N7741C
Service difficulty reports · 233
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7741C' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7741C' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024112149364Floor Panel · delaminatedCABIN FLOOR PANEL 221EF CORRODED INSERTS AND TOP SURFACE DELAMINATION.<[01] CABIN FLOOR PANEL 221EF WITH CORRODED INSERTS AND TOP SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02SDR SWAA2024112149370Floor Panel · delaminatedCABIN FLOOR PANEL 222BF CORRODED INSERTS AND TOP SURFACE DELAMINATION.<[01] CABIN FLOOR PANEL 222BF WITH CORRODED INSERTS AND TOP SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02SDR SWAA2024112149371Floor Panel · delaminatedCABIN FLOOR PANEL 222AF CORRODED INSERTS AND TOP SURFACE DELAMINATION.<[01] CABIN FLOOR PANEL 222AF WITH CORRODED INSERTS AND TOP SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02SDR SWAA2024112149376Floor Panel · debondedCABIN FLOOR PANEL 241CF TOP SURFACE IS DISBONDED.<[01] CABIN FLOOR PANEL 241CF TOP SURFACE WITH DISBONDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024112149545Floor Panel · delaminatedCABIN FLOOR PANEL 241UF HAS TOP SURFACE DELAMINATION.<[01] CABIN FLOOR PANEL 241UF WITH TOP SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024112149552Floor Panel · delaminatedCABIN FLOOR PANEL 241AAF HAS TOP SURFACE DELAMINATION.<[01] CABIN FLOOR PANEL 241AAF WITH TOP SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024112548844Attach Angle · crackedB.S. 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IS CRACKED AT L.B.L. 45; W.L. 165.<[01] REMOVED; REPLACED; AND INSTALLED NEW B.S. 663 VAPOR BARRIER UPPER ATTACH ANGLE PER SRM 51-40-02-0G-0; AND DWG 111A1000 REV: A.;[02] VERIFIED ACTION ITEMS AND TASK CARDSDR SWAA2024112548845Attach Angle · crackedB.S. 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IS CRACKED AT R.B.L. 45; W.L. 165.<[01] REMOVED; REPLACED; AND INSTALLED NEW B.S. 663 VAPOR BARRIER UPPER ATTACH ANGLE PER SRM 51-40-02-0G-0; AND DWG 111A1000 REV: A.;[02] VERIFIED ACTION ITEMS AND TASK CARDSDR SWAA2024112548846Attach Angle · crackedB.S. 663 VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT R.B.L. 8 W.L. 165.<[01] CRACK FOUND TO BE OUT OF LIMITS AS PER SRM 57-10-10-1A-2. PART WILL BE REMOVED AND REPLACED ON FAULT TTG8Q00WF907.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024112548843Attach Angle · crackedB.S. 663 VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT L.B.L. 8 W.L. 165.<[01] CRACK FOUND TO BE OUT OF LIMITS AS PER SRM 57-10-10-1A-2. PART WILL BE REMOVED AND REPLACED ON FAULT TTG8Q00WF8ZU.