N819UA
Service difficulty reports · 131
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N819UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N819UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023101603070Skin · contaminatedRH ELEVATOR SHOWS LIQUID INGRESS AT 160 1/2 IN FROM I/B END, 10 IN FROM T/E 2IN IN DIAMETER. "REPAIR BEFORE NEXT FLIGHT" SUPPORT TASK ON HAECO LCQ NR9296568/40568 REPAIRED RH ELEVATOR UPPER SKIN 160.5IN FROM I/B END 10IN FROM T /E 2IN DIA ZONE 1 IAW A319 SRM SDR CALA2023101603075Skin · contaminatedLH ELEVATOR HAS LIQUID INGRESS AT 16FT 8IN FROM I/B END 4 1/2IN FROM T/E, 2IN DIAMETER, LOWER SIDE "REPAIR BEFORE NEXT FLIGHT" S UPPORT TASK ON HAECO LCQ NR9296787/40787 REPAIRED LH ELEVATOR LOWER SKIN 200IN FROM I/B END 4.5IN FROM T/ E 2IN DIA ZONE 3 IAW A319SDR CALA2023101303055Skin · contaminatedRH ELEVATOR SHOWS LIQUID INGRESS AT 24IN FROM I/B END, 12IN FROM T/E, 1IN IN DIAMETER. "REPAIR BEFORE NEXT FLIGHT" SUPPORT TASK 9296567/40567 DRILLED WITNESS HOLES IN RH ELEVATOR UPPER SKIN 24IN FROM VB END 12IN FROM T/E ZONE 1 IAW A319 AMM 55-20-00-200-006 PASDR CALA2023071702269Switch · stuckCOMM 1 SINGLE PTT STUCK TRIED NEW AUDIO MANAGEMENT UNIT, NO HELP, REINSTALLED ORIGINAL UNIT. ISOLATED FAULT TO CAPTS PTT SWITCH ON CAPTS JOYSTICK. 27-92-41-710-001-A STOPPED 4. A. STEP 40 DUE CAPT PTT FAILED ON TEST. PARTS USED: 1089695,QTY :1 ROTABLE PARTS CSDR CALA2023061601892Pressure Switch · low pressureCREW REPORTED HYD BY LO PRESSURE IN ROUTE TO SLC FLIGHT 2164. BLUE SYS PRESSURE READS 3000PSI, QUANTITY NORMAL. ALL OTHER SYSTEMS FUNCTION NORMAL. MEL 2930V PER MX CONTROL MUST HAVE POSITIVE FIX, UNABLE TO APPROVE MEL AT THIS TIME. UPLOADED PICS SFO MX TO FOLLSDR CALA2022111603139Skin · gougedPREVIOUS REWORK WITH DEEP GOUGE 2EA. AFTER PAINT REMOVAL ON FUSELAGE SKIN BTW FR. 22-23 STGR.42LH-43LH, REFERENCE TO D/O 5001188947-0010. LTPR NR# 5001189575-0010. REV. 142.PERFORMED LOCAL FABRICATION OF REPAIR DOUBLER AS PER INSPECTION INTERVALS OF TBD. REF. SDR CALA2022021400380Lanyard · missingPDA 3 FUEL CAP LANYARD MISSING PDA 3 ITEM CREATED REF 7979954,CDL APPLIEDSDR CALA2022020800348Fastener · missingPDA 3 FASTENER ON PANEL 192KB MISSING. FOUND FASTENER RECEPTACLE INOP. REMOVED AND REPLACED FASTENER / RECEPTACLE ON PANEL 192KB . FASTENER INSTALLEDSDR CALA2022020100283Thrust Reverser · fault messageCREW REPORTED THAT AT INITAL TAKE OFF ROLL DURRING POWER #2 ENGINE T/R "ENG REV MESSAGE UPPER ECAM POPPED PERFORMED #2 ENG T/R OPERATIONAL TEST REF AMM 78-31-00-719-041-A . SYSTEM TESTED NORMAL ALL INDICATION SHOWED NORMAL , NO WARNING MSG OR MAINT MSG RECORDESDR CALA2021031500318Manifold · leakingCREW REPORTS HYD Y RSVR LO LVL ECAM MESSAGE. YELLOW HYD SYST QTY WENT TO ZERO ON ECAM PAGE. CREW FOLLOWED QRH PROCEDURE AND SHUT OFF ENG PUMP AND ELECTRIC PUMP IN THE YELLOW SYSTEM. FLAGGED SDR FIELD DUE TO DIVERSION TO ORD ALL ISSUES RESOLVED. . REPLACED PASDR CALA2020100801165Battery · no testEMERGENCY BATTERY PACKS 11WL &12WL FAILS EMERGENCY LIGHT TEST-A3 NB-33-3-6016. REMOVED AND REPLACED 11WL & 12WL IAW A319 AMM 33-51-38-000-002-A AND 33-51-38-400-002-A. OP CHECK IS GOOD IAW A319AMM 33-51-00-7 10-001-A.SDR CALA2020100701158Light · inoperativeSEAT ROW 10L EEL LIGHT IS INOP ON HAECO LCQ REF 9298284 SPEC A3N B-53-4-0002. NR GENERATED BY V039704SDR CALA2020022400490Plate · crackedDURING INSPECTION OF 5330-05216 OPS 1 FOUND SERVIAL HOLES WITH CRACKES R/H SIDE FR 36 REPAIRED PER ECRA 5331-02616 AND EA 5330-05216 REV A OPS 3 PLACE D ON DIP TO ACCOMPLISH A PERMANENT REPAIR ON OR BEFORE 6 MONTHS FROM THE ISSUE DATE OF THIS EC/RA. PLANNING TSDR CALA2018043001198Hose · failedECAM CAUTION MESSAGE FOR G RSVR LOW LEVEL MESSAGE INOPERATIVE. HAPPENED AFTER PUTTINGGEAR DOWN CREW REPORTED TO TOMC THAT THEY RAN THE GREEN SYSTEM DRY PUMP RU RECHT NNING NO PRESSURE WILL REQUIRER PUMP AND FILTER CHANGE. TOMC-ALB REPLACED SAME, REQUIRES LEASDR CALA2017072802383Fan · failedMETALLIC AND BURNT PLASTIC SMELL IN CABIN. R CABIN FAULT ON COND PG . SMELL DISSIPATED IN 5 MIN. R AND R R/H CABIN RECIRCULATION FAN REF AMM 21-21-51. OPS CHECKED GOOD. OK FOR SERVICE.SDR CALA2017021300339Stringer · corrodedSTRINGER 31R FROM FRAMES 64 - 67 CORRODED BEYOND LIMITS. STRINGER REPLACED IAW SRM 51-42-00, AND SRM 53-41-13, FIG 11.SDR CALA2016102495837Doubler · dentedMAJOR REPAIR. DOUBLER REPAIR AFT OF DOOR 1L IS DENTED AT FRAME 23 JUST ABOVE FLOOR LEVEL. INSTALLED DOUBLER IAW SRM 53-11-11 FIG 211. MAJOR REPAIR.SDR CALA2016072895588Relay · malfunctionedON APPROACH AT 2000 AGL, GEAR HANDLE WAS PUSHED TO THE DOWN POS AND NOTHING HAPPENED. EMERGENCY DECLARED ON FOURTH ATTEMPT, GEAR CAME DOWN REPLACED RELAY 48GA AND CONNECTOR ON 49GA. WIRING SHAKEDOWN AND OPERATIONAL CHECK OF SAFETY VALVE IAW AMMSDR CALA2016062295474Power Supply · inoperativeEMERGENCY LIGHT TEST FAILS WITH MESSAGE, EPSU AFT LEFT. REPLACED POWER SUPPLY AND BATTERY PACK REF AMM33-51-38-400-002-A. CKS GOOD.SDR CALA2016021295099Epsu · faultyERROR MSG, EPSU BATTERY EMER LIGHT IS ON SIDS. REPLACED 11WL EPSU IAW AMM 33-51-38.SDR CALA2015061893982Beam · crackedRIGHT & LEFT SIDE BOX BEAM UPPER FLANGE AT FRAME 43 HAS CRACK INDICATIONS. ACCOMPLISHED EA 5331-01704 TO BOTH LT & RT FRAME 43.SDR CALA2015060893875Intercostal · corrodedFRAME 70 RT INTERCOSTAL