N854UA
Service difficulty reports · 96
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N854UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N854UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2015051193760Light · inoperativeEMERGENCY EXIT LIGHTS, FLOOR MARKING LIGHTS INOPERATIVE ROWS 23 & 24 LT, 27 & 28 LT, 31 & 32 LT. ROW 31 & 32 WERE DIM FOR 5 MINUTES THEN WENT OUT. REPLACED 11WL & RELAMPED ALL SEATS. OPERATIONS NORMAL.SDR CALA2015051193758Power Supply · inoperativeEMERGENCY LIGHT TEST FAILED ON NR 2 SVC. MSG IS EPSU INIT LOAD EMER LT. REPLACED POWER SUPPLY & BATTERY IAW MM 33 51 38.SDR CALA2015051193761Proximity Sensor · faultyAIR RETURN FOR LGCIU FAULT, L - G NO UPLOCK. REPLACED PROX SENSOR 25GA & NGL M2 HARNESS.SDR CALA2014091892245Skin · saturatedLEFT ELEVATOR UPPER SURFACE HAS WATER INGRESS AT THREE EACH LOCATIONS IN ZONE 3. REMOVED DAMAGE & REPAIRED IAW SRM 55-21-11 PARA 5 E FIG 205. REPAIR REQUIRES SRI INSPECTIONS IAW SRI 55-21-11-2-002-00 PARA 3 - B TABLE 203. FIRST INSPECTION DUE AT 48000FC & 6SDR CALA2014091892235Attach Fitting · corrodedFORWARD CARGO BILGE BELLY FAIRING ATTACH HAS CORROSION AROUND RIVETS ON SKIN FRAME 30 - 31 STRINGER 42L. CORROSION REMOVED IAW SRM 53-21-11DIAGRAM 105 PARA 4 E.SDR CALA2014091892234Door Sill · corrodedL2 DOOR SILL CORRODED BETWEEN STRINGER 22L & 23L AT FRAME 68. BLENDED CORROSION AT FRAME 68 ON L2 DOOR SILL BEAM IAW SRM 51-41-14 FIG 101. AFTER REMOVAL FOUND OUT OF LIMITS IAW SRM. R & R L2 DOOR SILL BEAM IAW SRM 51-72--11 PG 6 D & SRM 51-42-11 PARA 6 & 7.SDR CALA2014091292107Door Sill · corrodedR2 DOOR SILL HAS CORROSION FRAME 66 - 68 STRINGER 22R - 23R. DOOR SILL REPLACED IAW SRM 51- 42-11.SDR CALA2014081191931Chiller · overheatedAFT GALLEY CHILLER OVERHEATED IAW CREW VERBAL. CB'S PULLED THE CB PANEL AT GALLEY & COFFEE MAKERS WERE HOT & DID NOT COOL DOWN. EVENTUALLY CREW DESELECTED THE COMMERCIAL SWITCH & STILL DID NOT COOL. DEFERRED IAW MEL. DEACTIVATED CHILLER, PULLED & COLLARED SDR CALA2014010790058Apu · shutdownAPU AUTO SHUTDOWN TWICE FOR UNDETERMINED REASONS.SDR CALA2013100791782Connector · looseCABIN TO FLT DECK, FLT DECK TO CABIN FUNCTIONS INOPERATIVE AT ALL LOCATIONS. FOUND CONNECTOR 7460VC UNDER AFT FLIGHT ATTENDANT SEAT LOOSE & MAKING INTERMITTENT CONTACT. SECURED CONNECTOR IAW WDM 23-73-53 PA OPERATIONS CHECKED GOOD IN ALL LOCATION FWD, AFT ANSDR CALA2013092491382Panel · crackedFOUND LT INBD FLAP SLIDING PANEL CRACKED IAW FLAP TRUNNION INSPECTION MT 57-018. REPLACED LT INBD FLAP SLIDING PANEL IAW MT 57-018.SDR CALA2013090591040Battery · inoperativeEPSU BATTERY INOPERATIVE. REPLACED BATTERY IAW AMM.SDR UALA2013050703215Ptu · inoperativeWHILE TROUBLESHOOTING NOISE FOUND PTU INOP. REPLACED PTU REF AMM TASK 29-23-41-000-001-A.SDR UALA2013031901660Lens · looseR2 DOOR EXIT SIGN LOOSE. SECURED