N8896A
Service difficulty reports · 96
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8896A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8896A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2016031100432Seat Track · corrodedCABIN, LT SIDE SEAT TRACK STICK HAS 5 AREAS OF CORROSION. 3RD SEAT TRACK STICK FROM FRONT. R & R LT SIDE SEAT TRACK WITH NEW SIDE TRACK IAW AMM 53-01-11.SDR REXA2016030900430Seat Track · corrodedNUMBER 1 FLOOR SEAT RAIL AT LBL 9 HAS CORROSION, AT MULTIPLE LOCATIONS FROM FWD END TO AFT END. R & R NR 1 LBL 9 SEAT TRACK IAW AMM 53-01-11.SDR REXA2016030600421Attach Angle · brokenVERTICAL STAB RT SIDE FAIRING, SMALL ATTACH ANGLE JUST AFT OF TRIM ACTUATOR BROKEN. R & R WITH FABRICATED ATTACH ANGLE ON VERTICAL STA6 RT SIDE SMALL FAIRING, JUST AFT OF TRIM ACTUATOR IAW SRM 51-24-21.SDR REXA2016030200420Fitting · crackedCLIP OTBD OF RBL 27 & FS 484 IS CRACKED. R & R CLIP AT RBL 27 & FS 484 IAW REO 601R-53-41-059.SDR REXA2016022500419Bulkhead · chafedCARGO BAY AFT PRESS BULKHEAD FWD FACE ABOVE FLOOR HAS SMALL CHAFED AREAS IN 8 PLACES. REMOVED 8 EACH CHAFE MARKS & FOUND 17 EACH CHAFE MARKS TO BE WITHIN LIMITS AFTER BLEND OUT IAW REO 601R-53-61-2155 REV A . PAD UP .051" MIN REMAINING, .051" MIN ALLOWED, 06SDR REXA2014103001087Light · crackedDMM 8835 SERVICE DOOR EMER LIGHT CRACKED. R & R SERVICE DOOR EMER LIGHT IAW 33-51-13. OPERATIONS CHECKED GOOD. THIS CLEARS DM 8835.SDR REXA2014082300843Lens · crackedEMERGENCY EXIT SIGN FLOOD LIGHT ON GALLEY BY THE SERVICE DOOR LENS & BASE CRACKED. NEF C-6, 120 DAYSSDR REXA2014060900580Connector · disconnectedSMOKE DETECTOR IN LAVATORY NOT WORKING. UPON REMOVAL OF LAVATORY SMOKE DETECTOR, FOUND CONNECTOR DISCONNECTED. RECONNECTED CONNECTOR & PERFORMED OPERATIONS CHECK IAW AMM 26-16-01. OPERATIONS CHECKED GOOD. OK FOR SERVICE.SDR REXA2014060900469Bulkhead · crackedFS 621 BULKHEAD CRACKED AT CARGO DOOR LINTEL FITTING. REPAIRED IAW REO 601R-53-61-1230.SDR REXA2014060900468Stringer · gougedFOUND STRINGER 23R GOUGED & CRACKED APPROXIMATELY 0.785” LONG AT APPROXIMATELY FS 200. REPAIRED IAW EA CRJ253-02620.SDR REXA2014060500462Hinge Fitting · out of toleranceLT ELEVATOR NR 1 HINGE FITTING HAS 0.050 INCHES GAP BETWEEN HINGE FITTING HALVES. REPAIRED IAW SRM 51-42-6, 51-42-13, 51-42-21 & 51-40-11.SDR REXA2014012900149Hydraulic System · contaminatedON TAKEOFF HYD 3 LOW PRESS FOLLOWED BY GEAR DISAGREE & NOSE DOOR WARNINGS. HYD 3 PRESS AT 1600 DURING FAILURE, CLEARED IN 2 MINUTES, ALL MSGS WERE GONE. ALL PRESS RETURNED TO NORMAL. COMPLIED WITH PA 05-018 REV K SCENARIO 1 BLED NR 3 HYD SYS & INBD BRAKES. SDR REXA2014012200133Hydraulic System · contaminatedON CLIMB OUT OF ESC, RECEIVED MASTER WARNING FOR GEAR DISAGREE, NOSE DOOR OPEN. ALSO MASTER CAUTION FOR HYD LOW PRESS SYS 3. HYD QTY SHOWING 100% WITH WHITE DIAGONAL LINES TEMP 19C, GEAR FINALLY CAME UP & MESSAGES WENT