N810UA
Service difficulty reports · 146
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N810UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N810UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011121906975Unknown · malfunctionedELAC2, MSG RETURNED, WILL SWAP ELAC1 AND ELAC2 THEN DF ELAC1.SDR UALA2011110105907Battery Pack · dischargedEPSU BATTERY FWD L DISPLAYED AFTER ACCOMPLISHING CABIN EMERGENCY LIGHT TEST. EPSU BATTERY AT FWD DOOR 1L CYCLE CHARGED , ACP SYSTEM TEST. PASSED TEST, OPS CHECKED OKAY.SDR UALA2011083104693Computer · faultyGRIPES ON SLAT SYS 2, WITH RESET OF SFCC2 SLAT CHANNEL CB CORRECTING THE PROBLEM. REPLACE THE SLAT FLAP CONTROL COMPUTER 2 IAW AMM. REPLACED PER LM CALL OUT & ACCOMPLISHED OPERATIONAL TEST OF FLAP AND SLAT SYSTEM, ALL TESTS PASS.SDR UALA2011082604574Display · faultyECAM DISPLAY INOP. -HAS HISTORY- GOES BLURRY INTERMITTENTLY. REPLACE OR SWAP AND DEFER DISPLAY UNIT. INSTALLED NEW UPPER ECAM DISPLAY UNIT PER MM, OPS CHECKS GOOD.SDR UALA2011071903685Apu · faultyEXCESSIVE SMOKE FROM APU EXHAUST AFTER ENGINE START. COMPLIED WITH MEL. APU INOP. CHK'D APU COMPARTMENT AND TAILPIPE FOR OIL WETTING, LEAKS, OR EVIDENCE OF BURNING, NONE FOUND. ATTEMPTED TWO STARTS AT GATE ON TURN: HUNG AT 27-29% N, TEMP 770-800 DEG BOTH TSDR UALA2011071503608Oxygen Mask · failedF/O'S OXYGEN HARNESS FAILS TO INFLATE (LEAKING). MASK FAILED TO INFLATE DURING TEST. SWAPPED F/O O2 MASK WITH 1ST OBS SEAT REF AMM. F/O O2 MASK HARNESS INFLATES NORMALLY. 1ST OBS MASK INOPERATIVE.SDR UALA2011062703131Valve · faultedENG 1 FUEL HEAT SYS DISPLAYED IN UPPER ECAM ON TAXI OUT. POST FLIGHT REPORTS FAULTS FUEL DIVERTER RETURN VALVE.SDR UALA2010120104411Control Unit · malfunctionedLGCIU 1 FAULT, FLIGHT DIVERTED. GEAR EXT AND NR 1 REVERSER OPS NORMAL. LGCIU 1 INDICATION AMBER ON ECAM WHEEL PAGE. FOUND "L-G LGCIU 1 FAULT" ECAM AND "LGCIU1" FAILURE MESSAGES ON PFR. ACCOMPLISHED TSM 32-31-00-810-872. FOUND TROUBLE SHOOT DATA CODE H138.SDR UALA2010101103759Engine · failedSMOKE COMING OUT OF TOP AND BOTTOM OF ENG 2 DURING TAXI. CHRONIC OIL IN TAILPIPE, REPLACED ENGINE. NO FAULTS NOTED AFTER ENG RUN.SDR UALA2010100803739Oxygen Mask · brokenF/O OXYGEN MASK BROKEN. REPLACED DEFECTIVE F/O O2 MASK, OPS CHECKED NORMAL.SDR UALA2010070202354Battery · failedEMERGENCY LIGHTS TEST FAILED WITH MESSAGE 'EPSU INT LOADS AFT LEFT. REPLACED EPSU BATTERY AT AFT POSITION. EMER LIGHTS TEST AT PTC PANEL OKAY.SDR UALA2009090402783Battery · failedCABIN EMERGENCY LIGHTS FAIL 3 SVC CHECK FOR AFT LEFT BATTERY. REPLACED AFT LEFT EMERGENCY LIGHT BATTERY, OP CHECKED OKAY.SDR UALA2009080602370Warning System · activatedCREW REPORTS AEVC FAULT. RTFL. RESET VENT EXTRACT FAULT AND ACCOMPLISHED SYS REPORT TEST, ALL FAULTS CLEARED. NO RECURRENCES. NO ACTION NECESSARY.SDR UALA2009031000731Warning System · activatedDC ESS BUSS SHED ECAM MSG. RTFL (TWICE).SDR 2008UALA04293Power Supply · failedEMERGENCY LIGHTS TEST FAILED WITH EPSU L MESSAGE. FOUND FAULTY POWER SUPPLY. REPLACED LIGHT LENS ASSEMBLIES & LEFT EPSU UNDER LEFT OVERWING EMERGENCY EXIT.
