N802TJ

Service difficulty reports · 40

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N802TJ' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 4TXA2026050700323Control Module · intermittentINTERMITTENT WARNING HORN CABIN ALTITUDE LIGHT ILLUMINATED FL 270 CAB ALTITUDE SHOWING 11000 FT. FOLLOWED QRH AND LANDED THE AIRCRAFT IN MUCU SAFELY. EMERGENCY DECLARED.May 7, 2026 · N802TJ · Boeing 7374B7 · Cabin Pressure Control SystemSDR 4TXA2026050700324Control Module · intermittentINTERMITTENT WARNING HORN CABIN ALTITUDE LIGHT ILLUMINATED FL 270 CAB ALTITUDE SHOWING 11000 FT. FOLLOWED QRH AND LANDED THE AIRCRAFT IN MUCU SAFELY. EMERGENCY DECLARED.Apr 19, 2026 · N802TJ · Boeing 7374B7 · Air Conditioning SystemSDR I5EA2023110200003Power Supply · no testPOWER SUPPLY AT M1479 REQUIRES REPLACEMENT. REMOVE AND REPLACED WITH SERVICEABLE POWER SUPPLY AT STA. 598R, M1479. OPS CHECK GOOD IAW B737-400 AMM 33-51-51.Nov 2, 2023 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2023110200002Battery Pack · no testEMERGENCY LIGHT INOP OVERWING HATCH L/H AFT. REMOVE AND REPLACED BATTERY PACK AT STA. 598R, MODULE M1479. OPS CHECK GOOD IAW B737-400 AMM 33-51-51.Nov 2, 2023 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2023071200002Battery Pack · no testMID CABIN EMERGENCY LIGHTS ARE INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK M1134 AT STA> 629 WITH SERVICEABLE UNIT AND TEST IAW B737-400 AMM 33-51-51. TEST GOOD.Jul 12, 2023 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2023070200001Skin · dentedDENT FUSELAGE SECTION 46 UPPER PLATING BS 993 STR 15LHJul 2, 2023 · N802TJ · Boeing 7374B7 · Fuselage Main, Plate/SkinSDR I5EA2022100700005Charger · no testFOUND EMERGENCY LIGHT BATTERY CHARGER INOP AT L/H OWEE. REMOVED AND REPLACED EMR BATTERY CHARGER M1134 STA 634L IAW B737-400 AMM 33-51-51. TEST OK.Oct 7, 2022 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2022100700004Battery Pack · no testEMERGENCY EXIT LIGHT AT R/H OWEE INOP. REMOVED AND REPLACED M1479 EMR LIGHT BATTERY AT STA 598R IAW B737-400 AMM 33-51-51. TEST OK.Oct 7, 2022 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2022100700003Battery Pack · no testEMERGENCY EXIT LIGHT AT L/H OWEE INOP. REMOVED AND REPLACED M1134 EMR BATTERY PACK STA 634L IAW B737-400 AMM 33-51-51. TEST GOOD.Oct 7, 2022 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2022100700002Battery Pack · no testEMERGENCY EXIT LIGHT AT L-2 DOOR INOP. REMOVED AND REPLACED M1133 BATTERY EMR ESCAPE STA 326R IAW B737-400 AMM 33-51-51. TEST GOOD.Oct 7, 2022 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2021111500003Battery Pack · dischargedEMERGENCY LIGHT AT L1 DOOR INOPERATIVE. REMOVED AND REPLACED M1133 EMERGENCY LIGHT BATTERY AT STA. 330L, IAW B737 AMM 33-51-51, OPS CHECK GOOD.Nov 15, 2021 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2021011900005Battery Pack · no testEMERGENCY LIGHTS INOPERABLE ABOVE L2 AND AT FLOOR LEVEL AROUND R2 DOOR. REMOVED AND REPLACED AFT RT BATTERY PACK. OPERATIONS CHECK NORMAL, IAW B737-400 AMM 33-51-51, NO DEFECTS NOTED.Jan 19, 2021 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2021010600003Battery Pack · no testEMERGENCY LIGHT INOPERABLE ROW 9 LEFT. REMOVED AND REPLACED EMERGENCY LIGHT PACK AT STA 629L AND TEST, IAW B-737-400 AMM 33-51-51. OPERATIONS CHECK GOOD.Jan 6, 2021 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2020110100004Battery Pack · dischargedPOWER SUPPLY BATTERY LOCATED IN AFT GALLEY LT IS INOPERABLE. PERFORMED REMOVAL AND REPLACEMENT POWER SUPPLY BATTERY IN AFT GALLEY LT, IAW AMM 33-51-51 AND OPERATIONS CHECK OKAY.Oct 29, 2020 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2020110100003Battery Pack · dischargedPOWER