N8513F
Service difficulty reports · 118
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8513F' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8513F' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024102946505Floor Support · crackedCRACKED INTERCOSTAL AT FWD WET AREA BS353 RBL11 WL208.<[01] ALL STEPS COMPLETED VERIFIED THAT SRM 52-00-04-1A-1 IS APPLICABLE TO THIS AIRCRAFT. FOUND TO BE OUT OF LIMITS DUE TO NO REPAIR REFERENCE FOR CRACK AT FASTENER HOLES REPLACE PART. REMOVED INTERCOSTAL ASDR SWAA2024102946096Support Plate · corrodedCORROSION FWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE MULTIPLE AREAS AROUND NUT PLATE HOLES BS500A TO BS500I RBL22 WL156<[01] DAMAGED R/H FLOOR TO SIDEWALL SUPPORT PLATE; REPLACED DUE NO DATA FOUND ON SRM. NEW FLOOR TO SIDEWALL SUPPORT PLATE LOCATED; DRISDR SWAA2024102846074Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024102846078Floor Panel · pulledAFT FLOOR PANEL 241VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] NEWLEY FABRICATED FLOOR PANEL 241VF IAW SRM 53-00-50-2R-0 AND DRAWING 146A5810 SHEET 469.;[02] AFT FLOOR PANEL 241VF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATEDSDR SWAA2024102846079Floor Panel · pulledAFT FLOOR PANEL 241WF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241WF; UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0. DUE TO THE EXTENT OF ALL OF THE DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024102846081Floor Panel · pulledAFT FLOOR PANEL 242PF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] NEWLY FABRICATED FLOOR PANEL 241PF IAW SRM 53-00-50-2R-0 AND DRAWING 146A5810 SHEET 469.;[02] AFT FLOOR PANEL 241PF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED SDR SWAA2024102846082Floor Panel · pulledAFT FLOOR PANEL 241XF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241XF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024102846083Floor Panel · pulledAFT FLOOR PANEL 241AAF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241AAF WITH UPPER PULLED STRANDS WAS REPLACED BY FABRICATING A NEW PANEL IAW SRM 53-00-50-2R-0 AND DWG 147A5810 ID:0477;[02] ATTACHED CURE SHEET;[03] VERIFIED CORRECTIVE ACTION ITESDR SWAA2024102846091Floor Panel · pulledAFT FLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241UF; UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0. DUE TO THE AMOUNT OF DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024102846084Floor Panel · pulledAFT FLOOR PANEL 241ABF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241ABF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPAIRED PER SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024102846086Floor Panel · pulledAFT FLOOR PANEL 242UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 242UF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPAIRED PER SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024092741700Battery Pack · inoperativeMULTIPLE AFT ENTRY EMERGENCY LIGHTED SIGNS INOP<[01] 01 - REMOVED AND REPLACED EMERGENCY BATTERY CHARGER AND BATTERY M1673 PER [AMM 33-51-06-960-806-NG (POWER SUPPLY - POWER SUPPLY REPLACEMENT - PERMANENT)]SDR SWAA2024062103680Battery Pack · failedAFT R/H EMERGENCY LIGHTING BATTERY PACK FAILED CAPACITY CHECK.