N744SK
Service difficulty reports · 209
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N744SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N744SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200719165Floorbeam · crackedFS 280 CROSS BEAM IS CRACKED AT RBL9 AND LBL9, FOUND AT C-CHECK. COMPLIED WITH REPAIR OF BEAM PER REO 670-53-11-047.SDR SWIA200718072Oil System · low pressureRECEIVED RIGHT ENGINE LOW OIL PRESSURE EMERGENCY MESSAGE. SHUT ENGINE DOWN. REPLACED RIGHT ENGINE ASSEMBLY IAW M/M 71-00-00 AND RII 72-400-1000. OPERATIONAL CHECK GOOD, P/N: CF-348C1, S/N OFF: GE-E965640.SDR SWIA200718030Lamp · burned outFOUND OVERHEAD CEILING EMERGENCY LIGHT AT ROW 7 IS INOP. RELAMPED EMERGENCY FLOOD LIGHT AT ROW 7 IAW CRJ 700 AMM 33-51-00. OPERATIONAL CHECKS GOOD.SDR SWIA200617023Window · crackedLEFT SIDE WINDOW SHATTERED AT FL300. RETURNED COS. REPLACED LEFT SIDE WINDOW IAW AMM 56-11-01 AND ST 56-220-1000. PRESSURE CHECK GOOD, PN NP139322-11, SN 04213H2407.SDR SWIA200616796Controller · malfunctionedLOST PRESSURIZATION AT FL370-380. CABIN ALT WENT TO 13000 FT AND CABIN ALT WARNING MESSAGE ILLUMINATED. EMERGENCY DESCENT TO 10,000 FEET. REPLACED SAFETY VALVE NR 1 IAW CRJ AMM 21-32-03. OPERATIONAL CHECKS GOOD, PN: GG670-98005-1, SN ON: 00804 SN OFF: 006SDR SWIA200616417Battery Pack · intermittentEMERGENCY LTS ON STATUS MSG WOULD NOT CLEAR. REPLACED EMERGENCY BATTERY PACK AND CHARGER (NR3) IAW MM 33-51-17. OPERATIONAL CHECK GOOD.SDR SWIA200616386Circuit Board · malfunctionedEMERGENCY LIGHTS ILLUMINATED DURING FLIGHT. REPLACED PRINTED CIRCUIT BOARD PCB5 IN JB11 IAW CRJ 700 MM ATA CHPT 24-06-11 AND REPLACED NR 3 AND NR 4 EMERGENCY BATTERY'S IAW CRJ 700 MM ATA CHPT 33-51-17. OPERATIONAL CHECK GOOD NR 3 P/N: 2013-1A, S/N OFF: 7219SDR SWIA200515276Transmitter · malfunctionedELEVATOR SPLIT CAUTION MESSAGE DISPLAYED. RETURN TO FIELD PER QRH. REMOVED AND REPLACED ELEVATOR POSITION TRANSMITTER PER MM 27-34-10. OPERATIONAL CHECK GOOD.SDR SWIA200514733Wire · damagedEMERGENCY LIGHT EXIT SIGN ON AFT OF BULKHEAD SEPARATING 1ST CLASS & COACH (RT SIDE) IS INOPERATIVE. REPAIRED WIRES ON EMERGENCY LGIHT EXIT SIGN. OPERATIONAL CHECK GOOD.
Back to N744SK