N772UA
Service difficulty reports · 240
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N772UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N772UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011021000712Unknown · odorPOSSIBLE ELECTRICAL ODOR ABOVE LAV 133. INSPECTED AREA AROUND LAV AT DOOR 3 LT AND NO OBVIOUS INDICATIONS OF ELECTRICAL ODOR, CREW REPORT ODOR CLEARED DURING TAXI.SDR UALA2011010400049Controller · faultyANTI-ICE ENG L LEFT ENGINE ANTI-ICE (EAI) VALVE FAILURE TO THE CLOSED POSITION OR LEFT EAI CONTROL CARD FAILURE. REPLACED LT ENG EAI VALVE CONTROLLER IAW MM. ACCOMPLISHED EAI TEST WITH ENG RUNNING IAW MM. ENGINE ANTI-ICE, OPS CHECKS NORMAL.SDR UALA2010122004652Exciter · inoperativeENG IGNITOR L2 LT ENGINE FAILED TO IGNITE USING IGNITOR 2. REPEAT WRITEUP MSG-7461501 INACTIVE MODE. LT ENG IGNITOR 2 INOP. REPLACED LT ENGINE NR 2 IGNITER PLUG IAW AMM. REPLACED IGNITER LEAD AND EXCITER BOX IAW AMM. PERFORMED IGNITER PLUG TEST.SDR UALA2010113004402Relay · faultyENG IGNITER L2 LEFT ENGINE FAILED TO IGNITE USING IGNITER 2. STATUS MSG-7461501 INACTIVE ES MODE. REPLACED NR 1 ENG RELAY UNIT PER MM. RAN ENG TWO TIMES WITH NO FAULTS. TESTED ERU INSTALLATION PER MM. ALL CHECKS GOOD.SDR UALA2010113004403Exciter · failedENG IGNITER L2 LEFT ENGINE FAILED TO IGNITE USING IGNITER 2. STATUS MESSAGE-7461501 INACTIVE ES MODE. REPLACED EXCITER MODULE, IGNITION LEAD AND IGNITION PLUG.SDR UALA2010111504227Engine · making metalMETAL ON CHIP DETECTORS AND FOUND IN MAIN OIL FILTER. REPLACED ENGINE.SDR UALA2010111104187Engine · making metalNR 2 ENGINE FOUND METAL CHIPS AND FLAKES ON OIL TANK CHIP DETECTOR.SDR UALA2010111004172Igniter · failedENG IGNITER L2 LEFT ENGINE FAILED TO IGNITE USING IGNITOR 2. STATUS MESSAGE-7461501 INACTIVE ES MODE. REPLACED LEFT ENGINE NR 2 EXCITER BOX. AUDIBLE OPS CHECKS GOOD. 4 ENGINE STARTS AND NO MESSAGE.SDR UALA2010111004171Connector · miswiredNR 1 ENGINE NOSE COWL ELECTRICAL CONNECTOR AT 11 O'CLOCK POSITION IS INCORRECTLY WIRED. CONNECTOR D71018J. WIRED CONNECTOR D71018J PER HOOK UP CHART AND WD 78-31-11, OPS NORMAL.SDR UALA2010102503936Engine · faultyAPU AUTO SHUTDOWN ON START. UNABLE TO GET APU BACK ON LINE. REPLACED APU. OPS GOOD.SDR UALA2010102503937Controller · faultyAPU CONT STATUS MESSAGE. REPLACED APU CONTROLLER, TESTS OKAY. MESSAGE CLEARED.SDR UALA2010101303807Check Valve · wornRT PACK, CHECK BYPASS FAN VALVE HINGE POINTS WORN. REPLACED CHECK VALVE.SDR UALA2010101303804Plenum · crackedRT PACK RAM