<[01] REMOVED AND REPLACED BATTERY PACK PER M/M 33-51-06.SDR SWAA2024062103677Seal · crackedLH HORIZONTAL; UPPER FWD SLIDER SEAL CRACKED<[01] 01 - REMOVED AND REPLACED PER [AMM 53-31-31-401 CONFIG 2-NG (STABILIZER TO BODY FRONT SPAR SLIDING SEAL - REMOVAL/INSTALLATION - PERMANENT)]SDR SWAA2024060698460Battery · inoperativeL/H INBOARD EMERGENCY FLASHLIGHT REQUIRES BATTERY REPLACEMENT.<[01] 01 - REMOVED AND REPLACED PER [AMM 25-64-00-900-806-NG (FLASHLIGHT BATTERY REPLACEMENT - PERMANENT)]SDR SWAA2024041774917Battery · failedFA REPORTS FLASHLIGHT WILL NOT TEST<[01] R&R BATTERY IAW AMM 25-64-00SDR SWAA2024022655723Bracket · looseFORWARD SERVICE DOOR GIRT BAR LOOSE<[01] ACCOMPLISHED EA M-23-125-01839 ON THE FWD SERVICE DOOR AFT GIRT BAR BRACKET.SDR SWAA2024020849855Flashlight · inoperativeFRONT CABIN FLASHLIGHT INOP. OPS CHECKED BOTH FLASHLIGHTS IAW AMM 25-64-00 OP?S CHECK GOOD AND RESEALEDSDR SWAA2024020849421Flashlight · failed1 AFT RIGHT FLASHLIGHT WILL NOT TEST.<[01] REMOVED AND REPLACED FLASHLIGHT AND BATTERY IAW AMM 25-64-00. OPS CHECK GOOD AT THIS TIME.SDR SWAA2024012243018Girt Bar · looseFWD SERVICE DOOR GRIT BAR HOLDER (RT SIDE) IS LOOSE.<[01] SECURED FWD GRIT BAR HOLDER IAW S.I.P.SDR SWAA2023122033151Flashlight · inoperativeFWD FLIGHT ATTENDANT FLASHLIGHT DOES NOT TEST<[01] REMOVED AND REPLACED OUTBID FWD FLT ATTENDANT EMERGENCY FLASHLIGHT HOLDER PER SIPSDR SWAA2023072781869Fastener · looseFWD SERVICE DOOR ESCAPE SLIDE COVER LH GIRT BAR RETAINER CLIP HAS A LOOSE INBD RIVET.<[01] REMOVED AND REPLACED FASTENER REF SRM 51-40-02.SDR SWAA2023032118548Slide · out of adjustAFT GALLEY SLIDE BRACKET BROKEN<[01] INSTALL MISSING FASTENER ON AFT GALLEY BRACKET. ALL WORK REFERENCE AM 20-60-11SDR SWAA2023011892513Megaphone · inoperativeAFT MEGAPHONE INOPERATIVE. R & R AFT GALLEY MEGAPHONE IAW AMM 25-64-00. OPS CHECKED GOOD.SDR SWAA2022102461659Battery · inoperativeFWD ENTRY AND FWD GALLEY DOOR EMERGENCY EXIT LIGHTS INOP / [01] REMOVED REPLACED AND OPS CHECKED FWD ENTRY AND FWD GALLEY EMERGENCY BATTERY PACKS PER AMM 33-51-06SDR SWAA2022102458815Intercostal · crackedR/H WING INTERCOSTAL AT UPPER TRAILING EDGE PANEL JUST INBOARD OF DEFLECTION RIB IS CRACKED AT OUTBOARD END / [01] R & R INTERCOSTAL PER SRM 51-40-02.SDR SWAA2022102457767Skin · crackedR/H WING T/E LOWER SHELF PANEL 651FB LOWER SKIN HAS A 1/2' CRACK; 30 INCHES FROM O/B END AND 2.5' FROM FWD EDGE. / [01] REMOVED DAMAGE PER SRM 51-70-05-2R-1.;[02] VERIFIED DAMAGE REMOVAL;[03] APPLIED REPAIR PER SRM 51-70-05-2R-1;[04] RICKY MINYARD (TECHNICIAN)SDR SWAA2022102456485Angle · corrodedAFT CARGO; L/H TRANSITION ANGLE STA. 727H+10 THRU STA.787+10 CORROSION OUT OF LIMITS. AFT CARGO L/H TRANSITION ANGLE STA. 727H+10 THRU STA.787+10 CORROSION OUT OF LIMITS. / [01] REMOVED DAMAGE SECTION AND FABRICATED NEW ANGLE; DRILLED AND DEBURED FROM 727H+10 SDR SWAA2022102455622Nut Plate · corrodedAFT CARGO NUT PLATE STRIP BS 773 LBL21-RBL20 HAS CORROSION IN AND AROUND NUT PLATE HOLES. / [01] OBTAINED NEW PART AND INSTALLED ON CARD TTG8Q00EH0SX IAW SRM 51-40-02.SDR SWAA2022102455611Angle · corrodedAFT CARGO LT. TRANSITION ANGLE HAS SURFACE CORROSION IN AND AROUND NUT PLATE HOLES BS727E-807. / [01] REMOVED CORROSION FROM STA.727E THRU 807-- FOUND SECTION STA. 727H+10 THRU 787+10 TO BE OUT OF LIMITS-- REMAINING SECTIONS FOUND TO BE WITHIN LIMITS FWD. OF SSDR SWAA2022102452385Gusset · crackedFWD CARGO R/H SIDE SUPPORT GUSSET CRACKED AT STA 500I RBL 60 WL 191. MRKD / [01] REMOVED GUSSET PER SRM 51-40-02;[02] REMOVED AND REPLACED WITH NEW PART PER SRM 51-40-02SDR SWAA2022102452386Gusset · crackedFWD CARGO L/H SIDE SUPPORT GUSSET IS CRACKED AT STA 500I LBL 57 WL 179. MRKD / [01] REMOVED AND REPLACED L/H GUSSET AT STA 500I PER SRM 51-40-02.SDR SWAA2022102452410Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500C+2+3+4.5+6.5+7+11.5+14+15+18+20 RBL 24-25 WL 156.(PHOTOS ATTACHED) / [01] RIGHT TRANSITION ANGLE FROM STA 500A TO STA 500I WILL BE REP0LACED ON TTG8Q00F64A7.;[02] C/W INSPECTION.SDR SWAA2022102452364Support Angle · corrodedFWD CARGO AFT BULKHEAD SUPPORT ANGLE HAS CORROSION AT STA. 500I LBL 24 TO RBL 24 WL 156. (PHOTO'S ATTACHED) / [01] AFT BULKHEAD SUPPORT ANGLE CORROSION WAS FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED AND REPLACED AFT BULKHEAD SUPPORSDR SWAA2022102452370Support Angle · corrodedFWD CARGO AFT BULKHEAD L/H CURVED SUPPORT ANGLE HAS SURFACE CORROSION AT STA. 500I LBL 25 WL 156. (PHOTOS ATTACHED) / [01] REMOVED CORROSION. REMAINING MATERIAL IS OUT OF LIMITS PER SRM 53-00-53.;[02] INSTALLED NUT PLATES PER SRM 51-40-10 <BR><BR> 10:15 P.M. SSDR SWAA2022102452366Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA. 500H +1+2+5+13+15+17 LBL 25 WL 156. (PHOTOS ATTACHED) / [01] CORROSION FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. REPAIR TO BE COMPLETED ON NON ROUTINE CARD # TTG8Q00F648G REFERENCE TSDR SWAA2022102452371Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500G +1+8+14.5+21 LBL 25 WL 156. (PHOTOS ATTACHED) / [01] CORROSION FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. REPAIR TO BE COMPLETED ON NON ROUTINE CARD # TTG8Q00F648G REFERENCE THIS SDR SWAA2022102452367Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500F +1+1.5+6.5+8+15.5+17.5+21 LBL 25 WL 156. (PHOTOS ATTACHED) / [01] CORROSION FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. REPAIR TO BE COMPLETED ON NON ROUTINE CARD # TTG8Q00F648G RESDR SWAA2022102452393Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS HEAVY SURFACE CORROSION AT STA 500E +2+6.5+9+11+14+21 LBL25 WL 156.