LOOSE LENS.SDR UALA2013022501116Fitting · not seatedFUEL LEAK LEFT WING NEAR WING ROOT. RESEATED LEFT WING INBOARD SUMP FITTING. NO FURTHER LEAK.SDR UALA2013022101054Loop · faultyREPLACE NR 1 ENGINE PYLON BLEED LOOP 1HF1 DUE TO LOW RESISTANCE READINGS. REPLACED LOOP, RAN ENGINE 5 MINS 2X NO FAULTS NOTED, NO RELATED PFR ISSUES.SDR UALA2013022101051Loop · faultyENGINE 1 BLEED LEAK DISPLAYED ON UPPER ECAM SCREEN. AIR CREW COMMENTS: ON ENGINE START GOT ENGINE 1 BLEED LEAK. MAINT TEXT: AC RETURNED TO GATE. FLT CREW STARTED ENGINES FOR TROUBLESHOOTNG. TWICE SAME MESSAGE: ENG1 BLEED LEAK ON ECAM. CFDS SHOWED NO CLASSDR UALA2012101205806Slide · crackedRIGHT OVERWING SLIDE PANEL IS CRACKED ON AFT EDGE. SLIDE REMOVED AND PUT IN REAR PIT ALSO SEAL ATTACH PLATE AND HARDWARE ARE IN PIT. INSTALLED SERVICEABLE OFF-WING SLIDE.SDR UALA2012080904335Stowage Box · malfunctionedCAP O2 MASK NOT OPERATING PROPERLY. REMOVED AND REPLACED CAPTAIN'S O2 MASK STOWAGE BOX, OPS OK.SDR UALA2012080604169Light · inoperativeCAPTAIN'S DOME LIGHT INOPERATIVE. RELAMPED, CAPTAINS OVERHEAD DOME LIGHT. OPS CHECKED GOOD .SDR UALA2012052903010Window · unsecurePAX INTERIOR WINDOW LOOSE 11F. SECURED WINDOW.SDR UALA2012012300442Battery Pack · faultyOVERWING EMERGENCY EXIT LIGHT IS FLASHING. REPLACED BATTERY PACK AT RT OVERWING DOOR. OPS NORMAL.SDR UALA2011120206629Actuator · failedCAPTAIN'S & FIRST OFFICER'S RUDDER PEDALS WILL NOT RELEASE AND EXTEND WHEN EXTENDED. REPLACED CAPTAIN'S RUDDER PEDAL ADJUSTER ACTUATOR.SDR UALA2011092305140Warning Message · false activationRIGHT TRANSFER VALVE OPEN DISPLAYED ON UPPER ECAM SCREEN. ACCOMPLISHED TSM TASK 28-15-00-810-829. TRANSFER VALVES PASSED FUNCTIONAL TESTS AND FLSCU STATUS REPORT TEST WITH NO FAULTS.SDR UALA2011091905056Amu · faultyF/O SMOKE MASK NO AUDIO. REPLACED F/O'S O-2 BOX & AUDIO MANAGEMENT UNIT, OPS CHECKS OKAY.SDR UALA2011091504990Skin · damagedDOZENS OF HAIL STRIKES ON LEADING EDGE OF LEFT HOZ STAB. ITEM ARCHIVED FOR VISIBILITY. NO OTHER MAINT ACTION REQUIRED.SDR UALA2011082204498Rudder Pedal · lack of lubeINITIALLY CAPTAIN'S RUDDER PEDALS STUCK IN FULL DOWN POSITION. NOW DOES NOT AUTO EXTEND WITH LEVER ON SPRINGS. LUBED PER AMM, OPS CHECK'S GOOD.SDR UALA2011053102669Servo · vibrationAIRFRAME VIBRATION BEGAN FL220 A-P DISC SET TRIM MANUALLY VIBRATION STOPPED. REQUESTED FLT CREW TO COMPLETE VIBRATION SURVEY. PLEASE TROUBLESHOOT ACFT USING TSM05-50-00-201. POSITIVE FIX REQUIRED BEFORE NEXT FLIGHT. REPLACED ALL RUDDER SERVO ROD ENDS.SDR UALA2011013100530Container · delaminatedLT OFFWING ESCAPE SLIDE CONTAINER AFT LOWER CORNER FOUND DELAMINATED BEYOND LIMITS AFTER SANDING FOR PAINT. REPLACED SLIDE REF AMM. SLIDE ASSY SECURED ON ACFT. INFLATION CYLINDER SAFETY PIN IS REMOVED AND STOWED IN POUCH, CONNECTOR IS SECURE, INFLATION LINSDR UALA2010091403412Oxygen