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024112148790Vapor Barrier · delaminatedL/H 663 VAPOR BARRIER HAS A PREVIOUS REPAIR THAT IS DELAMINATING 'MARKED'<[01] L/H BS 663 VAPOR BARRIER WAS REPAIRED IAW SRM 51-70-04-2R-10;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024112149043Floor Panel · delaminatedCABIN FLOOR PANEL 231DF UPPER SURFACE IS DELAMINATED.<[01] UPDATED STEP 1;[02] UPDATED STEP 1.;[03] REMOVED AND INSTALLED NEW FLOOR PANEL 231DF IAW AMM 53-21-00-000-801 AND AMM 53-21-00-400-801.;[04] VERIFIED ITEM 3 AND TASK CARD COMPLETED.SDR SWAA2024112149044Floor Panel · delaminatedCABIN FLOOR PANEL 231GF UPPER SURFACE IS DELAMINATED.<[01] UPDATED STEP 1;[02] UPDATED STEP 1.;[03] REMOVED AND INSTALLED NEW FLOOR PANEL 231GF IAW AMM 53-21-00-000-801 AND AMM 53-21-00-400-801.;[04] VERIFIED ITEM 3 AND TASK CARD COMPLETED.SDR SWAA2024112149040Floor Panel · delaminatedCABIN FLOOR PANEL 231KF UPPER SURFACE IS DELAMINATED.<[01] UPDATED STEP 1;[02] UPDATED STEP 1.;[03] REMOVED AND INSTALLED NEW FLOOR PANEL 231KF IAW AMM 53-21-00-000-801 AND AMM 53-21-00-400-801.;[04] VERIFIED ITEM 3 AND TASK CARD COMPLETED.SDR SWAA2024112149045Floor Panel · delaminatedCABIN FLOOR PANEL 231XF UPPER SURFACE IS DELAMINATED.<[01] REMOVED AND INSTALLED NEW FLOOR PANEL 231XF IAW AMM TASK 53-21-00-000-801 PAR. 2. E.; AMM 53-21-00-400-801;[02] REMOVED AND INSTALLED NEW FLOOR PANEL 231XF IAW AMM TASK 53-21-00-000-801 PAR. 2. E.; AMMSDR SWAA2024112149042Floor Panel · delaminatedCABIN FLOOR PANEL 241DF UPPER SURFACE IS DELAMINATED.<[01] REMOVED AND INSTALLED NEW FLOOR PANEL 241DF IAW AMM 53-21-00-400-801; AMM TASK 53-21-00-000-801 PAR. 2. E.;[02] REMOVED AND INSTALLED NEW FLOOR PANEL 241DF IAW AMM 53-21-00-400-801; AMM TASK 53-21-00-0SDR SWAA2024112149041Floor Panel · delaminatedCABIN FLOOR PANEL 241AF UPPER SURFACE IS DELAMINATED.<[01] CABIN FLOOR PANEL 241AF IS TO BE INSTALLED ON CARD TTG8Q00VS4JJ;[02] REMOVED AND FABRICATED NEW CABIN FLOOR PANEL DUE TO DAMAGE IAW SRM 53-00-50-0I-1 FIG 4 TABLE 4; SRM 53-00-50-1A-1 PARA 2. A. NOTE: SSDR SWAA2024112149046Floor Panel · delaminatedCABIN FLOOR PANEL 241KF UPPER SURFACE IS DELAMINATED.<[01] UPDATED STEP 1;[02] COMPLETE.;[03] UPDATED STEP 1.;[04] COMPLETED STEP 1.;[05] REMOVED AND INSTALLED NEW FLOOR PANEL 241KF PER AMM 53-21-00-000-801 AND PER AMM 53-21-00-400-801.;[06] VERIFIED ITEM 5 ANSDR SWAA2024112149048Floor Panel · delaminatedCABIN FLOOR PANEL 241RF UPPER SURFACE IS DELAMINATED.<[01] UPDATED STEP 1;[02] UPDATED STEP 1.;[03] UPDATED STEP 1;[04] REMOVED OLD FLOOR PANEL AND INSTALLED NEW FLOOR PANEL 241RF PER AMM 53-21-00-000-801 AND AMM 53-21-00-400-801;[05] VERIFIED STEP 1 CORRECTIOSDR SWAA2024112149047Floor Panel · delaminatedCABIN FLOOR PANEL 241NF UPPER SURFACE IS DELAMINATED.