N832DN
Service difficulty reports · 29
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N832DN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N832DN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026100205471Battery Pack · no testON SVC FOUND EMERGENCY LIGHT PATH ROWS 11-16 DEF INOP. REPLACED BATTERY PACK AT 11 DEF P/N AD-D717-01-100. OPS CHECK GOOD, PER B737- AMM 33-52. (LP 9339842 - AIRCRAFT WAS GROUNDED)SDR DALA2025111708374Battery Pack · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE, CAPTS SIDE, FWD OVERWING EXIT. R & R THE M2335 BATTERY PACK IAW AMM 33-51. AS A PRECAUTION, ALSO R & R BATTERY PACK M1694. OP TEST PASSED.SDR DALA2025111708373Battery Pack · no testINTERIOR OVHD EMERGENCY LIGHT EXIT LIGHTS INOPERATIVE AT SEATS 11C & 15C. R & R THE EMERGENCY BATTERY PACKS M2335 AND M1694. OPS NORMAL.SDR DALA2025102007634Engine · making metalSHIP 3832 - IFSD/ATB/DE - AIRCRAFT RETURNED TO EWR DUE TO LEFT ENGINE FAILURE. CORRECTIVE ACTION: METAL FOUND IN TAILPIPE, LEFT ENGINE REPLACED ON LOG PAGE 1260514.SDR DALA2025033102373Coffeemaker · odorSHIP 3832 -DIV- DIVERTED TO DFW DUE TO FUMES IN THE CABIN. CORRECTIVE ACTION: REPLACED COFFEE MAKER AND INSPECTED WIRING. NO DAMAGE FOUND ON WIRING.SDR DALA2025022701526Heater · smoke(LOG 6935620) SMOKE ALARM AFT LAV W/SMELL OF SMOKE. REPLACED AFT DOOR HEATER PER B737 AMM 21-45-01. ALL TEST OK.SDR DALA2024121011568Coffeemaker · odor(LOG 6502348) FA'S REPORTED HOT PLASTIC SMELL IN FWD GALLEY CIRCUIT BREAKERS PULLED SMELL DISSIPATED. R/R FWD GALLEY C/M PER B737 AMM 25-31. OPS CHK GOOD.SDR DALA2024120311413Bushing · corroded(LOG 0690855) RIGHT MAIN GEAR FORWARD TRUNNION BLOCK BUSHING, AT REAR SPAR, INBOARD TOP BUSHING HAS CORROSION UNDER BUSHING, WHITE POWDER COMING OUT. INSTALLED FABRICATED WASHER AND COMPLETED REPAIR PER B737-900 SRM 57-20-90-2R-2.SDR DALA2024120311412Bushing · corroded(LOG 0690850) RIGHT MAIN GEAR FORWARD TRUNNION BLOCK BUSHING, AT REAR SPAR, INBOARD BOTTOM BUSHING HAS CORROSION UNDER BUSHING, WHITE POWDER COMING OUT. INSTALLED FABRICATED WASHER AND COMPLETE REPAIR PER B737-900 SRM 57-20-90-2R-2.SDR DALA2024020501527Light · damaged(LOG 0184558) EMERGENCY SEAT MOUNTED LIGHTING DAMAGED /INOP. RESECURED LIGHT BEZZEL IAW B737 AMM 25-22 OK FOR SVC.SDR DALA2023100308115Battery Pack · inoperative(LOG 4428749) DURING FLIGHT CHECK FOUND BATTERY AT LOCATION 26ABC INOP. R AND R BATTERY PACK (ELIGHT) AT LOCATION 26ABC. OPS CHECK NORMAL IAW AMM 33-51.SDR DALA2023091807636Battery Pack · inoperative(LOG 4428703) DURING SVC CK FOUND E LTS OUT AT L1 & R2 DOORS. REPLACED BATT PACKS M1675 & M1672 PER B737 AMM 33-51. INSTALL TEST PASSED.SDR DALA2023070605456Battery Pack · inoperative(LOG 4983023) L2 DOOR EMER LTS INOP. REPLACED BATT @ M1673 CKS GOOD REF . MM 33-51 & WDM 33-51-14 B737. OK FOR SVC.SDR DALA2023070605455Battery Pack · inoperative(LOG 4983022) FWD AISLE EMER AND R1 EMER LTS INOP. R/R FWD RT BATTERY PACK PER B737 AMM 