AWAY. BLED HYD SYS NR 3 IAW AMM 29-10-SDR REXA2013082701614Flashlight · inoperativeF/O FLASHLIGHT IS INOPERATIVE.SDR REXA2013071001347Feeder Cable · damagedEMERGENCY LIGHT INOPERATIVEE. R & R EMERGENCY LIGHT POWER STRIP IAW AMM 33-51-01. COMPLIED WITH OPS TESTS OF THE EMERGENCY LIGHTS IAW AMM 33-51-00-710-801. NO DEFECTS NOTED.SDR REXA2013062301206Light · inoperativeCABIN EMERGENCY LIGHT INOPERATIVE. R & R LIGHT IAW AMM 33-51-01. OPS CHECKED GOOD.SDR REXA2013022000358Hydraulic Line · looseON FLIGHT 4084 (DTW TO ITH) ON CLIMBOUT OF DTW, RETRACTED GEAR AND INITIALLY GOT HYD 3 LOW PRESS CAUTION SHORTLY FOLLOWED BY NOSE DOOR MASTER WARNING FOLLOWED BY GEAR DISAGREE MASTER WARNING. DURING THIS MAIN GEAR WERE SHOWING YELLOW AND NOSE GEAR SHOWING WHISDR REXA2013012100175Unknown · malfunctionedLEFT ENGINE SPOOL UP TIME LAGS BEHIND RIGHT ENGINE CAUSING UNNECESSARY YAW TENDENCIES IN FLIGHT. ALSO CAUSE LOSS OF DIRECTIONAL CONTROL ON "THURST REVERSER" DEPLOYMENT. W N1 MATCHED, THE N2 FOR RIGHT ENGINE IS LOWER BY 25%. THRUST LEVERS ARE NEARLY IMPOSSIBSDR REXA2012091601109Angle · crackedCRACK FOUND IN CAP ANGLES AT FS 559 RBL 19, LBL 9, AND LBL 18. REPAIRED IAW BOMBARDIER REO 601R-53-41-260 AND REO 601R-53-41-609.SDR REXA2012081401259Light · inoperativeLAST TWO OVERHEAD EMERGENCY FLOODLIGHT OUT. REMOVED AND REPLACED OVERHEAD EMERGENCY LIGHTS IAW AMM 33-51-18. OPS CHECKED GOOD.SDR REXA2012042100547Life Vest · unserviceableF/O LIFE VEST BAG TORN. REMOVED AND REPLACED F/O LIFE VEST IN ACCORDANCE WITH AMM 25-61-03.SDR REXA2012041000492Trim System · malfunctionedAILREON TRIM DOES NOT WORK AT ALL IN FLIGHT OR ON GROUND. RESET AILERON TRIM SYSTEM IAW AMM 27-12-00. OPS CHECKED GOOD.SDR REXA2012021400225Plug · missingRT ENG TAIL CONE HAS EVIDANCE OF BURN DAMAGE. FOUND BOROSCOPE PLUG S50 MISSING. REPLACED BOROSCOPE PLUG IAW AMM 72-00-00. REMOVED AND REPLACED RT EXHAUST FAIRING IAW AMM 78-11-01.SDR REXA201200114Engine · vibrationAIR RETURN AT 10,000 FEET AIRCRAFT STARTED SMALL VIBRATION, UNUSUAL SOUND FROM RIGHT SIDE OF AC, RIGHT ENGINE ITT WAS POINTING TO 12 O`CLOCK, RAN QRH, SHUTDOWN ENGINE, RETURNED TO DTW. REMOVED AND REPLACED RT ENGINE IAW AMM 71-00-00. REFERENCE DISC NR 1 AML SDR REXA201100962Warning System · activatedLT FUEL LOW PRESS CAUTION MSG IN FLIGHT ALL OTHER PRAMS NORMAL.SDR REXA201100906Switch · defectiveNR 2 ENGINE REV ICON AND NUMEROUS R REV UNLOCKED CAUTION FROM CRUISE THROUGH LANDING, NO CAUTION FROM 10000 FEET THRU TOP OF CLIMB. AT FL 330 R REV UNLOCKED STARTED INTERMITTENTLY THEN STAYED ON REST OF CRUISE CONTINUOUSLY. REMOVED AND REPLACED RT ENGINE T/RSDR REXA201100902Switch · defectiveTHRUST REV (R) UNLOCK MSG CONTINUED TO DISPLAY INTERMITTENTLY EVERY FEW SECONDS FOR THE LAST 10-15 MIN OF FLIGHT. INTERFERES WITH SAFE OPERATIONS. VERIFIED MEL PROCEDURE, T/R DEFERRAL CORRECTLY. A/C OK FOR SERVICE AT THIS TIME PER MEL 78-30-01.
