N8530W
Service difficulty reports · 117
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8530W' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8530W' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023041917569Web · corrodedAFT CARGO DOOR CUTOUT LOWER THRESHOLD WEB HAS CORROSION.<[01] REMOVED DAMAGE OF .012IN OF MATERIAL. REMAINING THICKNESS OF .038IN. ORIGINAL THICKNESS OF .050IN. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. SO REQUIRES REPLACEMENT.;[02] REMOVED AFT CARGO DOSDR SWAA2023041917568Angle · corrodedAFT CARGO R/H TRANSITION ANGLE JUST FWD OF CARGO DOOR OPENING HAS CORROSION.<[01] REMOVED DAMAGE. MATERIAL REMOVED WAS .012IN. REMAINING IS .038IN. ORIGINAL THICKNESS WAS .050IN. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED AFT CARGO R/H TRANSSDR SWAA2023041917579Angle · corrodedAFT CARGO R/H TRANSITION ANGLE STA 867+6 ON SMALL TRANSITION ANGLE HA CORROSION.<[01] REMOVED AFT CARGO R/H TRANSITION ANGLE STA 867 + 6 TO FOM;[02] REMOVED DAMAGE. MATERIAL REMOVED IS .006IN. REMAINING MATERIAL IS .044IN. ORIGINAL THICKNESS OF .050IN. FOUND TSDR SWAA2023041917566Angle · pulledAFT CARGO R/H TRANSITION ANGLE HAS FASTENER PULLED THROUGH STA 727E AT FRAME.< REMOVED TRANSITION ANGLE PER SRM 51-40-02.;[02] REMOVED RIVET. RIVET WAS PULLED THROUGH DUE TO CORROSION AROUND FASTENER. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;CUT AND RESDR SWAA2023041917565Angle · corrodedAFT CARGO L/H TRANSITION ANGLE CORROSION AROUND FASTENER HOLE STA 727D +4<[01] DID NOT REWORK THIS CORROSION DUE TO THIS SECTION IS BEING REPAIRED ON NR # (TTG8Q00JWK6V).;[02] NEW L/H TRANSITION ANGLE FROM 727+4? TO 847 AND REPAIR SPLICE PLATES TO BE FABRICATESDR SWAA2023041917572Angle · corrodedAFT CARGO L/H TRANSITION ANGLE CORROSION FROM STA 727F THRU STA 847.<[01] REMOVED L/H TRANSITION ANGLE PER SRM 51-40-02 TO FOM;[02] REMOVED DAMAGE OF .010IN OF MATERIAL. REMAINING THICKNESS OF .040IN. ORIGINAL THICKNESS OF .050IN. FOUND TO BE OUT OF LIMITS PERSDR SWAA2023041917573Angle · corrodedAFT CARGO R/H TRANSITION ANGLE CORROSION FROM STA 727F THRU STA767.<[01] REMOVED TRANSITION ANGLE PER SRM 51-40-02.;[02] REMOVED L/H TRANSITION ANGLE PER SRM 51-40-02 TO FOM;[13] INSTALLED R/H TRANSITION ANGLE PER SRM 51-40-02;[14] CORRECTION FOR LINE 13; INSTSDR SWAA2023041917577Angle · corrodedAFT CARGO R/H TRANSITION ANGLE JUST AFT OF CARGO DOOR CUTOUT HAS CORROSION.<[01] REMOVED DAMAGE. MATERIAL REMOVED IS .015IN. REMAINING THICKNESS OF .035IN. ORIGINAL THICKNESS OF .050IN. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] LOCATED AND DRILLED SDR SWAA2023042016850Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241UF<[01] REMOVED AND REPLACED PASSENGER CABIN FLOOR PANEL 241UF PER AMM 53-21-00.;[02] INSPECTION C/WSDR SWAA2023042016846Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241VF<[01] INSTALLED FLOOR PANEL 241VF I.A.W. AMM 53-21-00.;[02] VERIFIED C/A #1.SDR SWAA2023042016845Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 242PF<[01] INSTALLED FLOOR PANEL 242PF I.A.W. AMM 53-21-00.;[02] VERIFIED C/A #1.SDR SWAA2023042016844Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 242QF<[01] INSTALLED FLOOR PANEL 242QF I.A.W. AMM 53-21-00;[02] VERIFIED C/A #1.SDR SWAA2023042016843Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241F<[01] REMOVED AND REPLACED FLOOR PANEL 241F PER AMM 53-21-00. REFERRED TO TASK # TTG8Q00HC98Z FOR WORK ACCOMPLISHED. TORQUE WRENCH # T000023 S/N 920183.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTIONSDR SWAA2023042016842Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241E<[01] REMOVED AND REPLACED FLOOR PANEL 241E PER AMM 53-21-00. REFERRED TO TASK # TTG8Q00HC993 FOR WORK ACCOMPLISHED. TORQUE WRENCH # T000023 S/N 920183.