UNDER SHEAR WEB IS CORRODED. REPLACED INTERCOSTAL IAW SRM 51-42-11.SDR CALA2015060893874Door Sill · corrodedR2 DOOR SILL CORRODED FRAME 66 - 68. REPLACED R2 DOOR SILL IAW SRM 51-42-11.SDR CALA2015060293850Skin Panel · saturatedRIGHT ELEV, UPPER SKIN PANEL HAS TRAPPED WATER INDICATION, 143" FROM INBD & 15" FROM END OF TE, 2" DIAMETER. REPAIRED ELEV UPPER SKIN IAW SRM 55-21-11 REPAIR 5E PARA 2D CONFIG 1 ZONE 1 SRI 55-21-11-2-002-00 TABLE 203.SDR CALA2014021790382Light · inoperativeEMERGENCY LIGHT TEST FAILED ON 2 SERVICE. RELAMPED OVERWING EMERGENCY EXIT LIGHT IAW MM 33-51-15, TEST PASSED.SDR CALA2014020390291Battery Pack · dischargedIAW 2 CHECK EMERGENCY EXIT LIGHTING TEST FAILED WITH EXTERNAL LIGHTS FAULT ON FWD LT BATTERY PACK 1L. WHEN POWERED UP AT HANGAR EPSU HAD BATTERY FAULT. REPLACED BATTERY PACK IAW AMM33-51-38, ACP SHUNT TEST, SYSTEM CHECKED OK.SDR CALA2014020390283Light · faultedEMERGENCY EXIT LIGHT TEST FAIL WITH EXTERNAL LIGHTS FAULT ON FWD LT BATTERY PACK 1L. TRIED NEW BATTERY & EPSU, NO HELP. 10WL A CONNECTOR PIN F RING OPEN FOR RT SLIDE 1R. SUGGEST SHUNT TEST MT33-01.SDR CALA2013122693939Fuel Cap · brokenFUEL CAP BROKEN, REPLACED FUEL CAP.SDR CALA2013121693738Sensor · inoperativeLGCIU 2 INOPERATIVE LG. REPLACED RT MLG EXT SENSOR 22GA, OPERATIONS CHECKED GOOD.SDR CALA2013110592685Unknown · odorELECTRICAL BURNING SMELL ROW 30 & AFT. INSPECTED AC IN & NEAR ROW 30 & AFT. CHECKED GALLEY OVEN, COFFEE MAKERS, CABIN LIGHTING, & PAX ENTERTAINMENT SYSTEM RAN APU WITH BOTH PACKS IAW TSM 24-00-00-810-823A. NO FAULTS NOTED.SDR CALA2013092491381Lens · missingDOOR 1L ARM-DISARM INDICATOR PLEXIGLAS LENS MISSING. REPLACED LENS.SDR CALA2013073090084Wire Harness · inoperativeROW 28C, EMERGENCY LIGHT INOPERATIVE. REPLACED WIRING HARNESS, 7260VC2-A, TESTS OK.SDR UALA2013070304646Bulb · missingAPU FIRE LIGHT BULB IN GROUND POWER ACCESS PANEL MISSING BULB AND LENS.SDR CALA2013082790781Wire Harness · unsecureATA 33-51-38 EPSU INT LOAD EMERGENCY LIGHT IS DISPLAYED AS A RESULT OF EMERGENCY LIGHT TEST. SECURED EMERGENCY LIGHT HARNESS AT SEAT 30C, TESTED OKAY.SDR UALA2013053003777Sign · overheatedREPORT ELECTRICAL ODOR IN FWD CABIN DURING DESCENT. FOUND CENTER AISLE LAVATORY LIGHT SIGN WITH EVIDENCE OF OVERHEATING. REPLACED SIGN, OPS CHECK GOOD.SDR UALA2013053003776Power Supply · faultyINTERIOR AND EXTERIOR FAULTS INDICATED ON LT OVERWING POWER SUPPLY, REPLACED THE BATTERY AND POWER SUPPLY, NO HELP. REPLACED POWER SUPPLY AND BATTERY. TESTS OK.SDR UALA2013053003775Battery · dischargedBOTH SIDES OVERWING OUTSIDE LIGHTS DO NOT COME ON WITH SWITCH IN ON POSITION. REPLACED EMERGENCY BATTERY AND SUPPLY, TEST