N851UA
Service difficulty reports · 88
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N851UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N851UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014022190408Warning System · false activationCIDS CAUTION LIGHT ILLUMINATED. TOMC RESET, NO HELP. RETURN TO GATE, CIDS PANEL SHOWED NO FAULTS. CYCLED AIRCRAFT POWER & FAULT CLEARED.SDR CALA2013082690749Smoke Detector · faultyLAVATORY SMOKE DETECTOR FAULT ON ECAM CIDS FAULT LIGHT ON. DEFERRED IAW MEL. PLACARDED LAVATORY RECEPTACLE & LAVATORY DOOR. INSTALLED DF STICKER ADJUSTMENT TO CIDS PANEL. REMOVED & REPLACED LAVATORY SMOKE DETECTOR IAW AMM 26-17-15-000-001-A 26-17-00-710-001SDR CALA2013081990557Smoke Detector · false indicationSDCU STATUS MESSAGE. BITE CHECK OF SDCU NOT FAULTING ANY SMOKE DETECTORS. CHECKED CON AND WIRES AT AFT LAV 6WQ AND AFT CARGO BAY SMOKE DETECTOR 5WH. REPLACED SMOKE DETECTOR (6WQ) IN LAVATORY F IAW MM, OPS CHECKED GOOD. REPLACED AFT CARGO SMOKE DETECTORSDR CALA2013081990545Sdac · unknownCABIN PRESSURE 1 & 2 FAULT. R & R SDAC 1, ALL SYS TEST NORMAL.SDR CALA20130708003Screw · unsecureLEFT SIDE, BELOW OVERWING SLIDE PACK COVER, SCREW STICKING OUT. SECURED SCREW AS REQUIRED.SDR UALA2013070804755Screw · unsecureLEFT SIDE, BELOW OVERWING SLIDE PACK COVER, SCREW STICKING OUT. SECURED SCREW AS REQUIRED.SDR UALA2012123107481Wire Harness · damaged1ST CLASS CLOSET FWD INB POST RED EMERGENCY PATHWAY LIGHT WIRING HARNESS DAMAGED APPROX 15 IN FROM FLOOR LEVEL. REPLACED LIGHT. REPAIRED WIRING AND OPS CHECK GOOD.SDR UALA2012110606360Sensor · faultyPER CAPT: WHEN GEAR HANDLE SELECTED DOWN, GEAR HANDLE ARROWS SCROLLED, GEAR DOORS CONTINUOUS CYCLING ON ECAM, BOTH LGCIU'S SHOWED DISAGREE, 3 REDS FOR GEAR DOWN, THE N LGCIU 1 FAULT, ECAM PROMPT "GRAVITY GEAR EXTEND". EXTENDED GEAR MANUALLY, THEN 3 GREENS FORSDR UALA2012103106281Oxygen Bottle · low pressureCREW OXYGEN SYSTEM LOW. REMOVED CREW O2 BOTTLE AND SERVICED TO 1500 PSI. REINSTALLED CREW O2 BOTTLE, NO LEAKS NOTED.SDR UALA2012080604208Lens · brokenDOOR 2R EMERGENCY EXIT SIGN, LENS BROKEN AND WILL NOT STAY IN PLACE. REPLACED LIGHT ASSY, OPS OKAY.SDR UALA2012041302248Acoustic Liner · damagedNR 2 ENGINE HAS A SMALL HOLE IN THE ACOUSTIC LINER OF THE INLET AT THE 8 O'CLOCK POSITION. HOLE IS LESS THAN 1/4 INCH AND LESS THAN .375 IN DEPTH AND PER MT.SDR UALA2012040402082Motor · failedCAPTAIN'S WINDSHIELD WIPER WILL NOT SHUT OFF. REMOVED AND REPLACED WINDSHIELD WIPER MOTOR, OPS CHECKED GOOD.SDR UALA2012033001982Slide · faultyONE LEFT SLIDE BATTERY PACK FAILED ON CIDS TEST. REPLACED SLIDE ASSY