N732YX

Service difficulty reports · 57

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N732YX' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR R61A2020112500813Skin · damagedLEFT HORIZONTAL STABILIZER LOWER SKIN DAMAGE BETWEEN RIBS 11 AND 12 AND FROM FRONT SPAR TO STGR 02L. REPAIRED LEFT HORIZONTAL STABILIZER LOWER SKIN BETWEEN RIBS 11 AND 12 AND FROM FRONT SPAR TO STGR 02L AND 11L TO RIB 12L, IAW ETD 2020-170-030610.Oct 28, 2020 · N732YX · Emb ERJ170200LR · Fuselage Main, BulkheadSDR R61A2020112500812Spar · damagedMAJOR REPAIR: LEFT HORIZONTAL STABILIZER FRONT SPAR DAMAGE BETWEEN RIBS 11 AND 12. REPAIRED LT HORIZONTAL STABILIZER SPAR I FROM RIB 11L TO RIB 14L, IAW ETD2020-170-030610.Oct 28, 2020 · N732YX · Emb ERJ170200LR · Horizontal Stabilizer, Spar/RibSDR R61A202001310146Spar · cracked***WHILE A/C WAS OUT OF SERVICE FOR A HEAVY CHECK*** RH WINGLET CRACKED AT FWD SPAR. REMOVED AND REPLACED RH WINGTIP IAW 170EO-57-30-0001_1. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.Jan 28, 2020 · N732YX · Emb ERJ170200LR · Wing SparSDR R61A202001310145Skin · cracked***WHILE A/C WAS OUT OF SERVICE FOR A HEAVY CHECK*** LH WINGLET CRACKED AT FWD SPAR. REMOVED AND REPLACED LH WINGTIP IAW 170EO-57-30-0000_1. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.Jan 28, 2020 · N732YX · Emb ERJ170200LR · Wing, Plate/SkinSDR R61A2019060630585Battery · inoperativeEMERGENCY LIGHT BATTERY FAULT ON EICAS. R&R FWD RH EMERGENCY LIGHT BATTERY IAW 33-50-01.Jun 3, 2019 · N732YX · Emb ERJ170200LR · Emergency LightingSDR R61A201701230062Sensor · failedCREW RECEIVED AN L2 DOOR OPEN INDICATION. AN EMERGENCY WAS NOT DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED AFT PAX DOOR WARNING SENSOR IAW AMM AND OPS CHECKED GOOD.Jan 23, 2017 · N732YX · Emb ERJ170200LR · Door Warning SystemSDR R61A201701220060Proximity Sensor · out of adjustCREW RECEIVED AN L2 DOOR OPEN INDICATION. AN EMERGENCY WAS NOT DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE ADJUSTED L2 DOOR SENSOR IAW AMM AND OPS CHECKED GOOD.Jan 22, 2017 · N732YX · Emb ERJ170200LR · Door Warning System
Back to N732YX