N852UA
Service difficulty reports · 96
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N852UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N852UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013122693941Heat Shield · damagedDURING A CHECK FOUND ENG NR 2 RT SLEEVE HEAT SHIELD MISSING ONE PIECE TE 12 INCHES LONG. R & R AFT HEAT SHIELD & AFT CLOSURE AT NR 2 ENG RT C DUCT IAW V2500 CMM 78-30-00 REP 036. ALL NORMAL AFTERWARDS.SDR CALA2013101892185Pump · overheatedHYD B ELEC PUMP OVERHEATED AT CRUISE. REPLACED BLUE ELEC HYD PUMP IAW AMM, OPERATIONS TESTED NORMAL.SDR CALA2013080590170Liner · missing1.5 INCH AREA OF ACCOUSTIC MATERIAL IN NR 2 ENGINE NACELLE, MISSING. ATTRITION LINER AT 6 O'CLOCK POSITION HAS A 1.5" X BY 1.750" PIECE MISSING FROM NR 2 ENG. REPAIR MUST BE ACP WITHIN 20 CYCLES MT 72-017.SDR UALA2013071004820Warning Message · false indicationAVIONICS SMOKE ECAM MESSAGE ILLUMINATED. NO VISIBLE SMOKE OR FUMES. REPLACED AEVC COMPUTER AND OPS CHECKED OK. NO FAULTS.SDR UALA2013062604442Cone · crackedCRACK IN TAIL CONE OF LEFT ENGINE. REPLACED THE NR 1 ENGINE EXHAUST CONE IAW AMM.SDR UALA2013061804210Liner · damagedNR 2 ENG FAN CASE ATTRITION LINER HAS MISSING MATERIAL AT THE 6 O'CLOCK POSITION. ACCOMPLISHED ATTRITION LINER REPAIR, REF MT 72-017.SDR UALA2013050703214Paint · damagedBIRD STRIKE ON APPROACH. FOUND DAMAGE TO WEAR ABRASION RESISTANT PAINT ON LEFT WING OTBD FLAP INBD LEADING EDGE NEAR INBD FLAP FAIRING. NO OTHER DAMAGE NOTED.SDR UALA2013050203070Contactor · defectiveBCL 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. ELEC ECAM MSG CAME ON INTERMITTENTLY. CFDS ATA 243800 CHECK CONTACTOR 6PB2-BCL2 CIRCUIT. ID:BCL2. REFER TO TSM24-38-00-810-813-A, FAILURE OF THE BATTERY 2 CONTACTOR PSBL CAUSES: 6PB2 565-0010, 1PB2 565-0073. REPLSDR UALA2013032501843Oxygen Bottle · emptyO2 BOTTLE ABOVE 34C DEPLETED. REPLACED PORTABLE O2 BOTTLE ABOVE 34C IAW GMM. REPLACED MASK. OK TO CONTINUE.SDR UALA2013013100583Warning Message · false activationMAINTENANCE STATUS MESSAGE CIDS 1 DISPLAYED ON THE LOWER ECAM SCREEN. NO MESSAGE ON ECAM FOR CIDS PERFORMED BITE TEST OF CIDS SYSTEMS, NO FAULTS NOTED.SDR UALA2013013000566Oxygen Mask · unwanted deployO2 PANEL ROW 8 DROPPED DOWN. PERFORMED OPERATIONAL CHECK OF MANUAL MASK RELEASE IAW AMM TASK 35-23-00-710-001-A. ALL DOOR LATCHES OPERATE NORMAL, NO DEFECTS NOTED.SDR UALA2013012400406Battery Pack · warning messageEPSU BATTERY FWD LT MESSAGE APPEARED DURING CABIN EMERGENCY LIGHT TEST. REPLACED BATTERY PACK AND MESSAGE CLEARED.SDR UALA2012111906665Spinner · crackedNR 1 ENGINE NOSE SPINNER FOUND CRACK NEAR BOLT. REPLACED NR 1 ENGINE INLET CONE FAIRING PER AMM.SDR UALA2012071203779Battery · faultyPOST SLIDE REPLACEMENT TEST OF EMERGENCY LIGHTS REVEALED "EPSU RIGHT" MESSAGE. REPLACED EPSU AND BATTERY.SDR UALA2012070303553Skin · dentedLEFT INBD FLAP HAS BOWLING PIN SHAPED DENT 36 INCHES FROM INBOARD EDGE. DENT IS 8.50 INCHES LONG AND 7.25 INCHES WIDE AND MEASURES .25 INCHES DEEP. AFTER FURTHER EVALUATION PER MM DAMAGE IS OUT OF SERVICEABLE