SDR 2008UALA03883Contactor · shortedELECTRICAL PROBLEMS AFTER TAKEOFF. RTFL. ON CLIMBOUT ECAM DC ESS SHED DISPLAYED FOLLOWED BY ECAM CB LFT ELECT BAY. LOSS OF FAC1, FMGC1, AP1, NAVGPWS. DC SHED ESS BUSS CONTACTOR SHORTED. REPLACED CNTOR DC SHED ESS BUS, OPS CHECKED NORMAL.SDR 2008UALA03594Unknown · odorFUMES SMELLED IN CABIN & COCKPIT. RTFL. OIL IN RECIRC PATH ACCOMPLISH PACK BURN OUTS AND CHANGED FILTERS (RECIR) CHECK OF GENERATOR FEEDER PINS ALSO REPLACED FILTERS RECIRC. CHECKED CABIN INTERCOM. RUN CREW REPORTED THE ODOR CAME FROM VENTS UNTILL PACK BURSDR 2008UALA03591Oxygen System · reads lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. *S/D* SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA03372Floor Panel · corrodedAFT RIGHT FLOOR PANEL (TRIANGULAR) 262CF HAS CORROSION PITS AND MISSING METAL.SDR 2008UALA03271Floorbeam · damagedFLOORBEAM 175 NEEDS REPLACEMENT FROM FR68 TO FR70.SDR 2008UALA03270Sill · corrodedDOOR 2R SILL PAN NEEDS TO BE REPLACED DUE TO CORROSION.SDR 2008UALA03274Floorbeam · corrodedFLOORBEAM 150 REMOVED FROM FR65 TO FR70, FOR CORROSION.SDR 2008UALA03273Floorbeam · corrodedFLOORBEAMS 145 AND 140 REMOVED FROM FR 64 TO 69 FOR CORROSION.SDR 2008UALA02634Pin · shearedLEFT OVERWING EXIT NOT ARMED. FOUND ROLL PIN HOLDING DISARM PIN SHEARED. REPLACED PIN AND REPLACED DOOR.
SDR 2008UALA00389Drain Mast · shortedAFTER T/O CABIN CREW IN AFT GALLEY SMELLED ELEC BURN SMELL. AFT GALLEY ODOR DISSIPATED IN A COUPLE MINUTES. NOTICED AFT GALLEY DRAIN C/B POPPED OVERHEAD PNL. GALLEY DRAIN MAST SHORTED. REPLACED GALLEY DRAIN MAST, OPS CHECKED NORMAL.SDR 2007UALA01745Battery Pack · faultyEMERGENCY EXIT LIGHT SYS TEST FAILED, FAULTED AFT LT BATTERY PACK. BATTERY PACK SYS TEST OK.SDR 2007UALA00945Power Supply · failedEMERGENCY LIGHTS EPSU POWER SUPPLY FAILS TEST. REPLACED EPSU POWER SUPPLY UNIT.SDR 2007UALA00944Battery · no testEMERGENCY LIGHTS BATTERIES DUE CAPACITY TEST. [SUP 4-17-07] REPLACED EPSU BATTERIES.SDR 2007UALA00092Power Supply · dischargedEMERGENCY LIGHT TEST ON PTP PANEL, SHOWS EPSU R UNIT. REPLACED EPSU AT RIGHT OVERWING.SDR 2006UALA02248Motor · malfunctionedFORWARD LAV TOILET FLUSH MOTOR RUNS CONTINUOUSLY. REPLACED TOILET ASSEMBLY IN FORWARD LAV. FLUSHES NORMALLY.SDR 2006UALA01579Power Supply · faultyEPSU COMM FWD LEFT MESSAGE ON PTP. REPLACED EMERGENCY POWER SUPPLY UNIT FWD. TESTS OK.SDR 2006UALA01236Buss · malfunctionedDC ESS BUS SHED AFTER TAKEOFF. ACCOMPLISHED TASK 24-60-00-810-810. FOUND CIRCUIT BREAKER 1PH POPPED ON 106VU PANEL. REPLACED CONTACTOR 8PH PER AMM 24-62-55. ALL GROUND CHECKS GOOD. ALL MESSAGES CLEAREDSDR 2006UALA00969Buss · malfunctionedDC ESSENTIAL BUS SHED AFTER TAKEOFF.SDR 2006UALA00474Battery · no testTHE EMERGENCY LIGHT SYS TEST ON PROGRAMMING AND TEST PANEL FAILS, INDICATING -EPSU BATT AFT