duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N753EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N753EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202503270019Skin · dentedFOUND VERTICAL DENT ON AFT PART OF R/H FUSELAGE BELOW R/H ENGINE ASSY. DAMAGE LOCATION FOUND TO BE APPROXIMATELY 0.5" INCHES AFT OF THE AFT RIVET LINE OF FRAME 1051.3. DENT SPANS VERTICALLY APPROXIMATELY 6 INCHES AND INTERSECTS STGR 14R AT THE DENT MID-POINT. SDR SWIA20241024Roller · failed inspLH ROLLER ON SLATS 3-2 FWD 1B FAILED INSPECTION (C-CHECK RO 12/24/2024) (FILED CLOSED)OK, TO INSTALL. PA. 911290REMOVED AND REPLACED LH ROLLER ON SLAT 3-2 FWD IB IAW CRJ 700 AMM 27-81-44.SDR SWIA202412261024Roller · failed inspLH ROLLER ON SLATS 3-2 FWD 1B FAILED INSPECTION (C-CHECK RO 12/24/2024) (FILED OPEN)OK, TO INSTALL. PA. 911290REMOVED AND REPLACED LH ROLLER ON SLAT 3-2 FWD IB IAW CRJ 700 AMM 27-81-44.SDR SWIA202412301023Roller · out of limitsRH SLAT TRACK ROLLER 1-2 AFT OUTBD FLAT SPOT OUT OF LIMITS (C-CHECK RO 12/24/2024) (FILED CLOSED) OK TO INSTALL PA911290 REMOVED AND REPLACED RH SLAT TRACK ROLLER 1-2 AFT OUTBD IAW AMM 27-81-44.SDR SWIA202412261023Slat Track · out of limitsRH SLAT TRACK ROLLER 1-2 AFT OUTBD FLAT SPOT OUT OF LIMITS (C-CHECK RO 12/24/2024) (FILED OPEN) OK TO INSTALL PA911290 REMOVED AND REPLACED RH SLAT TRACK ROLLER 1-2 AFT OUTBD IAW AMM 27-81-44.SDR SWIA202501071014Floorbeam · crackedRBL 12 COCKPIT FLOORBEAM CRACKED, OTBD SIDE, AT 280 BEAM. (C-CHECK RO 12/24/2024) (FILED CLOSED)PERFORMED REPAIR ON RBL 12 COCKPIT FLOOR BEAM OTBD SIDE AT 280 BEAM PER REO 670-53-11-896. REV. AMM 20-70-00.SDR SWIA202412261014Floorbeam · crackedRBL 12 COCKPIT FLOOR BEAM CRACKED, OTBD SIDE, AT 280 BEAM. (C-CHECK RO 12/24/2024) (FILED OPEN)PERFORMED REPAIR ON RBL 12 COCKPIT FLOOR BEAM OTBD SIDE AT 280 BEAM PER BOMBARDIER REO 670-53-11-896. REV. --. DATE: 2015-03-17. CRJ-700 AMM 20-70-00. NDT PERFORMEDSDR SWIA202053648Attach Bracket · crackedRT WING FLAP STUB FAIRING ATTACH BRACKET CRACKED. C-CHECK RO 10/22/2020. ORDERED AND RECEIVED A NEW RT STUB FAIRING ATTACH BRACKET. LOCATED AND DRILLED THE NEW BRACKET AND INSTALLED, REF CRJ 700 SRM.SDR SWIA202053647Support Bracket · corrodedCORROSION ON SUPPORT BRACKET P/N SH670-41524-1 AT STGR 21R BETWEEN FS 349 AND FS 364. C-CHECK RO 10/22/2020. REMOVED AND REPLACED THE SUPPORT BRACKET AT STGR 21R BETWEEN FS 349 AND FS 364 WITH NEW, REF CRJ 700 SRM AND BOMBARDIER DWG. SEE CONTINUATION CARD FSDR SWIA202053646Stringer · corrodedCORROSION ON STGR 21R BETWEEN FS 349-FS 364. C-CHECK RO 10/22/2020. REMOVED CORRODED STR 21R BETWEEN FS 349-364 AND REPLACED WITH NEW, REFERENCING