OK. OUTSIDE OVERWING LIGHTS OPERATION OK.SDR UALA2013053003774Lens · missingEMERGENCY LT COVER MISSING AT SEAT 27C. REPLACED EMERGENCY LIGHT LENS AT 27C, OPS CHECK OK.SDR UALA2013050803234Tail Cone · crackedNR 1 ENGINE TAIL CONE HAS AN ELEVEN INCH CRACK REPORTED BY RAMP. REPLACED TAIL CONE PER AMM.SDR UALA2013050603154Actuator · leakingCREW REPORTS NR 1 ENGINE LEAKING OIL. FBO REPORT LEAK IS HYDRAULIC FLUID FROM THRUST REVERSER INBD LOWER LOCKING ACTUATOR PISTON SEAL AT A RATE OF 8-10 DR OPS PER MIN. REF AMM 78-32-43-200-010-A OK TO CARRY FORWARD.SDR UALA2013041702633Drain Valve · leakingFOUND HEAVY HYDRAULIC LEAK FROM GREEN HYD SYSTEM RESERVOIR DRAIN VALVE. REPLACED DRAIN VALVE AS PER MM 29, CHECKED GOOD.SDR UALA2013031801605Amu · faultySELCAL CHIME RUNS CONTINUOUSLY WILL NOT SILENCE. REPLACE AUDIO MGMT UNIT, REF AMM DUE TO REPEATED FAILURES. REPLACED AMU PER AMM. OPS CHECK NORMAL.SDR UALA2012121407226Screw · looseFLOOR AT ROW 23 IS SOFT AND SQEAKY. CHECKED STRUCTURE UNDER FLOORBOARD AT ROW 23. NO DEFECTS NOTED. FOUND LOOSE SCREWS ON FWD SIDE FLOORBOARD. TIGHTENED, FLOOR WAS NOT SOFT, JUST HAD SQUEAK.SDR UALA2012121207192Indication Sys · inoperativeCARGO DOOR ECAM, RTFL. RIGHT AFTER TAKEOFF RECEIVED AFT CARGO DOOR INDICATION INOP. VERIFIED DOOR CLOSED AND SECURELY LOCKED REF MEL 5270D.SDR UALA2012091205125Battery · dischargedCABIN EMERGENCY LIGHTS TEST FAILED. EPSU BATTERY AFT LEFT. REPLACED EPSU BATTERY, OP-CHECK OK.SDR UALA2012082304736Rub Strip · missingLOUD HUM FROM DOOR 1L ON DESCENT. FOUND DOOR 1L COVER PLATE MISSING FWD RUBSTRIP & REQUIRED PRELOAD ADJUSTMENT. ALL WORK DONE IAW AMM. PRESSURIZED ACFT TO CHECK FOR LEAKS, NO LEAKS NOTED.SDR UALA2012072303968Wire Harness · burnedAFT LIGHTS FLICKER AND SMELLED SMOKE. AFT GALLEY CONTROL PANEL MODULE HAS TWO BURNED WIRE BUNDLES AT AND ADJACENT TO CONNECTOR 9003ML4. REMOVED MODULE FOR ACCESS AND FOUND CONNECTOR PINS 9003ML4 BURNED. REPLACED WIRES PER WD 25-33-04 PG3.SDR UALA2012031201597Windshield · faultyL WINDSHIELD (CF575) IS IN THE SPARE CONFIGURATION PER MT 30-003. WILL NEED TO BE RETURNED TO NORMAL CONFIGURATION WHEN NEW WINDSHIELD IS INSTALLED. INSTALLED NEW WINDSCREEN. ANTI-ICE TEST GOOD.SDR UALA2012031201572Structure · dentedDOUBLER REPAIR AFT OF DOOR 1L IS DENTED AT FRAME 23 JUST ABOVE FLOOR LEVEL. MAJOR REPAIR ACCOMPLISHED: HFEC INSP FOR DAMAGE REMOVE REF NTM51-10-08PB6, NO DAMAGE NOTED. INSTALLED DOUBLER REPAIR. N-R E38251-376078-45059.SDR UALA2012031201574Stringer · damagedSTRINGER 23L AT FRAME 23 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. REPLACED STR 23L AT FR 23. N-R E7256I-376078-45240.
Back to N819UA