N836UA
Service difficulty reports · 122
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N836UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N836UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2022090502277Fuel Cap · missing*THIS IS A SUPPLEMENTAL REPORT TO THE ORIGINAL REPORT, WITH THE SAME CONTROL NUMBER, CIRCULATED ON 09/05/2022* FUELER FOUND FUEL CAP MISSING. INSTALLED NEW FUEL CAP. OPS GOOD.SDR CALA2022082402146Door · leakingDOOR 2L LEAKOUTSIDE VISIBLE AFT LOWER CORNER UPDATED MAA CODE FIX USING VENDOR MAA SCREEN UPDATED MAA CODE FIX USING VENDOR MAA SCREEN UPDATED MAA CODE EFS USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. CHECK DOOR 2L PLEASE CONTACT TOSDR CALA2021090301503Eec · failedONE TLA FAULT DISPLAYED ON UPPER ECAM SCREEN. - ENG 2 INTERMITTENT IN FLIGHT7 OR 8 TIMES USE TSM 76-00-00-810-802-B TO TROUBLESHOOT THE WIRING. PFR ATTACHED. CHECK CFDS ENG 2 FADEC A&B FOR FAULT CODE "TRAL" AND CHECK WIRING PER ABOVE FIM. CODE TRAL PER FIM TASSDR CALA2020051700972Engine · fireDURING POST HMV-3 ENGINE RUN #1 ENGINE OIL QTY DECREASED RAPIDLY FOLLOWED WITH SMOKE AND FLAMES COMING FROMTHE TURBINE AREA. ENGI NE WAS MOTORED UNTIL FIRE DEPT RESPONED. FIRE WAS PUT OUT WITH W ATER AND PURPLE-K DRY CHEMICAL SUPPRESSING AGENT. THIS OCCURED D SDR CALA2020050200885Engine · leakingSCHEDULED PARTS CHANGE, M&E P/N: 31-7200-9-0001 S/N: 0043 ENGINE, V2500-A5 (KIT) POSITION E1 1 ENG NHA POSITION E1 1 ENG IF SCHED ULED S/N NOT FOUND VERIFY S/NS IN ALL OTHER POSITIONS OR CONTACT TOMC PRIOR TO FLIGHT. IF S/N IS FOUND, RMV/RPLC. REMOVEDSDR CALA2020040600795Wire Harness · damagedAAR NR 9624666 (SUPPORT TASK) L-81-015, EEPL HARNESS FOR SEATROW S 29 AND 30 DAMAGED REMOVED AND REPLACED EEPL WIRE HARNESS FOR SEAT ROWS 29-30 IAW A 319 AMM 33-51-22-400-802C1 OPS TEST COMPLETED ON CUSTOMER WORK CARD 17-3351-1-7907 SEQ 493SDR CALA2020032700692Stringer · corroded(SUPPORT TASK) AFT CARGO HAS CORRODED STRINGER AT FR64 ST 31RT. REFER TO AAR N/R: 9624349. REMOVED STR 31R, SPLICE AT FR.64 AND FRAME FITTING AT FR. 676 IA R. 64 IAW A319 SRM 51-42-11 AND 51-44-11-801. INSTALLED STR31R A ND SPLICE/FRAME FITTING 66 IAW A319 SRMSDR CALA2020032100677Battery Pack · failedAAR N/R S/N 9623591.(A3NB-33-3-6012)L-81 NO DOT CABIN EMERGENCY LIGHT TEST FAILS WITH MESSAGE EPSU COM EMER R, EMER L REMOVED AND REPLACED EPSU EMER R AND EMER L BATTERIES IAW A319 A MM 33-51-38-000-002 AND 3351-38-400-002. OPERATIONAL TEST ACCOMP LISHED ON CUSDR CALA2020032100676Battery · failedAAR N/R S/N 9623590.