REMOVED ANSDR REXA201100901Switch · out of adjustR REV UNLOCK MSG IN FLIGHT. ADJUSTED RT THRUST REV STOW SWITCH IAW CRJ 200 AMM 78-37-01. OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME.SDR REXA201100893Warning System · false activationRT REV UNLOCKED CAUTION MSG EVERY 1 MIN TO 5 SEC INFLIGHT. INTERFERES W/SAFE OPERATION. RT T/R CHECKS GOOD IAW AMM 78-30-00. DEFER CLEARED.SDR REXA201100515Skin · corrodedLT LOWER PLANK FUEL ACCESS HOLE AT WING STATION 12.245 HOLE NR 2 HAS FRETTING CORROSION WITH MINOR PITTING ON INBOARD AND OUTBOARD EDGE OF CUTOUT APPROX 0.002 DEEP AT WORST LOCATION IN A NON CRITICLAL REGION. REPAIRED IAW BOMBARDIER REO 601R57-21-030 H.SDR REXA201100514Skin · corrodedRT LOWER PLANK FUEL ACCESS HOLD AT WING STATION 54.897 HOLE NR 1 HAS FRETTING CORROSION WITH MINOR PITTING ON INBOARD AND OUTBOARD EDGE OF CUTOUT APPROX 0.002 DEEP AT WORST LOCATION IN A NON CRITICAL REGION. REPAIRED IAW BOMBARDIER REO 601R57-21-030 H.SDR REXA201100513Skin · corrodedLT LOWER PLANK FUEL ACCESS HOLE AT WING STATION 54.897 HOLE NR 1 HAS FRETTING CORROSION WITH MINOR PITTING ON INBOARD AND OUTBOARD EDGE OF CUTOUT APPROX. 0.002 DEEP AT WORST LOCATION IN A NON CRITICLAL REGION. REPAIRED IAW BOMBARDIER REO 601R57-21-030 H.SDR REXA201100512Skin · damagedLT LOWER PLANK FUEL ACCESS HOLE AT WING STATION 274.319 HOLE NR 14 HAS 3 EACH CHAFES ON INBOARD EDGE OF CUTOUT ON LIP MEASURING APPROX 0.145L X 0.025W X 0.002DEEP IN A NON CRITICAL REGION. REPAIRED IAW BOMBARDIER REO 601R-57-21-030 REV H.SDR REXA201100412Skin · damagedLT LOWER WING PLANK TRAILING EDGE HAS SEVERAL SMALL TOOLING MARKS COVERING A 1 SQUARE AREA AT APPROX WS 294.50. WORST SINGLE MARKS MEASURES APPROX .25 L X .005 W X .005D. REPAIRED IAW SRM 57-21-31, AND 51-12-00.SDR REXA201100411Bulkhead · damagedFS 621 BULKHEAD IS DAMAGED FROM SCREW CONTACT AT WL 102.5 LBL 17.5 AND 27. AREA APPEARS TO BE PREVIOUSLY REPAIRED. REPAIRED IAW BOMBARDIER REO 601R-53-61-2155.SDR REXA201100410ABulkhead · damagedFS 621 BULKHEAD IS DAMAGED FROM SCREW CONTACT AT WL 86, RBL 7.5. DAMAGE IS APPROX 0.125" LONG X 0.125" WIDE X 0.003" DEEP. REPAIRED