N78002
Service difficulty reports · 84
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N78002' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N78002' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026091519445Floorbeam · corrodedM/D STA 246 AFT FACE FLR SUPPORT MID CHORD FOUND CORROSION AT RBL 60. RAISED FROM WORK CARD 85-5305-1-0012. M/D STA246 FLOORBEAM AFT FACE MID SUP PORT CHORD REPAIRED AS PER ECRA 5310-09057 REV -. PERFORMED MID CHORD REPAIR PER ECRA 5310-09057.SDR CALA2026090919342Battery Pack · dischargedTHE FWD EMERGENCY LIGHT POWER SUPPLY BATTERY PACK (M33232) AT THE DOOR 4R FOUND LOW CAPACITY. REPLACED DOOR 4R FWD EMERGENCY POWER SUPPLY BATTERY AND OPERATION TEST OK, REF TO AMM 33-51-00-710-801 REV 107.SDR CALA2026070717601Light · missingEMERGENCY PATH LIGHTING UNDER SEAT 42D INOPERATIVE. EPL UNDER SEAT 42D MISSING CONFIRMED ISSUE, EPL UNDER SEAT 42D MISSING, REMOVED AND REPLACED EPL EMERGENCY PATH LIGHT SEAT 42D. PERFORMED OPS CHECK IAW AMM 33-51-05. OPS CHECK NORMAL AT THIS TIME. OK FOR SERSDR CALA2026051816333Exhaust Cone · damagedUPON ARRIVAL, DURING WALKAROUND ON ENGINE #1 A DENT WAS FOUND IN THE TURBINE NOZZLE EXHAUST AT 6 O CLOCK POSITION. PICS ATTACHED 17 INCH LONG INNER CRACK, 0,02 INCH (0,05 MM) WIDTH. ITEM 5 TURBINE PRIMARY EXHAUST NOZZLE ENGINE #1 REPLACED IAW AMM 78-11-01-400SDR CALA2026043015857Battery Pack · faultedEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE, PACK BATTERY INOP, POS M32401, M33401. BATTERY PACKS REPLACED ON POS M32401 AND 33401. IAW AMM 33-51-06-960-802. FUNTIONAL TEST PASSED.SDR CALA2026031914678Oven · faultedOVEN IN FWD GALLEY HAS STRONG FUMES AND EMITS ABNORMAL NOISE OVEN 203 IN FWD GALLEY MAKING EXTREMELY LOUD NOISE. TRIED RESETTING, NO HELP. R & R STEAM OVEN IN STATION 203 IN FWD GALLEY REF AMM 25-32-02 OPS CHECKED GOOD.SDR CALA2026020613616Not Reported · not reportedREJECTED TAKEOFF AT 50 KTS, CREW REPORTED REJECTED TAKE OFF AT LOW SPEED. NO HIGH ENERGY STOP CONDITIONS OBSERVED. OK FOR SERVICE IAW AMM 05-51-14-210-801.SDR CALA2026012613316Bustle · damagedSLIDE COVER AT DOOR 3R HAS A HOLE IN THE TOP RIGHT CORNER AREA OF COVER OF ESCAPE SLIDE. ECRA 2560-03761 PART 1 PERFORMED SATISFACTORY. PART 2 INSPECTION REQUIRED EACH FC. PART 3 PERMANENT REPAIR REQUIRED IN 2 FC INTERIM REPAIR PART1 PER ECRA 2560-03761 ACCOMSDR CALA2026010912852Anti-Ice Valve · failedANTI ICE ENG L EICAS, LT ENG ANTI ICE VALVE DEACTIVATED IN OPEN POSITION WITH KIT WAITING FOR DEFERRAL. APPROVES MEL 3021T LT EAI VALVE DEACTIVATED OPEN WITH KIT DEFERRED EAI VALVE DEACTIVATED IN OPEN POSITION IAW AMM 