SLIDE ASSY IS SECURED ON DOOR, INFLATION CYL SAFETY PIN IS REMOVED AND STOWED, DOOR ASSIST BOTTLE STRICKER LEVER IS IN ARMED POSITION AND SAFETIED, EMERGENCY LIGHTS TEST OK. ACFT RETURNED TSDR UALA2012011200268Power Supply · failedEMERGENCY LIGHTS FAIL TEST. REPLACED EPSU 12WL PER MM, OP CHECKED GOOD.SDR UALA2011101705627Exhaust Pipe · crackedNR 1 ENGINE EXHAUST CONE HAS A 13 INCH CRACK. REPLACED NR 1 ENGINE EXHAUST CONE PER AMM.SDR UALA2011090904878Drain Valve · leakingBAD SMELL FROM PACKS DURING DESCENT FROM 5000FT DOWN TO TOUCHDOWN. ACCOMPLISHED ENG RUN, LET PACKS RUN, UNABLE TO DUPLICATE ON GROUND. PROBLEM RECURRED TWO SEGMENTS LATER. FOUND FUEL LEAKING AT THE FUEL DRAIN VALVE CENTER TANK RT SIDE PNL 196BB AREA, RESET SDR UALA2011090704849Structure · damagedLIGHTNING STRIKE DAMAGE TO FUSE 13 HITS LT FUSE FWD OF WING TAIL INSP CW REQ RR IF STATIC WICK, DIVERTER, STROBE LENS. PARTS IN STOCK. LENS STILL NEEDS REPLACE. FINISHING UP REPAIRS. ACCOMPLISHED REPAIRS TO DAMAGED AREAS.SDR UALA2011012500408Aileron Sys · out of rigACFT IN LEVEL FLT SYMMETRICAL EPR AND FUEL IS BALANCED. TRIM L2.5. FOUND ALL 4 AILERON NEUTRALS OUT OF LIMITS. ADJUSTED TO ALL 4 IAW MM. REMOVED FLIGHT DECK PINS, OPS CHECKED OK.SDR UALA2010122204686Inlet · damagedCREW REPORT: NR 2 ENG COWL INLET HAS CHUNK MISSING. SAMC TEXT: PLEASE IDENTIFY LOCATION, SIZE OF "CHUNK" (INCLUDING LENGTH WIDTH AND DEPTH) AND WHAT TYPE OF MATERIAL IS MISSING. DIMENSIONS OF AREA ARE IN QUESTION ARE 1.25 WIDE BY 0.75 LONG, BY .325 DEEP. OK TSDR UALA2010052801841Terminal · burnedBURNING ELECTRICAL ODOR COMING FROM AFT GALLEY OVERHEAD. ODOR WENT AWAY AFTER TURNING COFFEEMAKERS & AFT CHILLERS OFF. REMOVED & INSPECTED COFFEEMAKERS. FOUND BURNED WIRE TERMINAL AT BOTTOM OF HOT PLATE ON C-M M42. NO DEFECTS WITH BENCH PLUGS OR REMAINING COFSDR UALA2010052601806Unknown · odorF/A REPORT ELECT BURNING SMELL IN AFT GALLEY. STOPPED W- GAL PWR OFF. NEED TO CHECK OVEN INTERIOR FOR CHARRING IN FAN. WITH ACFT DE-ENERGIZED, OPEN TRIANGLE PANEL WHERE GALLEY POWER SWITCHES ARE LOCATED, INSPECT FOR CHARRING. INSPECTED AFT GALLEY ELECTRICAL CSDR UALA2009111003512Smoke Detector · inoperativeDOOR 2L AFT LAVATORY SMOKE DETECTION SYSTEM(S) INOPERATIVE. REPLACED SMOKE DETECTOR AT 2L AFT LAV, CFDS TEST CHECK GOOD.SDR UALA2009052101449Fitting · stuckDOOR 1L GIRT BAR RETAINING CLIP ON FLOOR STUCK IN OPEN POSITION. CLEANED AND LUBRICATED GIRT BAR AFT FLOOR RETAINING CLIP, SPRING CHECKS OK.SDR UALA2009041001033Battery Pack · inoperativeDURING 3 SVC CHECK EMERG LIGHTS TEST SHOWS EPSU BATTERY EMERG RT AND EPSU BATTERY EMER LT AFTER TEST. REPLACED