(A3NB-33-3-6012)L-81 NO DOT CABIN LIGHT TEST FAILS WITH MESSAGE EPSU BATTERY FAIL FWD LEFT. REMOVED AND REPLACED FWD LEFT EPSU BATTERY IAW A319 AMM 33-51-38 -000-002-A AND 33-51-38-400-002-A. OPERATIONAL TEST ACCOMPLISHE D ON CUSTOMER CARDSDR CALA2019071801214Relay · failedINERTIAL REFERENCE (IR) 3 INOP - NAV. REQUEST MEL 3410C. MEL APPROVED BY TOMC PER 3410C, DDP C/W. PLACARD INSTALLED ITEM PLACE ON MEL. SLAVED IN ADIRU 3 REF MM 34-12-34, NO HELP, ORIGINAL REINSTALLED. REF WDM 34-11-03 REPLACED RELAY 16FP, NO HELP. IR3 TEST SHSDR CALA2018062101474Line · wornNR 1 ENGINE DID NOT SPOOL UP WHEN THE THRUST LEVERS WERE SET TO FLEX MCT. REMOVED THE PB SENSE LINE ON THE NR 1 EEC, DISCONNECTED THE DOWNSTREAM END ADJACENT TO LOWER MOISTURE TRAP. APPLIED AIR PRESSURE AND LEAK CHECKED GOOD. FOUND PB LINE SUPPORT CLAMP MSDR CALA2018031300912Epsu · inoperativeEMERGENCY LIGHTS OPS TEST FAILS MULTIPLE EPSU AND BATTERY FAULTS. REMOVED AND REPLACED EPSU 12WL IAW AMM 33-51-38-000-001-A AND 33-51-38-400-001-A. REMOVED AND REINSTALLED BATT ON AFT EPSU 13UL IAW AMM 33-51-38-000-001-A AND 33-51-38-400-001-A. PER FORMED BITESDR CALA2018031200896Light · inoperativeDURING THE DOOR WARNING SYSTEM OPERATIONAL CHECK, IT IS NOTED THE LT OVERWING EXIT DOOR DOES NOT INDICATE CLOSED WHEN THE HATCH IS INSTALLED DISARMED AND REMOVED LT OVERWING EXIT IAW AMM 52-21-11-000 -001 AND 25-62-00-481-001. TROUBLE SHOT DOOR WARNING IAW TSMSDR CALA2018031200888Skin · saturatedFLUID INGRESS INDICATION, LT ELEVATOR TOP COMPOSITE PANEL. REFERENCE TASK CARD; 3882190 17-5520-1, SRM 0 0 PB 101 & 55-21-11 PB 101) REPAIRED LT ELEVATOR AFFECTED AREAS IAW SRM 55-21-11-283-0 04 TABLE 6104 FLAGNOTE (6), SRM 55-21-11-300-005, AND SRM 51-77-13-9SDR CALA2018031200876Door Frame · crackedRT EMERGENCY EXIT DOOR HAS CRACKS AFT WINDOW. REMOVED AND REPLACED AFT PROFILE (BEAM) AND SEGMENT (D5227904620 551 AND D5227902620451) IAW SRM 51-72-11-911-001.SDR CALA2018020200460Connector · looseOVERHEAD OVERWING EMER EXIT LT INOP. FOUND CONNECTOR 6714VC PARTIALLY DISCONNECTED, RECONNECTED CONNECTOR AND LIGHTS OPS CK NORMAL AND EMERGENCY LIGHT BITE TEST GOOD REF AMM33-51-00-710-001-A.SDR CALA2017112604225Power Supply · malfunctionedCIDS EMERGENCY LIGHT TEST FAILED. MESSAGE "EPSU BATTERY EMER R" 33-35-38 RESET EMERGENCY POWER SUPPLY 12WL. OP CK NORMAL. REF AMM 33-51-00-710-001.SDR CALA2017042801146Apu · leakingAIR COND HAS AN OILY SMELL WHETHER USING ENG BLEED OR APU BLEED. RAN ENGINES ISOLATED TO NR 1 ENGINE SMELLS THE STRONGEST IN THE COCKPIT APU WAS LEAKING OIL AND HAVING IT SUCKED INTO INLET. REPLACED APU REF MM 49-11-11. OPS CHECKED NORMAL. RAN ENGINES AND APSDR CALA2017021700386Power Supply · inoperativePOWER SUPPLY BATTERY INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-38-040 1. OPS CHECKED GOOD.SDR CALA2016081195614Epsu · malfunctionedEPSU BATTERY AFT LT DISPLAYED ON F/A PANEL AFTER TEST. RESET AFT LT EPSU, OPS CHECK NORMAL IAW AMM.SDR CALA2015081194195Oxygen Mask · deployed12ABC MASKS DEPLOYED. STOWED MASKS IAW AMM 35-21-43.SDR CALA2015081194194Oxygen Mask · deployedO2 MASK DEPLOYED ROW 1. STOWED O2 MASKS IAW AMM 35-21-43.SDR CALA2015072194145Fire Warning · false activationAPU FIRE BOTTLE DISCHARGE SWITCH & APU FIRE WARNING ON. INSPECTED APU COMPARTMENT & FOUND NO EVIDENCE OF FIRE NOTED.SDR CALA2014123092874Skin · damagedINSTALLED .080 REPAIR DOUBLER ON FUSE