N760SK
Service difficulty reports · 196
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N760SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N760SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201229808Light · inoperativeNR 3 OVERHEAD EMERGENCY LIGHT IS OUT. (SERVICE) RELAMPED EMERGENCY LIGHT.SDR SWIA201202129643Lamp · burned outFLT 5426, NR 3 OVERHEAD EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT.SDR SWIA201229611Light · inoperativeNR 5 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 6227) RELAMPED EMERGENCY LIGHT.SDR SWIA201229513Light · inoperativeNR 5 OVERHEAD EMERGENCY LIGHT IS OUT. (SERVICE) RELAMPED EMERGENCY LIGHT.SDR SWIA201229152Light · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 15 IS OUT. (FLT 5480) RELAMPED EMERGENCY LIGHT.SDR SWIA201128649Light · inoperativeNR 5 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 5607) RELAMPED EMERGENCY LIGHT.SDR SWIA201128309Light · inoperativeNR 3 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 6804) RELAMPED EMERGENCY LIGHT.SDR SWIA201128247Light · inoperativeNR 4 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 5449) RELAMPED EMERGENCY LIGHT.SDR SWIA201128188Light · inoperativeNR 4 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 5615) RELAMPED EMERGENCY LIGHT.SDR SWIA201128043Light · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 10 IS OUT. (FLT 2043) RELAMPED EMERGENCY LIGHT.SDR SWIA201127320Generator · failedBOTH NR 1 AND NR 2 GENERATORS KICKED OFF LINE DURING CLIMB. (FLT 6483) COULD NOT DUPLICATE NR 1 GENERATOR PROBLEM. REPLACED NR 2 GENERATOR.SDR SWIA201127034Light · inoperativeSECOND TO LAST CEILING EMERGENCY LIGHT IS OUT. (FLT 6369) RELAMPED EMERGENCY LIGHT.SDR SWIA201126545Light · inoperativeNR 5 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 1179) RELAMPED EMERGENCY LIGHT.SDR SWIA201126521Light · inoperativeNR 5 CEILING EMERGENCY LIGHT IS OUT. (FLT 1108) RELAMPED EMERGENCY LIGHT.SDR SWIA201126477Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 1147) RELAMPED EMERGENCY LIGHT.SDR SWIA201126167Light · inoperativeRIGHT MIDDLE EXTERIOR EMERGENCY LIGHT IS OUT. (SERVICE) RELAMPED EMERGENCY LIGHT.SDR SWIA201125741Light · inoperativeNR 4 AND 5 OVERHEAD EMERGENCY LIGHT ARE OUT. (FLT 6380) RELAMPED EMERGENCY LIGHT.SDR SWIA201125593Light · inoperativeNR 5 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 6716) RELAMPED EMERGENCY LIGHT.SDR SWIA201125495Light · inoperativeFORWARD 2 OVERHEAD EMERGENCY LIGHTS ARE OUT. (FLT 6768) RELAMPED EMERGENCY LIGHTS.SDR SWIA201024974Beam · corrodedFS 280 BEAM IS CORRODED BEYOND LIMITS. (C-CHECK) REPLACED BEAM PER SRM.SDR SWIA201025089Beam · corrodedFS 280 BEAM HAS CORROSION BEYOND ALLOWABLE LIMITS. (C-CHECK) REPLACED FS 280 FLOORBEAM PER SRM.SDR SWIA201024851Roller · damagedMCD DIFFICULT TO OPEN. (FLT 6495) REMOVED BURR FROM MCD AFT ROLLER.SDR SWIA201024694Acm · malfunctionedLEFT PACK FAILED AND FILLED COCKPIT WITH