SUPPLY BATTERY IN BIN 22 RT IS INOPERABLE. REMOVE AND REPLACE POWER SUPPLY BATTERY BIN 22 RT, IAW AMM 33-51-51 AND OPERATIONS CHECK OKAY.Oct 29, 2020 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2020110100002Battery Pack · dischargedPOWER SUPPLY BATTERY IN BIN 22 LT IS INOPERABLE. REMOVE AND REPLACE POWER SUPPLY BATTERY BIN 22 LT, IAW AMM 33-51-51 AND OPERATIONS CHECK OKAY.Oct 29, 2020 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2020110100001Battery Pack · dischargedPOWER SUPPLY BATTERY IN BIN 12 LT IS INOPERABLE. REMOVE AND REPLACE POWER SUPPLY BATTERY BIN 12 LT, IAW AMM 33-51-51 AND OPERATIONS CHECK OKAY.Oct 29, 2020 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2019101090003Selector Panel · defectiveNO PRESSURIZATION DURING CLIMB OUT. SUPPLEMENTAL INFORMATION, PERFORMED OPERATIONAL TEST ON PRESSURIZATION SYSTEM, TEST FAILED. REPLACED SELECTOR PANEL, PERFORMED AGAIN OPERATIONAL TEST ON PRESSURIZATION SYSTEM, TEST OK. ALL MAINTENANCE ACTION IAW AMM 21-31Sep 21, 2019 · N802TJ · Boeing 7374B7 · Cabin Pressure Control SystemSDR I5EA2019072508Unknown · odorDISCREPANCY: THE CABIN AND COCKPIT EXPERIENCED A STRONG SMELL WATER HEATER LEFT AFT SIDE , OVERHEATED COFFEE POTS WERE REPORTED OVERHEATING WITH GALLEY POWER SWITCH IN THE OFF POSITION. CORRECTIVE ACTION: INSPECTED PSU ROW 6,7,8 AX WIRING AS PER AMM 20-60-04 Jul 20, 2019 · N802TJ · Boeing 7374B7 · Air Distribution SystemSDR I5EA2019072306Sense Line · looseDISCREPANCY: FL 310 CLIMBING, CABIN BEGAN TO CLIMB UNCONTROLLABLY, RT PACK WENT TO ZERO. CORRECTIVE ACTION: PERFORMED TROUBLE SHOOTING FOUND HEAVY PENUMATIC LEAK ON RIGHT ENGINE UNDER PRE COOLER VALVE. TIGHTEND SCNSING LINE, OPERATIONAL CHECK FOUND NORMAL. Jul 18, 2019 · N802TJ · Boeing 7374B7 · Pneumatic Indicating SystemSDR I5EA2019072507Shutoff Valve · malfunctionedAT FL 310 AND CLIMBING, CABIN PRESSURE UNCONTROLABLE RT PACK 0 PSI. LOCKED OUT RT PRSOV. REMOVED AND REPLACED THE LT PRSOV.Jul 17, 2019 · N802TJ · Boeing 7374B7 · Pneumatic Distribution SystemSDR I5EA201904240005Target · out of adjustDISCREPANCY: RT GEAR RED LIGHT ILLUMINATED WITH GEAR LEVER IN UP POSITION AFTER TAKE OFF. RECYCLED GEAR RED LIGHT ILLUMINATED AGIAN. ADJUSTED THE SENSOR TARGET OF RIGHT MAIN LANDING GEAR UP LOCK SENSOR. PERFORMED OPS CHECK AND TEST IAW AMM 32-61-21, AMM 32-61Apr 22, 2019 · N802TJ · Boeing 737401 · Landing Gear Position and WarningSDR I5EA2018052200001Power Supply · unserviceableEMERGENCY LIGHT OUT AT STA 727D LT. REMOVED AND REPLACE POWER SUPPLY AT STA 753L REF AMM 33-51-51, OPS CHECK GOOD AT THIS TIME.May 17, 2018 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2018040600002Battery Pack · inoperativeRIGHT EMERGENCY HATCH EXIT SIGN LIGHT INOPERATIVE AT BS 627R. REPLACED THE BATTERY PACK.Apr 1, 2018 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2018042000001Battery Pack · dischargedLEFT FLOOR PROXIMITY FWD CENTER EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK ASSY M1479 IAW AMM 33-51-51, OPS CHECKED NORMAL.Apr 1, 2018 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA201711270001Power Supply · inoperativeSEVERAL EMERGENCY LIGHTS OUT IN CABIN. REMOVED AND REPLACED BATTERY POWER SUPPLIES AT STA 960R, S/N 37656, AND STA. 969L, S/N 15962. OPERATIONAL TEST GOOD IAW AMM 33-51-51.Nov 24, 2017 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2017082900002Battery Pack · dischargedEMERGENCY LIGHTS AT ROW 5 ABC AND L1 DOOR EXTERIOR ARE INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACKS. PERFORMED OPS CHECK IAW AMM 33-51-51.Aug 28, 2017 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2014061817Battery Pack · dischargedOVERHEAD BIN BULLNOSE EMERGENCY WHITE LIGHT OVER SEATS 7AB, 9AB & 15AB