N813UA
Service difficulty reports · 113
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N813UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N813UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013070104568Cids · malfunctionedCABIN TO COCKPIT AURAL HORN SOUNDING OFF. R & R NR 2 CID IN REF AMM, OPS CHECKED OK.SDR UALA2013062704494Oxygen Mask · no testPAX EMERGENCY O2 DROP TEST. TEST FAILED AT SEATS 12DEF, 20DEF, 22DEF, 24ABC, 25DEF, 26ABC, 27DEF, 28ABC, 30DEF, 32ABC, 34DEF AND DOOR 2L. REPACKED ALL DEFECTIVE MASKS ASSEMBLIES IAW AMM. PERFORMED OPS CHECK OF MANUAL MASK RELEASE IAW AMM. 100 PERCENT MASKSDR UALA2013062604471Container · unsecureOXYGEN MASK DROPPED 7 ABC. REPLACED EMERGENCY O2 CONTAINER FOR SEAT 7 ABC IAW AMM 1.SDR UALA2013060403878Oxygen Mask · unwanted deployF/A JUMP SEAT 1R O2 MASK SELF DEPLOYED. REPACKED DEPLOYED MASKS FWD GALLEY O2 MODULE INOPERATIVE. REPACKED AND CLOSED CONTAINER DOOR IAW MM AND PERFORMED OPES TEST IAW MM. NO FAULTS FOUND.SDR UALA2013052203551Attach Fitting · damagedINTERCOSTAL ATTACH FITTING, AT FRAME C58 BETWEEN STR 2 AND 3R HAS ONE MISDRILLED HOLE IN FRAME C58. REPAIRED INTERCOSTAL ATTACH FITTING AT FRAME C58 BETWEEN STR 2 & 3R IAW ECRA 5340-01493 & EA130125. REPAIRED CEILING PANEL. INSPECTED REPAIR IAW ECRA 5340-0SDR UALA2013052303585Shroud · crackedRIGHT OVERWING SLIDE CRACKED SHROUD. REPLACED UNIT.SDR UALA2013051003270Battery Pack · failedFORWARD FLIGHT ATTENDANT CIDS PANEL FAILED EMERGENCY LIGHT TEST. REPLACED BATTERY PACK.SDR UALA2013050703187Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. SERVICED OXYGEN SYSTEM IAW TASK 35-11-41 AND TASK 12-14-35-600-001-A. NO LEAKS NOTED. BOTTLE SAFTIED AND ACCESS SECURED. OK FOR SERVICE.SDR UALA2013020400638Attach Angle · damagedINTERCOSTAL ATTACH ANGLE HAS ONE MISDRILLED HOLE. REPAIRED INTERCOSTAL ATTACH ANGLE IAW ECRA 5340-01493 & EA130125. MAJOR REPAIR.SDR UALA2012120607050Engine · stalledNR 2 ENGINE STALL, RTFL. NEED TO ACP OVER WEIGHT LANDING CHECK. FLIGHT CREW REPORTED SMOOTH LANDING WITH A SINK RATE LESS THAN 200FPM. SAMC TEXT: REF MM 05-51-11. ACCOMPLISHED AMM 05-51-11, ALL CHECKS OKAY.SDR UALA2012110606378Clamp · missingHYD CLAMP FOUND MISSING JUST BEHIND THE LT MLG ACTUATOR. REPLACED HYD CLAMP BEHIND LT MLG ACTUATOR IAW AMM.SDR UALA2012110606377O-Ring · leakingECAM HYD Y RSVR LO LVL OCCURED ON DESCENT. FOUND TWO FITTINGS LEAKING ON PTU HYD MANIFOLD. RPL O-RINGS ON LEAKING, NO LEAKS NOTED AFTER REPLACEMENT OF O-RINGS. SERVICE YELLOW SYSTEM HYD AS NEEDED.SDR UALA2012090404931Hydraulic System · contaminatedLEFT BRAKES GRABBING ON TAXI IN. LEFT BRAKE TEMPS HIGH :JACKED LEFT MLG, NOTED BOTH MLG BRAKES SPIN FREELY. BLEED NORMAL-GREEN BRAKING SYS ON BOTH LEFT MLG BRAKES.SDR UALA2012062903488Line · failedGREEN HYD QTY LOSS ON APPROACH. NORMAL GEAR EXTENSION ACCOMPLISHED. FOUND HYDRAULIC LINE TO LEFT GEAR DOOR ACTUATOR FAILED, REPLACED LINE. ACCOMPLISHED HYDRAULIC SERVICE AND SYSTEM OPERATION TO BLEED AIR AND VERFIY OPERATION OF GEAR DOOR, NO LEAKS, SYSTEM SSDR UALA2012022701171Battery · dischargedTHE 3SV EMERGENCY LIGHT TEST