N74007
Service difficulty reports · 101
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N74007' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N74007' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2019100501697Oven · failedOVEN 203 SMOKED AND FAILED. ELECTRIC SMELL R+R STEAMER OVEN #203 IN FWD GALLEY AS PER AMM 25-35-03,RAN STEAMER OVEN FOR 20 MINS ALL OPS CHK OK.SDR CALA2019051300767Battery Pack · dischargedON CHK FND L1 DOOR EPAS GREEN TEST INDICATOR LIGHT CONTINUOUSLY BLINK WHEN SAFETY SWITCH IN "ARM" POSITION. L1 DOOR EPAS 9 VOLT BACK-UP BATTERIES REPLACED AND TEST CARRIED OUT "SATIS" IAW AMM 52-11-20 DEFECT UPDATE: CHK FND L1 DR EPAS GREEN TEST INDICATOR LIGHSDR CALA2018062211499Charger · inoperativeL3 DOOR EMERGENCY LIGHT POWER SUPPLY M33400 CHARGER WAS INOPERATIVE. REPLACED THE CHARGER , TESTED NORMAL IAW AMM 33-51-06SDR CALA2018062211498Battery Pack · dischargedL3 DOOR EMERGENCY LIGHT POWER SUPPLY BATTERY HAD LOW CAPACITY. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062201514Charger · inoperativeL3 DOOR EMERGENCY LIGHT POWER SUPPLY M33400 CHARGER WAS INOPERATIVE. THE POWER SUPPLY CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062211493Battery Pack · dischargedR2 DOOR EMERGENCY LIGHT BATTERY PACK M33097 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062211492Battery Pack · dischargedL2 DOOR EMERGENCY LIGHT BATTERY PACK M33096 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK M33096 WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062211491Battery · dischargedR4 DOOR EMERGENCY LIGHT BATTERY PACK M33408 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK M33408 REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062211490Battery · dischargedR2 DOOR EMERGENCY LIGHT BATTERY PACK M33098 WAS FOUND TO HAVE LOW CAPACITY. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062101479Battery · dischargedDR L2 OVERDOOR EMER LT POWER SUPPLY M33099 BATTERY PACK LOW CAPACITY. DR L2 OVERDOOR EMER LIGHT POWER SUPPLY BATTERY M33099 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2018062101478Battery Pack · dischargedOHAR AREA EMER LT FOUND DIM. OHAR AREA EMER LIGHT POWER SUPPLY BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2018062101477Battery · dischargedDR L3 OVERDOOR EMER LT POWER SUPPLY M33400 BATTERY PACK LOW CAPACITY. DR L3 OVERDOOR EMER LIGHT POWER SUPPLY BATTERY M33400 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2018060601424Fitting · crackedLEFT ELEVATOR OTBD ACTUATOR FITTING, ONE CRACK WAS FOUND, APPROXIMATELY 7/16 INCH IN LENGTH.SDR CALA2018020200433Light · inoperativeMED 2L EXTERIOR EMERGENCY LIGHT INOP RELAMPED, OPS CHECKS GOOD. REF AMM 31-51-04-960-801SDR CALA2018011200141Connector · meltedELECTRICAL BURNING ODOR IN LAVATORY G. FOUND MELTED FLOURECENT TUBE CONNECTOR. REMOVED AND REPLACED THE BALLAST AND LIGHT SOCKET IAW AMM 33-26-00. OPS CHECKED NORMAL.SDR CALA2017081802769Light · inoperativeON CHK FOUND EMER LT AT R1 INOP. EMER LT AT R1 RELAMP AND TEST OKAY IAW AMM 33-51-00.SDR CALA2017051201388Warning System · false activationDOOR WING SLIDE R EICAS ADVISORY. THE RIGHT SLIDE COMPARTMENT DOOR IS EITHER OPEN, CLOSED BUT NOT LOCKED ON THE GROUND, OR