AIR INLET PLENUM LOWER ACCESS PANEL BLOWN APART, WITH VARIOUS CRACKS IN PLENUM. REMOVED RT PACK PLENUM. BEGAN REPAIRS. REPAIRED PANEL HOLES AND CRACKS IN PLENUM.SDR UALA2010101303806Heat Exchanger · crackedRIGHT PACK HEAT EXCHANGER HAS 2 CRACKS ON UPPER AND LOWER SURFACES APPROX 5 INCHES IN LENGTH EACH. LH HEAT EXCHANGER HAS A 19 INCH CRACK AT THE 6:00 O' CLOCK POSITION. SUPPLEMENTAL DATA UPDATE REMOVED & REPLACED RH & LH PACK HEAT EXCHANGERS. ACP'D RH & LH PACKSDR UALA2010101303805Access Panel · damagedLEFT PACK RAM AIR PLENUM LOWER ACCESS PANEL FASTENER PULLED THRU. REMOVED PLENUM LOWER ACCESS PANEL. INSTALLED FIBERGLASS REPAIR TO DAMAGED AREA. INSTALLED LOWER ACCESS PANELSDR UALA2010101203796Control Valve · faultyUPPER TORQUE MOTOR NOT IN THE COMMANDED POSITION. THIS FAILURE WILL LEAD TO SERVICE DISRUPTIONS IF LT UNCORRECTED. CHECKING ASSOCIATED WIRE AND CONNECTOR FOR DEFECTS. NONE NOTED. REPLACED THE RT PACK UPPER FCV, V21512. REPLACED UPPER FLOW CONTROL AND SHUTOSDR UALA2010090303249Fire Bottle · out of toleranceBOTTLE 2A CARGO, BOTTLE 2B CARGO, AND BOTTLE 2C CARGO STATUS MESSAGES DISPLAYED ON LOWER EICAS. ACCOMPLISHED GROUND TEST 26 CARGO SQUIB TEST, TEST FAIL. CIRCUIT OPEN. REF MAT MAINT MSG FAULTS 26 -40100, 26-40110, 26-40120, REPLACED ELMS P310 I-O CARD M24406A7,SDR UALA2010080402817Circuit Card · faultyCMC NR 1 MANAGEMENT SYSTEM (ELMS) P110. HIT 3 TIMES IN HISTORY. REPLACED CARD M24400A2 IN P110 PANEL.SDR UALA2010072002606Ring · damagedRN 2 ENG. OUTER KEVLAR CONTAINMANT RING DAMAGED AT APPOX. 1 O'CLOCK POS. (UNDER RH FAN COWL). REPAIRED REF MM. ACCOMPLISHED TEMPORARY REPAIR OF OUTER ENVIRONMENTAL LAYER. TEMPORARY 50 HOUR FLYBACK REPAIR. DAMAGE WAS A CRACK AND PARTIAL TEAR APPRX 10 TO 12 INCHSDR UALA2010072002603Lens · crackedEXTERIOR EMERGENCY EXIT LIGHT LENS CRACKED AT DOOR 1 RT. INSTALLED NEW LENS ASSY.SDR UALA2010072002602Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP. AT DOOR 1 RIGHT. RELAMPED.SDR UALA2010072002601Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 3 LT RELAMPED.SDR UALA2010072002600Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 2 LT. RELAMPED.SDR UALA2010060902002Fseu · faultyEICAS HAS STATUS MSG FLAP-SLAT CONTROL 1. DURING T-S EXISTING FAULT HAS HIGH LIFT SYS (FSEU 1 PROGRAM PINS ARE INCORRECT) . CONFIG SHOWS A-P MODEL INVALID. REPLACED FSEU 1. SYS CONFIG SAME AS FSEU2. TEST PASSED AND EICAS CLEARED.SDR UALA2010060801994Warning Message · illuminatedFLAP SLAT FSEU NR 2 HAS NO OUTPUT ON SYS