N902EV
Service difficulty reports · 182
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N902EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N902EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA201001677Lamp · burned outEMERGENCY LIGHT ON RT SIDE (1) FWD OF DOOR INOP. RELAMPED EMERGENCY LIGHT AS REQUIRED IAW AMM 32-42-01, OPS CHECK GOOD.SDR ASOA201001514Light · inoperativeRT EXTERIOR NR 3 EMERGENCY LIGHT INOP. R & R RT EXTERIOR NR3 EMERGENCY LIGHT IAW AMM 33-51-21. OPS CK GOOD. R & R RT EXTERIOR NR3 EMERGENCY LIGHT IAW AMM 33-51-21. OPS CK GOOD. (CLOSED)SDR ASOA201001357Battery Pack · inoperativeEXTERIOR EMERGENCY LIGHTS 7 AND 8 INOP. R & R NR4 EMERGENCY BATTERY PACK FOR LIGHTS IAW AMM 33-51-04. OPS CHECKS GOOD. NO DEFECTS NOTED. PLACARD REMOVED. DMIL CLEARED. (CLOSED)SDR ASOA201001317Battery Pack · inoperativeEXTERIOR EMERGENCY LIGHTS 7 AND 8 INOP. R & R NR4 EMERGENCY BATTERY PACK FOR LIGHTS IAW AMM 33-51-04. OPS CHECKS GOOD. NO DEFECTS NOTED. PLACARD REMOVED. DMIL CLEARED.SDR ASOA201001168Charger · inoperativeEXTERIOR EMERGENCY LIGHTS 7 & 8 INOPERATIVE. R & R BATTERY CHARGER NR 4 IAW AMM 33-51-05, OPS CHECK GOOD. DMIL CLEARED, PLACARD REMOVED. R & R BATTERY CHARGER NR4 IAW AMM 33-51-05, OPS CHECK GOOD. DMIL CLEARED, PLACARD REMOVED.SDR ASOA201000976Control Unit · failedFLT SPOILERONS CAUTION MESSAGE FLT SPOILERS CAUTION MESSAGE AND INBD GROUND SPOILER FAULT MESSAGE IN FLIGHT. (EMERGENCY DECLARED) CX FOUND SECU 2 MODULE B TO HAVE MULTIPLE FAULTS IN THE FAULT LOG. R & R RELAY K4CN IAW AMM 20-42-00. R & R NR 2 SECU IAW AMM 27SDR ASOA201000963Relay · failedDURING CRUISE, RECEIVED A SPOILERONS CAUTION MESSAGE ,FOLLOWED BY A FLT SPOILERS CAUTION MESSAGE FOLLOWED BY AN INBD GROUND SPOILER FAULT STATUS MESSAGE (EMERGENCY DECLARED) R & R RELAY K3CN FOR SECU POWER SUPPLY IAW ESPM 20-22-00 OPS CHECK GOOD JB-10 RETESTSDR ASOA201000773Clamp · looseFLT 4964...WHILE BOARDING PAX GOT MAIN BAT CHARGER, APU BAT CHARGER, CARGO BOTTLE AND APU BOTTLE LOW INDICATIONS. UPON INSPECTION FOUND SEVERAL BLEED LEAKS. RESECURED CLAMPS AND LINES AND NO FURTHER LEAKS NOTED. OPS CHECKED MAIN AND APU CHARGERS IAW 24-32-0SDR ASOA201000732Selector Valve · failedNOSE GEAR DISAGREE CYCLED 5 TIMES IAW QRH, HAD TO MANUAL EXTEND, NO NOSE WHEEL STEERING ON THE GROUND. (EMERGENCY DECLARED]) R & R NOSE GEAR SELECTOR VALVE IAW AMM 32-33-10, OPS CHECK IS GOOD, LEAK CHECK GOOD.SDR ASOA201000662Door · bindingMAIN CABIN DOOR DIFICULT TO OPEN. OPENED/ CLOSED MULITPLE TIMES " OPS TEST OF PAX DOOR" IAW AMM 52-11-00-710-801. NO TROUBLE FOUND, OK FOR SERV.SDR ASOA201000378Wire Harness · disconnectedSTALL FAIL MSG AFTER TAKEOFF. (ACFT RETURNED TO DEPARTURE AFTER T/O -- EMERGENCY DECLARED). FOUND WIRES FROM CAPTAINS