZE: 1.5 X .75 INCH.SDR USA2004F00000Odor · detectedENROUTE PIT-IAH. DURING FLIGHT, NOTICED OILY ODOR AT MID-CABIN. FLIGHT CONTINUED AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE OPERATED THE AIR CONDITIONING PACKS WITH THE APU. NO ODOR DETECTED. CHECKED APU AREA. NO OIL DRAINAGE NOTED. FOUND AIRCRAFTSDR USAASA04001Epsu · will not testDCA - ESPU FAILED SELF-TEST. MAINTENANCE REPLACED THE LEFT (11LWA) EMREGENCY LIGHT EPSU. (M)SDR USAASA03084Slide · defectiveCLT - THE RIGHT SIDE AFT ENTRY DOOR SLIDE COVER WOULD NOT REMAIN INSTALLED. MAINTENANCE REPLACED THE RIGHT SIDE AFT ENTRY DOOR ESCAPE SLIDE, THEN INSTALLED COVER. OK FOR SERVICE. (M)SDR USAASA03069Slide · malfunctionedNO EMERGENCY LIGHTS DID NOT ILLUMINATE ON THE AFT RIGHT SLIDE WHEN THE SLIDE WAS DEPLOYED FOR AN OPERATIONAL CHECK. MAINTENANCE REPLACED THE ESCAPE SLIDE. OPERATIONALLY CHECKED EMERGENCY LIGHTS SYSTEM. OK FOR SERVICE. (M)SDR USAASA02079Battery Pack · dischargedCLT - THE EMERGENCY LIGHT TEST INDICATED A 'L FWD LT' FAULT. MAINTENANCE REPLACED THE BATTERY PACK FOR THE LEFT FORWARD LIGHT. OPERATIONALLY CHECKED AND TESTED OK. (M)SDR USAASA00024Fan · overheatedSTL - FLT 163 - EN ROUTE PHL-PHX - WHILE IN CRUISE AT FL350, A VIBRATION WAS FELT IN THE COCKPIT AREA, FOLLOWED LATER BY AN ELECTRICAL ODOR. WHEN THE ODOR BECAME PRESENT, THE CREW PUT ON THEIR OXYGEN MASKS AND THE FLIGHT DIVERTED TO STL, AND LANDED WITHOUT INSDR USAASA00020Light · inoperativeSFO - FOUND ROW 8 SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT ASSEMBLY. OPS CHECKS NORMAL. (M)SDR USAASA00018Battery · dischargedPIT - FOUND THE EMERGENCY LIGHTS FAILED TEST. MAINTENANCE REPLACED THE BATTERY PACK ON AFT EMERGENCY POWER SUPPLY UNIT, OPS CHECKED OK. (X)
Back to N725UW