IAW REO 601R-53-61-2155.SDR REXA201100399Bulkhead · scratchedFS 621 BULKHEAD IS SCRATCHED AS WL 140, RBL 16. DAMAGE IS APPROXIMATELY .5" LONG X 0.010" WIDE X 0.003" DEEP. REPAIRED IAW BOMBARDIER REO 601R-53-61-2155.SDR REXA201100397Bulkhead · scratchedFS 621 BULKHEAD IS SCRATCHED AT WL 140, RBL 16. DAMAGE IS APPROXIMATELY .5" LONG X 0.010" WIDE X 0.003" DEEP. REPAIRED IAW BOMBARDIER REO 601R-53-61-2155.SDR REXA201100396Bulkhead · damagedFS 621 BULKHEAD IS DAMAGED DUE TO SCREW CONTACT AT WL 102.5, RBL 17.5, 27, AND 36. REPAIRED IAW BOMBARDIER REO 601R-53-61-2155.SDR REXA201100394Angle · damagedFS 621 BULKHEAD STIFFENER ANGLE IS DAMAGED FROM SCREW CONTACT ALONG THE TOP EDGE OF ANGLE WL 119.5 AT LBL 9, 17.5, 27, AND RBL 9. REPAIRED IAW SRM 53-00-00, AND 52-12-00.SDR REXA201100395Structure · damagedFS 621 IS DAMAGED DUE TO SCREW CONTACT AT WL 102.5, RBL 9 AND RBL 7.5. DAMAGE IS APPROXIMATELY 0.003 INCH DEEP. REPAIRED IAW BOMBARDIER REO 601R-53-61-2155.SDR REXA201100517Structure · chafedCHAFE BETWEEN WING LOWER AFT SKIN PLANK AND MLG FAIRING AT RBL 45 MEASURING 0.030" DEEP IN ZONE "A". REPAIRED IAW BOMBARDIER REO 601R-57-21-880 REV B.SDR REXA201100466Structure · chafedCHAFE BETWEEN WING LOWER AFT SKIN PLANK AND MLG FAIRING AT RBL45 MEASURING 0.030" DEEP IN ZONE "A". REPAIRED IAW BOMBARDIER REO 601R-57-21-880 REV B.SDR REXA201100240Cowling · openTHE CORE COWLS OF THE NR 2 ENGINE CAME OPEN DURING FLIGHT AND THE TRANSLATING COWLS WERE SUBSEQUENTLY ALSO DAMAGED WHEN THE THRUST REVERSERS WERE DEPLOYED UPON LANDING. BOMBARDIER REO 601R-71-12-4046 WAS ISSUED TO INSPECT THE COWLS FOR FERRY FLIGHT FOR PERMANSDR REXA201100127Landing Gear · malfunctionedGEAR DISAGREE ON FINAL RT MAIN WAS RED DURING APPROACH 3 PREVIOUS FLTS IT TOOK LONGER FOR IT TO COME DOWN THAN OTHER GEAR RAN QRH CYCLED GEAR ALL CAME DOWN NORMAL. PERFORMED OK CHECK OF LANDING GEAR SYS BY PERFORMING GEAR SWING IAW AMM 32-30-00 AND C/W PA 05-SDR REXA201100017Idg · lack of lubeGEN 2 OFF CAUTION ON TAKEOFF ROLL. SERVICED RT IDG IAW CRJ AMM 12-13-24. RECONNECTED IDG AND OPS CHECKED NORMAL PER CRJ AMM 24-10-00. OK FOR SERVICE.