duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N748FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N748FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201111174961Seat Track · gougedSEAT TRACK GOUGED BETWEEN FR 48 AND 49. BLENDED GOUGE, FOUND TO BE OUT OF LIMITS IAW 51-73-10. REMOVED DAMAGED SECTION AND INSTALLED SEAT TRACK REPAIR IAW SRM 51-10-16.SDR FDEA201111154929Skin · damagedLT ELEVATOR TOP SKIN APPROX 14 FT FROM ELEVATOR TIP AND 9.5 IN. FROM T/E HAS A PUNCTURED IN COMPOSITES 1.0 IN. X .50 IN REPAIRED 1 EA PUNCTURED ON ELEVATOR TIP OTBD T/E USING CARBON FIBER AND RESIN IAW SRM 55-21-12, PARA 5A. RESTORED SURFACE PROTECTION IAW SDR FDEA201111104855Stringer · corrodedAFT CARGO COMPARTMENT STRINGER 56R CORRODED LOCATED BETWEEN FRAME 57.2 THRU FRAME 57.3. FOUND OUT OF LIMITS IAW SRM 51-73-11. REPAIRED STRINGER IAW SRM 53-10-14, FIG 201E, SHEET 1, PAGE 215/216.SDR FDEA201111064772Skin · dentedFWD CARGO DOOR EXTERIOR SKIN DENTED APPROX L=0.7X W"=0.5" BETWEEN FR 21A AND FR 22 AT BEAM 3. FWD CARGO DOOR EXTERIOR SKIN DENTED, SKIN REPAIRED IAW SRM 52-30-00, FIG 203. COMPLIED WITH EA6-5230-156053.SDR FDEA201111034743Skin · dentedLT WING INBD FLAP INBD L/E RIB HAS A 1" X 1" X .102" DENT REPAIRED LT WING INBD FLAP INBD L/E DENT IAW WITH SRM 57-50 00, PG 231-234, FIG 208.SDR FDEA201111014697Floor Panel · brokenFLOOR PANEL 241LK BROKE IN 2 PIECES. FABRICATED REPLACEMENT FLOOR PANEL 241LK IAW DWG SRZ25-005, REV J.SDR FDEA201110304689Skin · chafedR-1 DOOR FWD UPPER CORNER INNER SKIN HAS WEAR MARK. BLENDED OUT. DAMAGE FOUND TO BE OUT OF LIMIT IAW SRM 52-11-00, TABLE 101. ORIGINAL MATERIAL THICKNESS .039, MATERIAL LOSS ,006. REMOVED SEAL RETAINER FOR ACCESS OF REPAIR IAW SRM 51-40-21. CUT-OUT DAMAGE IASDR FDEA201110304691Angle · chafedLT WING LOWER INBD SURFACE PICKUP ANGLE AFT OF REAR SPAR RIB 1 HAS 15" AREA OF CHAFING AT HYD SERVICING PANEL. R & R ANGLE (STAMPING) IAW SRM 51-40-21, PARA 5.SDR FDEA201110304690Depressor · gougedAFT CARGO DOOR BULB SEAL DEPRESSOR FOR DOOR CUTOUT HAS NICKS AND GOUGES OVER ENTIRE SURFACE ALONG FWD AND AFT EDGES. R & R 6EA SEALING SECTIONS ON AFT CARGO DOOR CUTOUT.SDR FDEA201110284685Floor Support · corrodedFLOOR SUPPORT CORRODED BETWEEN FR 14A TO FR 16, BUTTLINE -Y1959, AT BOTTOM SIDE AROUND FASTENER HOLES. TEE CORRODED WITH 100 PERCENT LOSS, R & R TEE IAW SRM 51-72-10.SDR FDEA201110284684Seat Track · damagedSEAT TRACK R-5 HAS GOUGED SCALLOPS AT 2 EA PLACES BETWEEN FR63R AND FR64R. SMOOTHED AND BLENDED 2 EA GOUGES IN SEAT TRACK BETWEEN FR 63R AND FR 64R IAW SRM 51-73-10, PARA 5, CHECKED LIMITS, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16, FIG 101. R & R SEAT TSDR FDEA201110274660Floor Panel · crackedFLOOR