THE STATE OF THE PROXIMITY SENSOR CANNOT BE DETERMINED CYCLED DOOR 3R SEVERAL TIMES, DOOR INDICATION GOOD AT CSCP, NO FAULTS NOTED AT THISDR CALA2017040700914Warning System · false activationEMERG LIGHT EICAS MESSAGE ON RECALL. EMERG LIGHTS OPERATIONAL TEST GOOD PER AMM 33-51-00. EICAS NOT ILLUMINATED ON RECALL.SDR CALA2016020100078Charger · faultyL2 DOOR EXTERIOR EMER SLIDE LIGHT & L2 DOOR AFT INTERIOR EMER EXIT IDENTIFIER SIGN INOPERATIVE. ALSO LT CEILING EMER LIGHT INOPERATIVE BETWEEN L2 DOOR & L3 DOOR. IAW AMM 33-51-06 EMER LIGHT POWER SUPPLY CHARGER & BATTERY PACK AT L2 DOOR M33099 REPLACED & TESSDR CALA2015063000541Charger · inoperativeLEFT DOOR 3, M33405 EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. LEFT DOOR 3 EMER LIGHT BATTERY CHARGER. REPLACED & OPERATION TESTED NORMAL IAW AMM 33-51-06.SDR CALA2015063000540Charger · inoperativeLEFT DOOR 1, M33424 EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. LT DOOR 1 EMER LIGHT BATTERY CHARGER REPLACED & OPERATION TESTED NORMAL IAW AMM 33-51-06.SDR CALA2015063000539Charger · inoperativeLEFT DOOR 4, 33407 EMER LIGHT BATTERY CHARGER FOUND INOPERATIVE. LT DOOR 4 LIGHT BATTERY CHARGER M33407 REPLACED & OPERATION TESTED NORMAL IAW AMM 33-51-06.SDR CALA2015051500397Power Supply · inoperativeON CHECK FOUND RT 4 DOOR EMER EXIT SIGN LIGHT INOPERATIVE. L33541 INOPERATIVE POWER SUPPLY. M33408 REPLACED & CHECKED SATISFACTORY AMM 33-51-06.SDR CALA2015051500396Power Supply · failedRIGHT DOOR, 4 EMER SIGN LIGHT INOPERATIVE IAW WDM 33-51-34. POWER SUPPLY M33408 FAILED. REPLACED POWER SUPPLY. CHECKED SATISFACTORY AMM 33-51-06.SDR CALA2015040600254Slide · depletedDOOR 3R SLIDE DEPLOYED. PERFORMED SLIDE RESTORATION IAW AMM 25-66-00-810-801. INSTALLED 3R SLIDE IAW AMM 25-65-01-400-801 & FORM 46-0035. ROTABLE PARTS CHANGE WAS INDICATED. TT 1709614, SN OFF 00431 SLIDE, B777-200 OFF 25-2560-9-0008 0431 ON 25-2560-9-0008SDR CALA2015011600047Wire · brokenL1 DOOR EPAS BATTERY PACK FAILED OPERATIONAL CHECK. REF JOB CARD JE25-5210-1-9801. IAW WDM 52-11-13 FOUND WIRE W3070-2004 R2 AT PIN 11 CONNECTOR DM52105 BROKEN. REPINNED IAW SWPM 20-30-00. OPERATIONS CHECKED NORMAL. ROTABLE PARTS CHANGE WAS INDICATED, TT SDR CALA2015010600006Battery Pack · dischargedL3 DOOR CTR EMER LIGHT BATTERY PACK FOUND INOPERATIVE. L3 DOOR CTR EMER LIGHT BATTERY PACK REPLACED & TESTED NORMAL IAW AMM 33-51-06.SDR CALA2013083000594Battery · failedSMOKE ODOR IN FLIGHT DECK CABIN. SMOKE ODOR IN FLIGHT DECK CABIN CONDITIONAL INSPECTION CHECKED OUT IAW AMM TASK 05-51-58-800-801C3 - SATISFACTORYSDR CALA2013050300262Controller · inoperativeAFTER T/O "ENG BLEED LT OFF EICAS" LT BLEED VALVE FUEL DUMP AND RETURNED TO EWR. REFER TO L/P 7351111 PARTS CHANGE AND OPS TEST.SDR CALA2013021400104Battery Pack · no testL1 DOOR EMERGENCY LIGHT BATTERIES M33093, M33424, FOUND CAPACITY CHECK FAILED. BATTERIES REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400103Battery Pack · no testR1 DOOR EMERGENCY LIGHT BATTERY, M33094, CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400102Battery Pack · no testR4 DOOR EMERGENCY LIGHT BATTERY, M33409, CAPACITY CHECK FAILED. BATTERY, REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400101Battery