STICK SHAKER MOTOR PULLED OUT OF CONNECTER. REINSTALLED WIRES IAW WM 27-35-00. NO OTHER SPS FAULTS FOUND IAW FIM 27-30-00 SPS SYS OPS CHECK SDR ASOA201000281Wire · looseSERVICE DOOR TRIM PANEL EXIT LIGHT INOP (FWD PF DOOR). FOUND WIRING FROM EMERGENCY POWER SUPPLY SWAPPED BETWEEN VERTICAL EMERGENCY LIGHT ASSY AND HORIZONTAL LIGHT ASSY. PROPERLY SWAPPED WIRING BACK TO CORRECT LIGHT IAW AMM 33-51-00 AND COMPLIED WITH OPS TEST SDR ASOA201000220Frame · corrodedGENERATED FROM OP 297/FRAME SECTION 333 BETWEEN RBL 26 AND LBL 26 CORRODED FWD AND AFT SIDE. FINISH INSTALLING FRAME PN 601R32004-55. TP161741 2/13/10 (AJ 2/13/10) INSTALLED REMAINING FASTNER IN FRAME 333 AND APPLIED FINISH A023 IAW SRM 51-42-21 AND 51-21-16SDR ASOA201000205Skin Splice · corrodedSKIN SPLICE DOUBLER AT FS 333 CORRODED IS SEVERAL PLACE FROM LBL24-RBL 24. REMOVED CORROSION FROM SKIN SPLICE DOUBLER AT FS 333 LBL 24-RBL 24 IAW SRM 51-12-00. REMOVE MATERIAL FOUND TO BE WITHIN LIMITS IAW SRM 51-21-31. BLENDED AREAS. COMPLETE STEP 5 B(5) PSDR ASOA201000204Frame · corrodedCORROSION FOUND ON FRAME FS 349 LBL 6 APPROX (MARKED). REMOVED FRAME. VERIFIED POSITION OF NEW FRAME AND DRILLED IAW SRM 51-40-11. INSTALLED FRAME IAW SRM 51-42-06.SDR ASOA201000203Frame · corrodedFRAME SECTION 333 BETWEEN RBL 26 AND LBL 26 CORRODED FWD AND AFT SIDE. REMOVED CORROSION ON FRAME IAW SRM 53-21-15. MECHANICALLY MEASURED FRAME 333 FOUND TO BE OUT OF LIMITS IAW SRM 53-21-15. REMOVED FRAME. DRILLED NEW FRAME IAW SRM 51-42-06 AND 51-42-21SDR ASOA201000202Intercostal · corrodedINTERCOSTAL AT LBL 2 BETWEEN FS 349-FS 364 IS CORRODED. REMOVED INTERCOSTAL. REMOVED GUSSETT REMOVED DOOR POSITION SWITCH SUPPORT BRACKET. REMOVED CABLE TIE STANDOFFS. DRILLED NEW INTERCOSTAL IAW SRM 51-40-11 READY TO INSTALL. INSTALLED INTERCOSTAL FASTESDR ASOA201000171Cargo Track · corrodedALL CARGO TRACKS IN CARGE COMPARTMENT ARE CORRODED. 4 EACH BULKHEAD FITTING ASSY'S NEED INSTALLED ON CARGO FLOOR TRACKS. INSTALLED BULKHEAD FITTINGS P/N CDSP 1900-509 PO NR M0000000255 IN NEW SERVICEABLE CONDITION ON TO CARGO COMPT. SEAT TRACKS IAW AMM 20-SDR ASOA201000154Plate · corrodedNUT PLATES CORRODED FOR CARGO DOOR STEP PLATE. REMOVED 14EA NUTPLATES FOR CARGO DOOR STEP PLATE IAW SRM 51-45-00 2. INSTALLED 10EA NEW NUTPLATES FOR CARGO DOOR STEP PLATE IAW SRM 51-45-00 3. INSTALLED 4EA. NUT PLATES REF SRM 51-45-00 & SRM 51-42-15 M45.SDR ASOA201000149Door · no testRIGHT EMERGENCY EXIT FAILED, FUNCTIONAL CHECK. UPON INSPECTION FOUND AIRFRAME INSULATION TO BE IN DOOR FRAME. REPOSITION INSULATION AS REQUIRED. DOOR FUNCTIONAL CHECK GOOD. IAW AMM 52-21-00 TASK 52-21-00-720-801.SDR ASOA201000148Door · no testLEFT EMERGENCY EXIT FAILED FUNCTIONAL CHECK. UPON INSPECTION FOUND AIRFRAME INSULATION