N778UA
Service difficulty reports · 197
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N778UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N778UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025111011096Battery Pack · no testBATTERY PACK, M33408, ABOVE 4R DOOR REPLACEMENT REQUIRED DUE TO 15 MINS BATTERY TEST FAILURE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-802. OPS CHECKED GOOD.SDR CALA2025111011094Battery Pack · no testBATTERY PACK, M33409 ABOVE 4R DOOR REPLACEMENT REQUIRED DUE TO 15 MINS BATTERY TEST FAILURE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-802. OPS CHECKED GOOD.SDR CALA2025111011092Battery Pack · no testBATTERY PACK, M33096 ABOVE 2L DOOR REPLACEMENT REQUIRED DUE TO 15 MINS BATTERY TEST FAILURE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-802. OPS CHECK GOOD.SDR CALA2025111011090Battery Pack · no testBATTERY PACK M33093 ABOVE 1L DOOR REPLACEMENT REQUIRED DUE TO 15 MINS BATTERY TEST FAILURE. REPLACED THE BATTERY PACK, IAW AMM 33-51-06-960-802. OPS CHECK GOOD.SDR CALA2025092909363Actuator · faultedDOOR FLIGHT LOCK 2R EICAS STATUS #2 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SEN SOR DISAGREEMENT.DB PSEU 2 (R2) DB PSEU 2 (L2) SAME 3 FAULTS AS PREVIOUS LEG, REF FIM 52-11 TASK 806. PERFORMED FLIGHT LOCK CONTROL TEST PER AMM 52-11-26-740-801 SDR CALA2025092909359Warning Message · intermittentDOOR FLIGHT LOCK 2R EICAS STATUS #2 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RELAY SENSOR DISAGREEMENT. PSEU 2 (R2) CMC MSG 5212130 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: INITIAL CLIMB DOOR FLIGHT LOCK 2R STATUS MSG ERASED , OK TO CONTINUESDR CALA2025010601803Girt Bar · fod1L DOOR ARMING INDICATION IS ABNORMAL INSPECTED AND CLEANED DOOR 1L GIRT BAR LOWER DOOR ARMED INDICATORS, CYCLED ARM LEVER SEVERAL TIMES, CHECKS OK, REFERENCE: TASK 52-11-17-200-801.SDR CALA2024102800944Charger · faultedCB H11 EMERGENCY LTS 1R AND 2L POPPED FOUND CAUSE TO BE THE BATTERY PACK CHARGER M33099 BAD AND BURNING.PARTS USED: 29-3351-3-0031, QTY :1 99-3351-3-0015, QTY :1 REPLACED BATTERY CHARGER PACK AND BATTERY.SDR CALA2024090302373Battery Pack · dischargedDOOR L1 EMERGENCY LIGHT BATTERY M33093 TEST FAIL TRANSFER REF. DR L1 EMER LIGHT BATTERY M33093 REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06.SDR CALA2024090502389Spar · crackedEA5310-07557 REV A OP002 - 1EA HOLE FOUND CRACK AT LH BS1035 CENTER TANK FRONT SPAR WEB TRANSFER REF. NON-ROUTINE HX NRC WO.3636415 AND ORIGINATED BY EMP NO. V897470 LH BS1035 CENTER TANK FRONT SPAR WEB REPAIRED AND LOWER CHORD REPAIRED AS PER ECRA 5710-02889 SDR CALA2024090502388Spar · crackedRH BS1035 CENTER TANK FRONT SPAR 1EA HOLE CRACK WAS FOUND ON THE WEB LAYER APPROX 0.040" AT 6 O`CLOCK POSITION. RH BS1035 CENTER TANK FRONT SPAR WEB REPAIRED AS PER ECRA 5710-02890 REV- PART 1 ITEM 1 INTERIM REPAIR, AND SPAR LOWER CHORD