N796AN
Service difficulty reports · 204
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N796AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N796AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20160916003Battery Pack · dischargedDURING PS2 EMERGENCY LIGHT OPERATIONAL TEST EMERGENCY LIGHTS DOOR 1L TURNED OFF AFTER 30SEC. ACCOMPLISHED TROUBLESHOOTING SSM 33-51-12 AND REPLACED POWER SUPPLY BATTERY M33093 LOCATED ABOVE 1L DOOR IAW AMM 33-51-06. CHECK OPERATIONAL OK AFTER MAINTENANCE PROCESDR AALA20160523006Fan · faultyAIRCRAFT WAS GNDED. DURING CRUISE, FLIGHT ATTENDANTS REPORTED A STRONG ELEC ODOR. POWER PORTS & RECIRCULATION FANS WERE TURNED OFF & ODOR DISSIPATED RAPIDLY. FOUND THE RT LOWER RECIRCULATION FAN SEIZED & ASSOCIATED CBS TRIPPED. ALSO FOUND AFT UPPER RECIRCULSDR AALA20160523005Fan · faultyAIRCRAFT WAS GNDED. DURING CRUISE, FLIGHT ATTENDANTS REPORTED A STRONG ELEC ODOR. POWER PORTS & RECIRCULATION FANS WERE TURNED OFF & ODOR DISSIPATED RAPIDLY. FOUND THE RT LOWER RECIRCULATION FAN SEIZED & ASSOCIATED CBS TRIPPED. ALSO FOUND AFT UPPER RECIRCULSDR AALA20160523004Fan · seizedAIRCRAFT WAS GNDED. DURING CRUISE, FLIGHT ATTENDANTS REPORTED A STRONG ELEC ODOR. POWER PORTS & RECIRCULATION FANS WERE TURNED OFF & ODOR DISSIPATED RAPIDLY. FOUND THE RT LOWER RECIRCULATION FAN SEIZED & ASSOCIATED CB`S TRIPPED. ALSO FOUND AFT UPPER RECIRCUSDR AALA20151002003Connector · detectedFOUND SEAT & FLOOR EMER LIGHTS AT ROWS 12 & 13 BOTH SIDES INOPERATIVE. RE-ATTACHED ONE CONNECTOR AT ROW 12 & ONE CONNECTOR AT ROW 13. SEAT & FLOOR EMER LIGHTS AT ROWS 12 & 13 BACK TO WORK NORMALLY. OPERATIONS TESTED IAW AMM 33-51-00.SDR AALA20150919002Lens · detachedAFT PARTITION CTR EMER LIGHT LENS DETACHED. AFT PARTITION CTR EMER LIGHT ASSEMBLY REPLACED & TESTED NORMAL IAW AMM 33-51-05.SDR AALA20150918010Sign · damagedRIGHT NR 2 DOOR FWD & AFT EXIT SIGN BASE, TWO EACH FOUND DAMAGED. REPLACED & INSTALLATION TEST FOUND NORMAL IAW AMM 33-51-01.SDR AALA20150918002Sign · damagedRIGHT NR 3 DOOR FWD EXIT SIGN BASE FOUND DAMAGED. RT NR 3 FWD EXIT SIGN BASE REPLACED & INSTALLATION TEST FOUND NORMAL IAW AMM 33-51-01.SDR AALA20150917021Sign · damagedLEFT NR 2 DOOR AFT EXIT SIGN BASE FOUND DAMAGED. LT NR 2 DOOR AFT EXIT SIGN BASE REPLACED & INSTALLATION TEST FOUND NORMAL IAW AMM 33-51-01.SDR AALA20150917020Battery · dischargedEMERGENCY POWER BATTERY M33098 FOUND INOPERATIVE. EMER POWER BATTERY M33098 REPLACED & TESTED NORMAL IAW AMM 33-51-06.SDR AALA20150917019Battery · dischargedEMERGENCY POWER BATTERY M33096 FOUND INOPERATIVE. EMER POWER BATTERY M33096 REPLACED & TESTED NORMAL IAW AMM 33-51-06.SDR AALA20150917018Battery · dischargedEMERGENCY POWER BATTERY M33405 FOUND INOPERATIVE. EMER POWER BATTERY M33405 REPLACED & TESTED NORMAL IAW AMM 33-51-06.SDR AALA20150917016Window · scratchedCOCKPIT R2 SLIDING WINDOW, FOUND SCRATCH MARK & HAND CRANK DIFFICULT TO LATCH, FWD EDGE FOUND CHIPPED. COCKPIT R2 SLIDING WINDOW REPLACED IAW AMM 56-11-02.SDR AALA20150917011Switch · inoperativeMAIN DECK DOOR 3 LT EPAS FUNCTIONAL CHECK FAILED. DOOR 3 LT DOOR OPEN SWITCH & MODE SELECT SWITCH REPLACED. ADJUSTED & TESTED IAW AMM 52-11-28. CARRIED OUT EMER POWER ASSIST SYS TEST & FOUND NORMAL IAW AMM 52-11-20.SDR AALA20150916005Rib · corrodedLEFT WING TE ORSS 1295, OTBD AILERON NR 3 HINGE RIB FOUND CORROSION AT BONDING JUMPER ATTACH POINT AREA. REPAIR CARRIED OUT IAW SRM 57-51-02-2R PROCEDURE 3 REPAIR 3.SDR AALA20150916004Rib · corrodedLEFT WING TE ORSS 1225, OTBD AILERON NR 5 HINGE RIB FOUND CORROSION AT BONDING JUMPER ATTACH POINT AREA. REPAIR CARRIED OUT IAW SRM 57-51-02-2R REPAIR 3.SDR AALA20150916003Rib · corrodedRIGHT WING TE ORSS 1225, OTBD AILERON NR 5 HINGE RIB WEB FOUND CORROSION AT BONDING JUMPER ATTACH POINT AREA. REMOVED IAW SRM 57-51-02-2R. PROCEDURE & REPAIR PARTS INSTALLED IAW SRM 51-57-02 REPAIR 3.SDR AALA20150912006Power Supply · failedLEFT NR 2 DOOR EMER POWER SUPPLY M33099 BATTERY CAPACITY TEST FAILED LESS THAN 10 MINUTES. REPLACED LT NR 2 DOOR EMER POWER SUPPLY M33099. INSTALLATION TEST CARRIED OUT & RESULTS NORMAL IAW AMM 33-51-06.SDR AALA20140714004Trim Panel · brokenTRIM ON ESCAPE PATH LIGHT ASSEMBLY ON LT SIDE MID GALLEY, FIRST CLASS, BROKEN. REPLACED EMER LIGHT. OPERATIONS CHECKED NORMAL.SDR AALA20140714003Trim Panel · brokenTRIM ON ESCAPE PATH LIGHT ASSEMBLY ON RT SIDE MID GALLEY, FIRST CLASS BROKEN. REPLACED EMER LIGHT. OPERATIONS CHECKED NORMAL.SDR AALA20140705001Guard · brokenEMERGENCY LIGHTS SWITCH COVER ON FLIGHT DECK OVERHEAD PANEL BROKEN. NEW SWITCH GUARD REPLACED. OPERATIONS CHECKED NORMAL.SDR AALA20130730008Light · inoperativeSEAT 12D FORWARD EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP FOR SEAT 12D FORWARD EMERGENCY LIGHT. OPERATIONS CHECKED NORMAL.SDR AALA20130730003Connector · looseSEAT 10D EMERGENCY LIGHT INOPERATIVE. SECURED LOOSE CONNECTOR FOR SEAT 10D EMERGENCY LIGHT. OPERATIONS CHECKED NORMAL.SDR AALA20130701004Light · inoperativeESCAPE PATH LIGHT AT SEAT 23C INOPERATIVE. REPLACED LAMP FOR ESCAPE PATH LIGHT AT SEAT 23C. OPERATIONS CHECKED NORMAL.SDR AALA20130629002Battery Pack · dischargedLT AFT COACH EMERGENCY LIGHTS FROM ROWS 30 - 45 FAILED TEST. REPLACED LT AFT BATTERY PACK. OPERATIONS CHECKED NORMALSDR AALA20121120007Light · inoperativeROW 34G ESCAPE PATH LIGHT INOPERATIVE. REPLACED LAMP FOR ROW 34G ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR AALA20121120006Light · inoperativeROW 22G ESCAPE PATH LIGHT INOPERATIVE. REPLACED LAMP FOR ROW 22G ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR AALA20121120005Light · inoperativeROW 38G ESCAPE PATH LIGHT INOPERATIVE. REPLACED LAMP FOR ROW 38G ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR AALA20121120004Light · inoperativeROW 40G ESCAPE PATH LIGHT INOPERATIVE. REPLACED LAMP FOR ROW 40G ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR AALA20121120003Light · inoperativeROW 40C ESCAPE PATH LIGHT INOPERATIVE. REPLACED LAMP FOR ROW 40C ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR AALA20121119011Light · inoperativeROW 22C ESCAPE PATH LIGHT INOPERATIVE. REPLACED LAMP FOR ROW 22C ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR AALA20121022003Oven · inoperativeLHR - CREW REPORTED OVEN 9C OVERHEATED AND SMELLED OF ELECTRICAL ODOR. FLIGHT LANDED LHR WITHOUT INCIDENT. REPLACED OVEN 9C AT DFW ON 10/24/2012. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA20121013001Seat · defectiveLHR - CREW REPORTED ELECTRIC SHORT IN SEAT 4D IS CAUSING ELECTRIC SHOCKS TO PASSENGER. DEACTIVATED SEAT 4D ELECTRICS. HANDSET DISCONNECTED, SEAT POWER AND SEAT CONTROLLER CIRCUIT BREAKER PULLED. REPLACED SEAT 4D. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA20120813006Pump · failedEZE - CREW REPORTED RIGHT ENGINE DRIVEN HYDRAULIC PUMP FAILED WITH FLUID LOSS. EMERGENCY DECLARED FLIGHT LANDED EZE WITHOUT INCIDENT. REPLACED RIGHT ENGINE DRIVEN HYDRAULIC PUMP AND PRESSURE AND CASE DRAIN FILTERS. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA20120607013Lens · missingBUSINESS CLASS GALLEY OVERHEAD ESCAPE PATH LIGHT MISSING LENS. REPLACED LENS FOR BUSINESS CLASS GALLEY OVERHEAD ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR AALA20120426027Light · inoperativeSEAT 26G EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP FOR SEAT 26G EMERGENCY LIGHT. OPS CHECK NORMAL.SDR AALA20120414008Connector · looseEMERGENCY LIGHTS AT SEATS 30 TO 32G INOPERATIVE. SECURED LOOSE CONNECTOR AT SEAT 32. OPS CHECKED NORMAL.SDR AALA20120414007Connector · looseEMERGENCY LIGHTS AT SEATS 30 TO 32C INOPERATIVE. SECURED LOOSE CONNECTOR BENEATH SEAT 32. OPS CHECK NORMAL.SDR AALA20120321015Unknown · odorLHR - CREW REPORTED ON DESCENT A STRONG ELECTRICAL BURNING SMELL STARTING AROUND ROWS 30 TO 40. FLIGHT LANDED LHR WITHOUT INCIDENT. REPLACED AVU AT SEAT 33CD AS A PRECAUTION. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA20110823MIA01Outflow Valve · openMIA - CREW REPORTED AIRCRAFT UNABLE TO PRESSURIZE AFTER TAKEOFF. AFT OUTFLOW VALVE SHOWED FULLY CLOSED. EMERGENCY DECLARED FLIGHT RETURNED MIA LANDED WITHOUT INCIDENT. FOUND AFT OUTFLOW VALVE FULLY OPEN. AFT OUTFLOW WAS ON PLACARD. REPOSITIONED VALVE TO SSDR AALA20101022TUL05Lens · missingFORWARD GALLEY FRONT ESCAPE PATH LIGHT HAS LENS MISSING. REPLACED LENS FOR FORWARD GALLEY FRONT ESCAPE PATH LIGHT. OPS CHECKS NORMAL.SDR AALA20101022TUL04Light · inoperativeLEFT NUMBER 3 DOOR RIGHT SIDEWALL ESCAPE PATH LIGHT LAMP INOPERATIVE. REPLACED LAMP FOR LEFT NUMBER 3 DOOR SIDEWALL ESCAPE PATH LIGHT. OPS CHECKS NORMAL.SDR AALA20101022DFW02Light · inoperativeROW 39C ESCAPE PATH LIGHT LAMP INOPERATIVE. REPLACED LAMP FOR ROW 39C ESCAPE PATH LIGHT. OPS CHECKS NORMAL.SDR AALA20101022DFW01Light · inoperativeROW 26C ESCAPE PATH LIGHT HAS ONE LAMP INOPERATIVE. REPLACED LAMP FOR ROW 26C ESCAPE PATH LIGHT. OPS CHECKS NORMAL.SDR AALA20100704DFW02Light · inoperativeROW 31 CENTER ESCAPE PATH LIGHT INOPERATIVE BOTH SIDES. REPLACED LAMP FOR BOTH ESCAPE PATH LIGHT FIXTURES ON CENTER ROW. ALL CHECKS NORMAL.SDR AALA20100704DFW04Lens · missingROW 41G ESCAPE PATH LIGHT MISSING LENS. REPLACED LENS FOR ESCAPE PATH LIGHT AT 41G. OPS CHECKED NORMAL.SDR AALA20100704DFW03Lens · missingROW 45 CENTER ESCAPE PATH LIGHT MISSING LENS. REPLACED LENS FOR RPW 45 CENTER ESCAPE PATH LIGHT. OPS CHECKED NORMAL.SDR AALA20100624MIA03Light · inoperativeMID GALLEY EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY FOR MID GALLEY EMERGENCY EXIT LIGHT. OPS CHECKED NORMAL.SDR AALA20100624MIA02Light · inoperativeROW 34 EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT ROW 34. OPS CHECKED NORMAL.SDR AALA20100624MIA01Light · inoperativeROW 13 EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LAMP FOR ROW 13 EMERGENCY EXIT LIGHT. OPS CHECKED NORMAL.