TO BE IN DOOR FRAME. REPOSITIONED INSULATION AS REQUIRED. DOOR FUNCTIONAL CHECK GOOD IAW AMM 52-21-00 TASK 52-21-00-720-801.SDR ASOA201000113Seat Track · corrodedALL SEAT TRACKS IN CARGO COMPARTMENT ARE CORRODED. REMOVED CARGO COMPARTMENT SEAT TRACK & ANCHOR FITTINGS DUE TO CORROSION. INSTALLED SERVICEABLE CARGO FLOOR TRACK PER AMM 53-01-11-400-802, 20-21-00-910-801 AND SRM 53-61-49 PO NR 7620-00001.SDR ASOA201000097Frame · corrodedCORROSION FOUND ON FRAME FS 349 LBL 6 APROX. REMOVED CORROSION ON BACK SIDE OF FRAME IAW SRM 51-21-06.SDR ASOA200901137Intercostal · crackedWHILE WORKING SB 601R-53-067 FOR THE MODIFICATION OF THE OVERWING PRESSURE FLOOR - FOUND THE INTERCOSTAL AT FS 460 RBL 9-18 CRACKED AT LOWER FLANGE. REMOVED CRACK DEBURRED AND REMOVED SHARP EDGES IAW REO 601R-53-41-1089, REV -- NDT FS460 RBL9-18 FLANGE CUTOUTSDR ASOA200901012Floor Panel · crackedCRACK NOTED & MARKED ON PRESSURE FLOOR AT FS460.00 BETWEEN LBL9 & BL0.0, AFT OF INTERCOSTAL. DRILLED AND REMOVAL .250 HOLE TO REMOVE CRACK AT FS460.00 LBL 6 IAW REO 601R-53-41-082. PERFORMED ET AND PT INSP IAW REO 601R-53-41-1082 REV A DATE 09/20/09 IAW MM ANSDR ASOA200900921Flap · failedFLAPS FAIL AT 0 ON APPROACH KPHF. CREW NEVER TOUCHED FLAP LEVER. EMERGENCY DECLARED.SDR ASOA200900898Light · crackedLOWER EMERGENCY FLOOD LIGHT ON FWD WARDROBE CLOSET BASE IS CRACKED.SDR ASOA200900759Light · inoperativeAFT MOST CEILING EMERGENCY LIGHT IS INOP.SDR ASOA200900715Warning System · false activationIN FLIGHT CARGO BOTTLE LOW INDICATION, FOLLOWED QRH AND LANDED NEAREST SUITABLE AIRPORT. AFDL#438707-2...FLT 5502 DEL 111 MINS & FLT 5502 DEL 247 MINS. EN ROUTE TO BTR A/C DIVERTED TO MEI DUE TO MTC. FIRE CREW OPENED CARGO DOOR, IT WAS DETERMINED TO BE AN ISDR ASOA200900394Cover · missingREFER TO DMIL 472341-3 RT SIDE PHOTO ILLUMINESCENT COVER MISSING.SDR TRAX200800230Floorbeam · crackedLOWER FS 280 FLOORBEAM WEB CRACKED OUTBOARD OF RBL9 (MARKED). REPAIRED DAMAGE IAW EO 600-53-90.SDR TRAX200800192Fitting · crackedCLIP CRACKED AT FS 280, FLOOR LEVEL AT LBL 9 I/B (RESOLVED ON W/O: 82203 TASKCARD: N/R-00022). REPAIRED DAMAGED TO FS 280 WEB O/B OF LBL 9 IAW EO 600-53-90 C/W JB13225.SDR TRAX200800193Fitting · crackedCLIP CRACKED AT FS 280, FLOOR LEVEL AT RBL 9 I/B (RESOLVED ON W/O: 82203 TASKCARD: N/R-00023). REPAIRED DAMAGE TO FS 280 WEB O/B OF RBL 9 IAW EO 6+00-53-90 C/W.SDR TRAX200800189Fitting · crackedAAR - 1002 - FS 280 CLIP AT RBL 9 O/B IS CRACKED. REPAIRED DAMAGE TO FS 280 WEB O/B OF RBL 9 IAW EO 600-53-90 C/W. SUPPLEMENTAL SDR CLOSED 4/3/08.SDR TRAX200800190Fitting · crackedAAR - 1003 - FS 280 CLIP AT LBL 9 O/B IS CRACKED. CLIP IS REPLACED ON REPAIR OF FLOORBEAM ASA EC/TC REO 601R-53-21-787 MH13328. SUPPLEMENTAL SDR CLOSED 4/2/08.