REPAIRED REFER HX NRCSDR CALA2024090402384Spar · crackedTWO HOLES FOUND CRACKED AT RT BS1035 CENTER TANK FRONT SPAR LOWER CHORD. CENTER TANK FRONT SPAR LOWER CHORD REPAIRED AS PER SRM 57-10-10-2R-1 REPAIR 1.SDR CALA2024090402383Spar · crackedTHREE HOLES FOUND CRACKED AT RH BS1035 CENTER TANK FRONT SPAR LOWER CHORD. LH BS1035 CENTER TANK FRONT SPAR LOWER CHORD REPAIRED AS PER SRM 57-10-10-2R-1 REPAIR 1.SDR CALA2024070301956Screw · missingPDA 3 REFRENCE LOG# 8453862 LEFT SIDE SLAT LINKAGE FAIRING PANEL ONE SCREW MISSING ENTERED IN ERROW SHOULD BE CATAGORY 3 REF LP 8457515 FOR CORRECT PDA CATEGORY 3 LOG ENTRY. PDA 3 SCREW FOUND MISSING FROM PANEL 511CB (LEFT SIDE SLAT LINKAGE PANEL)SDR CALA2023090602721Unknown · faultyAPU EICAS STATUS APUC DETECTED FAULT THAT WOULD CAUSE AUTOMATIC SHUTDOWN OF APU IN UNATTENDED MODE OPERATION, OR COMPLETE LOSS OF APUC BUS ACTIVITY (BOTH L AND R 629) FOR 3 SECONDS AFTER THE APU MASTER CONTROL SWITCH HAS BEEN IN THE ON POSITION FOR TEN SECONDSSDR CALA2023090502712Feeder Cable · brokenENG GEN R TRIPPED/RESET TRIPPED/REMAINED OFF INOPERATIVE STICKER ADJACENT TO THE ASSOCIATED GEN CTRL SWITCH ON THE OVERHEAD ELECTRICAL PANEL APPLIED PER MEL. PERFORMED R ENG GENERATOR DISCONNECT PROCEDURE PER MEL 2411A SECTION B NOTE - R ENG UPPER TERMINAL BLOSDR CALA2023083002663Lever · unknownREJECTED TAKEOFF AT 10 KNOTS DUE TO FAILURE OF LEFT ENG TO ACCEL ERATE 22-31-00, BOTH TEST PSSED AND NO AUTOTHROTTLE FAULTS. FLT CREW REPORT: WITH AUTOTHROTTLE ENGAGED BOTH THRUST LEVERS NOTE: AUTOTHOTTLE REPONDED NORMALLY WHEN TOGA SWITCH WAS ADVANCED NORMALLSDR CALA2023051901559Light · crackedFOUND R4 DOOR CLASS DIVIDER 3EA FLOOR PROXIMITY LIGHT LENS CRACK ED REF HAECO NON-ROUTINE NO.9457447. R4 DOOR CLASS DIVIDER 3EA FLOOR PROXIMI TY LIGHT REPLACED AND OP TEST FOUND NORMAL REF AMM 33-51-05-960- 802 REV 97.SDR CALA2023051901558Battery · failedDURING PERFORMED EMERGENCY LIGHTING BATTERY PACK CAPATITY CHECK FOUND L1 AND R1 MASTER CALL LT /EXIT SIGN STAY ON ONLY 4 MINUTES REFER HAECO NON-ROUTINE NO.9457091. REPLACED M33093 BATTERY PACK AND PERFOR MED TEST FOUND NOMAL REF AMM 33-51-06-960-802 REV 97.SDR CALA2023051901557Lens · crackedFOUND L1 DOOR CLASS DIVIDER 1EA FLOOR PROXIMITY LIGHT LENS CRACK ED REFER HAECO NON-ROUTINE NO.9457451. L1 DOOR CLASS DIVIDER 1EA FLOOR PROXIMI TY LIGHT REPLACED AND OP TEST FOUND NORMAL REF AMM 33-51-05-960- 802 REV 97.SDR CALA2023051901556Light · missingFOUND L4 DOOR CTR CLASS DIVIDER 1EA PROXIMITY LIGHT LENS MISSING REFER HAECO NON-ROUTINE NO.9457092 - ORIGINATED BY EMP V903179 SPEC NO.B777-33-3-7019 PERFORMED BY EMP V903179 L4 DOOR CTR CLASS DIVIDER 1EA PROXIMITY LIGHT REPLACED AND OP TEST FOUND NORMAL REF SDR CALA2022080801993None · faulty#1 ENG HAS REPEAT FAULTS FOR HIGH OIL TEMP ADVISORY IN CLIMB. REMOVED AND REPLACED ADAPTER TUBE TO BOSS AND WASHER. PERFORMED HIGH POWER ENGINE RUN AND FOUND