N829NW
Service difficulty reports · 107
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N829NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N829NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026071904234Light · inoperative34H AND 37B EEPL LIGHT INOP. REPLACED PER A330 AMM 33-52. (8933157) AIRCRAFT WAS GROUNDEDSDR DALA2026052603169Bottle · dischargedR4 DOOR PRESSURE LOW ON FAP. SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. (8830712) AIRCRAFT WAS GROUNDED.SDR DALA2026040602190Oxygen Mask · unwanted deployFOUND ALL OXYGEN MASKS DEPLOYED IN CREW REST COMPARTMENT. TESTED AND PACKED THE OXYGEN MASKS IAW AMM 35-21. OK FOR SERVICE. (8307926) AIRCRAFT WAS GROUNDED.SDR DALA2026040902265Lens · damagedR2 ENTRY WAY EMERGENCY LIGHT LENS DAMAGED. CORRECTIVE ACTION: R/R EMERGENCY EXIT HOUSING LOCATION R2 PER A330 AMM 33-51-04. (1514171) AIRCRAFT WAS GROUNDED.SDR DALA2026020300796Bottle · low pressureR4 DOOR ASSIST BOTTLE LOW. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-15. OK FOR SERVICE. (8243446)SDR DALA2026020200753Circuit Breaker · trippedATB - DUE TO C/B TRIPPED ECAM MSG ALONG WITH FIRE BOTTLE FAULT INDICATION. FOUND CIRCUIT BREAKER FOR FIRE BOTTLE 1/B ENG 1+2 TRIPPED. PERFORMED WIRING CHECKS AT CB (37WE2) WITH NO FAULTS FOUND. REPLACED CIRCUIT BREAKER. OK FOR SERVICE. (8243430)SDR DALA2026012100464Bottle · low pressureFLT CREW REPORTED R4 DOOR PRESSURE LOW MESSAGE ON FAP. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-15. OK FOR SERVICE. (8390264)SDR DALA2025120908972Bottle · low pressureR4 DOOR DAMPER LOW. SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. (8216939)SDR DALA2025112908732Oil System · leakingDEPARTED WITH PACK 1 ACM ON MEL. CLIMBING THRU FL180, TURNED ON PACK 1 AND CABIN FILLED WITH SMOKE. RETURNED TO ATL. FOUND ODOR ORIGINATING FROM APU BLEED DUE TO INTERNAL OIL LEAK. REPLACED APU AND LT PACK ACM. PERFORMED ECS DECONTAMINATION. REPLACED OZONE ASDR DALA2025091506771Bottle · low pressureR4 DOOR ASSIST BOTTLE LOW. SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (7360916)SDR DALA2025082906389Bottle · low pressureR4 DOOR ASSIST LOW. SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. (7871218)SDR DALA2025072105484Oxygen Mask · unwanted deploySHIP 3329 OXYGEN PANEL MASK DEPLOYED. REINSTALLED O2 MASK IN CONTAINER AT SEAT 58G PER A330 AMM 35-21.SDR DALA2025072105483Oxygen Mask · unwanted deploySHIP 3329 OXYGEN PANEL MASK DEPLOYED. REINSTALLED O2 MASK IN CONTAINER AT SEAT 58D PER A330 AMM 35-21.SDR DALA2025072105482Oxygen Mask · unwanted deploySHIP 3329 OXYGEN PANEL MASK DEPLOYED. REINSTALLED O2 MASK IN CONTAINER AS PER A330 AMM 35-21.SDR DALA2025071405289Psu · inoperativeSHIP 3329 SEAT 56AB PSU INOP. REPLACED PSU ASSY PER A330 AMM 35-21. OK FOR SERVICE.SDR DALA2025061604513Bottle · low pressureSHIP 3329 DOOR ASSIST LOW ON 2L DOOR. CORRECTIVE ACTION: REPLACED AND SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (7304639)SDR DALA2025052904123Bottle · low pressureSHIP 3329 2L DOOR ASSIST PRESSURE LOW. CORRECTIVE ACTION: SERVICED 2L DOOR ASSIST BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (7489436)SDR DALA2025052103906Bottle · low pressureSHIP 3329 