<[01] UPDATED STEP 1;[02] UPDATED STEP 1.;[03] COMPLETED STEP 1.;[04] REMOVED AND INSTALLED NEW FLOOR PANEL 241NF PER AMM 53-21-00-000-801 AND PER AMM 53-21-00-400-801.;[05] VERIFIED ITEM 4 AND TASK CARD COMSDR SWAA2024112548619Vapor Barrier · crackedDELAMINATING VAPOR BARRIER BS 663 LBL 24.92 (MARKED)<[01] CRACK DAMAGE ON L/H BS 663 VAPOR BARRIER TO BE ACCOMPLISHED ON FAULT#TTG8Q00WF5TG.;[02] VERIFIED JOB COMPLETESDR SWAA2024112548620Vapor Barrier · crackedCRACKED ANGLE ATTACH VAPOR BARRIER WING CENTER SECTION REAR SPAR AT BS 663 RBL 45. CRACK FOUND TO BE OUT OF LIMITS AS PER SRM 57-10-10-1A-2. PART WILL BE REMOVED AND REPLACED ON FAULT TTG8Q00WF907.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024112148618Vapor Barrier · crackedCRACKED PREVIOUS REPAIR VAPOR BARRIER BS 663 RBL 25 TO RBL 40 (MARKED)<[01] CRACK DAMAGE ON BS 663 VAPOR BARRIER TO BE ACCOMPLISHED ON FAULT#TTG8Q00WF5TG.;[02] CORRECTION TO ITEM 1: WRITTEN IN ERROR.;[03] CRACKED VAPOR BARRIER WAS REPAIRED AT BS 663 RBL 25 - 4SDR SWAA2024112148621Plate · damagedASD AFT GRIT BAR FITTING PLATE DAMAGED.<[01] COMPLETED REPLACED ASD AFT GIRT BAR FITTING PLATE IAW AMM 25-66-02-400-801;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024112148622Bracket · looseFSD SLIDE COVER GRIT BAR FITTING ATTACHMENT FWD & AFT BRACKET RIVETS LOOSE<[01] REMOVED AND REPLACED FWD & AFT BRACKET RIVETS ON FSD SLIDE COVER GRIT BAR FITTING ATTACHMENT IAW SRM 51-40-02-0G-0;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024081626275Vapor Barrier · crackedDURING REINSPECT OF STA 663.75 R/H SIDE LOWER WEB (VAPOR BARRIER) APROX RBL 50; FOUND ADDITIONAL DAMAGE. FOUND CRACK @ STA 663 APPROXIMATELY RBL30.5 - RBL 42.5. REF TTG8Q00T5HM0.<[01] REPAIR ACCOMPLISHED ON TTG8Q00V9DTC.;[02] REPAIR ACCOMPLISHED ON TTG8Q00V9DTSDR SWAA2023081588209Girt Bar · looseL1 DOOR AFT GIRT BAR HANGER LOOSE<[01] SECURED L1 DOOR AFT GIRT BAR HANGER PER SRM 51-40-02SDR SWAA2023081588200Battery Pack · failed inspEMX BATT PACK M02400 FAILS CAPACITY CHECK<[01] REMOVED AND REPLACED EMX BATT PACK M02400 PER AMM 33-51-06SDR SWAA2023081588199Battery Pack · failed inspEMX LIGHT BATT PACK M01673 FAILS CAPACITY CHECK<[01] REMOVED AND REPLACED EMX LIGHT BATT PACK M01673 PER AMM 33-51-06SDR SWAA2023081588194Battery Pack · failed inspEMX BATT PACK M01669 FAILS CAPACITY CHECK<[01] REMOVED AND REPLACED EMX BATT PACK M01669 PER AMM 33-51-06SDR SWAA2023042029061Cover · missingFWD SERVICE DOOR LOWER EMERGENCY LIGHT LENS MISSING DIRECTIONAL ARROW FWD ENTRY DOOR LOWER EMERGENCY LIGHT LENS MISSING DIRECTIONAL ARROW<[01] REMOVED AND