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTIONSDR SWAA2023042016835Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 241YF<[01] REPLACED WITH NEW PANEL; INSTALLATION ACCOMPLISHED ON TTG800HCA69.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023042016833Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 241XF<[01] REPLACED WITH NEW PANEL; INSTALLATION ACCOMPLISHED ON TTG800HC98P.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916846Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241VF<[01] INSTALLED FLOOR PANEL 241VF I.A.W. AMM 53-21-00.;[02] VERIFIED C/A #1.SDR SWAA2023041916847Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241WF<[01] INSTALLED FLOOR BOARD PANEL 241WF I.A.W. AMM 53-21-00;[02] VERIFIED C/A #1.SDR SWAA2023041916845Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 242PF<[01] INSTALLED FLOOR PANEL 242PF I.A.W. AMM 53-21-00.;[02] VERIFIED C/A #1.SDR SWAA2023041916850Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241UF<[01] REMOVED AND REPLACED PASSENGER CABIN FLOOR PANEL 241UF PER AMM 53-21-00.;[02] INSPECTION C/WSDR SWAA2023041916833Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 241XF<[01] REPLACED WITH NEW PANEL; INSTALLATION ACCOMPLISHED ON TTG800HC98P.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916843Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241F<[01] REMOVED AND REPLACED FLOOR PANEL 241F PER AMM 53-21-00. REFERRED TO TASK # TTG8Q00HC98Z FOR WORK ACCOMPLISHED. TORQUE WRENCH # T000023 S/N 920183.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTIONSDR SWAA2023041916834Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 242RF<[01] REPLACED WITH NEW PANEL; INSTALLATION ACCOMPLISHED ON TTG800HCAGT.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916835Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 241YF<[01] REPLACED WITH NEW PANEL; INSTALLATION ACCOMPLISHED ON TTG800HCA69.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916836Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 242D<[01] REPLACED WITH NEW PANEL; INSTALLATION TO BE ACCOMPLISHED ON TTG8Q00HC98H.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916837Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241AAF<[01] REPLACED WITH NEW PANEL; INSTALLATION TO BE ACCOMPLISHED ON TTG8Q00HC99H.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916844Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 242QF<[01] INSTALLED FLOOR PANEL 242QF I.A.W. AMM 53-21-00;[02] VERIFIED C/A #1.SDR SWAA2023041916842Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241E<[01] REMOVED AND REPLACED FLOOR PANEL 241E PER AMM 53-21-00. REFERRED TO TASK # TTG8Q00HC993 FOR WORK ACCOMPLISHED. TORQUE WRENCH # T000023 S/N 920183.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTIONSDR SWAA2023041916816Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 221AF<[01] FLOOR PANEL 221AF IS BEING REPLACED WITH A NEW FLOOR PANEL AND IS BEING INSTALLED ON THE 221AF CLOSE CARD ON LINE 2013.;[02] THE LINE NUMBER FOR PANEL 221AF CLOSE ON THE PREVIOUS SIGNOFF IS ISDR SWAA2023041916817Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 221BF<[01] FLOOR PANEL 221BF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 221BF CLOSE CARD ON LINE 1136.;[02] VERIFIED.SDR SWAA2023041916818Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 222BF.<[01] FLOOR PANEL 222BF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 222BF CLOSE CARD ON LINE 420.;[02] VERIFIED.SDR SWAA2023041916838Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241ABF<[01] REMOVED AND REPLACED FLOOR PANEL 241ABF PER AMM 53-21-00. REFERRED TO TASK # TTG8Q00HC99F FOR WORK ACCOMPLISHED. TORQUE WRENCH # T000023 S/N 920183.