SKIN BETWEEN STRINGER 24R & 25R AT FRAME 13, 33 INCHES FWD OF LT MAIN ENTRY DOOR IAW SRM 53-00-11 PARA 4 5 FIG 232. SRI 53-00-11-2-017-00 REQUIRES FIRST INSPECTION AFTER REPAIR EMBODIMENT CURRENT FC 19095 & FIRST INSPECTISDR CALA2014081391956Plate · damagedFOUND BURN MARK ON LOWER RT CORNER OF STATIC PORT AREA. STBY LT STATIC PORT. DISCONNECTED STBY STATIC PORT & REMOVED FROM INSIDE SURFACE. REMOVED STATIC PORT BLANKING PLATE IAW AMM 53-19-42. INSTALLED IAW AMM 53-19-42-400-001-A TO STEP 3F 7. VERIFIED ZONSDR CALA2014070191392Computer · malfunctionedFLIGHT CONTROL FLAP 1 FAULT. REPLACED NR 1 SFCC IAW AMM 27-51-34. TESTED OK ALSO CLEANED CONNECTOR ON FLAP PCU VLV BLOCK NR 1 & 2. OPERATIONS CHECK FLAPS RAN UP & DOWN 4 TIMES NO MSG NOTED.SDR CALA2013123094056Seal · missingFLIGHT ATTENDANT REPORT SQUEAL OVERWING EXIT, NOT SURE WHICH SIDE. PER FLIGHT ATTENDANT NOISE COMING FROM CEILING BETWEEN OVERWING EXITS & NOT EXIT DOORS. INSPECTED UPPER BEACON FOUND RUBBER BUNG MISSING FROM LIGHT LENS. REPLACED IAW IPC 33 -48-11-01A ITEM 2SDR CALA2013101592084Door · leakingPRESSURE LEAK DOOR 1R. BOTTOM FWD PORTION OF DOOR, 6 TO 9 O’CLOCK POSITION, LEAKS AT LOWER FWD CORNER.SDR CALA2013101592083Wire Harness · faultyRT WINDOW DISPLAYED ON UPPER ECAM SCREEN. ANTI ICE, DIFFERED IAW MEL, CFDS INTERROGATION FAULTING F/O'S SLIDING WINDOW. REPLACED HARNESS F/O'S WINDOW CONTROL. TESTED IAW 30-42-00-710-001-A. OPERATION CHECKED GOOD DF STICKER REMOVED.SDR CALA2013091191200Oxygen Mask · faultyFO CREW O2 MASK IN TEST POSITION 02 FLOWS LONGER THAN NORMAL. SWAPPED MASKS WITH O2 MASK FROM SECOND OBSERVER'S SEAT. ACCORDINGLY SECOND OBSERVER'S SEAT RENDERED INOPERATIVE, NOT TO BE OCCUPIED. REPLACED O2 MASK, SLIDING OBSERVER`S SEAT RETURNED TO SERVICE.SDR CALA2013090991152Oxygen Mask · faultyFIRST OFFICER`S OXYGEN MASK DOES NOT TEST CORRECTLY O2 KEEPS FLOWING. COMPLIED IAW MEL, PLACARD 2511S.SDR UALA2013062604432Computer · faultedELAC 2 FAULTED. R & R ELAC 2 IAW MM 27-93-00-710-001. OPS CHECKED GOOD.SDR UALA2013060703973Computer · faultySLAT SYS 1 FAULT, RTFL. REPLACED NR 1 SFCC. GROUND TEST OK.SDR UALA2013053003753Hose · deterioratedRIGHT OVERWING ESCAPE SLIDE INFLATION HOSE PROTECTIVE FOAM DETERIORATED. R & R SLIDE ASSY.SDR UALA2013013000568Target · out of adjustPASSING 10,000 FT THE DOOR 2L CABIN PR LIGHT BEGAN TO BLINK. DOOR ECAM PAGE SLIDE UNARMED. ADJUSTED PROXIMITY SWITCH TARGET 7-WN-1 REF MM. . INSTALLED NEW LOCK WASHER AND SECURED NUT AND SAFETY.SDR UALA2013012900522Controller · failedCOCKPIT AND FWD CABIN TEMP UNCONTROLLABLE. REPLACED 1 PACK CONTROLLER, ACCOMPLISHED OPS CHECK. TEST REVEALED INLET ACT FAULT AMM 21-61-34. INF- INSTALLED LEFT RAM AIR DOOR ACTUATOR 8HH PER AMM 21-61-51-400-001-B PERFORMED PACK TEMP CONTROLLER BITE FAULTED FSDR UALA2013012800494Boot · unsecureCAPTAIN`S SIDE STICK BOOT IS MISSING SECURING STRING. SECURED BOOT WITH REQUIRED TIE STRING AND ADHESIVE.SDR UALA2013010700065Control Valve · faultedNR 1 PACK OUTPUT WENT TO 60 DEG C. TURNED PACK OFF REPEAT MRM. FLT DECK INPUT AIR TEMP AT 125.. FLT DECK TEMP 100, FWD CABIN TEMP 80. COCKPIT TEMP WENT TO 132F UNCONTROLLABLE WITH NR 1 PACK ON. ACCOMPLISHED MT 21-015. OPS CHECKED GOOD.SDR UALA2012102206014Battery · faultyON 3 SERVICE FOUND AFT OVERHEAD EMERGENCY LIGHT BATTERY FAULT AT DOOR 2L. REPLACED AT DOOR 2L OVERHEAD EMERGENCY LIGHT BATTERY, GROUND TEST EMERGENCY LIGHT TEST OKAY.SDR UALA2012092705472Controller · faultyRIGHT WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. - ANTI ICE. REPLACED RIGHT WHC, TESTED OKAY.SDR UALA2012092705471Windshield · defectiveRIGHT WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. - ANTI ICE. ANTI ICE RIGHT WINDSHIELD ECAM ON CLIMBOUT. INSTALLED NEW 1R WINDSHIELD, OPS CHECK GOOD.SDR UALA2012040602141Wire Harness · damagedMAIN ENGINE WIRE HARNESS BUNDLE DAMAGED AT 6 O'CLOCK POS AFT WHERE FAN COWLS MEET. WIRE HARNESS DAMAGE IS THRU THE SHIELD AND INTO CENTER CONDUCTOR WIRES.SDR UALA2012031601742Unknown · odorOIL SMELL IN CABIN. RAN BOTH PACKS TOGETHER AND INDIVIDUALLY WITH APU AS PNEU SOURCE, DID NOT HAVE OIL SMELL IN CABIN WITH APU AS PNEU SOURCE. RAN BOTH ENGINES WITH AND WITHOUT ANTI-ICE. NO SMELL NOTED. RAN APU WITH BOOST SLIGHT SMELL NOTICED WITH LEFT PACSDR UALA2012030901549Oxygen Mask · out of positionO2 MASK DROPPED AT SEAT 28DEF. INSPECTED MASK CONTAINER, INSIDE AND OUT, ALL CHECKS NORMAL, LANYARD NORMAL, DOOR HINGE AND LATCH SECURE NORMALLY AND SHOW NO SIGNS OF DEFECT. SEAT OK FOR SERVICE, WILL NEED FULL MASK DROP WITHIN 3 DAYS REF MT 35-003.
ACCOMPLSDR UALA2012020300663Blade · missingREF LM2891-1 BLADE 13 READS RGA23183 UNABLE TO LOCATE RGA 24278 AFTER REMOVING ALL BLADES ON NR 1 ENGINE. REMOVE ALL NR 1 ENG BLADES REF MM. RE-INSTALLED BLADES PER MM AND OPBLM DIST PROGRAM DATE FEB 02-2012. HIGH VIBS OFF OF IDLE. NEED TO RE-EVALUATE. RESDR UALA2011121906925Filter · dirtyPACKS SMELL MUSTY. FOUL ODOR ON DESCENT WHEN POWER REDUCES TO IDLE THROUGHOUT CABIN. OPERATED PACKS AT FULL HIGH FULL HEAT SMELL BARELY NOTICEABLE, SUSPECT AIR FILTER CHANGE NEEDED PCN (110-2288) - (QTY 2 EACH). REPLACED BOTH FILTERS. RAN BOTH PACKS NO SMESDR UALA2011121606924Pressure Switch · defectiveG ENG 1 PUMP LO PR DISPLAYED ON UPPER ECAM SCREEN. HYD CREW COMMENTS: HYD QTY SLIGHTLY ABOVE AMBER LEVEL. SAMC TEXT: PRESSURE SWITCH WAS REPLACED ON 15DEC11.SDR UALA2011112706454Floorbeam · damagedFLOORBEAM DAMAGED, MAJOR REPAIR ACCOMPLISHED.SDR UALA2011111706296Plate · missingNR 1 ENGINE FWD MOUNT FWD & AFT ENGINE MOUNT BOLT NUTS ON INBD SIDE ARE MISSING ANTI-ROTATION PLATES. INSTALLED ANTI-ROTATION PLATES.SDR UALA2011082204493Seal · tornMOD FLAP VIB AT FULL FLAPS. RETURNED FLAPS TO 3 VIB STOPPED. RETURNED AGAIN AT FLAPS FULL. INSP INBD AND OTBD FLAPS. FOUND NO DISCREPANCIES EXCEPT FOR LT INBD TRAILING EDGE INBD RIB SEAL TORN. REPLACED WITH NEW. TRAILING EDGE INBD RIB SEALTORN. REPLACED
Back to N836UA