N816UA
Service difficulty reports · 115
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N816UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N816UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013080890237Wire · severedNR 1 ENGINE PYLON FWD FIRE EXT BOTTLE WIRES, SEVERED 8 INCHES FROM CONNECTOR 5WE1-A. REPLACED WIRE 2621-19-DL20 2621-20-CF20 AND CONDUIT IAW AWM 26-21-01.SDR UALA2013061804207Seal · unsecureAIRFRAME VIBRATION FROM T/O THROUGH 17K FT. SUSPECT LOWER F/O NOSE AREA. ENGINE PARAMETERS NORMAL, FOUND SEAL AT PANEL 191BT AND 191DT SPLIT AND PROTRUDING OUT OF THE GAP. TAPED OVER DAMAGED AREA IAW AMM MT 53-004. COMPLETED VIBRATION SHEET AND TROUBLESHOSDR UALA2013061404136Power Supply · failedCABIN EMERGENCY LIGHTING MESSAGE "EPSU BATTERY AFT LIGHT". REPLACED POWER SUPPLY IAW AMM EST PASSED,SDR UALA2013052203548Trunnion · wornLEFT INBD FLAP TRUNNION WORN AT AREA D. BLENDED OUT DAMAGED AREA.SDR UALA2013041502565O-Ring · leakingON WALK AROUND, FOUND SMALL HYDRAULIC LEAK FROM GREEN SYSTEM. VERIFIED LOW QTY ON COCKPIT GAUGES. FOUND BRAKE RETURN LINE UNION O-RING BAD. REPLACED O-RING, LEAK CHECKS GOOD.SDR UALA2013032902053Seat · brokenFORWARD CABIN F/A INBRD JUMP SEAT BROKEN BY 1L. UNTANGLED SEAT-BELTS.SDR UALA2013032801993Microphone · failedCAPTAIN'S OXYGEN MASK FAILED TEST, NO TRANSMIT OF MICROPHONE. REPLACED OXYGEN MASK. CHECKED GOOD.SDR UALA2013022401103Computer · faultyMULTIPLE WARNINGS, FLT DIVERTED. REPLACED BOTH FLIGHT WARNING COMPUTERS. PRECAUTIONARY WITH TOMC SUPPORT.SDR UALA2013012100325Connector · fouledECAM MESSAGE APU AUTO SHUTDOWN DISPLAYED ON UPPER ECAM SCREEN - APU. APU AUTO SHUTDOWN DURING START ON TAXI IN. :"RE-SET" "OPS CHECK OK" HAS MADE THIS ITEM-C. APU ASD W.O. BITE MSG REF: TSM 490000-810-992-A (POSSIBLE WATER INGRESS IN PANEL 121AL). REMOVED ISDR UALA2013010300019Unknown · malfunctionedSMOKE DETECTOR FAULT DISPLAYED ON UPPER ECAM. REPLACED AFT PIT SMOKE DETECTOR 6WH. NO HELP, BOTH CHANNELS FAILING DIFFERENT SMOKE DETECTORS EACH TIME TESTED. SLAVED IN KNOWN GOOD DETECTOR NO HELP. TRIED NEW SDCU NO HELP. RE-INSTALLED ORIGINAL SDCU. REF TSSDR UALA2012121007121Lock Ring · defectiveROW 11ABC THE SEATS ARE LOOSE. REPLACED LOCK RINGS & SECURED SEATS PER AMM. ACCOMPLISHED IDT INSPECTION PER GMM- 09-10-05 AND MM25-21-41.SDR UALA2012112906863Control Unit · faultySMOKE DETECTOR MESSAGE ECAM. REPLACED SDCU PER MM, NO HELP. RESET, CHECK OK PER TASK 26-17-00-810-803A. MSG CLEARED.SDR UALA2012091305178Thrust Reverser · damagedNR 1 ENGINE INBOARD REVERSER AT THE 0100 POS (LOOKING AFT) HAS A 4X6 PIECE OF PREVIOUS REPAIR DEGRADING AND STICKING UP INTO THE AIRSTREAM. REPLACED INBOARD REVERSER PER MM. OPS CHECK PER MM AND OPS CHECK OKAY.SDR UALA2012090404973Panel · looseOVERHEAD PANEL ABOVE SEAT 2F IS LOOSE. AFT END OF PANEL IS SECURE WITH TAPE. PSU AND VIDEO MONITOR ARE NOT OBSTRUCTED, OK FOR SERVICE. REPLACED PANEL COVE LIGHT ASSEMBLY AT 2EF.SDR UALA2012071203767Girt Bar · lack of lubeDOOR 2R WILL NOT ARM. LUBED GIRT BAR FITTINGS AND ROLLERS ON DOOR FRAME. ARM DISARM FUNCTIONS OKAY.SDR UALA2012070203531Life Vest · missingFIRST OBSERVER LIFE PRESERVER MISSING FROM FLT DECK. REPLACED LIFE VEST.SDR UALA2012032301855Lever · missingCAPT SEAT