N751UW
Service difficulty reports · 250
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N751UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N751UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2012122700003Hinge Fitting · excess play2S CHECK - EXCESSIVE PLAY ON RUDDER HINGE BEARING NR 1 AT VERTICAL STABILIZER STA 78 RIB 2. REPLACED RUDDER HINGE ARM FITTING NR 1 AT VERTICAL STABILIZER STA 78 RIB 2 IAW A319 AMM 55-36-41 & SRM 51-42-11.SDR USAA2012121900023Floor Panel · delaminated2C CHECK - DELAMINATION ON FLOOR PANEL 151VG BETWEEN FR53 TO FR55A & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL 151VG IAW A319 SRM 53-02-00 FIG 209 & MCGILL IRM 9701 REV G.SDR USAA2012121800009Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 132DG BETWEEN FR28 TO FR34 & BETWEEN Y1042.1 TO -Y765. REPLACED FLOOR PANEL 132DG IAW A319 SRM 53-02-00 FIG 209 & IRM 9701 REV G.SDR USAA2012121800008Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 151ZG BETWEEN FR55 TO FR59 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL 151ZG IAW A319 SRM 53-02-00 FIG 209 & IRM 9701 REV G.SDR USAA2012121200009Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261HG BETWEEN FR64 TO FR66 & BETWEEN Y512 TO Y1732. REPLACED FLOOR PANEL 261HG IAW A319 SRM SUPPLEMENTAL INF. 53-02-00-201 FIG 209 & MCGILL IRM 9701 REV G.SDR USAA2012122800005Fitting · corroded2S CHECK - CORROSION ON UPPER SURFACE OF R1 DOOR SILL FITTING BETWEEN FR16 TO FR20, S23R. REPLACED R1 DOOR SILL FITTING BETWEEN FR16 TO FR20, S23R IAW A319 SRM 51-72-11 & AIRBUS DRAWING D53110339.SDR USAA2012122400014Fitting · corroded2S CHECK - CORROSION ON L1 DOOR SILL FITTING BETWEEN FR16 TO FR20, S23L. REPLACED L1 DOOR SILL FITTING BETWEEN FR16 TO FR20, S23L IAW A319 SRM 51-72-11 & AIRBUS DRAWING D53110339.SDR USAA2012101800016Wire · brokenEMERGENCY LIGHT INOPERATIVE AT SEAT ROW 4ABC. REPAIRED BROKEN WIRE ON CONTACTOR PIN OF SIDEWALL CONNECTOR IAW ELECTRICAL STANDARD PRACTICES MANUAL 20-53-55.SDR USAA2012072600009Lens · missingSEAT MOUNTED EMERGENCY EXIT LIGHT LENS MISSING AT SEAT 8D. INSTALLED NEW LENS AT 8D IAW AIRBUS MAINTENANCE MANUAL 33-51-19.SDR USAA2012040200021Flashlight · inoperativeON PREFLIGHT, FORWARD FLIGHT ATTENDANT JUMPSEAT EMERGENCY FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED FORWARD FLASHLIGHT AND BATTERY. OPERATIONAL CHECK GOOD.SDR USAA2012032800002Floor Panel · corrodedC11 CHECK - DELAMINATION ON FLOOR PANEL 262HG BETWEEN FR64 TO FR66 & -Y768 TO -Y1598, Z-500. REPLACED FLOOR PANEL 262HG IAW MCGILL IRM 9701.SDR USAA2012032600018Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR65, S23R, Z-500, -Y754. REPLACED FLOORBEAM BETWEEN FR64 TO FR65, S23R, Z-500, -Y754 IAW A319 SRM 51-72-11 & AIRBUS DRAWING 18D53472815.SDR USAA2012032600016Floor Panel · damagedC11 CHECK - SURFACE DAMAGE ON FLOOR PANEL 232DF BETWEEN FR20 TO FR24, Z-500, -Y510. REPLACED FLOOR PANEL 232DF IAW A319 SRM 51-72-11.SDR USAA2012032300014Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR20, Z-500, -Y765. REPLACED FLOORBEAM AT FR20, Z-500, -Y765 IAW A319 SRM 53-11-15. UPON FURTHER REVIEW BY US AIRWAYS ENGINEERING, IT HAS BEEN DETERMINED THAT THIS IS NOT CLASSIFIED AS A CPCP LEVEL 2 SDR USAA2012032300012Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR12 TO FR24, Z-500, -Y254. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, Z-500, -Y254 IAW A319 SRM 51-72-11, 51-42-11 & 51-21-11.SDR USAA2012032300009Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR12 TO FR24, Z-500, Y1292. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, Z-500, Y1292 IAW A319 SRM 51-42-11.SDR USAA2012032300007Floorbeam · corrodedC11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR BEAM AT FR16, Z-500, -Y81. REPLACED FLOOR BEAM AT FR16, Z-500, -Y81 IAW A319 SRM 53-11-14.SDR USAA2012032300006Floorbeam · corrodedC11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR12 TO FR16, Z-500, -Y81. REPLACED FLOORBEAM BETWEEN FR12 TO FR16, Z-500, -Y81 IAW A319 SRM 51-42-11 & 53-11-14.SDR USAA2012032600011Tab · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON TAB AT FR16, Z-500, -Y1379.5. REPLACED TAB AT FR16, Z-500, -Y1379.5 IAW A319 SRM 51-72-11, 53-11-14, 51-43-00 & 51-42-11.SDR USAA2012032300017Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR16, Z-500, Y765. REPLACED FLOORBEAM AT FR16, Z-500, Y765 IAW A319 SRM 51-72-11.SDR USAA2012033000006Sill · corrodedC1 CHECK - CORROSION ON L2 SILL PLATE AT FR68, S23L, Z-500, Y1292. REPAIRED L2 SILL IAW SRM 51-42-11, 51-72-11 & EA 202078.SDR USAA2012032300005Sill · corrodedC11 CHECK - LEVEL 2 GALVANIC CORROSION ON R2 DOOR SILL PLATE BETWEEN FR66 TO FR68, Z-500, -Y1162.5. REPAIRED R2 DOOR SILL PLATE BETWEEN FR66 TO FR68, Z-500, -Y1162.5 IAW A319 SRM 53-41-14. UPON FURTHER REVIEW, ENGINERING DOWN GRADED LEVEL 2 CORROSION TO LEVESDR USAA2012032700003Shear Tie · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON SHEAR TIE BETWEEN FR69 TO FR70, Z-500, -Y1162.5. REPLACED SHEAR TIE BETWEEN FR69 TO FR70, Z-500, -Y1162.5 IAW A319 SRM 53-41-14 FIG 2 & TYPICAL REPAIR TR320-2528-10-0011C.SDR USAA2012032600017Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66, Z-500, -Y1292. REPLACED FLOORBEAM BETWEEN FR64 TO FR66, Z-500, -Y1292 IAW A319 SRM 51-72-11.SDR USAA2012032600015Floorbeam · corrodedC11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69, Z-500, -Y1162.5. REPLACED FLOORBEAM BETWEEN FR68 TO FR69, Z-500, -Y1162.5 IAW A319 SRM 51-72-11.SDR USAA2012032600014Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, Z-500 & BETWEEN -Y1292 TO -Y1162.5. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, Z-500 & BETWEEN -Y1292 TO -Y1162.5 IAW A319 SRM 51-72-11.SDR USAA2012032600013Beam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON Z-BEAM BETWEEN FR68 TO FR69, Z-500, Y1162.5. REPLACED Z-BEAM BETWEEN FR68 TO FR69, Z-500, Y1162.5 IAW A319 SRM 51-72-11.SDR USAA2012032600012Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR69, Z-500, -Y1162.5. REPLACED FLOORBEAM AT FR69, Z-500, -Y1162.5 IAW A319 SRM 51-72-11.SDR USAA2012032600010Shear Plate · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, Z-500, Y1589. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, Z-500, Y1589 IAW A319 SRM 51-72-11 & SRM 51-42-11.SDR USAA2012032600009Beam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON Z-BEAM BETWEEN FR64 TO FR66, Z-500, Y1292. REPLACED Z-BEAM BETWEEN FR64 TO FR66, Z-500, Y1292 IAW A319 SRM 51-72-11 & AIRBUS DRAWING 53472831.SDR USAA2012032600008Beam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON Z-BEAM BETWEEN FR66 TO FR68, Z-500 & BETWEEN Y1162.5 TO Y1292. REPLACED Z-BEAM BETWEEN FR66 TO FR68, Z-500 & BETWEEN Y1162.5 TO Y1292 IAW A319 SRM 51-72-11 & AIRBUS DRAWING 53472831.SDR USAA2012032600007Beam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON Z-BEAM BETWEEN FR68 TO FR69, Z-500, Y1162.5. REPLACED Z-BEAM BETWEEN FR68 TO FR69, Z-500, Y1162.5 IAW A319 SRM 51-72-11 & AIRBUS DRAWING 53472831.SDR USAA2012032300021Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR24, Z-500, -Y189. REPLACED