30-00-00-040-809-001.SDR CALA2025121612173Battery Pack · no testDURING OHAR EMERGENCY LIGHT TEST, LIGHTS DO NOT TURN ON. BATTERY PACK REPLACED IAW TASK 33-51-15-800-801-C5. TEST PERFORMED OK IAW TASK 33-51-15-800-801-C3.SDR CALA2025071106474Hose · leakingHYDRAULIC FLUID LEAKING OUT OF HYDRAULIC LINE IN NLG AREA. FOUND INBOARD HYDRAULIC HOSE DAMAGED BEHIND LEFT NOSE LANDING LIGHT. REF PHOTO FOR LINE LOCATION. HOSE PART # AS115-10K0460. REF IPC 32-51-80-05, FIG ITEM 40. SUSPECT HYDRAULIC LEAKING OUT OF RIGID LSDR CALA2025060405272Smoke Detector · false activation4L LAV SMOKE DETCTOR WENT OFF THEN STOPPED NO SMOKE APPLY MEL 2613F THE ZMU WAS REPLACED, THE SMOKE DETECTOR TESTED GOOD AND NO FAULTS REPORTED ON THE CACP ALL TEST. REF LOG #5063824SDR CALA2025032103067Battery · dischargedEMERGENCY POWER ASSIST SYSTEM (EPAS) 9 VOLT BACK-UP BATTERY INSTALLATION BACKUP 9-VOLT BATTERY INSTALLATION - FOUND RED WIRE BROKEN DURING EPAS OPERATIONAL CHECK. AMBER LIGHT WILL NOT ILLUMINATE. REPLACED SPLICE CONNECTION REF AMM 20-30-12 PG 546.SDR CALA2025031702887Light · detachedEMERGENCY LIGHT AT 37G HANGING OFF SEAT RELATED EMERGENCY LIGHT REPOSITIONED IAW AMM 33-51-00 REV. 103SDR CALA2025010200014Smoke Warning · false activationMOMENTARY SMOKE LAV EICAS. CHECKED ALL LAVS NO SIGN OF SMOKE PERFORMED CSS ALL TEST THEN, NO FOUND ISSUE WITH LAV SMOKE DETECTOR. CHECKED ALL LAVATORY NO TRACE OF SMOKE. REF AMM:26-13-00-710-801SDR CALA2024111401134Snubber · faultyOIL DRIP ABOVE 2L SLIDE PACK REMOVED AND REPLACED 2L DOOR SNUBBER, REF M.M. 52-11-08, OPS CHK NORMAL.PARTS USED: 26-5211-9-9001, QTY :1.ROTABLE PARTS CHANGE WAS INDICATED - TT # 1066184 SN OFF 1464.SNUBBER, MAIN E OFF 26-5211-9-9001 1464 ON 26-5211-9-9001 138SDR CALA2024051301440Battery Pack · no testDOOR 4 RIGHT AFT EMERGENCY POWER SUPPLY UNIT (M33409) FAILED OPE RATIONAL TEST. REQUIRED TO REPLACE BATTERY PACK. DOOR 4 RIGHT AFT EMERGENCY POWER SUPPLY BATTERY PACK REPLACEMENT CARRIED OUT AS PER AMM33-51-06 REV 100 DATED 05 JAN 2024.INSTALLATION TEST CARRIESDR CALA2024051301439Battery Pack · no testDR 1LH FWD (M33093) EMERGENCY LIGHT BATTERY PACK FAIL TEST. REQU IRED TO REPLACE BATTERY PACK. DR 1LH FWD (M33093) EMERGENCY LIGHT BATTERY PACK REPLACED AS PE AMM33-51-06 REV 10 DATED 05 JAN 2024. INSTALLATION TEST CARRIE OUT AS PER AMM33-51-06 REV 100 DATED 0SDR CALA2024051301438Battery Pack · no testDR 1LH AFT (M33424) EMERGENCY LIGHT BATTERY PACK FAIL TEST. REQU IRED TO REPLACE BATTERY PACK. DR 1LH AFT (M33424) EMERGENCY LIGHT BATTERY PACK REPLACED AS PE AMM33-51-06 REV 10 DATED 05 JAN 2024. INSTALLATION TEST CARRIE OUT AS PER AMM33-51-06 