FOUND 2L DOOR ASSIST BOTTLE PRESS IN YELLOW BAND. CORRECTIVE ACTION: SERVICED DOOR BOTTLE PER A330 AMM 52-15. (4360270)SDR DALA2025042803283Cover · openSHIP 3329 SEAT 41 A B REPORTED OVERHEAD O2 COVER OPENED THREE TIMES IN FLIGHT. MASKS DID NOT FALL OUT. PASSENGER CLOSED OVERHEAD EACH TIME. REPORTED AFTER BLOCK IN. CORRECTIVE ACTION: RE-PACKED MASKS AND SECURED PANEL PER A330 AMM 35-23. OK FOR SERVICE. (70805SDR DALA2025033102381Wire · damagedSHIP 3329 SEAT 40AB EMERGENCY LIGHT INOP. CORRECTIVE ACTION: REPAIRED WIRES PER A330 AMM 33-52. (5702600)SDR DALA2025033102379Light · brokenSHIP 3329 SEAT 41AB & 44HJ EMERGENCY LIGHT ASSY BROKEN. CORRECTIVE ACTION: RE-SECURED SEAT 41AB AND 44HJ EMERGENCY LIGHT ASSEMBLIES PER A330 AMM 33-51. OK FOR SVC. (7178699)SDR DALA2025031401977Landing Gear · vibrationSHIP 3329 - ATO - AT 85 KTS DUE TO EXCESSIVE NOSE GEAR VIBRATION. INSPECTED NOSE GEAR, NOSE GEAR STEERING AND REPLACED BOTH NOSE TIRE ASSEMBLIES. VERIFCATION FLIGHT OK NO VIBRATION NOTED DURING TAKEOFF OR LANDING. (7178612)SDR DALA2025022001305Bottle · low pressureSHIP 3329 DOOR ASSIST PRESSURE AT 4R. CORRECTIVE ACTION: REPLACED DIAPRAGHM AND SERVICED PER A330 AMM 52-15. (0819690)SDR DALA2025021801220Bottle · low pressureSHIP 3329 CHECK DOOR PRESSURE MSG DOOR 4R. CORRECTIVE ACTION: SERVICED DOOR BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (6843084)SDR DALA2025021401146Bottle · low pressureSHIP 3329 CHECK DOOR PRESSURE ON 4R DOOR. CORRECTIVE ACTION: SERVICED DOOR BOTTLE PER A330 AMM 52-15. (6843056)SDR DALA2025021001052Heater · faultedSHIP 3329 RH PAX/CREW DR1 AFT SLIDE FITTING HEATER 8DH FAULT MSG. CORRECTIVE ACTION: REMOVED AND REPLACED AFT SLIDE FITTING HEATER 8DH PER A330 AMM 52-11-31. OK FOR SERVICE. (0802891)SDR DALA2025020700969Fitting · faultedSHIP 3329 LH PAX/CREW DR2 FWD SLIDE FITTING HEATER 11DH FAULT MSG. CORRECTIVE ACTION: LH DR2 FWD SLIDE FITTING REMOVED AND REPLACED PER A330 AMM 52-12-31. OK FOR SERVICE. (0799426)SDR DALA2025020700968Fitting · faultedSHIP 3329 LH PAX/CREW DR1 AFT SLIDE FITTING HEATER 7DH FAULT MSG. CORRECTIVE ACTION: REPLACED FITTING PER A330 AMM 52-12-31. OK FOR SERVICE. (0799423)SDR DALA2025020700967Fitting · faultedSHIP 3329 LH PAX/CREW DR1 SLIDE FITTING HEATER 5DH FAULT MSG. CORRECTIVE ACTION: REPLACED FITTING PER A330 AMM 52-12-31. OK FOR SERVICE. (0799407)SDR DALA2024112711255Bottle · low pressureSHIP 3329 4R DOOR ASSIST READS LOW. CORRECTIVE ACTION: SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (0677858)SDR DALA2024101710158Unknown · odorSHIP 3329 ON CLIMBOUT WITH APU RUNNING HAD ELECTRICAL/ CHEMICAL/BURNING ODOR IN FLIGHT DECK AND CABIN. CORRECTIVE ACTION: NO TROUBLE FOUND. REPLACED CABIN RECIRC FILTERS. BACK IN SERVICE. (0612613)SDR DALA2024092309342Wire · damagedSHIP 3329 EMER ESCAPE PATH LIGHT AT 42AB INOP. CORRECTIVE ACTION: RETERMINATED WHITE WIRE AT ROW 42AB WALL DISCONNECT. REF A330 ESPM 20-48. OK FOR SERVICE. (6023562)SDR DALA2024090908867Bottle · low pressureSHIP 3329 4R DOOR ASSIST BOTTLE LOW. CORRECTIVE ACTION: SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (5889196)SDR DALA2024090608774Bottle · low pressureSHIP 3329 4R DOOR ASSIST BOTTLE LOW. CORRECTIVE