DWG AND CRJ 700. LEAK TEST GOOD. COMPLIED WITH TASK CARD.SDR SWIA202053645Skin · dentedLT INBOARD FLAP DENTED JUST INBOARD OF WS 54.55, MARKED. C-CHECK RO 10/22/2020. REPAIRED LT INBOARD FLAP LOWER SKIN DAMAGE, IAW CRJ700 SRM.SDR SWIA202053644Floorbeam · corrodedMAIN CABIN CROSSBEAM AT FS 549.00 FOUND CORROSION UNDER FLOORBEAM AT LBL 9. C-CHECK RO 10/22/2020. BLENDED CORROSION, WITHIN LIMITS, REF REO. ALL STEPS ACCOMPLISHED. SEE CONTINUE CARD FOR DETAILS.SDR SWIA202053643Floorbeam · corrodedFS 280 RT CROSS BEAM HAS CORROSION. C-CHECK RO 10/22/2020. REMOVED CORRODED RT FS 280 CROSSBEAM AND REPLACED WITH NEW, REFERENCING DWG CRJ 700 SRM. COMPLIED WITH TASK CARD.SDR SWIA202053642Floorbeam · corrodedCORROSION AT APPROX FS 549 LBL 9 INBOARD ON FLOORBEAM. C-CHECK RO 10/22/2020. REPAIRED DAMAGED FLOORBEAM AT FS 549 LBL 9, REF CRJ700 SRM.SDR SWIA202053684Mount · corrodedCORROSION ON FLOOR MOUNT FITTING AT NUTPLATE LOCATION, BETWEEN RBL 9 TO RBL 27, FS 280.00 TO FS 295.00. C-CHECK RO 10/22/2020. CORROSION 100% THROUGH FLOOR MOUNTING FITTING, REMOVED CORRODED FITTING FROM INTERCOSTALS BETWEEN FS 280.00-FS 295.00 APPROXIMATELYSDR SWIA202053683Mount · corrodedCORROSION ON FLOOR MOUNT FITTING AT NUTPLATE LOCATION, BETWEEN LBL 27 TO LBL 36, FS 280.00 TO FS 295.00. C-CHECK RO 10/22/2020. CORROSION 100% THROUGH FLOOR MOUNTING FITTING, REMOVED CORRODED FITTING FROM INTERCOSTAL BETWEEN FS 280.00-FS 295.00 LBL 27-LBL 36SDR SWIA202053682Mount · corrodedCORROSION ON FLOOR MOUNT FITTING AT NUTPLATE LOCATION, BETWEEN LBL 9 TO LBL 27, FS 280.00 TO FS 295.00. C-CHECK RO 10/22/2020. CORROSION 100% THROUGH FLOOR MOUNTING FITTING, REMOVED CORRODED FITTING FROM INTERCOSTALS BETWEEN FS 280.00-FS 295.00 LBL 9-LBL 27,SDR SWIA202053681Mount · corrodedCORROSION ON FLOOR MOUNT FITTING AT NUTPLATE LOCATION, BETWEEN LBL 9 TO LBL 27 FS 310.00. C-CHECK RO 10/22/2020. CORROSION 100% THROUGH FLOOR MOUNTING FITTING, REMOVED CORRODED FITTING FROM FS 310.00 FLOOR SUPPORT POST, REF CRJ700 SRM. INSTALLED REPLACEMENTSDR SWIA202053641Stringer Splice · corrodedMAIN AVIONICS BAY STR 25R JOINT SPLICE AT FS 333.00 CORRODED. C-CHECK RO 10/22/2020. NO ALLOWABLE DAMAGE ON JOINT SPLICE. REMOVED AND INSTALLED NEW MAIN AVIONICS BAY STR 25R SPLICE AT FS 333.00, REF CRJ700 SRM AND DWG. NO LEAKS NOTED. COMPLIED WITH TASK CSDR SWIA202053640Frame · corrodedMAIN AVIONICS BAY FS 319.70 LOWER FRAME CORRODED BETWEEN STR 27 AND STR 26R. C-CHECK RO 10/22/2020. REMOVED CORRODED FS 319.70 FRAME BETWEEN STR 27 AND STR 26R AND REPLACED WITH NEW, REFERENCING CRJ 700 SRM. LEAK TEST GOOD. COMPLIED WITH SKYWEST TASK CARD.SDR SWIA202053680Doubler · corrodedTHE GALLEY