N732YX
Service difficulty reports · 57
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N732YX' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N732YX' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A2020112500813Skin · damagedLEFT HORIZONTAL STABILIZER LOWER SKIN DAMAGE BETWEEN RIBS 11 AND 12 AND FROM FRONT SPAR TO STGR 02L. REPAIRED LEFT HORIZONTAL STABILIZER LOWER SKIN BETWEEN RIBS 11 AND 12 AND FROM FRONT SPAR TO STGR 02L AND 11L TO RIB 12L, IAW ETD 2020-170-030610.SDR R61A2020112500812Spar · damagedMAJOR REPAIR: LEFT HORIZONTAL STABILIZER FRONT SPAR DAMAGE BETWEEN RIBS 11 AND 12. REPAIRED LT HORIZONTAL STABILIZER SPAR I FROM RIB 11L TO RIB 14L, IAW ETD2020-170-030610.SDR R61A202001310146Spar · cracked***WHILE A/C WAS OUT OF SERVICE FOR A HEAVY CHECK*** RH WINGLET CRACKED AT FWD SPAR. REMOVED AND REPLACED RH WINGTIP IAW 170EO-57-30-0001_1. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A202001310145Skin · cracked***WHILE A/C WAS OUT OF SERVICE FOR A HEAVY CHECK*** LH WINGLET CRACKED AT FWD SPAR. REMOVED AND REPLACED LH WINGTIP IAW 170EO-57-30-0000_1. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A2019060630585Battery · inoperativeEMERGENCY LIGHT BATTERY FAULT ON EICAS. R&R FWD RH EMERGENCY LIGHT BATTERY IAW 33-50-01.SDR R61A201701230062Sensor · failedCREW RECEIVED AN L2 DOOR OPEN INDICATION. AN EMERGENCY WAS NOT DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED AFT PAX DOOR WARNING SENSOR IAW AMM AND OPS CHECKED GOOD.SDR R61A201701220060Proximity Sensor · out of adjustCREW RECEIVED AN L2 DOOR OPEN INDICATION. AN EMERGENCY WAS NOT DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE ADJUSTED L2 DOOR SENSOR IAW AMM AND OPS CHECKED GOOD.
Back to N732YX