FAILED. *UNIT FWD L*. RPLC'D 10W POWER SUPPLY DOOR 1L PER MM. REPLACE EMERGENCY POWER SUPPLY BATTERY AT DOOR 1L DUE TO POWER SUPPLY UNIT FAILURE. REPLACED BATTERY WITH SERVICEABLE UNIT FROM STOCK.SDR UALA2012012300459Valve · failedSUSPECT THE RIGHT WING FUEL PUMP SUCTION VALVE FAILED. REPLACED RIGHT WING SUCTION VALVE PER MM. (P/N 644-1004). REPLACED FQIC (P/N SIC5059-13-10). NEW FLSCU OPS CHECKED GOOD.SDR UALA2011121206798Light · malfunctionedCREW REPORTED THAT WHEN ACFT LOST GATE POWER, EMERGENCY LIGHTS IN FIRST CLASS AND DOOR 1L AND 1R DID NOT ILLUMINATE. LIGHTS TESTED NORMAL.SDR UALA2011071403569Unknown · damagedCREW REPORT: HEAVY HAIL ENCOUNTERED AT GATE.SDR UALA2011061402939Fan Blade · damagedENG 2 BIRD STRIKE. LCL MAINT REPORTS 2 EA FAN BLADES (21 & 22) WITH LEADING BEND IN AREA "AT" BEYOND LIMITS OF AMM. NO CRACKS NOTED AND NO EVIDENCE OF CORE INGESTION NOTED. VISUAL INSPECTION OF INLET AND SURROUNDING AREA ACCOMPLISHED, NO CRACK AT BEND BLADESDR UALA2011022800959Display · odorSMOKE IN COCKPIT. SUSPECT MCDU PCN 482-9002. FOUND SOURCE OF SMOKE TO BE CAPTAINS MCDU. REMOVED MCDU. INSPECTED CONNECTORS AND WIRING AND RECEPTACLE AND FOUND NO ABNORMALITIES. REPLACED CAPT'S MCDU PER MM AFTER CONFERRING WITH LM. OPS NORMAL.SDR UALA2011021500791Bleed Valve · faultySTALL DISPLAYED ON UPPER ECAM SCREEN (ENG 2). LOUD BANG W-ENG 2 STALL ECAM LVLG AT 5000' IN MODERATE TURBULANCE. THRUST WAS DOWN UP DOWN DURING LEVEL. ACCOMPLISHED TROUBLESHOOTING IAW TSM, ALL CHECKS GOOD. ON POWER ASSURANCE RUN HAD NO STALL, AFTER RUN PFR SDR UALA2011021400773Radome · damagedBIRDSTRIKE ON TOUCHDOWN LOWER NOSE AREA. ACCOMPLISHED BIRD STRIKE INSPECTION. FOUND RADOME DAMAGED AT RT SIDE MID SPAN. REPLACED RADOME REF MM.SDR UALA2010102503940Striker · faultyCOCKPIT DOOR FAULT LIGHT LOWER STRIKE ILLUMINATED. DISCONNECTED CONNECTOR FROM THE LOWER STRIKER, NO PART AVAILABLE TO REPLACE. INSTALLED NEW LATCH, NO HELP. REPLACED LOWER STRIKE ASSY CHECKS OK.SDR UALA2010042701406Power Supply · faultyLT OVERWING EXIT ECAM AND OVERWING INTERMITTENT. SUSPECT THE WARNING LIGHT PANEL. PANEL NO HELP. CONTINUING TO T/S. ADJUSTED LT OW EXIT DOOR PROXIMITY SENSOR. SLAVED NEW SENSOR, NO HELP. POWER SUPPLY BELOW DOOR WON'T TEST. LT OVERWING EMERGENCY LIGHT POWER SSDR 2008UALA04294Oxygen System · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (LEAKING). FOUND FAULTY OXYGEN HARNESS. REPLACED MASK ASSY.SDR 2008UALA04109Floorbeam · corrodedBEAM 80 CORRODED.SDR 2008UALA04107Floorbeam · corrodedBEAM 140 CORRODED.SDR 2008UALA04106Floorbeam · corrodedBEAM 145 CORRODED.SDR 2008UALA04098Profile · damagedTHE 2T PROFILES DAMAGED AT STA 70 WHERE BEAM 155 ATTACHED.SDR 2008UALA04076Beam · corrodedBEAM 155 CORRODED.SDR 2008UALA04040Plate · corrodedRIGHT SILL PLATE FWD HOOK PLATE CORRODED.SDR 2008UALA04039Plate · corrodedRT SILL PLATE AFT HOOK PLATE ASSY IS CORRODED.SDR 2008UALA04038Frame · corrodedFRAME FOR SHEAR PLATE CORRODED AT RT SIDE FRAME 36 TO 70.SDR 2008UALA04037Beam · corrodedBEAM 150 CORRODED.SDR 2008UALA04036Shear Plate · corrodedSHEAR PLATE CORRODED AT RT SIDE FRAME 69 TO 70.