INOPERATIVE. EXTERIOR LT & RT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R BATTERY PACK LOCATED IN CEILING AT STATIONS 753L & 598R.Jun 18, 2014 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2014060260116Battery · dischargedEMERGENCY LIGHT AT L1 POSITION FAILED TEST DURING SERVICE CHECK WALK AROUND. R & R BATTERY FROM THE BATTERY CHARGING PACK AT THE R1 POSITION IAW MM 31-51-52 201. OPERATIONS CHECKED NORMAL. BATTERY ABS 2013-1A R & R, SN OFF 94113 & SN ON 22917.May 29, 2014 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2014060260115Battery · dischargedEMERGENCY EXIT LIGHTS AT R1 POSITION FAILED DURING SERVICE CHECK WALK AROUND. R & R BATTERY FROM THE BATTERY CHARGING PACK AT R1 POSITION IAW MM 31-51-51/201. OPERATIONS CHECKED NORMAL. BATTERY ABS 2013-1A R & R, SN OFF 97119 & SN ON 22922.May 29, 2014 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA20140514001Battery Pack · dischargedEMERGENCY LIGHT AT L2 POSITION INOPERATIVE. R & R BATTERY PACK PN BPS7-3 IAW AMM 33-51-51. EMERGENCY LIGHT AT R2 POSITION INOPERATIVE. R & R BATTERY PACK PN BPS7-3. LT AFT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. R & R BATTERY PACK PN BPS7-3 IAW AMM 33-May 3, 2014 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2014031000014Socket · contaminatedSEAT 6, RT OVERHEAD EMERGENCY LIGHT INOPERATIVE. CLEANED CONNECTOR OF LAMP ASSY IAW BSWPM 20-11-14 OP-CHECK OF EMERGENCY LIGHTS IAW AMM 33-51-12, NO DEFECTS NOTED.Mar 7, 2014 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA201403100011Socket · contaminatedRIGHT OVERWING EMERGENCY EXIT LIGHT LOWER FWD INOPERATIVE. CLEANED CONTACT OF LAMP ASSY IAW BSWPM 20-10-04.Mar 7, 2014 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA20131124009Feeder Cable · burnedACFT HAD EVIDENCE OF LIGHTNING STRIKE ON RADOME AND REPLACED. ACFT RECEIVED A LIGHTNING STRIKE INSPECTION IAW AMM 05-51-27. DURING TROUBLESHOOTING NR 1 FEEDER CABLE WAS FOUND BURNED AND WAS REPLACED RESTORING FULL ELECTRICAL FUNCTION.Nov 22, 2013 · N802TJ · Boeing 7374B7 · Electrical Power System WiringSDR I5EA201311070008Battery Pack · dischargedEMERGENCY LIGHTS ON OVERHEAD BIN AT SEATS 18L, 14R, 11L, 10R 6R, INOPERATIVE. FOUND 14R BULB BURNED OUT, AND REPLACED BATTERY PACK AT BS 727 IAW AMM 33-51-51.Sep 2, 2013 · N802TJ · Boeing 7374B7 · Emergency LightingSDR I5EA2013101800001Ground Wire · disconnectedEMERGENCY LIGHT AT SEAT 17A INOPERATIVE. TERMINATED GROUND WIRE SWPM 20-30-11, OPS CHECKED GOOD.May 5, 2013 · N802TJ · Boeing 7374B7 · Light System WiringSDR I5EA2012F00190Slide · no testDURING C CHECK AN ATTEMPT TO ACCOMPLISH SWIFT AIR ROUTINE OPS CHECK OF ESCAPE SLIDE SYS, THE L2 DOOR WAS SELECTED FOR DEPLOYMENT. WITH THE SLIDE IN PLACE AND THE GIRT BAR INSTALLED, THE DOOR WAS OPENED BUT THE SLIDE FAILED TO INFLATE. UPON INVESTIGATION OF THEOct 4, 2012 · N802TJ · Boeing 7374B7 · Escape SlideSDR 2012FA0000601Pin · misinstalledDURING C-CHECK, AN ATTEMPT TO OPS CHECK L2 DOOR ESCAPE SLIDE SYS, WITH THE SLIDE PLACE AND THE GIRT BAR INSTALLED THE DOOR WAS OPENED BUT THE SLIDE FAILED TO INFLATE. UPON INVESTIGATION OF THE SLIDE IT WAS FOUND TO HAVE THE SAFETY PIN STILL INSTALLED, AFTEAug 14, 2012 · N802TJ · Boeing 7374B7 · Escape SlideSDR I5EA2012013102Frame · damagedWHILE PERFORMING INITIAL INSPECTION REQUIREMENTS OF AD 2011-23-05 FRAME LOCATION BS 500E BETWEEN S21L AND S20L AT THE 1.04-INCH DIAMETER WIRE CABLE HOLE. ACCOMPLISHED REPAIR PER AD INSTRUCTIONS, BOEING SB 737-53A1279 PART 3 AND 737-400 SRM 53-00-07 REPAIR 13.Jan 31, 2012 · N802TJ · Boeing 7374B7 · Fuselage Main, FrameSDR I5EA20110501Coffeemaker · odorCREW REPORTED FUMES FROM FORWARD GALLEY.May 9, 2011 · N802TJ · Boeing 7374B7 · Buffet/Galleys
Back to N802TJ