REV 100 DATED 0SDR CALA2024051301437Battery Pack · no testDR 2RH FWD (M33097) EMERGENCY LIGHT BATTERY PACK FAIL TEST. REQU IRED TO REPLACE BATTERY PACK. DR 2RH FWD (M33097) EMERGENCY LIGHT BATTERY PACK REPLACED AS PER AMM33-51-06 REV 10 DATED 05 JAN 2024. INSTALLATION TEST CARRIED OUT AS PER AMM33-51-06 REV 100 DATEDSDR CALA2024051301436Battery Pack · no testDR 2RH AFT (M33098) EMERGENCY LIGHT BATTERY PACK FAIL TEST. REQUI RED TO REPLACE BATTERY PACK. DR 2RH (M33098) EMERGENCY LIGHT BATTERY PACK REPLACED AS PER AMM 33-51-06 R100. INSTALLATION TEST AS PER AMM 33-51-06 R100, FOUN D WORKING SATISFACTORY.SDR CALA2024051301430Battery Pack · no testDR 4LH (M33407) EMERGENCY LIGHT BATTERY PACK FAIL TEST. REQUIRED TO REPLACE BATTERY PACK. DR 4LH (M33407) EMERGENCY LIGHT BATTERY PACK REPLACED AS PER AMM 33-15-06 R100. INSTALLATION TEST AS PER AMM 33-51-06 R100, FOUN D WORKING SATISFACTORY.SDR CALA2023080202414Fastener · missingPDA 3 LEFT ENG O/B PYLON PANEL HAS 2 EACH FASTENERS MISSING. SEE PHOTO. ADDED PHOTO. ADDED PHOTO. REINSTALLED 2 EACH SCREWS AS REQUIRED.SDR CALA2023062802053Unknown · inoperativeDUE TO RETURN TO FIELD FOR ALL 3 LAV TANKS SHOWING FULL PLEASE A CP THE FOLLOWING: MAKE SURE THE VACUUM BLOWER CB''S ARE IN P110 Z 1, P210 Z1. ACP BITE CHECK OF ALL 3 LCM''S AMM 38-33-00-501. INSP ECT TANK FOR BROKEN VACUUM OR VENT LINES SEE IPC38-32-07-001 ITSDR CALA2022110203014Structure · crackedSUPPORT TASK - EA 5380-0113 REV B OP 018 - AD 2022-06-07 RH BS 2370 PIVOT FWD CHORD FOUND CRACKS. RH BS2370 PIVOT BULKHEAD FORWARD CHORD MODIFICATION ACCOMPLISHED AS PER EA5380-01113 REV B.SDR CALA2022110203013Structure · crackedSUPPORT TASK - EA 5380-01113 REV B - AD 2022-06-07 OP 17 LH BS2370 PIVOT FWD CHORD FOUND CHORD FOUND CRACKS. LH BS2370 PIVOT BULKHEAD FORWARD CHORD MODIFICATION ACCOMPLISHED AS PER EA5380-01113 REV B.SDR CALA2022110203012Battery Pack · dischargedB777-33-3-7031 - CABIN SEAT 1D-8D FLOOR PROXIMITY LIGHT DIM. CABIN DOOR 2L EMER LIGHT CHARGER AND BATT PACK REPLACED (M33096) AND INSTALLATION TEST RESULT NORMAL AS PER AMM33-51-06.SDR CALA2022103102999Battery · inoperativeB777-33-03-7031 - CABIN SEAT 31ABC TO 37ABC CEILING EMER LIGHT FOUND DIM TRANSFER REF HXWO 1158850 AND ORIGINATED BY EMP V907892 CABIN DOOR 3L EMER LIGHT POWER PACK (M33400) (CHARGER AND BATTERY PACK) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM33-5SDR CALA2022103102998Battery · inoperativeB777-33-03-7031 - CABIN SEAT 40ABC TO 43ABC CEILING EMER LIGHT FOUND DIM TRANSFER REF HXWO 1158841 AND ORIGINATED BY EMP V907892 CABIN DOOR 3L EMER LIGHT CHARGER AND BATT PACK (M33405) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM33-51-06 , WORK ACCOSDR CALA2022103102997Battery · inoperativeB777-33-03-7031 - CABIN SEAT 46LK-52LK CEILING EMER LIGHT FOUND DIM TRANSFER REF HXWO 1158833 AND ORIGINATED BY EMP V907892 CABIN DOOR 4R EMER LIGHT CHARGER AND BATT PACK (M33409) REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHESDR CALA2022103102996Battery · inoperativeB777-33-3-7030 LH #1 DOOR SLIDE LIGHT FOUND DIM ( M33424 ) TEANSFER REF HXWO 1153605 AND ORIGINATED BY EMP V926677 LH NO.1 DOOR EMERGENCY POWER SUPPLY CHARGER ASSY AND BATTERY PACK REPLACED AND OPERATION TEST NORMAL REF AMM33-51-06 WORK ACCOMPLISHED BY MECHANISDR CALA2022072901907None · none*THIS IS A SUPPLEMENTAL REPORT FOR THE SAME CONTROL NUMBER SUBMITTED ON 7/29/22.* ENG L OVER EGT ON T/O ROLL. TAKEOFF REJECTED. FOUND MULTIPLE HPT STAGE 1 BLADES WITH RADIAL TIP CRACKS LONGER THAN 0.500 INCHES. REMOVED AND REPLACED ENGINE #1. OPS CHECKS AND LSDR CALA2021062500947Printer · odorDUE TO CREW REPORT OF ELECTRIC SMELL IN FLIGHT DECK, ACCOMPLISH "SMOKE/ODOR IN FLT DECK/CABIN CONDITIONAL INSPECTION" IAW AMM TASK 05-51-58-800-801-C3 AS REQUIRED. SEND COMPLETED QUESTIONAIRE FORM 46.6020 TO TOMC. LOCKING TO VERIFY SIGNOFF UNLOCKING TO CLEAR ISDR CALA2021041600485Skin · corrodedVACUUM BLOWER EXHAUST VENT PORT AT STA1968 FUSELAGE SKIN FOUND CORROSION. STA1968 FUSELAGE SKIN VACUUM BLOWER EXHAUST VENT PORT CORROSION AREA REPAIRED AS PER SRM 53-70-01 REV 85 AND ECRA 5331-02712 REV -.SDR CALA2021041600483Skin · corrodedVACUUM BLOWER EXHAUST VENT AT ST1968 S-35L-36L FUSELAGE SKIN CORROSION. (AFT VENT). DISCOVERED DURING D-1 CHECK HAECO XMN STA 1968 FUSELAGE SKIN VACUUM BLOWER EXHAUST VENT PORT CORROSION AREA REPAIRED AS PER SRM 53-70-01 REPAIR 1 REV 85 AND ECRA 5331-02712. INSDR CALA2021041600478Skin · corrodedVACUUM BLOWER EXHAUST VENT PORT AT STA1968 FUSELAGE SKIN FOUND CORROSION. STA1968 FUSELAGE SKIN VACUUM BLOWER EXHAUST VENT PORT CORROSION AREA REPAIRED AS PER SRM 53-70-01 REV 85 AND ECRA 5331-02712 REV -.SDR CALA2021041600471Battery Pack · dischargedEMERGENCY POWER SUPPLY L3(M33400)CAPACITY CHECK FOUND LOW REFER HAECO NON-ROUTINE NO.9432209,ORIGINATED BY EMP:V905359,SPEC NO.B 777-33-3-7015. PERFORMED BY EMP:V903529,REPLACED EMERGENCY POWER SUPPLY L3(M334 00) AND C/O OPERATIONAL TEST AS PER AMM 33-51-06-96SDR CALA2021041600472Battery Pack · dischargedOVERHEAD ATTENDANT REST EMERGENCY POWER SUPP;Y FND INOP. REPLACED OVERHEAD ATTENDANT REST EMERGENCY POWER SUPPLY AND C/O OPERATIONAL TEST AS PER AMM 31-51-06-96 0-802 REV.91 THE RESULT FND NORMAL.SDR