SMOKE. (FLT 6767) REPLACED ACM.SDR SWIA201024550Light · inoperativeCEILING EMERGENCY LIGHTS ROW 10 INOP. (FLT 6509) RELAMPED EMERGENCY LIGHTS.SDR SWIA201023791Sign · inoperativeRIGHT SIDEWALL EMERGENCY EXIT SIGN INOP. (FLT 5826) REPLACED SIGN ASSEMBLY.SDR SWIA201023594Light · inoperativeNR 3 EMERGENCY LIGHT IN CEILING INOP. (FLT 6155) RELAMPED EMERGENCY LIGHT.SDR SWIA200923212Light · inoperativeOVERHEAD EMERGENCY LIGHT INOP. (FLT 6739)RELAMPED.SDR SWIA200923036Light · inoperativeEMERGENCY OVERHEAD AISLE LIGHT, SECOND FROM AFT OF CABIN, INOP. (FLT 6114)RELAMPED.SDR SWIA200922613Light · inoperativeNR 5 EMERGENCY LIGHT INOP. (FLT 6091) RELAMPED EMERGENCY LIGHT.SDR SWIA200922512Light · inoperativeLEFT SIDE EXIT ROW EMERGENCY LIGHT INOP. (FLT 5801) RELAMPED EMERGENCY LIGHT.SDR SWIA200922223Sign · inoperativeGALLEY AND MAIN CABIN DOOR EMERGENCY EXIT SIGNS INOP. (FLT 5935) RELAMPED EMERGENCY SIGNS.SDR SWIA200922072Light · inoperativeSECOND TO LAST EMERGENCY LIGHT INOP. (FLT 5888) RELAMPED EMERGENCY LIGHT.SDR SWIA200921675Lamp · burned outFLT 6389 - CEILING EMERGENCY LIGHT NR 4 INOP. RELAMPED.SDR SWIA200921581Lamp · burned outFLT 6065 - NR 4 OVERHEAD AISLE EMERGENCY LIGHT INOP. RELAMPED.SDR SWIA200921991Beam · crackedFS280 BEAM CRACKED. (C CHECK)REPAIRED PER REO.SDR SWIA200921048Lamp · burned outFLT 6383 - LEFT LOWER EMERGENCY EXIT SIGN INOP. RELAMPEDSDR SWIA200820540Lamp · burned outFLT 5890 - CENTER OVERHEAD CABIN EMERGENCY LIGHT INOP. RELAMPED.SDR SWIA200820158Light · inoperativeEMERGENCY LIGHT ROW 9 INOP (FLT 5971). RELAMPED EMERGENCY LIGHT.
SDR SWIA200819492Fmu · leakingFLT 6617 - RIGHT ENGINE WOULD NOT MAKE POWER. REPLACED RIGHT FMU PER RJ 200 MM 73-21-03, P/N 8061-926, S/N OFF WYGB1135.
SDR SWIA200819552Floor Support · crackedCOCKPIT AFT FLOOR SUPPORT IS CRACKED, FOUND AT C-CHECK. INSTALLED NEW FLOOR SUPPORT PER CRJ700 SRM TASK 51-42-06-001-001-A01.SDR SWIA200819551Floorbeam · crackedSTA 280 BEAM IS CRACKED AT RIGHT BUTT LINE 9, FOUND AT C-CHECK. REPAIRED AREA PER CRJ700 SRM TASK 51-42-21-001-001-A01 AND REO 670-53-11-047.
SDR SWIA200718875Relay · malfunctionedEMERGENCY LIGHTS FLASH ON AND OFF IN THE ARMED POSITION, FLIGHT NR 6632. INSTALLED RELAY K135 IN JB11 PER MM 24-06-00. OPS CHECKS GOOD.SDR SWIA200717771Yoke · corrodedUPPER LINK ON FWD ENG MOUNT YOKE SHOWS SIGNS OF CORROSION INCLUDING BUSHING. REMOVED AND REPLACED HARDWARE ON YOKE IAW TASK CARD RII 72-400-1000.SDR SWIA200617362Battery Pack · failedEMERGENCY LIGHTS SLOWLY EXTINGUISH AFTER A FEW SECONDS. REPLACED NR 3 BATTERY PACK. OPERATIONAL CHECKS GOOD PER CRJ MM 33-51-17.SDR SWIA200515883Motor · malfunctionedSTAB CH 2 INOP STATUS MESSAGE OCCURRED DURING DESCENT. REPLACED HORIZONTAL STAB TRIM ACTUATOR MOTOR IAW AMM 27-42-03. OPERATIONAL CHECK GOOD.SDR SWIA200515571Sensor · malfunctionedSLATS HALFSPEED MESSAGE POSTED. REPLACED LEFT BRAKE POSITION SENSE UNIT IAW CRJ 700 AMM 27-50-00. OPERATIONAL CHECK GOOD PN ON 5912999 SNOFF 0521.