N837UA
Service difficulty reports · 139
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N837UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N837UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013041002423Computer · faultyF-CTL ELAC 1 PITCH FAULT PROG TEXT: - ITEM ROLLED FORWARD. (COMPLIED WITH MEL) RPR- :T/S FAULT TO ELAC 1. REMOVED AND REPLACED ELAC 1, OPS CHECK GOOD. CAT THREE PERFORMED, SEE SEQ 2692006.SDR UALA2013021500897Sliding Window · faultyRIGHT WINDOW DISPLAYED ON UPPER ECAM SCREEN. - ANTI ICE. F/O'S SLIDING WINDOW HEAT INOP. DF STICKER APPLIED. MEL C-W. REPLACED RIGHT SLIDING WINDOW.SDR UALA2013010300025Line · leakingWATER GUSHING FROM BELLY OF ACFT. SUSPECT RUPTURED WATER LINE. TROUBLESHOOTING FOUND RUPTURED WATER LINE IN CABIN FLOOR AT ROW 12ABC AND 20ABC. REPLACED WATER LINE REF AMM 20-23-38-300-002-A. PRESSURE CHECKED LINE AND NO LEAKS FOUND.SDR UALA2012100105566Check Valve · brokenG RSVR LO LEVEL DISPLAYED ON UPPER ECAM SCREEN - HYD. FOUND CHECK VALVE ON PTU MANIFOLD BROKEN. LOCATED IN LEFT WW. VALVE REMOVED. WIRING TEST CHECKED OK. CHANGED CONNECTOR AT 15HHA PER MM. GROUND TESTED GOOD.SDR UALA2012082304703Lens · unsecureEMERGENCY EXIT LIGHTING RED LENSE ON FWD EDGE OF 1ST CLASS CLOSET FELL OFF. BROKEN OFF. :ACP INTERIM REPAIR WITH CLEAR TAPE LIGHT OP CHECK GOOD. LIGHT ASSY CLIP IS WEAK. ^22AUG LGA RCF-T :IPC REF 33-51-18-05 RED LENS CAP 07912-3.SDR UALA2012081404507Unknown · faultyRIGHT WINDOW DISPLAYED ON UPPER ECAM SCREEN. REPLACED RIGHT SLIDING WINDOW PANEL PER MM. RIGHT WINDOW MESSAGE ON UPPER ECAM STILL PRESENT.SDR UALA2012060803157Smoke Detector · faultyLAVATORY AND CARGO DETECTION FAULT DISPLAYED ON UPPER ECAM SCREEN, SMOKE. REPLACED AFT CARGO DETECTOR 5WH PER AMM, OPS NORMAL.SDR UALA2012041202204Light · shortedSTRONG ODOR IN AFT GALLEY OF BURNING ELECTRICS, WHEN POWER CUT. FOUND AFT LAVATORY OCCUPIED LIGHT ASSY SHORTED OUT. REPLACED SIGN ASSY AND LENS. OP'S CHECKED GOOD, NO BURNING ODOR.SDR UALA2012010900212Fastener · looseCRACK ON INBOARD ENG 1 COWL. MAINT TEXT: REV SLEEVE HAS A PANEL SEPARATION, WITH A RIVET HEAD STICKING OUT 1-8". ANEL SEPARATION IS BETWEEN TS5,TS8,TS10. SEPARATION MEASURES 2 & 12-32"LONG. LOCATION IS 9 AND 34" DOWN FROM PYLON AND 19 AND 3-8" FWD OF THE AFSDR UALA2011121406860Oxygen Mask · unsecureSEATS 10 ABC MASKS DROPPED ON LANDING. CHECKD O2 GENERATOR, PIN IN PLACE AND NOT ACTIVATED. REPACKED MASKS AND CLOSE DOOR. CHECKED LATCH FOR DEFECTS. PLACE TAPE OVER MODULE TO SECURE DOOR.SDR UALA2011111506268Fence · damagedCREW REPORT: LIGHTNING STRIKE. NOT SURE OF ACTUAL LOCATION. SAMC TEXT: CONTACT SAMC, INSPECT PER MM 05-51-18 (FAXED) LEFT WINGTIP FENCE, DAMAGED BY LIGHTNING IN "NO DAMAGE" AREA, REMOVE PER AMM AND CDL PER 57BA. COMPLETED LIGHTNING STRIKE INSPECTION PER AMSDR UALA2011101405584Disk · contaminatedCREW O2 OVERPRESSURE DISK ON OUTSIDE OF ACFT IS WHITE INSTEAD OF GREEN. CLEANED RESIDUE FROM DISK.SDR