SHOULDER HARNESS LOCK-UNLOCK LEVER MISSING. SAMC TEXT: REF IPC 25-11-51-01M: REPLACE SEAT ASSY. PCN 021-9017. REPLACED CAPTAIN'S SEAT PER MM, OPS CHECKS GOOD.SDR UALA2012010900216Sliding Window · out of toleranceRT SLIDING WINDOW REPLACEMENT. REPLACEMENT OF THE RT SLIDING WINDOW WAS ACCOMPLISHED PER TASK CARD 4S5686108.SDR UALA2011112706457Pump · faultedGREEN HYDRAULIC SYS OVERHEAT ILLUMINATED, FLIGHT DIVERTED. REPLACED OVERHEAT SWITCH 1381 GR, CHECKED CASE DRAIN FILTER NO DEFECTS. ACCOMPLISHED INTERNAL LEAK CHECK. NO DEFECTS. ACCOMPLISHED TSM 29-11- 00-810-802, ALL CHECKED GOOD. RAN ENGINE FOR 20 MINUTSDR UALA2011050502210Bottle · dischargedDOOR 1R ASSIST BOTTLE PRESSURE LOW. SERVICED ASSIST BOTTLE.SDR UALA2010091303404Battery · failedON 3SV FAILED EMERGENCY LIGHT TEST BTSU INT LOAD AFT LT. REPLACED BATTERY FOR EPSU 13WL. EMER LIGHT TEST OK.SDR UALA2010091303403Connector · missingBACKSHELL FOR CONNECTOR ON EPSU 13WL, IS MISSING. ALSO STRAIN RELIEF IS CRACKED. REPLACED BACKSHELL-STRAIN RELIEF ON CONNECTOR 13WLA. EMERGENCY LIGHTS TEST PASSES.SDR UALA2010052801840Computer · malfunctionedON FLT CONTROL CHECK L-R AILERON HAVE HYD NOISE-VIBRATION HEARD AND FELT IN COCKPIT. ISOLATED RT AILERON HYD SYSTEMS, RT AILERON FLUTTERS WITH ONLY GREEN HYD SYSTEM ON. ATTEMPTED ELAC 1 AND 2 RESET, NO HELP. SUSPECT RT GREEN AILERON SERVO ISSUE. THERE WERE SDR UALA2010012700329Shear Tie · crackedFRAME 73 STRINGER 31L & 32L SHEAR TIE DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED TIE.SDR UALA2010012700328Shear Tie · crackedFRAME 74 STRINGER 31L & 32L CRACKED AND DAMAGED. FRAME 74 STRINGER 31 LEFT AND 32 LEFT, SHEAR TIE CRACKED AND DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED TIE.SDR UALA2010012700327Shear Tie · crackedFRAME 74 STRINGER 32L & 33L CHECKED AND DAMAGED. FRAME 74, STRINGER 32L AND 33L SHEAR TIE IS CRACKED AND DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED TIE.SDR UALA2010011800204Slide · faultyDOOR 1R SLIDE FAILED TO DEPLOY. SLIDE STILL IN PLACE ON ACFT WITH DOOR CLOSED AND UNARMED. UNABLE TO RECORD MR NR AND DASH DUE TO POSITION OF SLIDE. REPLACED SLIDE PACK.SDR UALA2010011100146Actuator · faultyRT MLG FAILED TO EXTEND. RAT DEPLOYED. VALVE FOUND FAULTY. REPLACED CUTOUT VALVE L-G FREE FALL 2515GM. OPS NORMAL.SDR 2008UALA05668Floorbeam · corrodedFLOORBEAM - Y765 HAS CORROSION FWD OF FR68. MAJOR REPAIR ACCOMPLISHED. BEAMS REMOVED AND BRACKETS TRANSFERRED (BEAM 95 AND 150) BEAMS NEED TO BE SPLICED TOGETHER AND INSTALLED. SPLICE INSTALLED AND BEAMS 95 AND 150 INSTALLED.SDR 2008UALA05667Stiffener · crackedSTIFFENER IN NOSE WHEEL WELL LEFT SIDE IS CRACKED ON THE RISER. REPAIRED STIFFENER PER SRM 57-11-16.SDR 2008UALA05664Floorbeam · corrodedFLOORBEAM Y254 HAS CORROSION BETWEEN FR65 AND FR66 (MARKED). REPLACED BEAM 160. REPLACED FLOORBEAM 160.SDR 2008UALA05665Floorbeam · corrodedFLOORBEAM 145 HAS LOOSE RIVET(MARKED). MAJOR REPAIR ACCOMPLISHED. BEAM OUT AND ON BENCH WORKING. FOUND CORRODED BEAM REPLACED. ACP INSP OF BEAM 145.SDR 2008UALA05663Floorbeam · corrodedFLOORBEAM -Y1292 HAS CORROSION JUST AFT OF FR66. MAJOR REPAIR ACCOMPLISHED. REPLACED BEAM & SECURED WITH FASTENERS. ACP BEAM INSTALLATION FOR Y1292 FWD OF BEAM 140.SDR 2008UALA05661Floorbeam · corrodedFLOORBEAM 190 HAS CORROSION AFT OF FR68 (MARKED). MAJOR REPAIR ACCOMPLISHED. STARTED REMOVING FASTENERS. BEAM REMOVED. STARTED INSTALLATION OF BEAMS 190 AND 195. SECURED NUT PLATES FOR FLOORBOARD. INSTALLATION IS COMPLETE.SDR 2008UALA05659Floorbeam · corrodedFLOORBEAM 195 HAS CORROSION ALONG LENGTH (MARKED). MAJOR REPAIR ACCOMPLISHED. STARTED REMOVING FASTENERS. REMOVED SEVERAL FASTENERS FROM BEAM 190 TO REMOVE BEAM 195. BEAM REMOVED. INSTALLED 8 NUT PLATES ON BEAM 195 FOR PNL 261FF. SECURED NUT PLATES FOR FSDR 2008UALA05662Shear Tie · corrodedAFT RT SHEAR TIE CORRODED BETWEEN FRAME 69 & 70. MAJOR REPAIR ACCOMPLISHED. FABRICATED NEW SHEAR TIE. INSTALLED SHEAR PLATE.SDR 2008UALA05658Floorbeam · corrodedFLOORBEAM 185 HAS CORROSION AT FR68 (MARKED). MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM. BEAM OUT AND ON BENCH WORKING. STARTED INSTALLATION OF BRACKETS. RIVETING OF STANDOFF BRACKETS IS WHAT IS LEFT. DRILLED AND INSTALLED NEW BEAM 185. ALL BRACKETS SDR 2008UALA05656Sill · corrodedTHE 2R DOOR SILL CORRODED AT FWD SPLICE OUTBOARD SIDE, AT NUT CLIP HOLE. MAJOR REPAIR ACCOMPLISHED. STARTED TO REMOVE FASTENERS, INBOARD AND OUTBOARD ANGLES, NEW ANGLES FOR REPAIR IN WORK AREA. ACCOMPLISHED REPAIR PER MT 53-025. INSPECTED REPAIR.SDR 2008UALA05657Floorbeam · corrodedFLOORBEAM 175 HAS CORROSION ALONG LENGTH BETWEEN FR68 AND FR70. MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM. INSTALLED LAV AND GALLEY MOUNT FITTINGS TO NEW FLOORBEAM. DRILLED AND INSTALLED BEAM.
SDR 2008UALA05660Floorbeam · corrodedFLOORBEAM 140 HAS CORROSION ON ENTIRE LENGTH. MAJOR REPAIR ACCOMPLISHED. BEAM OUT AND ON BENCH WORKING. FAB'D SPLICES FOR BEAMS FORE AND AFT PRIMED, SEALED & INSTALLED AFT END TO BEAM 145, FWD READY TO INSTALL. INSTALLED SPLICE TO BEAM 80. REPLACED BEAM ASDR 2008UALA04065Light · no testCABIN EMERGENCY LIGHTS WILL NOT TEST.SDR 2008UALA03417Battery · faultyON EMERGENCY LIGHT TEST, FAULT KEEPS COMING UP EPSU BATT AFT L.SDR 2008UALA03191Control Unit · faultyELAC 2 FAULT INDICATIONS. SERVO 34CE1 FAILING CAUSING ELAC 2 TO FAULT CHRONICALLY. REPLACED LT INBOARD ELEVATOR SERVO CONTROL UNIT 34CE1, ADJUSTED AND OPS TESTED OK.SDR 2008UALA02507Slide · dislodgedDOOR 1L SIDE FELL OUT OF PACK. REPLACED SLIDE WITH SERVICEABLE UNIT.SDR 2008UALA02457Shear Pin · shearedFOUND DOOR 1 LEFT DOOR BOTTLE LOW AND SHEAR PIN, SHEARED IN REF TO SLIDE PACK ON JET WAY. REPLACED DIAPHRAGM AND SHEAR PIN AND SERVICED BOTTLE PER MM. ALSO REPLACED WITH SERVICABLE SLIDE.SDR 2008UALA02375Power Supply · failedEMERGENCY LIGHTS TEST FAILED. FOUND EPSU FAILED. REPLACED EPSU 13WL, TEST PASSES.SDR 2007UALA05343Epsu · failedEMERGENCY LIGHT SYSTEM FAIL TO TEST. EPSU FAILURE. REPLACED EPSU 13WL. OPS CHECKED NORMALLY.SDR 2007UALA03821Power Supply · failedFWD EMERGENCY LIGHT POWER SUPPLY FAIL TEST PER 3 SVC.SDR 2007UALA03715Accumulator · reads lowDOOR 2R EMERGENCY CYLINDER ACCUMULATOR PRESSURE LOW.SDR 2007UALA03461Computer · malfunctionedELAC 2 FAULT DISPLAYED ON UPPER ECAM SCREEN, - F-CTL. AIRCRAFT STARTED UNCOMMANDED FLIGHT MOVEMENT IN A DOWN PITCH BEFORE ECAM AND AFTER FAULT NO FURTHER UNCOMMANDED MOVEMENT. RESET ELAC2 AND PERFORMED GROUND SCAN- NO PROBLEMS NOTED, NO REPEATS SINCE ORIGIN