ACTION: SERVICED DOOR BOTTLE PER A330 AMM 52-15. OK FOR SERVICE. (0541713)SDR DALA2024082908564Connector · failedSHIP 3329 SEAT 34J EMERGENCY LIGHT INOP. CORRECTIVE ACTION: INSTALLED NEW WIRE CONNECTOR PER A330 AMM 33-52. OK FOR SERVICE. (5889154)SDR DALA2024071207058Wire · damagedSHIP 3329 EMERGENCY LIGHTS AT ROW 42AB INOP. CORRECTIVE ACTION: REPAIRED WIRING ON CONNECTOR (FIN 5450VC29) PER A330 ESPM 20-48. OPS CHECK GOOD. (6007821)SDR DALA2024070806865Bottle · low pressureSHIP 3329 4R DOOR ASSIST BOTTLE LOW. CORRECTIVE ACTION: SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. (6007800)SDR DALA2024062106291Bottle · low pressureSHIP 3329 4R DOOR ASSIST LOW PRESSURE. CORRECTIVE ACTION: SERVICED 4R DOOR ASSIST (DOOR DAMPER) BOTTLE IAW A330 AMM 52-10. OK FOR SERVICE. (6141301)SDR DALA2024061406077Light · damagedSHIP 3329 EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATION:31B. CORRECTIVE ACTION: REPLACED DAMAGED EMER. LIGHT ASSY AMM 33-52. OK FOR SVC. (0391729)SDR DALA2024060505804Anti-Ice Valve · faultedDIV- INTO JFK DUE TO ENG 2 ANTI-ICE VALVE CLOSED ECAM MESSAGE. CORRECTIVE ACTION: FORWARD TO MEL THEN R/R ANTI-ICE SHUTOFF VALVE PER A330 AMM 30-21. OPS CHECK GOOD.SDR DALA2024042504712Bottle · low pressureSHIP 3329 4R DOOR "CHECK DOOR LIGHT " ON FAP PANEL. CORRECTIVE ACTION: SERVICED DOOR ASSIST PER A330 AMM 52-15. (5308874)SDR DALA2024042504711Bottle · leakingSHIP 3329 FREQUENT SERVICING OF 4R DOOOR DAMPER CYLINDER. CORRECTIVE ACTION: REBUILT DOOR ASSIST CYLINDER PER A330 AMM 52-15. OK FOR SERVICE. (0310960)SDR DALA2024042404679Connector · unsecureSHIP 3329 EMER LIGHTS AT 40B & 42B INOP. CORRECTIVE ACTION: SECURED CONNECTIONS AT SEATS 40B & 42B LIGHTS CK OK. (5308866)SDR DALA2024031903457Bottle · low pressureSHIP 3329 FAP SHOWS CHECK DOOR PRESSURE AT DOOR 4R. CORRECTIVE ACTION: SERVICED DOOR DAMPER PER A330 AMM 52-10. (5830376)SDR DALA2024030402970Bottle · low pressureSHIP 3329 DOOR ASSIST DAMPER LOW ON DOOR 4R. CORRECTIVE ACTION: SERVICED DOOR DAMPER PER A330 AMM 52-10. OK FOR SERVICE. (5830318)SDR DALA2024021502267Damper · warning messageSHIP 3329 AFTER ENGINE START FAP MESSAGE CHECK DOOR PRESSURE 4R WITH AMBER INDICATION ON DOORS PAGE. CORRECTIVE ACTION: CHARGED 4R DOOR DAMPER PER A330 AMM 52-10 OPS CHK GOOD. (0201340)SDR DALA2023122710627Unknown · unknownSHIP 3329 IN FLIGHT EXIT SIGN AT 4L ILLUMINATED.LIGHT EXTINGUISHED BY SWITCHING NO SMOKING SWITCH TO ON THEN AUTO. CORRECTIVE ACTION: INFO CONSIDERED.AS PRECAUTION, OPS CHECK OF EMERGENCY LIGHTING SYSTEM C/O. CHECK SATIS. (9595502)SDR DALA2023122610587Unknown · unknownSHIP 3329 EXIT SIGNS OVER DOORS 2L AND 2R CAME ON AT 10,000 FT IN DESCENT WHEN NO SMOKING SIGN WAS TOGGLED TO ON THEN AUTO. CORRECTIVE ACTION: PERFORMED OPS TEST OF EPSU AND CABIN EMERGENCY LTS AT DOOR 2L AND 2R. LIGHTS ALL OPS TEST OK. (5150270)SDR DALA2023112809775Unknown · unknownSHIP 3329 DOOR 4R DOOR LOW PRESSURE INDICATED. CORRECTIVE ACTION: SERVICED DOOR DAMPER BOTTLE AT LOCATION 4R. (4979833)SDR DALA2023110609138Unknown · unknownSHIP 3329 AFTER JET BRIDGE REMOVED FROM A/C AT DEPARTURE F/A REPORTED R4 DOOR PRESSURE MESSAGE ON FAP. CORRECTIVE ACTION: DOOR BOTTLE UPLIFT C/O. (5018706)