N834UA
Service difficulty reports · 95
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N834UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N834UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016091495732Connector · disconnectedEMERGENCY EXIT LIGHT ABOVE R1 DOOR INOPERATIVE DURING TEST. SECURED THE CONNECTOR.SDR CALA2016021995119Container · defectivePASSENGER O2, AT SEAT 30 DEF, DID NOT OPEN DURING O2 MASK MANUAL DROP TEST IAW MM 35-23-00. REPLACED PAX EMER O2 CONTAINER IAW AMM 35-21-41. DROP CHECKED OK.SDR CALA2015052993844Unknown · odorFLIGHT ATTENDANT REPORTED PLASTIC BURNING SMELL IN AFT GALLEY AREA. OVENS & COFFEE MAKERS NOT ON. UNABLE TO DUPLICATE SMELL. CHECKED AFT LAVATORY WATER HEATER, ALL OVENS, ALL COFFEE POTS & COFFEE MAKERS. CHECKED CHILLERS WITH NO DEFECTS FOUND. FLIGHT CREWSDR CALA2015051893793Sensor · faultyGEAR DID NOT RETRACT ON 1ST TRY. REPLACED SENSOR 24GA. BITE TEST OF SENSOR GOOD IAW MM 32-31-73.SDR CALA2014111492700Connector · not seatedEMERGENCY LIGHT TEST FAILED IAW NR 2 SVC. EPSU BATTERY EMER LT. RESEATED CONNECTOR ON LT MID EMER POWER SUPPLY IAW AMM 33-51-11 TEST PASSED.SDR CALA2014100792375Door Sill · corrodedR2 DOOR SILL HAS CORROSION, AFT SIDE FRAME 68 STRINGER 23R. AFTER BLENDING FOUND BEYOND SRM ALLOWABLE LIMITS. R & R FILLER IAW SRM 51-41-14 FIG 201 PARA 5 A PRINCIPLE 5.SDR CALA2014052791143Eec · faultyENGINE 1 FADEC A FAULT. LCL MX REPORTED ENG 1 FADEC B FAULT, UNABLE TO ACCESS 1B VIA MCDU, GND SCAN FAULTING EEC1 CELL 48 FAULT CODE \XSWDOA. R & R NR 1 ENG EEC IAW AMM 72-22-34. CHECKS OKAY.SDR CALA2014022590481Attach Bolt · damagedRT THS BOX SUPPORT ATTACH BOLT & FITTING HAVE SIGNS OF LIGHTNING DAMAGE AT FRAME 77 INBD END OF RT HORIZONTAL STABILIZER. FOUND BOLT REMOVED AT START OF DAYSHIFT. HAVE NEW BOLT & BUSHINGS IN HAND, HOWEVER UPPER BUSHING ITEM 90 NEEDS APPROXIMATELY .020 INCH SDR CALA2013120993575Girt Bar · faultyORANGE GIRT BAR INDICATOR AT BOTTOM OF DOOR 2R IS NOT VISIBLE, DOOR SHOWS ARMED. R & R GIRT BAR IAW AMM CH 25-62-44-400-006-A, OPERATIONS CHECKED GOOD.SDR CALA2013111492914Linkage · excess playNOSE GEAR TARGET 24 GA LINKAGE HAS EXCESSIVE PLAY CAUSING TARGET POSITION TO BE OUT OF RANGE. REMOVED TARGET LINKAGE & SUPPORT, REPLACED LINK & SUPPORT ASSEMBLY FULL GEAR SWING, NORMAL OPERATION.SDR CALA2013110592668Support · defectiveGEAR NOT UP LOCKED DISPLAYED ON UPPER ECAM SCREEN. GEAR DID NOT COME UP 1ST ATTEMPT. NOT JUST AN INDICATION PROBLEM, RECYCLED + UP 2ND TIME. ACCOMPLISH CHRONIC REVIEW. CFDS FAULTING 24GA TGT POSITION IAW TSM 32-31-00-810-842 -A, 24GA PCN 565-1759. REPLACEDSDR CALA2013102392323Spring · distortedRT NLG DOWNLOCK SPRING DISTORTED AT LOWER FITTING. REPLACED SPRING.SDR CALA2013100391698Unknown · odorELECTRICAL SMELL IN CABIN ROWS 22-26 NOTICED BY FLIGHT ATTENDANTS & PILOT IN BACK. 1 HOUR INTO FLIGHT, FLIGHT ATTENDANTS REPORT ELECTRICAL SMELL ROWS 22 & 23 ABC. HAD FLIGHT ATTENDANT`S TURN OFF CEILING & SIDEWALL LIGHTS & PASSENGER ENTERTAINMENT SYSTEM. TSDR UALA2013053003754Fastener · looseLOOSE FASTENER ON LT FUSELAGE PANEL 197BB JUST AFT OF LT MAIN GEAR. PLACED ON DEFERRAL LOOSE SCREW ON PANEL 197BB, SECOND ROW 11 FROM TOP, REF 53-35-00, SEC 601. REPLACED LOOSE FASTENER ON LT FUSELAGE PANEL 197BB. FASTNER SECURED.SDR UALA2013031101410Strut · dischargedNOSE STRUT FULLY COMPRESSED. STARTED TO REMOVE NLG SHOCK ABSORBER ASSY TO ITEM 4C(11) PG 6 OF MM 32-21-13-000-001-A. PERFORM A FUNCTIONAL TEST OF THE NORMAL EXTENSION, RETRACTION OF THE NLG PER MM. ACP FUNCTIONAL TEST OF NORMAL EXTENSION RETRACTION.SDR UALA2013021800926Sill · corrodedR2 DOOR SILL HAS CORROSION AT FR68. INSTALLED REPAIR PER SRM 53-41-14 FIG 201. MAJOR REPAIR.SDR UALA2012081304486Oxygen Mask · leakingFIRST OFFICERS OXYGEN HARNESS IS LEAKING AND FAILS TO INFLATE. BLADDER RUPTURED. REPLACED OXYGEN MASK, OPS CHECKED GOOD.SDR UALA2012081004358Battery · faultyFWD LEFT EPSU BATTERY FAULT. REPLACED EPSU BATTERY FORWARD LEFT PER AMM.SDR UALA2012052802998Protector · failedLEFT TANK FUEL BURN, FLIGHT DIVERTED. FOUND CENTER TANK OVER PRESSURE PROTECTOR BLOWN. REPLACED CENTER TANK OVER PRESSURE PROTECTOR. NO FUEL TRANSFER NOTED.SDR UALA2012052402919Engine · stalledNR 2 ENGINE STALL. REPLACED PRECOOLER Y DUCT ON NR 2 ENG. NR 2 FEC, REPAIR OR REPLACED THE AFT PYLON, PYLON TO REVERSER 'L' SEAL ON THE LT SIDE ACCT DAMAGED. REPLACED NR 2 ENG PYLON TO REVERSER "L" SEAL ON LEFT SIDE. REPLACED NR 2 ENGINE.SDR UALA2011102405728Latch · wornPASS O2 MASK OPENED ON TAKEOFF 31ABC. LATCH WORN OUT. TAPED DOOR CLOSED AND MADE SEATS INOPERATIVE. REPACKED O2 MASKS, DROP TEST OKAY.SDR UALA2011072503757Battery Pack · inoperativeEPSU BATTERY AFT L, WHEN PERFORMING CABIN EMERGENCY LIGHTS CHECK. REPLACED BATTERY, TESTED GOOD.SDR UALA2011071703625Seal · brokenAUTOMATED EXTERNAL DEFIBRILLATOR (AED) HAS BROKEN OR MISSING GREEN SEAL. REPLACED KIT.SDR UALA2011032901494Control Unit · malfunctionedL-G GEAR NOT UPLOCK AND L-G DOORS NOT CLOSED ON TAKEOFF. COMPLETE ECAM CHECKS OKAY. SAMC TEXT: ITEM IS FAULTING PROX SNSR 25GA TGT POS. JACKED A-C. ACCOMPLISHED GEAR SWING & FREE FALL EXTENSION, RESET MANUAL EXTENSION. ALL GEAR INDICATIONS NORMAL, NO ECAMSDR UALA2010033101074Microphone · inoperativeFO'S OXYGEN MASK MICROPHONE IS INOPERATIVE. REPLACED FO'S OXYGEN MASK AND NR 2 AUDIO CONTROL PANEL.SDR 2008UALA05740Cylinder · low pressureDOOR 1 RIGHT EMERGENCY OPERATION CYLINDER PRESSURE IS LOW. SERVICED CYLINDER. SERVICED CYLINDER, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA00349Oxygen System · leakingOXY REGUL LO PR 20 PSI. FOUND CAPT O2 BOX VALVE LEAKING. REPLACED CAPT O2 BOX AND MASK. SERVICED CREW O2 TO 1610 PSI. NO LEAKS NOTED.SDR 2008UALA00096Oxygen System · low pressureLEAK CHECK O2 SYSTEM. SERVICED CREW O2 SYSTEM AND PERFORMED LEAK CHECKS OF ALL LINES AND MASKS. NO LEAKS WERE NOTED.SDR 2008UALA00087Battery Pack · failedEMERGENCY LIGHT TEST FAULTED EPSU L AND R. DUAL BATTERY PACK FAILURE. REPLACED BOTH LEFT AND RIGHT EPSU'S. OPS CHECKED NORMAL.SDR 2008UALA00086Oxygen System · low pressureFLIGHT