LEFT EMERGENCY POWER SUPPLY UNIT AND RIGHT EPSU BATTERY PACK. EMERGENCY LIGHTS TEST NORMAL.SDR UALA2009040800999Power Supply · faultyEPSU UNIT EMERGENCY L MSG ON EMERGENCY TEST. REPLACED EPSU AT EMERGENCY EXIT DOOR LEFT, TEST PASSED ON EPSU, BUT EPSU AFT L IS NOW DISPLAYED AFTER EMERGENCY TEST. REPLACED AFT POWER SUPPLY UNIT AND BATTERY, (12WL) AND FWD PSU BATTERY (10WL), SYS TEST OK.SDR UALA2009022300608Fmu · malfunctionedNR 1 ENG EGT EXCEEDANCE REPORTED BY FLT CREW. ENG FIRE BOTTLES DISCHARGED DURING SHUTDOWN. PER ENG UNUSUAL REPORT, EXCEEDANCE WAS 662 DEG FOR 2 SECONDS. REPLACED FMU.SDR UALA2009021700522Light · inoperativeEEL LIGHT AT SEAT ROW 14 ABC, IS INOP. REPLACED EEL ASSY P/N BR9 644-21, OPS CHECKED GOOD.SDR UALA2009010200004Sensor · shortedECAM ANTI-ICE CAPT PITOT. FLIGHT DIVERTED. FOUND SENSOR 21GA SHORTED. REPLACED SENSOR AND ACCOMPLISHED GEAR SWING AND CFDS TEST AND SYS CHECKED NORMAL.SDR 2008UALA02172Light · looseEMERGENCY EXIT LIGHT ON EXTERIOR OF FIRST CLASS CLOSET IS LOOSE. SECURED EXIT LIGHT.SDR 2008UALA01301Fire Bottle · blownNR 1 ENG NR 1 BOTTLE INADVERTENTLY BLOWN DURING HMV VISIT. ACCIDENTAL DEPLOYMENT OF FIRE BOTTLE. REPLACED BOTTLE AND CLEANED AREA.SDR 2008UALA00309Harness · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). BROKEN HARNESS (LEAKING). REPLACED F/O'S O2 HARNESS.SDR 2007UALA05384Skin · dentedBIRD STRIKE ON NR 3 SLAT ON LEFT WING, DENT MEASURES 6 X 3.5 (CHORDWISE), APPROX 0.5 INCH DEEP. LOCATED 0.31 25 INCHES FROM RIB RIVETS. REPAIRED NR 3 L/E SLAT WITH AN INSERT REPAIR AND PERFORMED BIRD STRIKE INSPECTION OF WHOLE A/C, NO FURTHER DAMAGE WAS NOTESDR 2007UALA03782Oxygen Mask · unwanted deployTHE 11 DEF OXYGEN MASKS DEPLOYED ON LANDING.SDR 2007UALA03781Oxygen Mask · unwanted deployOXYGEN MASKS AT 2AB DEPLOYED ON TAKEOFF.SDR 2007UALA00094Wire Harness · misroutedDOOR SLIDE 1R HAS INCORRECT ROUTING OF ELECTRICAL HARNESS. HARNESS RUNS AFT, AWAY FROM DOOR SUPPORTS. ROUTED ELECTRICAL HARNESS IN CORRECT DIRECTION.SDR 2007UALA00093Wire Harness · misroutedDOOR SLIDE 1L HAS INCORRECT ROUTING OF ELECTRICAL HARNESS. ROUTED ELECTRICAL HARNESS IN CORRECT DIRECTION.SDR 2005UALA01073Skin · bird strikeBIRD STRIKE DAMAGE AT FRAME 5 AT TO TOP OF RVSM AREA. *S/D* INST REPAIR DOUBLERS AND FRAME FLANGES PER SRM 53-11-11 AND UA-EVA-50672.SDR 2002UALA01069Proximity Switch · looseRETURNED TO FIELD DUE TO A DOOR AFT CARGO ECAM WARNING. INSPECTED DOOR SENSOR AND TARGET, CHECKED SYSTEM THROUGH CFDS.CFDS FAULTED PROX SWITCH 32WV. FOUND PROX SWITCH LOOSE. CLEANED THE SWITCH AND SECURED. OPENED AND CLOSED DOOR SEVERAL TIMES, INDICATION