FLOORBEAM AT FR24, Z-500, -Y189 IAW A319 SRM 51-72-11.SDR USAA2012032300019Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, Z-500, -Y300. REPLACED FLOORBEAM AT FR66, Z-500, -Y300 IAW A319 SRM 51-42-00.SDR USAA2012032300018Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR70, Z-500, Y464.8. REPLACED FLOORBEAM BETWEEN FR66 TO FR70, Z-500, Y464.8 IAW A319 SRM 51-42-11 & TYPICAL REPAIR TR320-2528-10-0011C.SDR USAA2012032300016Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, Z-500, Y765. REPLACED FLOORBEAM AT FR66, Z-500, Y765 IAW A319 SRM 51-72-11.SDR USAA2012032300015Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR64, Z-500, Y765. REPLACED FLOORBEAM AT FR64, Z-500, Y765 IAW A319 SRM 51-72-11.SDR USAA2012032300013Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR65.5 TO FR68, Z-500, -Y765. REPLACED FLOORBEAM BETWEEN FR65.5 TO FR68, Z-500, -Y765 IAW A319 SRM 51-72-11.SDR USAA2012032300011Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR12 TO FR23, Z-500, Y254. REPLACED FLOORBEAM BETWEEN FR12 TO FR23, Z-500, Y254 IAW A319 SRM 51-72-11.SDR USAA2012032300010Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR12 TO FR24, Z-500, Y1292. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, Z-500, Y1292 IAW A319 SRM 51-42-11 & 51-75-11.SDR USAA2012032300008Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR12 TO FR24, Z-500, Y1292. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, Z-500, Y1292 IAW A319 SRM 51-42-11 & 51-72-11.SDR USAA2010072691487Wire · looseFLT 1897 - CLT-ATL - EMERGENCY LIGHTS - FIRST CLASS EMERGENCY LIGHT SEAT 3 LEFT INOPERATIVE. FOUND LOOSE WIRE. SECURED AS REQUIRED FOR FIRST CLASS EMERGENCY LIGHT 3 LEFT. OPERATIONAL CHECK WAS GOOD.SDR USAA2009111293091Cylinder · low pressureFLT 2044 - DCA-BOS - EMERGENCY EQUIPMENT - L1 DOOR EMERGENCY BOTTLE NEEDS SERVICING. SERVICED L1 DOOR BOTTLE PER AMM 52-10-00-614.SDR USAA2009040190777Slide · unserviceablePIT - C11 - EES - FOUND L-2 DOOR SLIDE WITH BROKEN SAFETY ON LATCH & BALLS RELEASED FROM BAR. REPLACED L-2 DOOR SLIDE IAW US AIRWAYS JOB CARD 26C84252002.SDR USAA2009012890200Control Valve · inoperativeFLT 2125 - BOS-LGA - SMOKE - SMOKE SMELL REPORTED BY FLIGHT ATTENDANTS. REMOVED AND REPLACED RECIRCULATION FILTERS AND LEFT PACK FLOW CONTROL VALVE. SMOKE SMELL NO LONGER NOTED.SDR USAA060658Floor Support · corrodedFOUND SEVERAL AREAS AT FLOOR SUPPORT Y 503.2, FWD OF FS 14-16. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-72-11; CORROSION TASK JA-220-53500, LEVEL 1, DEFECT SIZE: 3 SQ IN.SDR USAA060662Floorbeam · corrodedFOUND 2 SPOTS CORROSION, FLOORBEAM Y1292 FRAME 65-70. REPLACED CORRODED SEGMENT OF BEAM PER DWG D53472780; CORROSION TASK JA-260-53500; LEVEL 1 DEFECT SIZE: 3/4"DIA AND 1" DIA.SDR USAASA04008Power Supply · inoperativeMAINTENANCE FOUND THE MID RIGHT EMERGENCY POWER SUPPLY UNIT INOPERATIVE. MAINTENANCE REPLACED MID RIGHT EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK. (M)SDR USAASA03086Release Cable · incorrectBOS - THE AFT RIGHT EMERGENCY ESCAPE SLIDE WAS FOUND TO HAVE AN INCORRECT RELEASE CABLE INSTALLED DURING INSPECTION. MAINTENANCE REPLACED THE SLIDE ASSEMBLY. OK FOR SERVICE. (M)SDR USAASA02016Transceiver · malfunctionedPVD - FLT 6422 - EN ROUTE DCA-BOS, DURING CRUISE, THE FLIGHT CREW HEARD STATIC SOUNDS COMING FROM THE VHF RADIOS. AFTER SWITCHING BACK TO VHF 1, THE CREW BEGAN TO SMELL SMOKE. THE FLIGHT CREW DONNED SMOKE MASKS. THE FLIGHT DIVERTED TO PVD, AND LANDED WITHOU
Back to N751UW