L- FAULT. REPLACED BATTERY AT POSITION 13WL. TESTS GOOD.SDR 2005UALA00671Epsu · failed"INTERNAL LOAD FAULT FWD L" DISPLAYED ON PTP DURING EMER LIGHT SYS TEST. SWAPPED FWD AND AFT EPSU'S AND ALL TESTED OK. INTERNAL LOAD FAULTS WILL APPEAR IF THE LOAD ON THE EPSU IS DIFFERENT THAN WHAT THE UNIT "LEARNED" AT IT'S ORIGINAL LOCATION DURING "TEACH-SDR 2005UALA00668Bottle · dischargedDOOR 2L PRESSURE LOW. SERVICED DOOR CYLINDER TO 1800 PSI. NO HISTORY EXCEPT ROUTINE SERVICING AT A-CHECK.SDR 2004UALA00790Bleed Valve · malfunctionedRETURN TO FIELD DUE TO A DUAL ENGINE BLEED PROBLEM. *S/D* ADJUSTED RT BLEED LEAK DETECTION LOOP IN RT PACK BAY THAT WAS CONTACTING A DUCT CLAMP. THE BLEED LEAK WARNING RESULTED IN AUTOMATIC SHUTDOWN OF THE ASSOCIATED BLEED SYSTEM. CONCURRENTLY THE AIRCRAFTSDR 2004UALA00707Hydraulic System · lowRETURN TO FIELD WITH YELLOW HYDRAULIC SYSTEM LEVEL LOW. FOUND GREEN SYSTEM CHECK VALVE AT MANIFOLD LEAKING, REPLACED O-RING. OPERATIONS CHECK NORMAL.SDR 2003UALA00769Valve · malfunctionedFLIGHT DIVERTED DUE TO A PRESSURIZATION PROBLEM. FLIGHT CREW NOTED CABIN PRESSURE ALTITUDE INCREASING DURING CRUISE, F/A'S NOTED RUMBLING IN AFT GALLEY AREA. REPLACED BOTH SAFETY VALVES.SDR 2003UALA00768Controller · failedRETURN TO FIELD DUE TO A PRESSURIZATION PROBLEM. CFDS REPORTED NO FAULTY SYSTEMS OR COMPONENTS. GROUND TESTING OF CABIN PRESSURE CONTROL, FMGC, AND ADIRS SYSTEMS REVEALED NO SYSTEM FAULTS. REPLACED CPC 2 AS PRECAUTIONARY MEASURE AS THIS WAS CPC IN CONTROL ASDR 2003UALA00414Angle · bentANGLE SUPPORTS ARE BENT UNDER THE LOWER ACCESS PANEL ON AFT CARGO DOOR. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW SUPPORT ANGLES.SDR 2001UALA02400Valve · failedCREW REPORTS AVIONICS SYSTEM FAULT. EXTRACT VALVE SHOWING CLOSED. AIRCRAFT WAS INDICATING FAULTS FOR BOTH THE SKIN AIR INLET AND OUTLET VALVES WITH THE OUTLET VALVE DEFERRED INOPERATIVE. THE SYSTEM WAS REACTIVATED ON THE GROUND AND THE FAULT WAS ISOLATED TOSDR 2000UALA00455Thermostat · inoperativeNR 2 ENGINE BLEED FAULT. *S/D* NR 2 ENGINE FAN AIR THERMOSTAT WAS REPLACED. BLEED SYSTEM CHECKED GOOD.SDR 99UAL900473Epsu · failedEPSU UNIT FWD L FAILED TEST PER NR 3 SVC. EPSU UNIT WAS THE CAUSE OF THIS MALFUNCTION. THE EPSU WAS REPLACED AND THE SYSTEM TESTED GOOD.SDR 99UAL900447Air Dist · odorFLIGHT EN ROUTE TO YVR, CREW DISCOVERED A HEATED PANEL AFT OF CB PANEL 49VU. *S/D* ACTUAL ODOR WAS NOT CONFIRMED. AS PRECAUTION, LIGHT BALLAST FIN NR 6LF WAS REPLACED AS WELL AS THE RECIRCULATION FAN FILTERS.SDR 99UAL900308Switch · failedCREW REPORTS SMOKE IN THE CABIN. EXTERNALLY LEAKING LOW OIL PRESSURE (LOP) SWITCH CAUSED OIL TO FLOW OVER LOAD COMPRESSOR CASE WHICH WAS REINJESTED INTO THE APU AND CAUSED ODOR OR SMOKE. THE APU (APS3200 SERIAL NUMBER 1413) WAS REMOVED AND ROUTED THROUGH SUN
Back to N810UA