NR 1 HAS A CORRODED DOUBLER BEHIND THE FLOOR MOUNT FITTING (FOOT) AT THE INBOARD/AFT CORNER. C-CHECK RO 10/22/2020. REMOVED THE GALLEY NR 1 CORRODED DOUBLER BEHIND THE FLOOR MOUNT FITTING (FOOT) AT THE INBOARD/AFT CORNER REFERENCING ZODIAC AEROSPASDR SWIA202053639Doubler · corrodedMAIN AVIONICS BAY TCAS ANTENNA DOUBLER CORRODED BETWEEN FS 295.00 AND FS 310.00. C-CHECK RO 10/22/2020. REMOVED CORRODED TCAS ANTENNA DOUBLER BETWEEN FS 295 TO FS 310 AND INSTALLED NEW, REF CRJ700 SRM AND DWG. NO LEAKS NOTED. COMPLIED WITH TASK CARD. COMPSDR SWIA202053679Channel · corrodedCORROSION ON RT FUSELAGE SIDE SEAT RAIL RETAINER (U CHANNEL) AT FS 581.00 TO FS 669.00. C-CHECK RO 10/22/2020. RECEIVED NEWLY FABRICATED RT FUSELAGE SIDE SEAT RAIL RETAINER (U CHANNEL) FROM FS 581.00 TO FS 669.00. DRILLED AND LOCATED, REF CRJ700 SRM. INSTASDR SWIA202053678Seat Track · corrodedCORROSION ON RT FUSELAGE SIDE SEAT RAIL AT FS 581.00 TO FS 669.00. C-CHECK RO 10/22/2020. REPLACED RT FUSELAGE SIDE SEAT RAIL AT FS 581-FS 669, REF CRJ700 AMM. SEE CONTINUE CARD.SDR SWIA202053677Seat Track · corrodedCORROSION ON RT FUSELAGE SIDE SEAT RAIL FROM FS 675.00 TO FS 713.00. C-CHECK RO 10/22/2020. REMOVED AND REPLACED WITH NEW THE RT SEAT TRACK AT FS 675-713 CRJ 700 AMM. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA202053676Channel · corrodedCORROSION ON LT FUSELAGE SIDE SEAT RAIL RETAINER (U CHANNEL) AT FS 752.00. C-CHECK RO 10/22/2020. REPLACED SEAT RAIL RETAINER WITH NEW (PN SH670-37557-3), REF CRJ700 AMM.SDR SWIA202053656Seat Track · corrodedCORROSION ON RT FUSELAGE SIDE SEAT RAIL FROM FS 785.00 TO FS 855.00. C-CHECK RO 10/22/2020. REPLACED RT FUSELAGE SIDE SEAT RAIL FROM FS 785.00 TO FS 855, REF CRJ700 AMM. SEE CONTINUE CARD FOR DETAILS.SDR SWIA202053675Bracket · corrodedCORROSION ON MACHINED BRACKET (FLOOR MOUNT PLATE) AT APPROXIMATELY FS 533 STGR 27. C-CHECK RO 10/22/2020. REMOVED CORROSION ON MACHINED BRACKET (FLOOR MOUNT PLATE) AT APPROXIMATELY FS 533 STGR 27, REF CRJ700 SRM. ORIGINAL MATERIAL THICKNESS IS 0.240,? REF DSDR SWIA202053638Stringer · corrodedCORROSION ON JOINT STRAP AT FS 333.00 STGR 21R. C-CHECK RO 10/22/2020. REMOVED CORROSION ON JOINT STRAP AT FS 333.00 STGR 21R, REF CRJ 700 SRM. ORIGINAL MATERIAL IS .063, MATERIAL REMOVED IS .027, MATERIAL REMAINING .036, OUT OF LIMITS. PERFORMED REPAIR, RSDR SWIA202053637Stringer · corrodedCORROSION FOUND ON STRINGER JOINT PIECE AT STGR 21R FS 333.00. C-CHECK RO 10/22/2020. REMOVED CORROSION ON STRINGER JOINT PIECE AT STGR 21R FS 333.00, REF CRJ 700 SRM. MATERIAL REMOVED IS .016, MATERIAL REMAINING .047, ORIGINAL MATERIAL IS .063, OUT OF LIMTSDR SWIA202053636Stringer · corrodedCORROSION ON STRINGER JOINT PIECE AT STGR 22R FS 333.00. C-CHECK RO 10/22/2020. REMOVED AND REPLACED STRINGER JOINT PIECE AT STGR 22R FS 333.00, REF CRJ700 SRM AND DW. NO LEAKS NOTED.SDR SWIA202053635Plate · corrodedCORROSION ON GROUND PLATES AT FS 319.00 STGR 21R. C-CHECK RO 10/22/2020. REMOVED AND REPLACED GROUND PLATES AT FS 319.00 STGR 21R, REF CRJ700 SRM AND DWG. COMPLETED FORM M-337. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA202053634Stringer Clip · corrodedCORROSION ON CLIP AT FS 310.00 STGR 20R. C-CHECK RO 10/22/2020. CLIP AT FS 310 STGR 20R CORRODED BEYOND LIMIT. REMOVED AND REPLACED, REF CRJ700 SRM AND DWG. COMPLIED WITH SKYWEST TASK CARD "STRUCTURAL MAJOR REPAIR" (RII).SDR SWIA202053633Skin · chafedAFT FUSELAGE EXTERNAL SKIN AT APPROXIMATEY FS 985.0 STGR 27 HAS 3 CHAFED AREAS, MARKED. C-CHECK RO 10/22/2020. BLENDED 3 CHAFED AREAS AFT FUSELAGE EXTERNAL SKIN AT APPROXIMATELY FS 985.0 STGR 27, REF REO. AREAS NR 1 & NR 2 ORIGINAL THICKNESS .118, NR 1 MATESDR SWIA202053632Fitting · corrodedPAX DOOR SILL FWD CLOSING FITTING HAS EVIDENCE OF CORROSION. C-CHECK RO 10/22/2020. PAX DOOR SILL FWD CLOSING FITTING HAS 100% MATERIAL LOSS DUE TO PITTING CORROSION. REMOVED AND INSTALLED NEW PAX DOOR SILL FWD CLOSING FITTING, REF CRJ 700. COMPLETED FORM SDR SWIA202053674Angle · corrodedCORROSION ON ANGLE BETWEEN FS 533.00 TO FS 517.00 STGR 27 TO 26L. C-CHECK RO 10/22/2020. REMOVED CORRODED ANGLE AT FS 333-FS 517 STR 27-26L AND REPLACED WITH NEW REFERENCING CRJ 700 SRM. OPERATIONAL, BONDING, AND LEAK TESTS GOOD.SDR SWIA202053673Frame · corrodedCORROSION ON FRAME FS 549.00 BETWEEN STGR 27 AT STGR 26L FWD SIDE. C-CHECK RO 10/22/2020. COMPLIED WITH MHI RJ REO-ALL STEPS ACCOMPLISHED.SDR SWIA202053672Bracket · corrodedCORROSION ON MACHINED BRACKET (FLOOR MOUNT PLATE) BETWEEN FS 549.00 TO FS 565.00, STGR 25R TO STGR 24R. C-CHECK RO 10/22/2020. REMOVED CORRODED MACHINED BRACKET BETWEEN FS 549-565 STR 25R-STR 24R AND REPLACED WITH NEW REFERENCING CRJ 700 SRM. LEAK TEST GOODSDR SWIA202053631Intercostal · corrodedCORROSION ON SGTR 21L ATTACHED INTERCOSTAL BETWEEN FS 349.00-FS 333.00. C-CHECK RO 10/22/2020. INSTALLED NEW INTERCOSTAL BETWEEN FS 333.00 AND FS 349.00 AT STR 21L, REF DWG AND CRJ700 SRM. RESTORED FINISH, REF CRJ700 SRM 51. APPLIED FILLET SEALENT, REF CRJSDR SWIA202053630Stringer Clip · corrodedCORROSION ON ATTACHING CLIP FOR STGR 19L FS 295.00. C-CHECK RO 10/22/2020. REMOVED CORRODED STR19L CLIP AT FS 295 AND REPLACED WITH NEW REFERENCING DWG AND CRJ 700 SRM. COMPLIED WITH SKYWEST TASK CARD. COMPLETED SKYWEST FORM M-337.SDR SWIA202053629Stringer · corrodedCORROSION ON STGR 21R BETWEEN