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACSDR SWAA2023041916819Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 221CF<[01] FLOOR PANEL 221CF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 221CF CLOSE CARD ON LINE 1134.;[02] VERIFIED.SDR SWAA2023041916820Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 221EF<[01] FLOOR PANEL 221EF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 221EF CLOSE CARD ON LINE 1130.;[02] VERIFIED.SDR SWAA2023041916839Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241ZF<[01] REPLACED WITH NEW PANEL; INSTALLATION ACCOMPLISHED ON TTG800HCASM.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916821Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 221EF<[01] FLOOR PANEL 221EF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 221EF CLOSE CARD ON LINE 1130.;[02] VERIFIED.SDR SWAA2023041916840Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 241D<[01] REPLACED WITH NEW PANEL; INSTALLATION TO BE ACCOMPLISHED ON TTG8Q00HC997.;[02] PER AMM 53-21-00;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041916822Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 221F<[01] FLOOR PANEL 221FF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 221FF CLOSE CARD ON LINE 1128.;[02] VERIFIED. PANEL 221FF.SDR SWAA2023041916823Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 232BF<[01] FLOOR PANEL 232BF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 232BF CLOSE CARD ON LINE 798.;[02] VERIFIED.SDR SWAA2023041916824Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 232AF<[01] FLOOR PANEL 232AF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 232AF CLOSE CARD ON LINE 800.;[02] VERIFIED.SDR SWAA2023041916825Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 231AF<[01] FLOOR PANEL 231AF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 231AF CLOSE CARD ON LINE 1116.;[02] VERIFIED.SDR SWAA2023041916826Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 231CF<[01] FLOOR PANEL 231CF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 231CF CLOSE CARD ON LINE 1112.;[02] VERIFIED.SDR SWAA2023041916827Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 222AF.<[01] FLOOR PANEL 222AF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 222AF CLOSE CARD ON LINE 422.;[02] VERIFIED.SDR SWAA2023041916828Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 221DF<[01] FLOOR PANEL 221DF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 221DF CLOSE CARD ON LINE 1132.;[02] VERIFIED.SDR SWAA2023041916829Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 222DF<[01] FLOOR PANEL 222DF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 222DF CLOSE CARD ON LINE 1122.;[02] VERIFIED.SDR SWAA2023041916830Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 222CF<[01] FLOOR PANEL 222CF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 222CF CLOSE CARD ON LINE 1124.;[02] VERIFIED.SDR SWAA2023041916831Floor Panel · delaminatedPASSENGER CABIN FWD WET AREA FLOOR PANEL HAS DELAMINATION 231BF<[01] FLOOR PANEL 231BF IS BEING REPLACED WITH A NEW PANEL AND IS BEING INSTALLED ON THE 231BF CLOSE CARD ON LINE 1114.;[02] VERIFIED.SDR SWAA2023041916832Floor Panel · delaminatedPASSENGER CABIN AFT WET AREA FLOOR PANEL HAS DELAMINATION 242SF<[01] REPLACED WITH NEW PANEL; INSTALLATION TO BE ACCOMPLISHED ON TTG8Q00HCAGR.;[02] PER AMM 53-21-00.;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023041917113Angle · corrodedAFT SERVICE DOOR Z ANGLE HAS CORROSION AT STATION 967 +9 (MARKED)<[01] AFT SERVICE DOOR Z ANGLE HAS CORROSION AT STATION 967 +9 ; STATION LOCATION WAS WRITTEN IN ERROR SEE FAULT TTG8Q00JVC1T FOR CORRECTED LOCATION.;[02] VERIFIED NEW FAULT GENERATED WITH CORRECSDR SWAA2023041917115Tie Down · corrodedAFT GALLEY TIE DOWN AT STATION 967 +18 RBL 53 HAS CORROSION (MARKED)<[01] AFT GALLEY TIE DOWN AT STATION 967 +18 RBL 53 HAS CORROSION; STATION LOCATION WAS WRITTEN IN ERROR SEE FAULT TTG8Q00JV91U FOR CORRECTED LOCATION.;[02] VERIFIED NEW FAULT GENERATED WITH C