N842AE
Service difficulty reports · 84
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N842AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N842AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20210405002Battery · missingAFT CABIN EMERGENCY FLASHLIGHT MISSING BATTERY MEL 25-32 AUTH# 040011M-C REF AML PG.4689073 ITEM 1-C/A-INSTALLED BATTERY IN AFT CABIN EMERGENCY FLASHLIGHT IAW EMB 140 CMM 25-60-14 OPERATIONAL CHECK GOOD MEL#25-32 AUTH#040011M-C RESTOREDSDR SIMA20210401002Battery · missingF/A REPORTED EMERGENCY FLASHLIGHT MISSING BATTERY AT AFT CABIN. C/A-DEFERRED AFT CABIN EMERGENCY FLASHLIGHT PER MEL 25-32. C/W MEL PROCEDURE.SDR SIMA20210324002Cradle · brokenFWD FA EMEREGNCY FLASHLIGHT BRACKET BROKEN MEL 2532 AUTH# 03-330M-C AML PAGE 4720750 ITEM 1-C/A-REMOVED AND REPLACED FWD FA EMERGENCY FLASHLIGHT ASSEMBLY IAW EMB140 AMM 33-50-16 OPERATIONAL CHECK GOOD. MEL RESTORED.SDR SIMA20210323001Cradle · brokenFA EMERGENCY FLASHLIGHT BRACKET BROKEN-C/A-DEFFERED FWD F/A EMERGENCYFLASHLIGHT. COMPLIED WITH "M" PROCEDURE.SDR SIMA202009132002Battery Pack · inoperativeEMERGENCY BATTERY NR 3 INOPERABLE. C/A REMOVED AND REPLACED NR 3 EMERGENCY BATTERY AND CHARGER ASSEMBLY, IAW AMM 33-50-04. OPERATIONAL CHECK GOOD.SDR SIMA202007073001Charger · inoperativeREMOVED AND INSTALLED EMERGENCY LIGHT BATTERY CHARGER IAW AMM 33-50-04. OPS CHECKED GOOD. EMERGENCY LIGHT CHARGER.SDR SIMA2020060126010Light · inoperativeEMERGENCY LIGHTS INOPERATIVE ON MOST FWD AND MOST AFT CABIN CEILING PANELS. REMOVED AND REPLACED LIGHT BULBS ON THE FWD AND AFT MOST CEILING PANELS IAW AMM 33-50-08. OPERATIONAL CHECK GOOD.SDR SIMA202001131003Lamp · inoperativeRH EXTERNAL OVERWING EMERGENCY LIGHT FAILS TO ILLUMINATE.-C/A-REMOVED AND REPLACED RH OVER WING EMERGENCY LIGHT LAMP IAW AMM 33-50-01. OPS CHECK GOOD, NO FURTHER DEFECTS NOTED.SDR SIMA202001063002Lamp · inoperativeL/H OVER WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED L/H OVER WING EMERGENCY LIGHT IAW AMM 33-50-10. OPS CHECK GOODSDR SIMA2020010228006Fan · inoperativeSMELL IN COCKPIT WHILE TAXING-C/A-UPON INSPECTION FOUND GRINDING NOISE TO BE COMING FROM RECIRC FAN. REMOVED RECIRC FAN 2 IAW EMB 140 AMM 21-24-01 AND FOUND TO BE BURNT. INSTALLED NEW RECIRC FAN IAW EMB 140 AMM 21-24-01. OPC IAW EMB 140 AMM 21-51-00. RAN PACKSDR SIMA201912032001Charger · inoperativeAFT PAX EMERGENCY LIGHTS INCLUDING OVER WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED BATTERY POWER SUPPLY & BATTERY PACK #4 IAW AMM 33-50-04 OPS CHK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 104912SDR SIMA201911185002Lamp · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM TASK 33-50-07-000-801-A AND 33-50-07-400-801-A OPC GOOD.SDR SIMA20191101001Power Supply · failedEMERGENCY LIGHTING BATTERY ASSY/ BATTERY CHARGER REPLACEMENT REQUIRED FOR BATTERY POWER SUPPLY #3-C/A-REMOVED AND REPLACED BATTERY POWER SUPPLY #3 IAW ENVOY W/C 33-700-19. OPC GOOD IAW ENVOY W/C 33-700-17. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 83000SDR SIMA201910285003Bulb · inoperativeL/H CENTER FAIRING EXT EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED L/H CENTER FAIRING EXT EMERGENCY LIGHT BULB IAW EMB I45 AMM 33-50-10 OPS CHECK GOOD NO FURTHER DEFECTS NOTEDSDR SIMA20190905001Roller · lack of lubeMAIN CABIN DOOR VERY HARD TO OPEN. C/A-LUBRICATRED MAIN AIRFRAME ROLLERS CABIN DOOR IAW AMM 53-21-02.SDR SIMA201811298005Light · inoperativeLH OVERWING LIGHT INOP-C/A-REMOVED AND REPLACED LH OVERWING LIGHT IAW EMB 140 AMM 33-50-10 OPS CK GOODSDR SIMA20181126003Power Supply · inoperativeCABIN EMERG LT IS ON-C/A-UPON THROUBLESHOOTING FOUND BATTERY POWER SUPPLY INOP, REMOVED AND REPLACED BATTERY POWER SUPPLY AND FOR PRECAUTIONARY PURPOSE RAR BATTERY PACK #4 IAW EMB 140 AMM 33-50-04. OPC GOOD NO DEFECTS NOTED AT THIS TIME. EMERGENCY LIGHTING BASDR SIMA20180815016Light · damaged#5 LT EMERGENCY LIGHT STRIP EXTRUSION IS DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED #5 LT EMERGENCY LIGHT STRIP EXTRUSION IAW AMM 33-50-12. SEE BOW301252 FOR OPC.SDR SIMA20180815015Light · inoperativeEXTERNAL EMERGENCY LIGHT ON LT OVERWING PANEL INOP. C/A-COMPLETE:REMOVED AND REPLACED BULB ON EXTERNAL EMERGENCY LIGHT ON LT OVERWING PANEL IAW AMM 33-50-10 OPS CHECK GOOD.SDR SIMA20180815014Skin · corrodedSSI 53-20-07 FUSELAGE INTERNAL SKIN IS CORRODED BETWEEN FR 37-38 STR 21L-21R.(MARKED). C/A-COMPLETE:PERFORMED REPAIR OF FUSELAGE INTERNAL SKIN IS CORRODED BETWEEN FR 37-38 STR 21L-21R IAW ERS-EM-5300-3455.SDR SIMA20180815013Skin · crackedFUSELAGE EXTERNAL SKIN IS CRACKED AROUND 3 FASTNERS ON FR 79 RT SIDE BELOW VERITCAL STAB. C/A-COMPLETE:REPAIRED FUSELAGE EXTERNAL SKIN CRACK ON FRAME 79 RT SIDE BELOW VERTICAL STAB IAW SRM 53-32-01. SEE WIPS AND TASKS FOR DETAILS.SDR SIMA20180815012Light · damaged#1 AND #4 FLOOR EMERGENCY LIGHT STRIPS DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED #4 #1 FLOOR EMERGENCY LIGHT STRIP IAW AMM 33-50-12. SEE BOW301252 FOR OPC.SDR SIMA20180815011Light · damaged#3 LT EMERGENCY LIGHT STRIP EXTRUSION IS DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED #3 LT EMERGENCY LIGHT STRIP EXTRUSION IAW AMM 33-50-12. SEE BOW301252 FOR OPC.SDR SIMA20180815010Light · damaged#1 LT EMERGENCY LIGHT STRIP EXTRUSION IS DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED #1 LT EMERGENCY LIGHT STRIP EXTRUSION IAW AMM 33-50-12. SEE BOW301252 FOR OPC.SDR SIMA20180815009Light · damaged#7 LT EMERGENCY LIGHT STRIP EXTRUSION IS DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED #7 LT EMERGENCY LIGHT STRIP EXTRUSION IAW AMM 33-50-12. SEE BOW301252 FOR OPC.SDR SIMA20180815008Floor Support · crackedLT OMEGA BEAM FWD DIGITAL TO AFT DIGITAL INBD INTERCONNECT BRACKET IS CRACKED. C/A-COMPLETE:REMOVED AND REPLACED LT OMEGA BEAM FWD DIGITAL TO AFT DIGITAL INBD INTERCONNECT BRACKET IAW SRM 51-40-02.SDR SIMA20180815007Light · damaged#4 LT EMERGENCY LIGHT STRIP EXTRUSION IS DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED #4 LT EMERGENCY LIGHT STRIP EXTRUSION IAW AMM 33-50-12. SEE BOW301252 FOR OPC.SDR SIMA20180815017Door Sill · crackedFR 23 IS CRACKED AT RT OUTBD FLOOR SILL. C/A-COMPLETE:REPAIRED FR 23 AT RT OUTBD FLOOR SILL IAW EO#EM-53MR-1808 PART "A".SDR SIMA20180815018Crossbeam · corrodedCROSSBEAM AT FR 20 IS CORRODED. C/A-COMPLETE:REMOVED AND INSTALLED SERVICEABLE CROSSBEAM AT FR 20 IAW ETN-EM-53-139 R4 AND SRM 53-21-10. NO FURTHER ACTION REQUIRED.SDR SIMA20180815019Structure · damagedRT FLOOR EXTRUSIONS #1 THRU #8 ARE DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED RT FLOOR ECTRUSIONS #1 THRU #8 IAW AMM 33-50-12.SDR SIMA20180815020Support · crackedRT OMEGA BEAM OTBD SUPPORT IS CRACKED BETWEEN FRAMES 47-48. C/A-COMPLETE:ACCOMPLISHED REPAIR OF RT OUTBD OMEGA BEAM SUPPORT BETWEEN FR46 AND 50 IAW SRM 53-23-02.SDR SIMA20180815023Crossbeam · corrodedCROSSBEAM BETWEEN FR 24-25 IS CORRODED. C/A-COMPLETE:REMOVED AND REPLACED ALUMINUM CROSSBEAM BETWEEN FR 24-25 IAW SRM 53-22-10 AND ETN-EM-53-139R4.SDR SIMA20180815022Skin · crackedRT FUSELAGE UPPER SKIN CRACKED JUST AFT OF FRAME 75 AND ABOVE STRINGER 2R, CRACK ENDS MARKED, APPROX. 1/2" LONG. EASI #6581 USED. 100-500 KHZ PROBE, FREQ=400KHZ, V-GAIN=77.0, H-GAIN=65.0, LPF=100, ANGLE=134. C/A-COMPLETE:ACCOMPLISHED REPAIR OF CRACKED SKIN AT SDR SIMA20180815021Light · damaged#5 EMERGENCY LIGHT STRIP IS DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED #5 FLOOR EMERGENCY LIGHT STRIP IAW AMM 33-50-12. SEE BOW 301252 FOR OPC.SDR SIMA20140528004Control Unit · failedAT CRUISE ON FLIGHT 3211 CREW REPORTED WARNING MSG PITCH TRIM BACKUP INOPERATIVE. AUTOPILOT WAS ENGAGED & DECLARED EMERGENCY. THE ACFT WAS REMOVED FROM SERVICE. CORRECTIVE ACTION.SDR SIMA20140323006Light · inoperativeLEFT EXTERIOR OVERWING EMERGENCY LAMP INOPERATIVE. R & R LT EXTERIOR OVERWING EMERGENCY LIGHT LAMPS IAW AMM TASK 33-50-10-000-801-A & 33-50-10-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20140319002Light · inoperativeLT AFT EXTERNAL EMERGENCY LIGHT INOPERATIVE. R & R LAMP AT LT AFT EXTERNAL EMERGENCY LIGHT IAW AMM 33-50-10 & SMP, OPERATIONS CHECKED GOOD.SDR SIMA20140304001Light · inoperativeROW 14 EMERGENCY LIGHT INOPERATIVE. R & R ELECTROLUMINESCENT STRIP IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.SDR SIMA20140115004Inverter · inoperativeCOCKPIT STEP EMERGENCY SIGN INOPERATIVE. R & R NR 1 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11 & OPERATIONS CHECKED GOOD.SDR SIMA20140106004Holder · brokenFIRST OFFICER`S FLASHLIGHT HOLDER BROKEN. R & R FLASH LIGHT HOLDER IAW AMM 33-50-16, OPERATIONS CHECKED GOOD.SDR SIMA20131226004Nut · bentBUTTERFLY NUT THAT HOLDS CRASH AXE CLAMP CLOSED IS BENT OVER 90 DEGREES. UNABLE TO STOW OR USE CRASH AXE. INSTALLED IAW STANDARD PRACTICE.SDR SIMA20131006005Inverter · inoperativeEMERGENCY LIGHT ABOVE F/A SEAT INOPERATIVE. REPLACED INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD.SDR SIMA20130827001Display · failedAFTER DISCONNECTING GPU, DETECTED SMOKE IN COCKPIT, NOTICED EICAS BLANK AND MFD DISPLAYED AN AMBER "CHECK EICAS" MESSAGE. R & R EICAS DISPLAY UNIT IAW AMM 34-22-01, OPS GOOD, SMELL SMOKE WAS FROM FAULTY EICAS DISPLAY.SDR SIMA20130826003Wire Harness · failedCREW REPORTED THAT DURING TAKEOFF, RECEIVED AN AIR GROUND FAIL MESSAGE WITH ASSOCIATED REV DISAGREE MESSAGE ON EICAS. DECLARED EMERGENCY, RETURNED AND LANDED WITH OUT INCIDENT. VR 300' IAW MINUTE AT LANDING. ACFT REMOVED FROM SERVICE. R & R NLG WOW HARNESSDR SIMA20130824004Proximity Sensor · inoperativeTHE CREW REPORTED THAT DURING TAKEOFF THEY FELT A VIBRATION FROM THE NOSE GEAR AND HEARD A THUMP AFTER ROTATION. THE TOWER CONFIRMED RUBBER ON THE RUNWAY. THE CREW DECLARED AN EMERGENCY AND COMPLIED WITH AOM VOL 1 PROCDURES AND LANDED WITHOUT INCIDENT. THE SDR SIMA20130812001Bulb · inoperativeLEFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R BULB IAW AMM 33-50-07. OPS CHECKED GOOD.SDR SIMA20130706002Battery Pack · inoperativeDURING MX INSPECTION, FOUND EMERGENCY POWER BATTERY UNIT NR 3 INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R BATTERY UNIT. OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.SDR SIMA20130607009Light · inoperativeDURING B INSPECTION, FOUND THE LT OVER WING EMERGENCY LIGHT INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE BULB IN OVER WING EMERGENCY LIGHT IAW AMM 33-50-06-000-801-A AND 33-50-06-400-801-A. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVSDR SIMA20130530002Light · inoperativeDURING B INSPECTION, FOUND THE LT AFT OVERWING EMERGENCY LIGHT INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE LT AFT OVERWING EMERGENCY LIGHT IAW AMM 33-50-10. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR SIMA20130425007Light · inoperativeDURING MAINTENANCE INSPECTION FOUND THE LEFT OVER WING AFT EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE BULB FOR THE LEFT AFT OVER WING EMERGENCY LIGHT IAW EMB MM 33-50-10. THE OPERATIONAL CHECK WAS GOOD. THE