ARINC 629 BUS (RT) STATUS MESSAGE FLAP-SLAT CONTROL NR 2. CYCLED P210 CB'S, F21, K4, K5 AND K9 AND PERFORMED GROUND TEST "27 HIGH LIFT SYS PRIMARY SYS TEST-FSEU 2". TEST PASSED.SDR UALA2010051901689Duct · failedRT WING OVHT, RTFL. FOUND BLOWN DUCT RT-PACK BAY. DAMAGE TO 4-DUCTS AND SEVERAL STANDOFFS. DUCTS RMV'D. DUCTS AND STANDOFFS ON AOG. DUCTS INSTALLED, RUNS GOOD. PREPPING TO CLOSE PANELS. FOUND RT ENG PNEU MANIFOLD FAILED. DAMAGED 4-DUCTS AND SEVERAL STANDOFFSSDR UALA2010051301628Light · missingAT SEAT 1F THE EMERGENCY FLOOR LIGHTING IS MISSING. REPLACED MISSING LIGHT, OP CHECKS GOOD.SDR UALA2010020800498Line · crackedNR 2 ENG VENT LINE TO THE RESTRICTOR VALVE ON THE DEOILER CRACKED. LINE IS NR 3 BEARING RESTRICTOR VALVE AP39 AIR SUPPLY TUBE. NEW LINE ON AOG. REMOVED NR 3 BEARING RESTRICTOR VALVE AP39 SUPPLY LINE. REMOVED PARTS IN AREA. REPLACED LINE.SDR UALA2010011200150Transducer · reads lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: INTERMITTENT O2 LOW INDICATION. EICAS AND STATUS MESSAGE. FOUND 1500 PSI ON BOTTLE, SERVICED BOTTLE TO 1900PSI NO LEAKS NOTED AROUND BOTTLE, SUSPECT INDICATION SEE HISTORY. ACCOMPASDR UALA2009101903257Idg · failedELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). ADVISORY FOUND RT IDG OVERFILLED. SERVICED CORRECTLY. RECONNECTED IDG. RAN ENGINE. IDG INOP. REPLACED RIGHT IDG. SECURED ALL ELECTRICAL OIL CONNECTIONS AND SAFTIED QUAD RING AND OPS CKED. OP CSDR UALA2009051801409Oxygen Mask · faultyOXYGEN MASK PROBLEM CREW COMMENTS, MASK WILL NOT DEFLATE MASK STAYS INFLATED. OK TO CONTINUE SECOND OBSERVERS SEAT INOP. DUE TO O2 MASK INOPERATIVE, MISSING. REPLACED O2 MASK, OP'S CK'D NORMAL. OLD UNIT REMOVED AT IAD.SDR UALA2009043001256Light · inoperativeSEAT 32C EMERGENCY LIGHT IS OUT. REPLACED LIGHT ASSEMBLY.SDR UALA2009043001255Lamp · inoperativeEXT EMERGENCY LIGHT IS OUT. RELAMPED.SDR UALA2009043001254Light · missingSEAT 13F AFT EMERGENCY LIGHT IS MISSING. SUPPLEMENTAL DATA UPDATE, REPLACED LIGHT ASSEMBLY.SDR UALA2009042401192Actuator · failedLEFT WING FUEL JETTISON VALVE LEAKING AND PANEL REMOVED FROM BOTTOM OF WING, PANEL 543AB. REPLACED VALVE AND ACTUATOR. NEEDS OPS CHECK.SDR UALA2009031200771Battery · faultySTATUS PAGE FLIGHT CONTROL SYSTEM. REPLACED LEFT FLIGHT CONTROL BATTERY.SDR UALA2008120106699Valve · defectiveCREW REPORTS: FLIGHT ATTENDANT REPORTED ABNORMAL SOUND FROM ENG 1 DURING START, CREW SHUTDOWN ENG, RESTART WITH SAME RESULTS, NO REPORT OF ANY ABNORMAL ENG PARAMETERS OR EICAS