N901CF
Service difficulty reports not matched to an aircraft · 309
They name N901CF, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N901CF' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N901CF' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R7MR34258Actuator · inoperativeTRIM ACTUATOR ASSEMBLY, UNIT INOPERATIVE. OPERATES IN ONE DIRECTION ONLY. REPLACED WITH NEW, CORRECTED PROBLEM. (K)SDR R7MA34258Actuator · inoperativeTRIM ACTUATOR UNIT INOPERATIVE.SDR 2001F00698Beam · separatedBUMPER ASSEMBLY FLEXBEAM SEPARATION ALONG TRAILING EDGE OF 'Y'. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)SDR 2001F00694Nozzle · crackedRIGHT PRIMARY EXHAUST NOZZLE ASSEMBLY CRACKED BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)SDR 2001F00699Beam · separatedBUMPER ASSEMBLY FLEXBEAM SEPARATION AT TRAILING EDGE OF 'Y'. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)SDR R7MA33713Link · wornWORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNITS, CORRECTED PROBLEM.SDR R7MA33716Tube · leakingLEAKING BEYOND SERVICEABLE LIMITS. TUBE IS NO BENT BUT IS LEAKING FROM THE SWEDGE AND BRAZING AT (T) END. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR33368Light · inoperativeUNIT INOPERATIVE, CAUSING IIDS FAULT 2=10, SECONDARY ELEMENT FAILURE. LAMP IS SUBASSEMBLY TO IIDS ASSEMBLY, IIDS SN 008251-012 IS CURRENTLY INSTALLED AND HAS BEEN MORE RELIABLE THAN PREVIOUS INSTALLATIONS; THEREFORE REMSA IS ORDERING JUST THE LAMP ASSEMBLY ASDR 2001F00527Bumper Block · separatedSEPARATION OF TRAILING EDGE IN 'Y' AREA. REPLACED WITH NEW UNIT CORRECTED PROBLEM. CORE SHIPPED TO MDH FOR INSPECTION. (M)SDR R7MR33279Harness · shortedT6 WIRING HARNESS, INTERNAL SHORT. FAILED RESISSTENCE CHECK. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR32759Bumper Block · crackedLATERAL CRACK BEYOND SERVICEABLE LIMITS. REMOVED AND REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR33265Valve · leakingFRANGIBLE SELF SEALING VALVE, LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR33264Bearing · wornTHRUSTER BEARING RACE, WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR33263Bearing · wornELASTOMERIC LAMINATES WORN BEYOND SERVICEABLE LIMITS, WHICH IS CAUSING DIFFICULTY WITH BALANCING THE MAIN ROTOR HEAD ASSEMBLY. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR32619Gauge · looseSIGHT GAUGE RIBBON WILL NOT STAY ATTACHED AT BOTTOM OF INDICATOR TUBE, WHICH RENDERS THE QUANTITY OF HYDRAULIC FLUID IN THE RESERVOIR UNRELIABLE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR32618Actuator · leakingHYDRAULIC UNIT, DUAL SERVO ACTUATOR, MR CONTROL LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEMS.SDR R7MR32573Display · inoperativeUNIT INOPERATIVE. ROW OF LIGHTS ON ALPHA DISPLAY MISSING.SDR R7MR32373Display · inoperativeDISPLAY OF RT TORQUE/BARS AND NUMBERS/ INTERMITTENLY GOES BLACK. REPLACED WITH REPAIRED UNIT, CORRECTED PROBLEM.SDR 20001215SH031Bearing · delaminatedMAIN ROTOR CENTERING BEARIN ASSY , DELAMINATION. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001215SH029Friction Ring · roughCOLLECTIVE FRICTION UNIT ROUGH AND RATCHETY. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001215SH032Breather Tube · damagedHOSE, ENGINE OIL BREATHER, INSIDE OF HOSE IS BUBBLED. REPLACED WITH NEW UNIT, CORRECTED UNIT. (X)SDR 20001215SH033Display · malfunctionedINTEGRATED INSTRUMENT DISPLAY SYSTEM ASSEMBLY, MRB BALANCE DISPLAY ONLY SHOWS PARTIAL CHARACTERS. INCORRECT CALCULATIONS. (X)SDR 20001107SH017Bearing · debondedCENTERING BEARING ASSY, MAIN ROTOR, DEBONDING. (X)SDR 20001215SH030Bearing · delaminatedMAIN ROTOR ENTERING BEARING ASSY, DELAMINATION. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001107SH016Bearing · debondedCENTER BEARING ASSY, MAIN ROTOR, DEBONDING. (X)SDR 20001107SH025Friction Ring · wornCOLLECTIVE FRICTION UNIT LOST FRICTION CONTROL. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001107SH024Sleeve · wornSLEEVE, NOTAR FAN HUB, WORN BEYOND SERVICEABLE LIMITS. REPLACED 13 EACH WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001107SH023Bearing · wornBEARING RACE, THRUSTER, WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001107SH021Exhaust Pipe · crackedRIGHT PRIMARY EXHAUST NOZZLE CRACKED BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001107SH022Pitch Link · wornPITCH LINK ASSY, ROTOR CONTROL, WORN BEYOND SERVICEABLE LIMITS. REPLACED 5 EACH WITH NEW UNITS, CORRECTED PROBLEM. (X)SDR 20001030SH030Pitch Link · wornPITCH LINK ASSY, ROTOR CONTROL, WORN BEYOND SERVICEABLE LIMITS. EXCESSIVE WEAR INTO ROD END ASSY. (X)SDR 20001108SH002Bearing · debondedMAIN ROTOR CENTER BEARING ASSEMBLY IS DEBONDING. (X)SDR 20001107SH027Liner · wornROTOR BRAKE LINING WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEMS. (X)SDR 20001107SH020Battery · faultyBMS FAULTS 2 AND 4 TRIGGERED REGULARLY. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000919SH001Display · inoperativeUNIT INOPERATIVE. PARTS OF DIGITAL READOUTS AND FUEL QUANTITY BARS INTERMITTENTLY DISAPPEAR. (X)SDR 20000808SH025Link · wornHINGE AND SHIMS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000919SH002Bearing · wornDIVITS RESULTING FROM BEARING WEAR BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000808SH024Bearing · debondedMAIN ROTOR CENTER BEARING ASSEMBLY DEBONDING. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000808SH023Bearing · debondedMAIN ROTOR BEARING ASSY DEBONDING. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000518SH001Display · failedREJECTED NEW OUT-OF-BOX. SUSPECT Y2K SOFTWARE PROBLEM. INSTRUMENT PANEL 'BLACKED-OUT' UPON INITIALIZATION OF IIDS (AIRCRA STARTUP). REPLCAED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000601SH029Scissors · looseLINK ASSY, DRIVE, SCISSORS HAD EXCESSIVE PLAY IN JOINT AREA. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000601SH027Link Rod · wornPITCH LINK ASSEMBLY WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20001107SH026Bolt · wornBOLT - ROTOR BRAKE, WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000601SH028Blower · leakingBLOWER DRIVE ASSEMBLY LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000424SH018Beam · delaminatedDELAMINATION ALONG TRAILING EDGE IN Y-AREA. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000424SH017Beam · delaminatedDELAMINATION ALONG TRAILING EDGE IN Y-AREA. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000517SH026Igniter · damagedIGNITER HAD EXCESSIVE BURN IN SOME AREAS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000517SH029Control Box · failedREJECTED NEW OUT-OF-BOX. BOX WAS TRIMMED TO 111 C, BUT LATER FOUND OUT THAT PWC HAD ALREADY TRIMMED THE OVERHAULED ENGINE IN THE TEST CELL FOR ADDITIONAL 9 C THAT IS OPERATED WITH SB 28171. REPLACED W ITH NEW UNIT, CORRECTED PROBLEM. (X)SDR 20000517SH027Igniter · damagedIGNITER HAD EXCESSIVE BURN IN SOME AREAS. (X)SDR 2000ZZZX141Thermal Valve · fluctuatedOIL TEMP FLUCTUATION TO VALVE (NOT SEATING). REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
Back to N901CF