Pack · no testL3 DOOR EMERGENCY LIGHT BATTERY, M33405 CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400100Battery Pack · no testL2 DOOR EMERGENCY LIGHT BATTERY, M33096, CAPACITY CHECK FAILED. BATTERY, REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400098Battery Pack · failedR3 DOOR EMERGENCY LIGHT BATTERY M33401 CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400097Battery Pack · no testR2 DOOR EMERGENCY LIGHT BATTERIES M33097, M33098 FOUND CAPACITY CHECK FAILED. BATTERIES REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400096Battery Pack · no testL4 DOOR EMERGENCY LIGHT BATTERY, M33407 FOUND CAPACITY CHECK FAILED. BATTERY PACK REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2012110200727Skin · dentedFOUND SMALL SCRATCH AND DENT ON FWD LWR EDGE OF BULK CARGO DOOR SKIN DAMAGED. FOUND TO BE WITHIN LIMITS IAW SRM 52-30-01.SDR CALA2012030700164Cap · damagedEMERGENCY LIGHT 3E MISSING. REMOVED AND REPLACED BROKE CAP AND ASSEMBLY. UNIT CHECKS GOOD. A/C OK TO CONTINUE.SDR CALA2012022400126Battery · dischargedFLASHLIGHT AT DOOR 4L INOP. REPLACED FLASHLIGHT BATTERY & STRAP AT 4L, CHECKS GOOD.SDR CALA2012022400125Battery · dischargedFLASHLIGHT AT DOOR 4R INOP. REPLACED FLASHLIGHT BATTERY & STRAP AT DOOR 4R. CHECKS GOOD.SDR CALA2011081900546Battery · dischargedDOOR 4L JUMPSEAT INBOARD HAND HELD EMERGENCY FLASHLIGHT LED DOES NOT TEST. REMOVED AND REPLACED FLASHLIGHT BATTERY AMM 25-64-01-710-801.SDR CALA2011022800110Unknown · malfunctionedFLT 7000 WITH 56KN DIRECT CROSS WIND FROM RT, A/C HAD CONTINUOUS SMOOTH UNCOMMANDED RUDDER INPUTS. YAW DAMPER INDICATIONS WERE 1/2 LEFT TO 1/3 RIGHT DISPLACEMENT. THIS CONDITION LASTED FOR AS LONG AS WIND WAS REG L/P 8751429 FOR CORRECTIVE ACTION.. LOG PG 87SDR CALA0700150Seat Track · corrodedINSPECTION FOUND SEAT TRACK CORRODED AT STA 1510-1586, RBL 108. REPAIRED IAW SRM 53-00-52, REPAIR 4, FIGURE 202.SDR CALA0600210Apu · failedA FLIGHT ATTENDANT AT ROW 34 REPORTED AN ELECTRICAL AND SMOKY ODOR SHORTLY AFTER LEVEL OFF AT FL 360 EN ROUTE TO EWR. NO SMOKE WAS VISIBLE. THE ODOR WAS ONLY MOMENTARY. THE FLIGHT WAS CONTINUED TO EWR WHERE IT LANDED WITHOUT FURTHER PROBLEM. MAINTENANCE FOSDR CALA0300132Seat Track · corrodedINSPECTION FOUND SEAT TRACK CORRODED AT BS 1485-1520, RBL 74. THE SEAT TRACK WAS REPAIRED IAW SRM 53-00-52, REPAIR 3, FIGURE 202.SDR CALA0300129Door Frame · crackedINSPECTION FOUND A 1" CRACK IN FORWARD CARGO DOOR FRAME UPPER EDGE APPROXIMATELY 21 INCHES FROM FORWARD EDGE. IN ADDITION, THE AREA WAS SCRATCHED AND GOUGED. REPAIRED IAW ECRA 5230-01718.SDR CALA0300128Skin · dentedINSPECTION FOUND L/H FUSELAGE SKIN DENTED AT BS 676 BETWEEN S27L AND S28L. REPAIRED IAW SRM 53-00-01, REPAIR 7, FIGURE 202. A DIP WAS INITIATED TO REINSPECT THE REPAIR AT 30,000 FLIGHT CYCLES WITH REPEAT INSPECTION AT 16,000 FLIGHT CYCLES PER SRM 53-00-01, REPSDR CALA0300123Skin · nickedINSPECTION FOUND FUSELAGE SKIN NICKED AT BS 626, S3L. A FLUSH REPAIR WAS INSTALLED IAW SRM 53-00-01, REPAIR 2, FIGURE 202.SDR CALA0300122Window Frame · gougedINSPECTION FOUND A GOUGE IN L/H PASSENGER WINDOW CUTOUT FRAME AT AFT EDGE, STA 710. REPAIRED IAW ECRA 5330-03227.
Back to N74007