REPLACED COVER IAW AMM 33-51-01;[02] INSPECTEDSDR SWAA2023042029058Cover · missingFWD ENTRY DOOR LOWER EMERGENCY LIGHT LENS MISSING DIRECTIONAL ARROW<[01] REMOVED AND REPLACED COVER IAW AMM 33-51-01;[02] INSPECTEDSDR SWAA2023030110551Slide · out of limitsFORWARD SERVICE DOOR SLIDE PRESSURE NOT IN THE GREEN SERVICEABLE BAND<[01] REMOVED AND REPLACED FWD SERVICE DOOR ESCAPE SLIDE PER MT 725-61-06 AND AMM 25-60-01.SDR SWAA2022120678200Connector · unsecureR1 LOWER EMERGENCY EXIT LOCATOR SIGN INOP. / [01] PERFORMED T/S AS PER B737 WDM 33-51-21 AND FOUND NOT PROPERLY SECURED CONNECTOR D3660 AT R1 LOWER EMERGENCY EXIT LOCATOR (L1186); RE-SECURED CONNECTOR AND PERFORMED EMERGENCY LIGHTS - OPERATIONAL TEST AS PER B7SDR SWAA2022120777862Battery Pack · inoperativeSEVERAL PASSENGER CABIN EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY PACKS AT M1670, M1674, AND M1675 IAW AMM 33-51-06-960-805. PERFORMED EMERGENCY LIGHT OPS TEST IAW AMM 33-51-06-960-805. TESTED OK.SDR SWAA2022120771625Light · brokenMAIN CABIN L/H SIDEWALL PANEL 231YHW EMERGENCY EXIT LIGHT HOUSING BROKEN. REMOVED AND REPLACED THE EMERGENCY EXIT LIGHT HOUSING IAW AMM 33-51-01-960-802, ACCOMPLISHED STEPS C - C.5 AND C.5.D - C.6.E. PERFORMED OPERATIONAL TEST IAW AMM 33-51-01-960-802. TESTESDR SWAA2022120771121Shield · corrodedFWD CARGO BAY, BS 490 - 500A, S25R, RBL 21, SHIELD CORRODED. RECEIVED, LOCATED, AND DRILLED A NEW SHIELD IAW SRM 51-40-05-0G-0. INSTALLED IAW TASK CARD TTG8Q004GFW7.SDR SWAA2022120670876Floor Support · crackedMAIN CABIN BS312 TO BS328 RBL 30 WL 208.1 FLOOR SUPPORT CRACKED. REMOVED THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0. FOUND OUT OF LIMITS IAW SRM 53-00-04-1A-1 FIG.102 DETAIL H. APPLIED TREAT AND PRIMER IAW AMM 51-21-41-370-802 AND AMM 51-21-72-370-804. INSTASDR SWAA2022120969754Floorbeam · corrodedFLOORBEAM, BS 986.5, RBL 45, FASTENER HOLE HAS A SPOT OF CORROSION. FOUND OUT OF LIMITS IAW SRM 53-70-51-1A-1. REMOVED THE FLOORBEAM IAW SRM 51-40-02-0G-0, FABRICATED A NEW TEE IAW SRM 53-70-51-2R-4, REPAIR 4. LOCATED AND DRILLED IAW SRM 51-40-05. ACCOMPLISDR SWAA2022120669747Floor Support · crackedMAIN CABIN BS277 TO BS294.5 RBL 1 WL 208.1 INTERCOSTAL CRACKED AT 2 LOCATION / [01] REMOVED INTERCOSTAL CRACK AT MAIN CABIN BS. 277 TO BS. 294.5 RBL. 1. REF. SRM. 51-40-02-0G-0.;[02] VERIFIED; STEP # 1.;[03] RECEIVE; LOCATED AND DRILLE HOLES IN NEW INTERCOSTALSDR SWAA2022120669755Floor Support · crackedMAIN CABIN BS380 TO BS400 LBL 1 WL 208.1 INTERCOSTAL CRACKED / [01] REMOVED ANGLE SUPPORT AT MAIN CABIN BS 380 TO BS 400 LBL 1 WL 208.1 REF SRM 51-40-02-0G-0;[02] CORRECTION STEP;# 1: REMOVED INTERCOSTAL UPPER CHORD (ANGLE SUPPORT) AT MAIN CABINBS380 TO BS400 SDR SWAA2022120669749Floor Support · crackedMAIN CABIN BS380 TO BS400 LBL 14 WL 208.1 INTERCOSTAL CRACKED / [01] REMOVED ANGLE SUPPORT AT MAIN CABIN BS 380 TO BS 400 LBL 14 WL 208.1 REF SRM 51-40-02-0G-0;[02] VERIFIED 1. OK TO INSTALL INTERCOSTAL UPPER CHORD (ANGLE SUPPORT);[03] INSTALLED INTERECOSTAL USDR SWAA2022120669750Floor Support · crackedMAIN CABIN BS380 TO BS400 RBL 9 WL 208.1 INTERCOSTAL CRACKED / [01] REMOVED ANGLE SUPPORT OF INTERCOSTAL AT MAIN CABIN BS380 TO BS400 RBL 9. REF; SRM. 51-40-02-0G-0;[02] CORRECTION STEP.#1: REMOVED INTERCOSTAL UPPER CHORD (ANGLE SUPPORT) AT MAIN CABIN BS380 TOSDR SWAA2022120669751Floor Support · crackedMAIN CABIN BS380 TO BS400 RBL 40 WL 208.1 INTERCOSTAL CRACKED / [01] REMOVED ANGLE SUPPORT OF INTERCOSTAL AT MAIN CABIN BS380 TO BS400 RBL. 40; REF. SRM. 51-40-02-0G-0;[02] CORRECTION STEP. 1:REMOVED INTERCOSTAL UPPER CHORD (ANGLE SUPPORT) AT MAIN CABIN BS380 SDR SWAA2022120669752Floor Support · corroded'CORROSION' MAIN CABIN BS294.5 +10 LBL 12 WL 208.1 INTERCOSTAL SPOT OF CORROSION / INTERCOSTAL FOUND OUT LIMITS. REMOVED INTERCOSTAL IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED THE NEW INTERCOSTAL IAW SRM 51-40-02-0G-0. APPLIED TREAT AND PRIMER IAW AMM 51-21SDR SWAA2022120669369Scuff Plate · crackedFWD CARGO DOOR CUT OUT SCUFF PLATE FWD CORNER WITH CRACK DAMAGED / [01] RECEIVED NEW SCUFFPLATE FOR REPLACE P/N 654A0004-337 PO#:1772343;[02] LOCATED; DRILLING AND COUTERSINK HOLES TO NEW SCUFFPLATE FOR REPLACE REF.737-700-SRM 51-40-02-0G-0;[03] FWD CARGO SCUFSDR SWAA2022120669370Scuff Plate · crackedFWD CARGO DOOR CUT OUT SCUFF PLATE AFT CORNER WITH CRACK DAMAGED / [01] RECEIVED NEW SCUFFPLATE FOR REPLACE P/N 143A8331-4 PO#:1728471;[02] VERIFIED 1;[03] LOCATED; DRILLING AND COUTERSINK TO NEW SCUFFPLATE FOR REPLACE REF.737-700-SRM 51-40-02-0G-0;[04] REF TASDR SWAA2022120769048Panel · crackedLEFT WING PANEL 561BB HAS SEVERAL FASTENERS HOLE ARE CRACKED. PREPARED DAMAGED AREA TO APPLY THE FABRIC REPAIR PLIES, NO WATER NOTE AT ACCESS PANEL 561BB IAW SRM 51-70-04-2R-9, REPAIR 9, PARAGRAPH 4 C, D, E, F, G, H, AND I. REPAIRED DAMAGED AREA IAW SRM 51-7SDR SWAA2022120768930Fairing · damagedPANEL 193B FWD EDGE HAVE ENLONGATED HOLES. PREPARED AREA FOR REPAIR IAW SRM 51-70-04-2R-9. REPAIRED THE FAIRING PANEL IAW SRM 51-70-04-2R-9.SDR SWAA2022120768931Access Panel · damagedLEFT HORIZONTAL STAB LOWER T/E ACCESS PANEL 333CB HAD ELONGATED FASTENER HOLES. PREPARED DAMAGED AREA TO APPLY FABRIC REPAIR PLIES. NO WATER NOTE AT ACCESS PANEL IAW SRM 51-70-04-2R-9, REPAIR 9, PARAGRAPH 4 C, D, E, F, G, H, AND I. REPAIRED DAMAGED AREA AT