Service difficulty reports · 35

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N841SY' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SCNA20260908381Light · unsecureLEFT SIDE EXIT PATH LIGHT ROW 10-12 LIGHTING STRIP LIFTING DA34012. SECURED FLOOR STRIPPING LIGHTING IAW CMM 33-51-07. OPS CHECKED GOOD.Sep 6, 2026 · N841SY · Boeing 737800* · Emergency LightingSDR SCNA20260728330Lamp · inoperativeAFT LT GALLEY DOOR EMERGENCY SLIDE LIGHT INOPERATIVE. RELAMPED L2 DOOR SLIDE LIGHT IAW AMM 33-51-04. OPS CHECK GOODJul 27, 2026 · N841SY · Boeing 737800* · Emergency LightingSDR SCNA20260728329Lamp · inoperativeLEFT FWD OVERWING EMERGENCY EXIT WING EXIT LIGHT INOPERATIVE. RELAMPED LH FWD EMERGENCY OVERWING EXIT EXTERIOR LIGHT IAW AMM 33-51-04. OPS CHECK GOODJul 27, 2026 · N841SY · Boeing 737800* · Emergency LightingSDR SCNA20260724325Window · detachedVIEWING WINDOW OFF SLIDE 1R FELL OFF. SECURED VIEWING WINDOW ON 1R DOOR SLIDE REF AMM 25-66-00. THIS CLEARS MEL 25-10N.Jul 23, 2026 · N841SY · Boeing 737800* · Escape SlideSDR SCNA20260518205SCarpet · unsecureROW 1 RIGHT SIDE CARPET CORNER LIFTING CREATING TRIPPING HAZARD. REPLACED DOUBLESIDE CARPET TAPE IAW AMM 25-27-15 CARPET IS SECURE & TRIP HAZARD REMOVED. THIS CLEARS MEL 25-10N MDDR# 138892May 17, 2026 · N841SY · Boeing 737800* · Passenger Compartment EquipmentSDR SCNA20260518205Carpet · unsecureROW 1 RIGHT SIDE CARPET CORNER LIFTING CREATING TRIPPING HAZARD ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) )May 17, 2026 · N841SY · Boeing 737800* · Passenger Compartment EquipmentSDR SCNA20260406147Window · brokenESCAPE SLODE PRESSURE GUAGE GLASS BROKEN, R1 DOOR. REATTACHED VIEWING WINDOW IAW AMM 25-00-00 OK FOR SERVICEApr 4, 2026 · N841SY · Boeing 737800* · Escape SlideSDR SCNA20260323131Hydraulic System · overservicedDURING DECENT INTO DFW WE SMELLED A DIRTY SOCK ODOR IN THE FLIGHT DECK THE LEAD FA REPORTED THIS AS WELL. PERFORMED FIM 21-00 ASK 806 AND FOUND HYD B QTY AT OVER 106%. LOWERED HYD TO 99%. RAN APU AND NO SMELL DETECTED. RAN #1 AND #2 ENG, NO SMELL DETECTED AFTMar 22, 2026 · N841SY · Boeing 737800* · Hydraulic System, MainSDR SCNA20260107015Lamp · inoperativeROW 6ABC AREA EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED ROW 6ABC AREA EMERGENCY LIGHT LAMP IAW AMM 33-51-03-960-801, OPS CHECKED GOOD.Jan 6, 2026 · N841SY · Boeing 737800* · Emergency LightingSDR SCNA20260107014Fuse · failedL2 EXTERIOR SLIDE EMERGENCY LIGHT INOPERATIVE. FOUND FUSE IN AFT LT POWER SUPPLY INOPERATIVE.Jan 6, 2026 · N841SY · Boeing 737800* · Emergency LightingSDR SCNA20250918381SCover · missingDOOR 1R SLIDE HOUSING PLASTIC GAGE COVER MISSING ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) REMOVED 1R DOOR SLIDE INSTALLED NEW SLIDE GAUGE WINDOW REINSTALLED 1R DOOR SLIDEREF AMM 25-66-01 RII COMPLETE THIS CLEARS MEL 25-10N.Sep 17, 2025 · N841SY · Boeing 737800* · Emergency EquipmentSDR SCNA20250918381Cover · missingR1 DOOR SLIDE HOUSING PLASTIC GAGE COVER MISSING. OPENSep 17, 2025 · N841SY · Boeing 7378 · Emergency EquipmentSDR SCNA20250714259Light · unsecureDEFECT 806830: EMERGANCY LIGHTING FLOORSTRIP AT ROW 12 DEF IS AROUND & STRINKING UP OFF FLOOR - RESOLUTION: RE-SECURED EMERGANCY LIGHT FLOORSTRIP AT ROW 12DEF IAW AMM 33-51-15. NO DEFECTS NOTED AT THIS TIME. OK TO CONTIINUE AT THIS TIMEJul 14, 2025 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20250707247Web · corrodedCORROSION ON TRUSS WEB ON STA 616 APROX AT LOWER SURFACE KEEL BEAM. TRUSS WEB ON STA 616 APROX AT LOWER SURFACE KEEL BEAM WAS REPAIRED PER ETI-737-25-079 REVISION 4 AND ENGINEERING TASK CARD ENG-53SCA-11692 AND MM4-SCA-25-0014Jun 26, 2025 · N841SY · Boeing 737800* · Fuselage Miscellaneous StructureSDR SCNA20250707246Pressure Deck · crackedCRACK OF 0.625 IN LENGTH ON VERTICAL PRESSURE WEB AT LEFT SIDE OF VERTICAL PRESSURE DECK WEB STA 663 LBL 34 IN REFERENCE TASK CARD ENG-57SCA-11508 STEP 5. A). PRESSURE WEB AT LEFT SIDE OF VERTICAL PRESSURE DECK WEB STA 663 LBL 34 WAS REPAIRED PER B737-800 SRMJun 23, 2025 · N841SY · Boeing 737800* · Fuselage Main, StructureSDR SCNA20250609202Clamp · unsecureWORK ORDER 88477, NR00094:  DURING GROSS INT. HYD. SYS. LEAKAGE CHECK,  WHEN PLACING AMP.-CLAMP IN EMDP RELAY (P92), IT CREATED AN ELECTRIC ARC AND FLAMED THE COATING OF THE CABLES. CABLES IN P92 WERE REPAIRED PER B737-800 SWPM 20-10-13 AND EMDP TEST WAS PERFJun 8, 2025 · N841SY · Boeing 7378 · Navigation SystemSDR SCNA20250605197Pin · missingMISSING CLIP PIN (3 EAS) ON R1, L1 & R2 ESCAPE SLIDE STOWAGE BOX. NEW CLIP PIN (3 EAS) ON R1, L1 & R2 ESCAPE SLIDE STOWAGE BOX WAS INSTALLED PER B737-800 AMM 25-66-01.Jun 4, 2025 · N841SY · Boeing 7378 · Escape SlideSDR SCNA20250605196Release Mech · brokenBROKEN STOP RELEASE OF GIRT BART OF ESCAPE SLIDE L2. STOP RELEASE OF GIRT BAR OF SCAPE SLIDE L2.WAS REPLACED PER B737-800 AMM 25-66-01.Jun 4, 2025 · N841SY · Boeing 7378 · Emergency EquipmentSDR SCNA20250402091Bulb · inoperativeROWS 22R AND 25R AISLE EMERGENCY LIGHTS NOT ILLUMINATING. - REMOVED AND REPLACED BULBS AT ROW 22R AND 25R. CLEANED AND RESECURED WIRING HARNES AT ROW 25R. REMOVED AND REPLACED AFT RIGHT CHARGER ASSEMBLY AND BATTERY PACK. REF AMM 33-51-00. OPS CHECKS OK.Apr 2, 2025 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20250401088Light · inoperativeR2 DOOR INSIDE EMERGENCY EXIT LIGHT INOP. OPENMar 30, 2025 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20250331088Battery Pack · inoperativeR&R RT AFT EMERGENCY POWER SUPPLY BATTERY PACK IAW AMM 33-51-06.OPS CK GOOD.Mar 22, 2025 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20250217052Bracket · looseDEFECT 797137: 1L GIRT BAR BRACKET LOOSE. - - RESOLUTION: INSPECTED L1 GIRT BAR BRACKETS. NO DEFECTS NOTED. REF AMM 25-66-02. A/C OK FOR SERVICE.Feb 17, 2025 · N841SY · Boeing 7378 · Emergency EquipmentSDR SCNA20241114368Light · detachedDEFECT 776588: ESCAPE PATH LIGHTING LIFTING OFF FROM THE FLOOR AND BENT NEXT TO SEAT 12 D. RESOLUTION: INSPECTED AND REATTACHED PHOTOLUMINESCENT FLOOR STRIP LIGHTING REF AMM 33-51-15. OK FOR