MESSAGES, ENGINE WAS RUN AT 50% N1 WITH ALL PARAMETERS NORMAL. ACCOMPLISH CHECKS WSDR UALA2008112106605Cylinder · low pressureINFLATION CYLINDER OUT OF GREEN BAND. IMPROPER CYLINDER FILL. TOP OFF CYLINDER.SDR UALA2008111706519Light · inoperativeEXTERIOR EMERGENCY LIGHTS ON DOORS 3 AND 4 LT INOP. RELAMPED EMERGENCY LIGHTS ON DOORS 3 AND 4 LEFT, OPS CHECK OK.SDR UALA2008111706518Connector · not seatedAFT EEL LIGHT ON SEAT 3E INOP. RESEATED CONNECTOR, OPS CHECK OK.SDR 2008UALA06047Battery · faultySTATUS MSG APU BATTERY. REPLACED BATTERY, NO HELP. RELOADED ELMS P310 ELECTRONIC UNIT OPC AND OPS SWICH PER MM24-09-00. THIS CLEARED STORED FAULTS. AFTER RELOAD ACCPLISHED TEST OF APU BATTERY & CHAGER TO ENSURE PROPER OPS. NO MESSAGES FOUND ON EICAS. ACCOMPLISDR 2008UALA06046Charger · malfunctionedSTATUS MSG BATTERY CHARGER APU. REPLACED-CHARGER, NO HELP. RELOADED ELMS P310 ELECTRONIC UNIT OPC AND OPS SW PER MM24-09-00 PG201 THIS CLEARED THE FAULTS. AFTER RELOAD ACCOMPLISHED TEST OF APU BATTERY & CHARGER. RAN APU FOR HALF HOUR AND THE APU BAT CHARGER SDR 2008UALA05979Lamp · inoperativeTHE 1E SIDE WALL EMERGENCY LIGHT FELL OFF. REPLACED LAMP. TESTED GOOD.
SDR 2008UALA05848Attach Fitting · crackedLT ELEVATOR OTBD PCA ATTACH FITTING IS CRACKED AT LWR CORD INBD LUG, ON ELEVATOR, BY- 80904. LT ELEVATOR REPLACED WITH SERVICEABLE LEASED UNIT ON OV W-US. RIGGED AND OP CHECKED.SDR 2008UALA03237Light · missingSEAT 1F AFT EMERGENCY LIGHT ASSY MISSING. LIGHT ASSY REPLACED AND TESTED NORMAL.SDR 2008UALA03236Light · missingSEAT 1E AFT EMERGENCY LIGHT MISSING. EMERGENCY LIGHT ASSY REPLACED AND TESTED OK.SDR 2008UALA02700Charger · faultyAPU BATTERY CHARGE MESSAGE DISPLAYED ON EICAS. SUSPECT FAULTY BATTERY CHARGER. REPLACED BATTERY CHARGER PER MM 24-31-06. AC OK FOR SERVICE.SDR 2008UALA02729Converter · faulted"MANUALLY INITIATED ENGINE START TEST". THIS TEST GIVES FAULT, "BACKUP CONVERTER HAS INTERNAL FAULT". SUSPECT FAULTY CONVERTOR. REPLACED BACK UP GENERATOR CONVERTER PER MM 24-25-09. PASSED TEST PER MM 24-25-00. AC OK FOR SERVICE.SDR UALA2008111301965Warning Message · illuminatedFOUND FLT CONTROL SYS STATUS MESSAGE LATCHED WITH NO CORRELATED MESSAGES. FOUND MESSAGE 31-54102. RPL IOM M004, NO HELP. SUSPECT ARINC 629 COUPLER B31208 IN P212 PANE. *NOTE* TURNED ON ALL HYD SYS PER MT 27-005-R1, NO HELP. *NOTE* MSG CAN BE CLEARED BY SDR 2008UALA01965Warning Message · illuminatedFOUND "FLIGHT CONTROL SYSTEM STATUS MESSAGE" LATCHED WITH NO CORRELATED MESSAGES.
Back to N772UA