UALA2011083004657Battery · dischargedLEFT EPSU BATTERY FAULT DISPLAYED DURING EMERGENCY LIGHTS TEST. REPLACED BATTERY AT LEFT EPSU. EMERGENCY LIGHT TEST SATISFACTORY.SDR UALA2011081604355Closet · damagedPER CALLOUT SW2311. FIRST CLASS COAT CLOSET LOWER AFT CORNER HAS DAMAGE THAT HAS BEEN TAPED AND NOT DOCUMENTED. DAMAGE IS TAPED PER SW2311. CLOSET ASSY PART NUMBER 101744-101. SER # 005. LM INFO: PLEASE ID SOURCE OF PART NUMBER. IPC OR PART DATA PLATE? ALSDR UALA2011080203996Rivet · looseNR 1 ENG INBOARD T-R SLEEVE HAS SEVERAL LOOSE RIVETS AFT UPPER T-R ASSY (OUTER SHEETMETAL). REPLACED LOOSE RIVETS PER SRM, REPAIR NR 48, FIG 202.SDR UALA2010102503935Oxygen Mask · defectivePORTABLE OXYGEN BOTTLE MASK DEFECTIVE - OXYGEN. O2 MASK MISSING OR USED ROW 24ABC. MASK APPEARS TO BE USED, OXY BOTTLE CONSIDERED INOP PER MEL. RPL'D O2 MASK. BOTTLE WAS NORMAL.SDR UALA2010100403674Wire · shortedTHREE SERVICE EMERGENCY LIGHT TEST GIVES 2 FAULTS. EPSU INTERNAL AND EXTERNAL LIGHT FAULTS AT AFT L. FOUND WIRES PULLED AND SHORTED BELOW AFT ROW LT SEATS. RECONNECTED, TESTS OK.SDR UALA2010070102339Engine · flamed outENG 1 FLAMEOUT TAIL PIPE DURING SHUT DOWN AS REPORTED BY OBSERVER. INSPECTED INLET, EXHAUST AND TAIL SECTION OF ENG 1, NO DAMAGE FOUND. WITH CREW ASSIST RAN ENGINE, SHUTDOWN NORMAL.SDR UALA2010051701667Skin · gougedEXTERNAL FUSELAGE IS GOUGED AT FRAME 34 AT STR 43R DUE TO LONG FUSE FILLET FAIRING ATTACH SCREW. MAJOR REPAIR ACCOMPLISHED: DAMAGE REPAIRED IAW SRM, FIG 224. AREA HFEC INSPECTED, NO CRACKS NOTED. DOUBLER INSTALLED IAW SRM. REPAIR REQUIRES INSPECTION AT DEFISDR UALA2010033101087Structure · damaged20 EACH LIGHTNING STRIKES ON LT FWD FUSELAGE AFT OF BS 3500, FRAME 1, SUB ZONE 120. BURNISHED BURN AREAS. REMOVED BURNED RIVETS. REPLACED RIVETS AND LOCK FASTENERS WET PRIMED AND PAINTED AREA. HAD HFEC DONE ON HOLES. NO DEFECTS NOTED.SDR UALA2010033101086Window Frame · damaged3 EACH LIGHTNING STRIKES ON LT FWD FUSELAGE BELOW CAPT'S FIXED NR 1 AND SLIDING WINDOW AT BS 2540, SUB ZONE 210. INSTALLED 3 EA CHERRY MAX RIVETS WET. PERFORMED HFEC ON EXISTING FASTNER HOLES. NO DEFECTS NOTED.SDR UALA2009121503868Proximity Switch · faultyDOOR 1L SLIDE ARM LIGHT INTERMITTENT. ACFT WAS ON GROUND AND CABIN WAS UNPRESSURIZED WHEN DEFECT WAS NOTED. REPLACED DOOR 1L PROX SW 13WV1. ALL CHKS NORMAL.SDR UALA2009051901417Spoiler · unknownSPOILER ISSUES. RTFL.SDR UALA2009022500643Transmitter · faultyENG 2 OIL QUANTITY FLUCTUATIONS. FLIGHT DIVERTED. OIL TANK CHECKED FULL, NO OIL ADDED. REPLACED THE TRANSMITTER, OPS CHECKED OKAY.SDR UALA2009022000578Light · inoperativeRIGHT OVERWING EMERGENCY EXIT LIGHTS INOP. FOUND 1 LAMP OUT ON RT OVERWING PATHWAY, REPLACED LAMP. ALSO HAD L EPSU COMM, REPLACED LT EPSU (P/N 3214-54-10) AND BATTERY FOUND PUSHED BACK PIN ON RT EPSU, RESET PIN AND PERFORMED SUCCESSFUL EMERGENCY LIGHT TEST.SDR 2008UALA06332Anti-Ice System · malfunctionedPITOT HEAT & AUTO PILOT PROBLEMS. FLIGHT DIVERTED.