(PHOTOS ATTACHED) / [01] CORROSION FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. REPAIR TO BE COMPLETED ON NON ROUTINE CARD # TTG8Q00F648G REFERESDR SWAA2022102452394Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500D +1.5+6.5+7.5+11+15.5 LBL 25 WL 156. (PHOTOS ATTACHED) / [01] CORROSION ON L/H TRANSITION ANGLE STA 500D +11 TO 500I WAS FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2.;[02] FABRICATED SDR SWAA2022102452407Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500B +13 RBL 24 WL 156.(PHOTOS ATTACHED) / [01] R\H TRANSITION ANGLE FROM STA 500A TO STA 500I WILL BE REPLACED ON TTG8Q00F64A7.;[02] C/W INSPECTION.SDR SWAA2022102452383Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500D+15.5 RBL 25 WL 156.(PHOTOS ATTACHED) / [01] REMOVAL AND REPLACEMENT OF RIGHT TRANSITION ANGLE FROM STA 500A TO STA 500I WILL BE ACCOMPLISHED ON TTG8Q00F64A7.;[02] C/W INSPECTION.SDR SWAA2022102452412Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500E+1.5+2.75+6.5+7+11+15.5+19+20 RBL 25 WL156.(PHOTOS ATTACHED) / [01] REMOVAL AND REPLACEMENT OF RIGHT TRANSITION ANGLE FROM STA 500A TO STA 500I WILL BE ACCOMPLISHED ON TTG8Q00F64A7.;[02] C/W INSPESDR SWAA2022102452384Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500F +1+2+6.5+8+11+14+18+20+21 RBL 25 WL 156.(PHOTOS ATTACHED) / [01] RIGHT TRANSITION ANGLE FROM STA 500A TO STA 500I WILL BE REPLACED IN TTG8Q00F64A7.;[02] C/W INSPECTION.SDR SWAA2022102452414Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500G +1+6.5+11+15.5+20+21 RBL 25 WL 156.(PHOTOS ATTACHED) / [01] REMOVAL AND REPLACEMENT OF RIGHT TRANSITION ANGLE FROM STA 500A TO STA 500I WILL BE ACCOMPLISHED ON TTG8Q00F64A7.;[02] C/W INSPECTION.SDR SWAA2022102452415Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION AT STA 500H +1+2+5+7+10+11+13+15+17+19 RBL 25 WL 156.(PHOTOS ATTACHED) / [01] REMOVAL AND REPLACEMENT OF RIGHT TRANSITION ANGLE FROM STA 500A TO STA 500I WILL BE ACCOMPLISHED ON TTG8Q00F64A7.SDR SWAA2022102451971Panel · damagedPANEL 323CL HAS ELONGATED FASTENER HOLE ON FWD END. / [01] REMOVED PANEL 323CL DUE TO DAMAGE.;[02] REPAIRED PER EA 22-155-03124 (SWA - REPAIR - VERTICAL STAB AFT CLOSEOUT PANEL 323CL PN 172A6124-11 FASTENER HOLE DAMAGE ON PN: 176A1000-46; SN: XA003412 ON A/C 8SDR SWAA2022102452363Floor Support · crackedFLOOR SUPPORT INTERCOSTAL AT BS 540 LBL1 WL 208 IS CRACKED AT FASTENER HOLE. / [01] REMOVED AND REPLACED PANEL PER SRM 51-40-02.SDR SWAA2022091974465Hook · out of adjustFA REPORTS FWD ENTRY DOOR GIRT BAR STOWAGE HOOK IS LOOSE / [01] ADJUSTED GIRT BAR STOWAGW HOOK IAW S.I.P. <BR>OPS CHECK GOODSDR SWAA2022040489171Strip · shearedAFT CARGO BULKHEAD SHROUD BOTTOM CAPSTRIP DAMAGED AND SHEARED / [01] INSTALLED NEW CAPSTRIPS PER AMM 25-52-18.