DIVERTED DUE TO FLIGHT DECK OXYGEN PRESSURE. SERVICED CREW O2 SYSTEM AND LEAKED CHECKED THE ENTIRE SYSTEM THOROUGHLY. COULD FIND NO SOURCE OF LEAK. SUSPECT A CREW O2 MASK TO BE UNSTOWED/IMPROPERLY STOWED.SDR 2007UALA05327B-Nut · looseOXYGEN SUPPLY LOW 1380 PSI. FOUND SLOW LEAK IN CREW O2 SYSTEM. TIGHTENED B-NUT AT REGULATOR AND RESERVICED CREW O2.SDR 2007UALA05328Harness · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE CAPT O2 MASK SUPPLY SWITCH PINCHED OPEN IN STOWED POSITION. RESTOWED THE MASK CORRECTLY AND SERVICED CREW O2.SDR 2007UALA05251Lens · missingEEPM LIGHT SEAT 22C MISSING LENS. REPLACED LENS AT SEAT 22C (EEPM).SDR 2007UALA05250Oxygen Mask · unserviceableTOP LEFT STRAP ON CAPT O2 MASK NEEDS INSIDE KEEPER-FASTENER. REPLACED CAPT O2 MASK WITH A SERVICEABLE UNIT.SDR 2007UALA05047Sensor · malfunctionedLANDING GEAR NOT DOWN AND LOCKED ECAM MSG. LANDING GEAR DISAGREE AFTER LANDING. LANDING GEAR DOOR NOT CLOSED ECAM. FOUND EXCESSIVE GAP ON NLG LEFT DOOR SENSOR 39GA. REPLACED NLG LT DOOR SENSOR 39GA, PERFORMED GEAR SWINGS, OPERATING NORMALLY.
SDR 2007UALA04717Oxygen Mask · leakingCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: CURRENT PRI 830. O2 AT 1600 PSI AT START OF FLIGHT. FOUND MASK LEAKING. REPLACED THE F OBS MASK AND SERVICED THE CREW O2 SYSTEM.
SDR 2007UALA03702Lamp · burned outEEL LIGHT AT SEAT 16 ABC HAS ONE BULB OUT. RELAMPED EEL, OPS CHECK GOOD.SDR 2007UALA02884Bottle · reads lowDOOR 1R DOOR ASSIST BOTTLE LOW. LOW CYLINDER PRESSURE (UNKNOWN) SERVICED CYLINDER TO PROPER PRESSURE, NO REPEATS.SDR 2007UALA00619Actuator · malfunctionedRTFL UNDER AMBER ALERT DUE TO LOSS OF ELEVATOR CONTROL. POST FLIGHT REPORT SHOWS THS ACTUATOR POSITION ERROR 9CE REPORTED BY SEC1 ELAC 2. SUPPLEMENTAL DATA UPDATE TRIMMABLE HORIZONTAL STABILIZER (THS) ACTUATOR LOCKED UP AND WOULD NOT RESPOND TO INPUTS. WHILE SDR 2007UALA02556Tab · brokenLOWER ANTI-ROTATION TAB AT THE RT ELEVATOR HINGE FITTING III WAS FOUND BROKEN OFF. THE UPPER TAB IS INTACT. L-ANGLE FABRICATED AND INSTALLED TO REPLACE A DAMAGED ANTI-ROTATION TAB. INSPECTION OF THE REWORKED AREA SHOWED NO CRACK INDICATIONS. MAJOR REPAIR ASDR 2006UALA02003Engine · failedRETURN TO FIELD DUE TO NR 1 ENGINE FAILURE. BORESCOPE AT ORD INDICATES FAILURE OF HPC R3 BLADE. REPLACED ENGINE .SDR 2005UALA00265Warning Light · malfunctionedENGINE 2 PUMP LO PRESSURE DISPLAYED ON UPPER ECAM. REPLACED NR 2 ENG. HYDRAULIC PRESS. SWITCH, RAN ENG. LEAK CHECKS GOOD.SDR 2004UALA00615Warning Light · illuminatedFLIGHT DIVERTED DUE TO NR 2 EGT OVERTEMP MESSAGE. BLEED VALVE CHECK FOUND 4 LOOSE SCREWS AT BASE OF 10TH STG BLEED VALVE SOLENOID . INTERMITTENT BLEED VALVE OPEN WOULD GIVE OVERTEMP INDICATION. TIGHTENED SCREWS. OPERATIONS CHECK NORMAL.SDR 2002UALA00657Fuse · blownSEATS 12C, 13C, 16C, 17C & 20C ESCAPE PATH LIGHTING INOPERATIVE. REPLACED FUSE ON POWER PACK.SDR 2002UALA00280Warning System · activatedAFT CARGO DOOR ECAM DOOR PAGE INDICATIONS INOPERABLE. ON DEPARTURE ECAM DOORS, AFT CARGO CAME ON.
Back to N834UA