FS 319.00-FS 333.00. C-CHECK RO 10/22/2020. REMOVED AND INSTALLED NEW STRINGER JOINT AND ANGLE AT STR 21R FS 333, REF CRJ 700 SRM AND DWG. REMOVED AND INSTALLED NEW STRINGER 21R BETWEEN FS 280-FS 333, REF REO. NO LEAKS NOTED.SDR SWIA202053628Stringer · corrodedCORROSION ON STGR 20R BETWEEN FS 295.00 TO FS 310.00. C-CHECK RO 10/22/2020. REPAIRED STR 20R BETWEEN FS 295-FS 310, REFERENCING CRJ 700 SRM DWG. LEAK TEST GOOD. COMPLIED WITH SKYWEST TASK CARD. COMPLETED SKYWEST FORM M-337.SDR SWIA202053627Stringer · corrodedCORROSION ON STGR 20R ATTACHED INTERCOSTAL BETWEEN FS 310.00 TO FS 349.00. C-CHECK RO 10/22/2020. REPLACED INTERCOSTAL BETWEEN FS 310-FS 349 ON STRINGER 20R, REF DRAWING AND CRJ700 SRM. SEE CONTINUE CARD FOR DETAILS.SDR SWIA202053626Stringer · corrodedCORROSION ON STGR 25 BETWEEN FS 319.00-FS 333.00, MARKED. C-CHECK RO 10/22/2020. REMOVED CORRODED STR 25R BETWEEN FS 280 AND FS 333 AND REPLACED WITH NEW REFERENCING DWG CRJ 700 SRM. LEAK TEST GOOD. COMPLIED WITH TASK CARD.SDR SWIA202053625Frame · corrodedCORROSION ON FRAME FS 310.00 BETWEEN STGR 26R-STGR 24L, AREAS MARKED ON FRONT AND AFT SIDES. C-CHECK RO 10/22/2020. REMOVED CORROSION ON FRAME FS 310.00 BETWEEN STGR 26R-STGR 24L, REF CRJ 700 SRM. EVALUATED AND FOUND TO BE OUT OF LIMITS. REMOVED CORRODED LSDR SWIA202053624Frame · corrodedCORROSION ON FRAME FS 295.00 BETWEEN STGR 26R-20L ON MULTIPLE AREAS, FRONT AND AFT SIDES, AREAS MARKED. C-CHECK RO 10/22/2020. REMOVED AND INSTALLED NEW FRAME SECTION REINFORCING ANGLE FROM STR 20L TO STR 25R, REF REO DWG, CRJ 700 SRM. NO LEAKS NOTED.SDR SWIA202053623Stringer · corrodedCORROSION ON STRG 27 AT APPROXIMATELY FS 283.00, MARKED. C-CHECK RO 10/22/2020. REMOVED CORROSION ON STR 27 AT FS 283.00, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW STR 27 FROM FS 280 TO FS 298, REF CRJ700 SRM AND DWG. NO LEAKS SDR SWIA202053622Slat Track · wornRT SLAT TRACK 3-3 HAS MULTIPLE WEAR MARKS ON ITS UPPER AND LOWER ROLLING SURFACES. C-CHECK RO 10/22/2020. REPAIRED RT SLAT TRACK 3-3, REFERENCING REO CRJ 700 SRM CRJ 700 AMM AND DWG. OPERATIONAL TEST GOOD. COMPLIED WITH SKYWEST TASK CARD. COMPLETED SKYWESSDR SWIA202053621Bracket · corrodedSERVICE DOOR SILL THRESHOLD BRACKETS AT APPROXIMATELY FS 321 AND FS 338 HAVE EVIDENCE OF CORROSION. C-CHECK RO 10/22/2020. INSTALLED 4 EA BRACKETS AND 4 EA ANGLES, REF CRJ 700 SRM AND DWG. COMPLIED WITH SKY CARD.SDR SWIA202053620Slat Track · wornLT WING SLAT TRACK 3-3 HAS MULTIPLE WEAR MARKS ON UPPER AND LOWER ROLLER CONTACT SURFACES. C-CHECK RO 10/22/2020. REPAIRED LT WING SLAT TRACK 3-3 WEAR MARKS, IAW REO CRJ700 SRM CRJ700 AMM. OPERATIONS CHECK GOOD AT THIS TIME.