CALA2021030100244Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK INOP AT R4 AFT POSITION. REPLACED BATTERY PCK AS PER AMM TASK 33-51-06-960-802. OPS CHECKS GOOD.SDR CALA2019081201352Skin · crackedRH BS1035 UNDERW ING LONGERON FITTING AREA, 1EA HOLE FOUND CRACK AT FX SKIN, DETA ILS REFER ATTACHED FIG, REFER NR LP 9131053. FX SKIN STA 993 TO STA 1035 BETWEEN STR 35R TO STR 38R SKIN REPAIRED AS PER EC/RA NR. 5331-02418 REV.SDR CALA2019081201351Longeron Fitting · crackedRH BS1035 UNDERWING LONGERON FITTING AREA, 1EA HOLE CRACK AT FRONT SPAR LOWER CHO RD, DETAILS REFER ATTACHED FIG, REFER NR LP 9131052. BS1035 RH UNDERWING LONGERON FRONT SPAR LOWER CHORD BTN RBL73-93 TO RBL95-93 LOWER CHORD REPAIRED AS PER EC/RA NR.5710-02727 SDR CALA2019081201349Stringer · crackedSUPPORT TASK: AD2017-16-10 EA5310-06900 REV A OP004 R/H BS1035 U NDERWING LONGERON FITTING, THE MOST I/B ALUMINIUM LAYER FOUND CRACK. RT BS 1035 UNDERWING LONGERON REPLACED AS PER EA5310-06900 REVA OP014.SDR CALA2019081091339Charger · inoperativeL3 DOOR EMERGENCY LIGHT POWER SUPPLY M33406 BATTERY HAD CAPACITY LOW. POWER SUPPLY CHARGER AND BATTERY REPLACED. TESTED NORMAL IAW AMM 33-51-06.SDR CALA2019081091338Battery · dischargedL3 DOOR EMERGENCY LIGHT POWER SUPPLY M33400 BATTERY PACK HAD CAPACITY LOW. POWER SUPPLY CHARGER, AND BATTERY REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2019081091337Battery · dischargedL2 DOOR EMERGENCY LIGHT POWER SUPPLY M33096 BATTERY PACK LOW CAPACITY. POWER SUPPLY BATTERY REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2019081091336Charger · inoperativeL3 DOOR EMERGENCY LIGHT POWER SUPPLY M33405 BATTERY PACK CAPACITY LOW. POWER SUPPLY, CHARGER, AND BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2019081091335Charger · inoperativeR3 DOOR EMERGENCY LIGHT POWER SUPPLY M33401 BATTERY PACK CAPACITY LOW. POWER SUPPLY, CHARGER, AND BATTERY REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2019081091334Battery · dischargedR2 DOOR EMERGENCY LIGHT POWER SUPPLY M33097 BATTERY PACK CAPACITY LOW . POWER SUPPLY, CHARGER, AND BATTERY PACK REPLACED AND TESTED IAW AMM 33-51-06.SDR CALA2019072401251Longeron · crackedSUPPORT TASK: AD2017-16-10 EA5310-06900 REV A OP004 RT BS1035 UNDERWING LONGERON FITTING, THE MOST I/B ALUMINIUM LAYER FOUND CRACK AS MARKED. PLEASE PRINT OP14 FOR REPAIR, REFER NR LP 9130179. R/H BS1035 UNDERWING LONGERON REPLACED AS PER EA5310-06900 REVA OP0SDR CALA2018032300990Switch · inoperativeL3 DOOR FAILED A TEST. TROUBLESHOT THE SYSTEM AND FOUND THE SWITCH S52125 HAD NO CONTINUITY. REMOVED AND REPLACED IAW AMM 52-11-28-000-802. CHECKED GOOD.
Back to N78002