LIMITS. STARTED REMOVAL OF LT INBD FLAP PER AMM.SDR UALA2012051602781Engine · stalledSTALL DISPLAYED ON UPPER ECAM SCREEN DURING POWER DECELERATION. REMOVED PLUGS "B" AND "C" AND DRIVE PAD COVER, COMPLETED BORO OF HPC STG 3 AND 6 NO DAMAGE NOTED. REPLACED 7B SOLENOID VALVE, AND HPC 7TH STAGE BLEED VALVE DUE TO FAILED FUNCTIONAL TEST.SDR UALA2012051002686Engine · making metalCREW ADVISES "ENG OIL CLOG WITH VIBRATION" DIVERTING TO DEN. CREW DECLARED EMERGENCY WITH ATC. NR 2 MASTER CHIP DETECTOR HAS LARGE AMOUNT OF METAL ON IT. REPLACED NR 2 ENGINE REF MT71-017. AFTER ENGINE CHANGE, IDLE LEAK CHECK FOUND FLUID DRIPPING FROM COWLINSDR UALA2011101705602Connector · looseEMERGENCY LIGHTS FAIL TEST. SHOWS EPSU BATTERY AFT L ATA 33-51-38. CYCLED CONNECTOR AT AFT EPSU. OPS CHECKED NORMAL.SDR UALA2011012600427Interphone · inoperativeCAPTS O2 MASK INTERPHONE INOPERATIVE. REPLACED O2 BOX, OPS GOOD.SDR UALA2010102503926Valve · faultyCABIN TEMP ISSUE, RTFL. PFR SHOWING TRIM AIR PRESS VALVE, CREW REPORTED ONLY TEMP WAS PROBLEM, NO CABIN PRESSURE OR PACK FAULT. REPLACED TRIM VALVE PER AMM. TESTED OKAY. ALSO CHK'D PACK'S IAW MAINT TIP, ALL OPS NORMAL.SDR UALA2010100403673Access Panel · leakingLT WING HAS FUEL RUNNING OUT OF DRY BAY HOLE AT RIB 6. OPENED ACCESS PANEL 521AZ LEAK APPEARS TO BE COMING FROM LT TANK. LOCATED SOURCE OF LEAK, SEALED AT 1500-02, ACCOMPLISHED LEAK CHECK, NO ACTIVE LEAKS NOTED.SDR UALA2010052601802Unknown · odorCABIN CREW REPORTS STRONG CHEMICAL SMELL IN LAST FEW ROWS OF COACH AND GALLEY. CHECKED GALLEYS, COFFEEMAKERS AND CHILLERS, OVENS, CHECKED UNDER SEATS, CHECKED LAVS AND CGO PITS, OPERATED PACKS WITH APU BLD, CHECKED LIGHTS, NO UNUSUAL SMELL OR ODOR NOTED. ALL CSDR UALA2010041901282Unknown · odorACRID ODOR IN FWD GALLEY, FLIGHT DIVERTED. ACCOMPLISHED THOROUGH VISUAL CHECK OF GALLEY COMPARTMENTS. AVIONICS COMPARTMENT, AVIONICS COOLING SYS AND CABIN. ONLY FOUND DRY ICE CONTAINER BAGS OPENED AND TORN, THERE WERE NO DEFECTS IN ANY SYS WHICH INCLUDED THESDR UALA2010020100382Smoke Detector · false activationSMOKE LAV DET FAULT ECAM DISPLAY. REPLACED LAV A SMOKE DETECTOR. ALL TESTS PASS.SDR UALA2010012500294Smoke Detector · false activationSMOKE LAV DET FAULT ECAM AND STATUS MSG. REPEAT GRIPE. REPLACED SMOKE DETECTOR IAW MM 26-17-15.SDR UALA2009112303632Lamp · inoperativeLT OVERWING EMERGENCY LIGHT INOP LT ASSY BULB BURN'T OUT INOP. RELAMP AND RE-INSTALL LENS, OPS CHECK GOOD.SDR UALA2009102603329Battery · failedEMERGENCY LIGHT TEST FAILS FOR L OVERWING BATTERY. REPLACED L OVERWING EPSU BATTERY, OP CHK'D OKAY.SDR UALA2009101403229Oxygen Mask · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). REPLACED OXYGEN MASK, OP CHECKS GOOD.SDR UALA2009050101268Skin · damagedDAMAGE IS LOCATED 3 INCH AFT OF FRAME 21 AND 4 .5 INCH UP FROM STRINGER 21 DEPTH .200 INCH 7-8TH WIDE BY 1 INCH LONG. FOUND CRACK AND DAMAGE. LOCATION OF DAMAGE IS AFT OF FWD ENTRY DOOR RT SIDE. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA PRIOR TO ABOVSDR UALA2009042701199Filter · dirtyODD BURNING PLASTIC AND VINEGAR SMELL WITH IRRITATION TO THE EYES IN COCKPIT. CHECKED AVIONIC VENT FAN FILTER. FILTER DIRTY REPLACED FILTER, CHECKED BEHIND ALL C/B PANELS NO DEFECTS. OPENED CAPTAINS SLIDING WINDOW FOUND BOTTLE OF WINDSHIELD CLEANER IN WINDOSDR UALA2009012600280Ram Air Turb · unwanted extendRAT DEPLOYED IN FLIGHT, JUST AFTER LEVELING OFF AT ALT. WILL NEED TO REPLACE RAT AND ACP FULL OPS TEST. STARTING REMOVAL. NEW RAT ON SITE. REPLACED RAT. ACCOMPLISHED MAN DEPLOYMENT AND STOW TEST NEED FUNCTIONAL CHECK. CREW REPORTS THE RAM AIR TURBINE IS SDR 2008UALA03419Light · missingEMERGENCY EXIT LIGHTING AT 1L IS MISSING - BROKEN. FWD CLOSET DIVIDER AT DOOR 1L MISSING AISLE LENS CAP AND LAMP.SDR 2008UALA03418Oxygen System · low pressureCREW O2 LEVEL LOW.SDR 2008UALA03268Bottle · low pressureCREW REPORT: DOOR 2R DOOR ASSIST BOTTLE PRESSURE LOW.SDR 2008UALA02429Oxygen Mask · unsecureO2 MASKS AT SEAT 10DEF WILL NOT STOW. DUE TO REPEAT REPACKINGS, REPLACED THE COMPARTMENT WITH REPACKED O2 MASKS.SDR 2008UALA00859Slide · faultyLT OFFWING SLIDE HAS DELAMINATION FOUR INCHES LONG AT AFT EDGE IN AREA. REPLACED LT OVERWING SLIDESDR 2007UALA04402Structure · dentedCREW REPORTS EVIDENCE OF BIRDSTRIKE ON LT WING INBOARD OF ENG WITH SIGNIFICANT DENT. NR 1 L/E SLAT LT WING DENT MEASURES .46875 DEEP, 3.5 WIDE AND 5.25 LONG, OUT OF LIMITS. REPLACED NR 1 LE SLAT.SDR 2007UALA03508Cylinder · low pressureNR 2 RIGHT PASSENGER DOOR EMERGENCY CYL-ACCUM PRESSURE LOW. SERVICE DOOR ASSIST CYLINDER TO PROPER PRESSURE,SDR 2007UALA03120Lens · brokenSEAT 11C EMERGENCY ESCAPE PATH RED LIGHT LENSE BROKEN. REPLACED THE LENS.SDR 2007UALA02943Warning System · malfunctionedCREW COMMENTS: LANDING GEAR SYSTEM DISAGREE ECAM UPON LANDING, WENT AWAY AFTER 30 SECONDS. REPLACED PROX SENSOR 29GA AND LGCIU2. NO REPEATS SINCE ORIGINAL.SDR 2007UALA01275Battery · faultyDURING 3 SVC EMERGENCY LIGHT CHK, AFT POWER SUPPLY BATTERY FAULTED. [SUP 05-16-07] REPLACED BATTERY, TESTED OK.SDR 2006UALA00669Bottle · low pressureESCAPE SLIDE AT DOOR 2R PRESSURE IN THE RED. AMIS HISTORY REPORT SHOWS A SERIES OF EVENTS WITH THE 2R DOOR SLIDE BOTTLE PRESSURE HAVING A LOW PRESSURE READING. ON 4/1/2006 AT ORD, THE PRESSURE HAD A LOW READING BUT WAS WITHIN LIMITS. ON THE SAME DAY AT ORD,SDR 2006UALA00621Battery · failedEPSU BATTERY EMERGENCY L FAIL MSG ON 3 SERVICE EMERGENCY LIGHTS TEST. REPLACED BATTERY POWER SUPPLY. OPS TESTED GOOD.SDR 2006UALA00093Wire · damagedPATH GUIDE EMERGENCY LIGHTS OUT AT SEATS 19 & 20. FOUND WIRES RIPPED OUT OF CONNECTOR PLUG TO WALL AT ROW 19. THE CONNECTOR PLUG WAS ALSO MISSING BACK SHELL. PER UA-EVA-60002 SPLICED WIRE TOGETHER AROUND CONNECTOR 7260VC8 AND 7260VC8-A. CONNECTOR 7260VC8 STSDR 2005UALA00340Proximity Sensor · failedGEAR NOT DOWN AND LOCKED ECAM DISPLAYED. MANUAL EXTENSION WAS SUCCESSFUL. FAULTY SENSOR FIN 34GA. GEAR EXTENDED MANUALLY. REPLACED PROX SENSOR 34GA.SDR 2004UALA01177Light · damagedDURING OVERHAUL EMERGENCY EXIT SLIDE LIGHT WERE FOUND TO BE DAMAGED. SUPPLEMENTAL DATA UPDATE THE LIGHT ASSEMBLY WAS REPLACED.
Back to N852UA