33-51-06. OPS CK GOOD.SDR DALA2022122908481Battery Pack · inoperativeDURING INSPECTION FOUND EMERGENCY AISLE LIGHT ABOVE SEAT 30 A,B,C INOP. MAINENANCE PLACED ITEM ON MEL. REMOVED AND REPLACED ROW 30ABC EMERGENCY AISLE LIGHT BATTERY PACK IAW B737 AMM33-51-06. OPS CK'S GOOD. ORIG SUBMISSION DATE: 12/29/2022SDR DALA2022071504903None · noneSHIP 3832 MISC/DE- DUE TO COCKPIT TEMPERATURE WAS HOT AND UNCONTROLLABLE. CORRECTIVE ACTION: RESET CIRCUIT BREAKERS. OPS CHECKS GOOD.SDR DALA2020120703992Power Supply · inoperativeDURING INSPECTION FOUND EMERGENCY LIGHTS IN ROWS 28-32 ON RIGHT SIDE OF A/C CYCLE ON AND OFF SPECIFICALLY THE TRACK LIGHTS AND TWO WHITE OVERHEAD LIGHTS. REPLACED EMERGENCY LIGHT POWER SUPPLY M02627, IAW B737 AMM 33-51-06-960-806, ALL TEST OK.SDR DALA2020113003920Oven · overheatedSMKE-ON APPROACH INTO LAS, SMOKE AND FUMES FROM F/C OVEN. CONFIRMED OVEN OVERHEAT. CORRECTIVE ACTION: REPLACED OVEN.SDR DALA2020111003661Door Frame · corrodedDURING INSPECTION FOUND CORROSION FOUND LAV G LOWER DOOR FRAME. REPAIRED REF ERA 582489-14TR REV O.SDR DALA2020111003660Door Frame · corrodedDURING INSPECTION FOUND CORROSION FOUND LAV E LOWER DOOR FRAME. REPAIRED REF ERA 582489-14TR REV O.SDR DALA2020111003659Door Frame · corrodedDURING INSPECTION FOUND CORROSION FOUND LAV D LOWER DOOR FRAME. REPAIRED REF ERA 582489-14TR REV O.SDR DALA2020111003658Door Frame · corrodedDURING INSPECTION FOUND CORROSION FOUND LAV A LOWER DOOR FRAME. REPAIRED PER ERA 582489-14TR REV O.SDR DALA2020071302577Battery Pack · dischargedDURING INSPECTION FOUND EMERGENCY EXIT LIGHTS INOP FOR ROWS 11-19 AND ROWS 22-27. T/S PER FIM 33-50 FOUND M1676 AND M1671 BATTERY PACKS BAD. REPLACED BATTERY PACKS M1671 AND M1676 PER AMM 33-51 OPS CHECK GOOD.SDR DALA2020082702871Skin · dentedDURING INSPECTION FOUND RT HORIZ STAB DENT AT STATION 278, APPROX. 3.75 INCH LONG BY 1.6 INCH WIDE BY .200 DEEP. EVALUATED DENT PER B737 SRM 55-10-01-1A. REWORKED DENT PER NOTE 7 OPTION 2.SDR DALA2019112506914Skin · gougedSHIP 3832 ON INITIAL WALK AROUND FOUND DENT AND GOUGE ON FUSELAGE APPROX. 36" AFT OF L-1 DOOR OPENING AT FLOOR LEVEL .CORRECTIVE ACTION: C/W ERA 583316-14 REV ORIG SECTION . (6362042)SDR DALA2019060603429Girt Bar · out of alignmentR1 GIRT BAR IS MIS-ALIGNED . ALIGNED 1R GIRT BAR. OPS GOOD (5481608).SDR DALA2018102906332Button · brokenSHIP 3832 CAPT O2 MASK TEST/RESET BUTTON BROKE OFF . CORRECTIVE ACTION: TURNED CREW OXY BOTTLE OFF. REPLACED O2 MASK STORAGE BOX PER AMM 35-12. FOUND CAPT OXY MASK WORN. REPLACED CAPT OXY MASK PER AMM 35-12. OPS CKS GOOD. (4744886).SDR DALA201805153160Connector · disconnectedDURING AN EMERGENCY LIGHT CHECK, FOUND THE EMERGENCY CEILING ISLE LIGHT INOPERATIVE AT 30C. FOUND THE CONNECTOR FOR BATTERY PACK DISCONNECTED AT ROW 29. CONNECTED AND OPS CHECKED NORMAL. OK FOR SERVICE.SDR DALA2018020400669Light · damagedSEAT 1C, MOUNTED EMERGENCY LIGHT PUSHED INTO THE SEAT. SECURED THE EMERGENCY LIGHT AND LENS.