SDR 2008UALA04151Connector · unsecureEEL LIGHT AT SEAT 23ABC INOP. *S/D* SECURED CONNECTOR. OPS CHECK GOOD.SDR 2008UALA02943Hose · brokenAIRBUS RAFT DOOR BROKEN HOSE. UNKNOWN DAMAGE. REPLACED HOSE.SDR 2008UALA02052Hose · frayedF/O O2 MASK GREEN HOSE FRAYED. SWAPPED WITH 1ST OBS POSTION AND LATER REPLACED ASSY.SDR 2008UALA00369Oxygen Mask · leakingCAPTAIN'S O2 MASK LEAKING DURING TEST. UNKNOWN O2 LEAK. REPLACED CAPT O2 MASK. OPS CHECKED OK.SDR 2007UALA05238Skin · damagedFUSELAGE SKIN AT FRAME 64 AND FRAME 65 AND STRINGER 23L IS DAMAGED. MAJOR REPAIR ACCOMPLISHED AT DEN.SDR 2007UALA05208Structure · dentedDENT FOUND RUNNING IN A VERTICAL DIRECTION APPROX 3 FT FWD OF DOOR 2L. MAJOR REPAIR ACCOMPLISHED AT DEN.SDR 2007UALA00873Unknown · odorON APPROACH ELECTRICAL ODOR. GALLEY CABIN OFF, VIDEO PLAYER OFF. ODOR DISSIPATED. [SUP 06-01-07] INSPECTED FORWARD AND AFT EE COMPARTMENTS AND FORWARD GALLEY WITH NO DEFECTS NOTED. RAN BOTH AC PACKS WITH NO NOTICABLE ODOR DETECTED.SDR 2007UALA00748Structure · damagedSTA 12267, STR 42 RIVET HAS LIGHTNING DAMAGE. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA & INSTALLED DOUBLER REPAIR.SDR 2006UALA01834Battery · failedEMERGENCY LIGHT TEST FAILS -EPSU BATTERY EMER L-. REPLACED BATTERY.SDR 2006UALA00088Power Supply · faultyLEFT EPSU POWER SUPPLY MSG WHEN ACCOMPLISHING 3SVC.SDR 2006UALA00059Warning Light · illuminatedRTF DUE TO NR 2 PACK ECAM FAULT MSG AND NR 1 PACK ALREADY DEFERRED. NR 2 PACK OVERHEAT WAS REPORTED WITH NR 1 PACK ALREADY DEFERRED. NR 2 PACK FAULT DISPLAYED ON THE UPPER ECAM SCREEN. REMOVED AND REPLACED NR 2 ACM (MR21552), 11HM1, PER MM-21-52-21. OP-CHECSDR 2003UALA00437Computer · malfunctionedFLIGHT DIVERTED DUE TO STALL WARNING AND MASTER CAUTION LIGHTS. SUPPLEMENTAL DATA UPDATE THE SPURIOUS STALL WARNING WAS CAUSED BY A FAULTY FLIGHT WARNING COMPUTER (FWC) AND WAS CORRECTED BY REPLACING NR 1 FWC.SDR 2002UALA01642Iru · malfunctionedLOST CAPTAIN'S AIRSPEED TAPE INDICATION ON ROTATION. REPLACED AIR DATA INERTIAL REFERENCE UNIT NR 1. BUILT IN TEST EQUIPMENT CHECKED GOOD.