PANEL 262 ZF IS BROKEN IN HALF AND CRACKS FABRICATED REPLACEMENT FLOOR PANEL 262 ZF IAW DWG SRZ 25-005, REV J, MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110264653Seat Track · gougedCABIN SEAT TRACK 4R, FRAME 74 9 INCHS, 2 EACH GOUGES ON SCALLOP TOP ON EACH SIDE 1/4" BY 1/4" WITH METAL RAISED UP .100" SMOOTHED AND BLENDED CABIN SEAT TRACK 4R, FR. 74 9" IAW A300-600 SRM 53-17-16 P101 PARA 3, FOUND TO BE OUT OF LIMITS ORG. .655" MATERIASDR FDEA201110254638Seat Track · gougedSEAT TRACK NR 4 LT HAS 2 GOUGES UP CROWN BETWEEN FR 60-61. SMOOTHED & BLENDED GOUGED AREAS IAW SRM 53-17-16, PG 101, PARA 103. ORIGINAL MATERIAL .655 HOLE DIA NOW 1.0. REMOVED .345" FOUND TO BE OUT OF LIMITS REMOVED SEAT TRACK IAW SRM 53-10-16, ALODINED, PRSDR FDEA201110254637Floorbeam · corrodedFLOORBEAM IN CARGO BAY AT FRAME 67 AND 6 INCHES LT OF CTR AREA, CORRODED 2 SQ IN. REMOVED CORROSION ON FLOORBEAM IAW SRM 51-74-10, AREA IS OUT OF LIMITS IAW SRM 53-10-15, FIG 100 SH2. 100 PERCENT MAT LOSS, 2"X 2 X .125. R & R WITH NEW FLOORBEAM IAW SRM 51-7SDR FDEA201110244629Stiffener · gougedNR 1 PYLON OTBD VERTICAL STIFFENER ON FWD FACE OF RIB 20 HAS GOUGE L.3 X D.1. R & R NR1 PYLON OTBD VERTICAL STIFFENER ON FWD FACE OF RIB 20 WITH NEW PART IAW SRM 51-41-21, PG 22 AND PARA 13.SDR FDEA201110214617Seat Track · corrodedMAIN DECK CARGO TRACK NR 2 LT CORRODED AT FR 18, 12" UP SIDE. REMOVED CORROSION IAW SRM 51-74-10. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16 PG 103. REMOVED AND REPLACED SEAT TRACK IAW SRM 51-72-10. REPROTECTED FASTENERS IAW SRM 51-75-10. APPLIED CIC TO SEASDR FDEA201110204602Seat Track · corrodedMAIN DECK CARGO NR 3 LEFT SEAT TRACK HAS SPOTS OF CORROSION FROM FR 15B TO 19. FOUND TO BE OUT LIMITS IAW SRM 53-10-16. REMOVED & REPLACED SEAT TRACK IAW SRM 51-72-10 PARA 5A REPROTECTED FASTNERS IAW SRM 51-75-10 APPLIED CIC IAW AMM 51-75-10-8.SDR FDEA201110204594Floor Panel · delaminatedFWD CARGO FLOOR PANEL 132QF DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005 REV J.SDR FDEA201110194583Floorboard · damagedFLOORBOARD 151CF HAS 4 DISCREPANCY 1.AND2. GOUGES AT END CORNERS OF BOARD.3. CORNER OF BOARD BY SCREW HOLE IS BROKEN 4. SIDE OF FLOORBOARD HAS FILLING COMING OUT FABRICATED REPLACEMENT PANEL 151CF IAW DWG SRZ25-005 REVJ IDENTIFIED REPLACEMENT FLOORBOARD IASDR FDEA201110194582Floorboard · damagedFLOORBOARD 151GF HAS 5 DISCREPANCY 1. CORNER HAS FILLING COMING OUT. FASTENER HOLE ON BOTTOM SIDE HAS FILLING BREAKING OFF. CORNER IS BROKEN, HAS 2" CUT INBD. GOUGE ON END OF BOARD. FABRICATED REPLACEMENT FLOORBOARD 151GF IAW DWG SRZ25-005 REV J, IDENTIFISDR FDEA201110194581Floorboard · crackedFWD AREA FLOORBOARD 221PF CRACKED LT SIDE 22 IN. APPROX ALSO 2 EA LONG SCRATCHES UP SKIN REF AMM 53-10-15-06 FABRICATED REPLACEMENT FLOORBOARD 221PF IAW DWG SRZ25-005 REV J, MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110184559Seat Track · corrodedSEAT TRACK NR 2 RT CORRODED AT FR 16. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16. R & R SEAT TRACK IAW SRM 51-72-10.SDR FDEA201110184575Carriage · damagedRT WING NR 2 FLAP TRACK CARRIAGE AFT OTBD YOKE ROLLER DAMAGED. R & R NR 2 FLAP TRACK CARRIAGE AFT OTBD YOKE ROLLER IAW AMM 20-21-12.SDR FDEA201110184574Seat Track · failedSEAT TRACK NR 5 LT Y1959 BETWEEN FRAMES 59 TO 60 MISREPAIRED. R & R COMPLETE SEAT TRACK ASSY FROM FR 58 TO 62 IAW SRM 51-72-10, PG 1 TO 3 AND DWG A53274786.SDR FDEA201110184567Floorboard · crackedFLOORBOARD 252DH HAS A CRACK ALL ACROSS BOTTOM SIDE 12" LONG AMM 53-10-16-06 FABRICATED REPLACEMENT PANEL 252DH IAW DWG SRZ25-005 REV J, MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110184566Floorboard · damagedFWD MACC FLOORBOARD 231KG BROKEN AT LOWER SURFACE APPROX W=4"X2=4" REF AMM 53-10-16-06 FABBED FLOORBOARD 231KG IAW DWG SRZ25-005, REV J, MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110184558Floor Panel · delaminatedMLG W/W FLOOR PANEL 147EF WET AND DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL 147EF MLG WHEEL WELL IAW DWG SRZ 25-005, REV J.SDR FDEA201110174543Stringer · corrodedFWD CARGO BAY STRINGER 46R CORRODED AT FR 38.2 PLUS 10. REPAIRED STRINGER IAW SRM 53-10-14 FIG 201 PGS 205/206.SDR FDEA201110154525Floorboard · delaminatedFLOORBOARD 147CF OIL SOAKED. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ-25-005, REV J, MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110154524Floorboard · crackedFLOORBOARD 151FF HAS SEVERAL CRACKS AND DELAMINATED. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ-25-005, REV J. MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110154519Floorboard · delaminatedFLOORBOARD 162EF METAL SKIN DISBONDED AND 1 EA INSERT PULLED THRU FABRICATED NEW FLOORBOARD IAW DWG SRZ-25-005 AND SRZ-25-011.SDR FDEA201110144493Floor Panel · crackedFLOOR PANEL 131RF HAS 8 SQ INCHES OF DELAMINATION AND CRACKED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201110144492Floor Panel · damagedFLOOR PANEL 143DF IS OIL SOAKED 25 PERCENT OF PANEL. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201110144487Floor Panel · crackedFLOOR PANEL 131JG HAS 3EA DELAMINATED CORNERS AND 1EA CRACK 1" LONG AND 4 SQ IN OF DELAMINATION ON UPPER SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201110144486Floor Panel · crackedFLOOR PANEL 151HF HAS AN 18" CRACK. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 22-005, REV J.SDR FDEA201110144485Floor Panel · delaminatedFLOOR PANEL 162DF CRUSHED AND DELAMINATED ON UPPER SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201110134464Floorbeam · corrodedAFT CARGO COMPARTMENT FLOORBEAM TEE CORRODED UNDERNEATH 1R ROLLER TRACK AT FR 62R. REPLACED TEE IAW SRM 51-40-24.SDR FDEA201110134479Floorboard · delaminatedFLOORBOARD 151BF HAS 12" OF EDGE DELAMINATION. FABRICATED REPLACEMENT FLOORBOARD 151BF IAW DWG SRZ 25-005 REV J MAJOR REPAIR IAW GMM 6-2-100SDR FDEA201110134483Floorboard · damagedFLOORBOARD 143CF IS OIL SOAKED AROUND EDGES, FABRICATED FLOORBOARD IAW DWG SRZ25-005, REV J. MAJOR REPAIR IAW GMM6-2-100.SDR FDEA201110134482Floorboard · delaminatedFLOORBOARD 151LF HAS DELAMINATED CORNER AND EDGE OF PANEL 6" FABRICATED FLOORBOARD IAW DWG SRZ 25-005 MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110134481Floorboard · delaminatedFLOORBOARD 132HG HAS 2 FT OF DELAMATION ON EDGE. FARICATED REPLACEMENT FLOORBOARD IAW SRZ-25-005, REV J, MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110134473Floor Panel · crackedFLOOR PANEL 131ZF SEVERAL CRACKS AND DAMAGE ON PANEL FLOOR BOARD 131 ZF. FABRICATED NEW FLOOR PANEL IAW DWG SR25-005, REV J. MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110134472Floor Panel · crackedFLOOR PANEL 131HG HAS EDGE DAMAGE AND SEVERAL CRACKS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ25-005, REV J. MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110134471Floor Panel · crackedFLOOR PANEL 132ZF CRACKED IN HALF, FABRICATED REPLACEMENT FLOOR PANEL 132 ZF IAW DWG SRZ25-005, REV J. MAJOR REPAIR IAW GMM6-2-100.SDR FDEA201110134470Floor Panel · delaminatedFLOOR PANEL 132RF HAS DELAMINATED EDGE 8FT. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ-25-005, REV J IDENTIFIED. MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110134469Floor Panel · crackedFLOOR PANEL 132JG HAS 2 CRACKS 8" AND 10" FABRICATED FLOOR PANEL IAW DWG SRZ 25-005, REV J. MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110134468Floor Panel · crackedFLOOR PANEL 251YG HAS 2 EA CRACKS AT CLS CUT OUT 4" AND 1". FABRICATED REPLACEMENT FLOOR PANEL IAW SR25-005 REV J. MAJOR REPAIR IAW GMM 6-2-100.SDR FDEA201110124434Frame · gougedFWD CARGO COMPARTMENT CUT-OUT AFT SIDE FR 26 GOUGED AT EDGE BETWEEN STR 36 R- 37R, BLENDED AND SMOOTHED GOUGE AT FWD CARGO COMPARTMENT CUT-OUT BETWEEN STR 36R AND 37R AT FR 26R IAW SRM 51-73-10, MECHANICALLY MEASURE MAT LOSS ON EDGE .020" FOUND TO BE WITHIN SDR FDEA201107222911Brake · overtempT/O MEM HOT BRAKES AFTER LANDING CLT BRAKE TEMPS EXCEEDED 600 (MAX TEMP 630). ACFT STOPPED OUTSIDE GATE AND CHECK BY FIRE CREW. TIRE NR 7 & 8 HOTEST WITH 1 FLAT. R & R NR7 AND NR8 TIRE IAW MM 12-37-32-0. R & R NR8 BRAKE IAW MM 32-42-27-4. BLEED NR7 AND N