SDR 2008UALA04034Beam · corrodedBEAM 170 CORRODED.SDR 2008UALA04033Beam · corrodedBEAM 195 CORRODED.SDR 2008UALA04035Beam · corrodedBEAM 175 CORRODED.SDR 2008UALA04032Beam · corrodedBEAM 95 CORRODED.SDR 2008UALA02694Light · malfunctionedAFT CABIN EMERGENCY ESCAPE LIGHTS ON WITH SWITCH OFF. LIGHTS EXTINGUISHED WITH SWITCH ARMED.SDR 2008UALA02506Oxygen Mask · damagedFO'S OXYGEN FACE SHIELD IS DAMAGED. CREW COMMENTS, F/O O2 MASK INSIDE RUBBER CRACKED. TOP OF NOSE CONFORMING AREA. REPLACED MASK.SDR 2008UALA02180Light · faultyAFT EMERGENCY LIGHT FROM APPROX ROW 15-16, AFT IS ILLUMINATED. AFTER SWAPPING BATTERY PACKS WAS NO HELP, THE ORIGINAL CONFIG WAS RESTORED AND LIGHTS WENT OUT AND STARTED WORKING PROPERLY. NO REPEATS.SDR 2008UALA02137Light · faultyAFT OVERHEAD EMERGENCY EXIT LIGHT ON W-SWITCH IN OFF POSITION. FOUND EPSU FAILED. REPLACED AFT L EPSU AND BATTERY.SDR 2008UALA00031Light · inoperativeEPSU EXT LOAD EMERGENCY RIGHT MESSAGE ON EMERGENCY LIGHT TEST PANEL. FWD LAMP RIGHT WING AFT OVERWING EMERGENCY LIGHT ASSY IN OUT. REPLACED RIGHT OVERWING EMERGENCY EXIT LIGHT, LAMPS OPS CHECKED OK.SDR 2008UALA0031Lamp · inoperativeEPSU EXT LOAD EMER RIGHT MESSAGE ON EMERGENCY LIGHT TEST PANEL.SDR 2007UALA05077Indicator · incorrectRTFL DUE TO NAVIGATION PROBLEMS HEADING SYSTEM NOT WORKING, POSITION NOT CORRECT.SDR 2007UALA04722Sensor · out of alignmentON GEAR RETRACTION, LANDING GEAR NOT UPLOCKED, DISPLAYED WITH ASSOCIATED ANTI-ICE STDY PITOT HEAT MESSAGE. CREW CYCLED GEAR AND ALL FAULTS CLEARED. FOUND SENSORS 24GA AND 25GA NOT ALIGNED. RE-ALIGNED SENSORS 24GA AND 25GA. PERFORMED GEAR SWING WITH SATISFSDR 2007UALA04608Control Panel · no testENG 2 AGENT1 SQUIB LT DOES NOT ILLUMINATE DURING TEST. FOUND ENG/APU FIRE CONTROL PANEL FAULT. REPLACED ENG/APU FIRE CONTROL PANEL. ALL SYSTEMS TESTED AND OPS CHECKED OK.
SDR 2007UALA03912Psu · no testDURING OPERATIONAL CHECK OF PASSENGER EMERGENCY OXYGEN SYSTEM, ROWS 12,18 LEFT AND 21, 22 AND 24 RIGHT FAILED TO DROP. *S/D* REPLACED O2 CONTAINERS AT LOCATIONS THAT FAILED TO OPEN. CHECKED AND ADJUSTED RIGGING. TESTED AGAIN AND ALL ARE NORMAL.SDR 2007UALA02382Light · inoperativeSEAT EEL LIGHT ASSY HAS ONE BULB INOP. LIGHT ASSY DAMAGED. REPLACED LIGHT ASSY.
Back to N813UA