TO BE OPERATING NORMALLY.SDR CALA2021090601516Skin · damaged4R DOOR OUTER SKIN REPAIRED AT LOWER CORNER REFERENCE HAECO LOG PAGE 9453134 JOB NO ZUN0448 INSTALLED NEW REPAIR PER ECRA 5211-0 1721. AS PER PART 1 INTERIM REPAIR STEP 2 GENERATE A DTA/DIP LOG PAGE TO ACCOMPLISH THE INSPECTION PER LATEST REVISION OF ECRA 5 21SDR CALA2021090601508Battery Pack · failedDURING DEEP-CYCLE,FOUND L1 DOOR FWD EMERGENCY LT BATTERY PACK M33093 CAN NOT OPERATE FOR A MINIMUM OF 15 MINUTES, REPLACED L1 DOOR FWD EMERGENCY LT BATTERY PACK M33093 CARRY OUT THE NEW BATTERY PACK TEST RESULT ''NORMAL'' REF AMM 33-51-06-960-802 REV.92A.SDR CALA2021090601507Light · crackedFND DOOR 4 PARTITION L/H AND R/H EMERGENCY PROXIMITY LT ASSY CRACK. REPLACED DOOR L4 & R/H PARTITION EMERGENCY PROXIMITY LT CONDITION CHK NORMAL CARRY OUT EMERGENCY LT TEST TEST RESULT NORMAL REF AMM 33-51-05- 960-802 REV.92A.SDR CALA2019121602209Wire · exposedEMERGENCY EXIT LIGHT MISSING SEAT 1D EXPOSED WIRE NEED TIME. EMERGENCY EXIT LIGHT MISSING SEAT 1D - MEL 3351S STOWED LITE ASSY AND SECURED WIRES. PLACED ON MEL. DDP C/W. REPLACED EMER LIGHT ASSEMBLY AT SEAT 1D,OPS NORMAL. VERIFIED INSTALL, SECURETY AND OPS SDR CALA2018070301564Power Supply · failedRR DOOR 1 M33096 EMER CAPACITY CHECK FOUND FAIL. RT DOOR 1 M33096 EMER LT POWER SUPPLY REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2018062501518Battery · dischargedL3 DOOR EMERGENCY LIGHT BATTERY CAPACITY LOW. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018071001576Pressure Deck · crackedSTA 1287 LBL 18.3-25.7 HORIZONTAL PRESSURE DECK FOUND 2EA CRACKS APPROX 3" & 2.5" IN LENGTH. STA1287 HORIZONTAL PRESSURE DECK WEB LBL18.3-LBL25.7 REPLACED AS PER EA5300-01502 OP002. PRESSURE DECK WEB REPAIRED AS PER EA5300-01502 OP002.SDR CALA2018071001575Structure · crackedFUSELAGE BS 2370 LT PIVOT BULKHEAD FORWARD CHORD O/B SURFACE FOUND CRACKED, ACCOMPLISH EA5380-01113 OP011. FUSELAGE BS 2370 LT PIVOT BULKHEAD FWD CHORD REPAIRED AS PER EA5380-01113 OP011.SDR CALA2018071001579Pressure Deck · crackedSTA 1287 LBL 25.7-33.0 HORIZONTAL PRESSURE DECK FOUND 1EA CRACK APPROX 2" IN LENGTH. HORIZONTAL PRESSURE DECK WEB REPAIRED AS PER EA 5300-01502 OP002.SDR CALA2018071001578Pressure Deck · crackedSTA 1287 LBL 11.0-18.3 HORIZONTAL PRESSURE DECK FOUND 1EA CRACK APPROX 1.375" IN LENGTH. HORIZONTAL PRESSURE DECK WEB REPAIRED AS PER EA5300-01502 OP002.SDR CALA2018071001577Pressure Deck · crackedSTA 1287 RBL 183-25.7 HORIZONTAL PRESSURE DECK FOUND 1EA CRACK APPROX 3" IN LENGTH. HORIZONTAL PRESSURE DECK WEB REPAIRED AS PER EA5300-01502 OP002.SDR CALA2018070301561Bulkhead · crackedAD2016-09-01 EA 5380-01113 FUSE BS 2370 RT PIVOT BULKHEAD FORWARD CHORD O/B SURFACE FOUND CRACKED ACCOMPLISH EA5380-01113 OP012. FUSELAGE BS 2370 RT PIVOT BULKHEAD FWD CHORD REPAIRED AS PER EA5380-01113 OP012.SDR CALA2018062501521Charger · no testL3 DOOR EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-00.SDR CALA2018062501520Charger · no testR3 DOOR EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062501524Charger · no testL1 DOOR EMERGENCY LIGHT BATTERY M33424 CAPACITY CHECK FAILED. THE CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062501523Battery · dischargedR3 DOOR EMERGENCY LIGHT BATTERY M33401 CAPACITY WAS LOW. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018062501522Battery · dischargedL1 DOOR EMERGENCY LIGHT BATTERY M33424 CAPACITY FOUND LOW. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2017060501696Sign · looseEMERGENCY EXIT LIGHTS LOOSE EMERGENCY EXIT SIGN MOVING AROUND. L3 DOOR SECURED EMERGENCY EXIT LIGHTS SIGNSDR CALA2017052901634Flashlight Assy · brokenR4 DOOR EMERGENCY FLASHLIGHT HOLDER BROKEN. REPLACED FLASHLIGHT ASSY. OP CHECKED GOOD.SDR CALA2016110295883Skin · crackedSTA 2195.75 STR 7R TO 8R, FUSELAGE SKIN FOUND CRACK AROUND 2EA FASTENER. FUSELAGE SKIN STA 2195.75 STR 7R TO STR 8R REPAIRED AS PER EA 5300-01986 OP 010.SDR CALA2016103195879Skin · damagedBS 2195.75 STRINGERS 5 & 10L SKIN PANEL HAS A WRINKLE CRACK. REPAIRED IAW EA 5300-01986 OP 10.SDR CALA2015062494015Monitor · failedSEAT 20J SWING UP MONITOR FAILED & WAS ARCING & SMOKED. CREW DISABLED IFE SWITCH IN COCKPIT. INSPECTED HARNESS FROM MONITOR TO DISCONNECT POINT UNDER SEAT, COULD NOT FIND ANY INDICATION OF ARCING, HARNESS APPEARS TO BE IN SERVICEABLE CONDITION. MONITOR WOULSDR CALA2015062293999Monitor · failedSEAT 20J SWING UP MONITOR FAILED & WAS ARCING & SMOKED. CREW DISABLED IFE SWITCH IN COCKPIT. INSPECTED HARNESS FROM MONITOR TO DISCONNECT POINT UNDER SEAT, COULD NOT FIND ANY INDICATION OF ARCING, HARNESS APPEARS TO BE IN SERVICEABLE CONDITION. MONITOR WOULSDR CALA2015051393777Skin · damagedBULK CARGO DOOR OUTER SKIN STATION 1895 - 916, STRINGER 33R - 34R FOUND EXISTING BLEND OUT. EXTERIOR SKIN NR 3 BEAM AREA BLEND OUT INTERIM REPAIR ACCOMPLISHED IAW ECRA 5230-01962 REV A PART 1 ITEM 1 & 2. IAW ECRA 5230-01962 REV A PART 1 ITEM 3.SDR CALA2014081891998Unknown · odorFLIGHT ATTENDANT REPORTED OIL, BURNT RUBBER FUMES IN ROWS 36 - 39. TRIM AIR OFF FOR REMAINDER OF FLIGHT DUE TO CABIN FUMES. RAN BOTH ENGS INDIVIDUALLY, RAN BOTH PACKS WITH TRIM AIR VLVS & RECIRCULATING FANS. INSPECTED SEAT ROWS FROM 36 - 39 & WE WERE UNABLESDR CALA2014060291176Converter · faultyFIRST OFFICER`S WINDSHIELD WIPER ONLY SWIPES 1/4 OF WINDOW. R & R FIRST OFFICER`S WINDSHIELD WIPER MOTOR CONVERTER IAW AMM 30-42-03, OPERATIONS CHECKED GOOD. ACFT UPGRADE NOW TO FULL CAT CAPABILITY.SDR CALA2014012090180Handle · frozenDOOR 1L WON’T CLOSE FROM THE EXTERIOR. OK FROM THE INTERIOR HANDLE. FOUND HANDLE FROZEN, APPLIED HEAT, OPERATIONS CHECKED GOOD.SDR CALA2014010790052Warning System · activatedEQUIPMENT COOLING EICAS ADVISORY DISPLAYED, MAT MX MESSAGE 21-14132 FOR F D FLOW SENSOR BEING REPORTED.
Back to N778UA