SERVICE.Jul 14, 2024 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20240214032Light · crackedDEFECT 731644: - EMERGENCY EXIT LIGHT STRIP CRACKED + DIRTY NEAR 2R LAV. - RESOLUTION: REMOVED AND REPLACED SAFTY GLOW STRIP LIGHT NEAR 2R LAV IAW AMM 33-51-15. OK FOR SERVICE.Feb 10, 2024 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20240108005Unknown · unknownDEFECT 731540 - - #2 ENG HYD PUMP LOW PRESS IN CRZ. B SYS QTY SHOWS 0 AND PRESSURE SHOWS >2900 PSI. #2 ENG HYD PUMP SWITCHED OFF PER QRH. - - RESOLUTION: (IN RPOGRESS)Jan 8, 2024 · N841SY · Boeing 7378 · Hydraulic Pump (Electric/Engine), MainSDR SCNA20231205255Unknown · unknownDEFECT L2 DOOR EMER LIGHT INOP - - RESOLUTION: RELAMPED EMER LIGHT L2 DOOR SLIDE REF AMM 33-51-04Dec 4, 2023 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20231011232Unknown · unknownAFT OVEN NEAR 2L DOOR F/A REPORTS WAS SMOKING AND SMELLED LIKE ELECTRICAL BURNING. STOPS AFTER OVEN SHUTOFF. OPS CHECKED #2 OVEN PER AMM 25-32-98. OPS CHECK GOOD. THIS CLEARS MEL.Oct 7, 2023 · N841SY · Boeing 7378 · Buffet/GalleysSDR SCNA20230828210Unknown · unknownDEFECT W/O 80357: 18ABC EMERGENCY AREA LIGHT ASSEMBLY LOOSE. REF AMM 33-51-03-960-802. REINSTALLED 18ABC EMERGENCY AREA LIGHT ASSEMBLY IAW AMM 33-51-03.Jul 18, 2023 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20230718204Unknown · unknownDEFECT 713405: EMER CHGR LT AFT CB BEHIND CAPT. P18-3 A10 KEEPS POPPING. - - - RESOLUTION: (IN PROGRESS)Jul 17, 2023 · N841SY · Boeing 7378 · Emergency LightingSDR SCNA20230622191Unknown · unknownOPENED DOOR SLIDE CASE AND REPLACED VIEWING WINDOW IAW AMM 20-30-11Jun 20, 2023 · N841SY · Boeing 7378 · Emergency EquipmentSDR SCNA20230622190Unknown · unknownREMOVED SLIDE AND PLACED ON TABLE ON FLOOR. OPENED SLIDE COVER PER AMM 25-64-00. REMOVED AND REPLACED DAMAGED WINDOW REF: CMM 25-60-37. NEED TO REASSEMBLE COVER AND INSTALL INTO R-2 DOOR. AFTER WINDOW SEALANT SETS UP.Jun 20, 2023 · N841SY · Boeing 7378 · Escape SlideSDR SCNA20230621191Unknown · unknownDEFECT W/O 79405 NR0008: R1 DOOR SLIDE COVER PRESSURE VIEWING WINDOW CRACKED. - - - RESOLUTION: (IN PROGRESS)Jun 20, 2023 · N841SY · Boeing 7378 · Emergency EquipmentSDR SCNA202306211901Unknown · unknownDEFECT W/O 79401, NR0007: R2 DOOR SLIDE COVER PRESSURE VIEWING WINDOW CRACKED. - - - RESOLUTION: (IN PROGRESS)Jun 20, 2023 · N841SY · Boeing 7378 · Emergency EquipmentSDR SCNA20230525162Unknown · unknownDEFECT 759564: 2R DOOR GIRT BAR STOWAGE HOOK ( RIGHT) PREVENTS GIRT BAR FROM BEING REMOVED (DIFFICULT). - - -RESOLUTION: OPS CHECKED R2 GIRT BAR STOWAGE HOOKS REF AMM 25-66-00 OPS CHECK GOOD.May 24, 2023 · N841SY · Boeing 7378 · Emergency EquipmentSDR SCNAS20220405023None · noneDEFECT: GATE RETURN FOR EXCESSIVE SMOKE FROM ENG#1. RESOLUTION: PERFORMED 79-05-TASK 801 NO EXTERNAL LEAKS NOTED. PERFORMED ENGINE VENT AND DRAINS INSPECT NO LEAKS NOTED PERFORMED SCAVENGE FILTERS INSPECTION. FOUND TEFLON MATERIAL IN FWD SUMP REF 79-00Mar 25, 2022 · N841SY · Boeing 7378 · Powerplant System
Back to N841SY