Mask · no testCAPTAIN'S O2 MASK WILL NOT PRESS TO TEST. SWAPPED CAPTAIN'S AND 2ND OBSERVERS O2 MASK BOXES IAW AMM. CAPT'S MASK TESTS NORMAL, DEFERRED 2ND OBSERVERS SEAT IAW MEL 2511R.SDR UALA2009060901638Battery · dischargedDURING 3 SERVICE EMERGENCY LIGHT TEST FAILS EPSU FWD LEFT BATTERY. REPLACED FWD LEFT BATTERY. EMERGENCY LIGHT SYSTEM TESTS OKAY.SDR UALA2009031000687Window · leakingLOSS OF CABIN PRESSURE. FLIGHT DIVERTED. REPLACED FIRST OFFICERS WINDSHIELD.SDR UALA2009030200729Windshield · leakingLOSS OF CABIN PRESSURE. FLIGHT DIVERTED. F/O WINDSCREEN STARTED HISSING AND SQUEALING LOUDLY IN FLT. FL370. 8.0 PSI DIFF FROM TOP CTR. REPLACED FIRST OFFICERS WINDSHIELD.SDR UALA2009030200687Windshield · leakingLOSS OF CABIN PRESSURE. FLIGHT DIVERTED. F/O WINDSCREEN STARTED HISSING AND SQUEALING LOUDLY IN FLT. FL370 8.0 PSI DIFF FROM TOP CTR. REPLACED FIRST OFFICERS WINDSHIELD.SDR 2008UALA05648Slide · lowDOOR 2L SLIDE PRESSURE IN RED.
SDR 2008UALA03825Regulator · leakingOXYGEN LOST PSI INFLIGHT. FOUND LEAKING O2 REGULATOR. REPLACED O2 REGULATOR, SERVICED CREW O2 TO FULL AND LEAK CHECKED, ALL NORMAL.SDR 2008UALA03299Oxygen Mask · leakingO2 STILL SHOWS SLOW LEAK ABOUT 100 LBS PER 20 MIN. CAPT O2 MASK HAS PIN HOLE LEAK IN HOSE. REPLACED CAPT MASK ASSY, SERVICED CREW O2 TO FULL.SDR 2008UALA02510Smoke Detector · faultySMOKE LAV DETECT FAULT ECAM. SMOKE DETECTOR NOT WORKING (AFT LAV). REPLACED AFT LAV SMOKE DETECTOR, OPS CHECKED OK.
SDR 2008UALA02223Floorboard · damagedCARGO FLOORBOARD RPL S GLS PNL. ACCOMPLISHED MAJOR REPAIR AT LCQ AS A PART OF UAL EG PROJECT TO REPLACE FLOORBOARDS.SDR 2008UALA02135Frame · gougedAFT CABIN FRAME 69 GOUGED RT SIDE AT -Y1162. MAJOR REPAIR ACCOMPLISHED: INSTALLED ANGLE REPAIR.SDR 2008UALA02134Skin · gougedFUSELAGE SKIN GOUGED FWD OF FRAME 24 BETWEEN STR 43L AND 42L. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR 2007UALA04322Bottle · dischargedFLIGHT DIVERTED DUE TO SEVERAL PASSENGERS REQUESTING OXYGEN AND ONBOARD SUPPLIES EXHAUSTED. EARLIER IN FLIGHT AIRCRAFT EXPERIENCED A GRADUAL LOSS OF CABIN PRESSURE, DESCENDED TO FL240, PROBLEM RESOLVED. FLIGHT CONTINUED AT FL360. FOUND CPC MALFUNCTIONED. RESDR 2007UALA02866Unknown · odorSTRONG ELECTRICAL FUMES REPORTED IN AFT GALLEY. NO FURTHER INCIDENTS AS OF 8/22/07, UNABLE TO DUPLICATE SMELL,SDR 2007UALA00512Switch · faultyFOUND EMERGENCY EEL LIGHTS (NO SMOKING) FLASH ON AND OFF. [5-1-07] CYCLED NO SMOKING SWITCH EEL LIGHTS OPS NORMAL.SDR 2006UALA00337Structure · damagedDAMAGE TO THE HORIZONTAL STABILIZER AND TAIL CONE. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLERS INSTALLED WITH AIRBUS RAS APPROVALS.SDR 2005UALA01382Light · malfunctionedEMERGENCY EXIT LIGHT SYSTEM LIGHTS WERE FLICKERING, NOW ON FULL TIME OVERHEAD SIGNS AND PATH LIGHTS. RESET CIDS, OPS CHECKS NORMAL.