SDR TRAX200800191Angle · crackedFS 280 AFT ANGLE CRACKED JUST O/B OF LBL 9.0. COMPLIED WITH EO 600-53-0091 PER REO 601R-53-11-136 & 601R53-11-1311.SDR TRAX200701776Bulkhead · crackedAFT PRESSURE BULKHEAD CRACKED AT LINTEL FITTING. REF; NDTM PART 6 53-61-153.SDR TRAX200701775Angle · crackedL-ANGLE PART NUMBER 601R35050-109 CRACKED.SDR TRAX200701741Placard · wornPASSENGER DOOR EXIT PLACARD IS WORN.SDR TRAX200701242Bracket · crackedASD AFT CABLE COUNTER BALANCE ANCHOR BRACKET CRACKED.SDR TRAX200701216Light · inoperativeCEILING EMERGENCY LIGHT AT SEAT 5AB INOP.SDR TRAX200700247Light · inoperativeCEILING EMERGENCY LIGHT 1EA INOP.SDR TRAX200601062Warning System · activatedFLAPS FAIL MESSAGE AT 39 DEGREES OF TRAVEL AT 10000 FEET. EMERGENCY DECLARED.SDR TRAX200600789Angle · crackedLT 625 OBLIQUE IS CRACKED. REMOVED LT 625 OBLIQUES AND INSTALLED A NEW 601-35012-51 PER CRJ SRM 53-61-17 AND 51-42-21, DR618 10-03-06.SDR TRAX200600788Angle · crackedRT 625 OBLIQUE IS CRACKED. REMOVED AND REPLACED CRACKED OBLIQUE ANGLE WITH SERVICEABLE PART P/N 601-35012-51 IAW CRJ 200 SRM 51-42-21. (SUPPLEMENTA-SDR CLOSED 10/3/06)SDR TRAX200600759Rib · crackedRT BATTERY RIB CRACKED. REMOVED RT BATTERY RIB ACCESS COVER. REMOVED CONNECTORS J410 & J412. REMOVED REQUIRED FASTENERS FOR REPAIR. CUT OUT DAMAGED SECTION OF RT BATTERY RIB IAW REO 601R-57-51-046. DC699 9-26-06. RA313. FABRICATED -6 DOUBLER FROM SERVICEABLE PSDR TRAX200600753Light · inoperativeEXTERNAL EMERGENCY LIGHT ON RT SIDE AFT OF EMERGENCY EXIT DOOR IS INOP.SDR TRAX200600585Smoke Detector · failedLAV SMOKE DETECTOR DID NOT GENERATE -AURAL MSG- SMOKE IN COCKPIT.SDR TRAX200600465Sign · inoperativeEMERGENCY FLOOR LEVEL EXIT SIGNS BU PAX AND SERVICE DOORS ARE INOPSDR TRAX200600424Light · inoperativeEMERGENCY EXIT FLOOD LIGHT AT PAX DOOR AND FWD FACING CURVED EMERGENCY EXIT MIDWAY DOWN AISLE ARE INOP.
Back to N902EV