N908NK
Service difficulty reports · 72
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N908NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N908NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2024093038408Bottle · low pressureL1 DOOR ASSIST BOTTLE PRESSURE LOW-SVCD L1 DOOR ASSIST BOTTLE W/ NITROGEN IAW AMM 52-10-00SDR GTIA2024091738379Bottle · low pressureL1 , L2 , R1 , AND R2 DOOR ASSIST BOTTLES REQ NITROGEN SVC-L1 , L2 , R1 , R2 DOOR ASSIST BOTTLES SVCD IAW AMM 52-10-00SDR GTIA2024090938361Bottle · low pressureL1 PASSENGER/ CREW DOOR ASSIST BOTTLE REQUIRES SVC-SVCD L1 DOOR ASSIST BOTTLE TO PROPER LIMITS IAW AMM 52-10-00SDR GTIA2024082938347A/C Pack · odorDIRTY SOCK/ FUMES AFTER TAKEOFF IN INIATIAL CLIMB. PACK 1 -ODOR ISOLATED TO PACK 1 AND CONFIRMED BY FLIGHT CREW. PACK 2 OPS NORMAL WITHOUT ODOR. TSM 05-50-00-810-831-A. AIRCRAFT OK FOR SERVICE. MOC # 70473.SDR GTIA2024071938242Megaphone · inoperativeAFT CABIN MEGAPHONE NOT TESTING GOOD-R/R AFT CABIN MEGAPHONE IAW A320 EMER EQUIP DRAWINGSDR GTIA2024071938241Megaphone · inoperativeAFT MEGA PHONE NOT WORKING-R&R AFT MEGA PHONE IAW CMM 25-65-51. OPS CHECK GOOD.SDR GTIA2024071538235Megaphone · inoperativeL1 MEGAPHONE INOPERATIVE R & R FWD MEGAPHONE AT L1 REF SAFETY EQUIP DWG, A320 EMER-EQUIP. OPS CHECKED GOOD, OK FOR SVC.SDR GTIA2024070238210Bottle · low pressurePASSENGER / CREW DOOR R2 ASSIST BOTTLE NEEDS SERVICING-SERVICED PASSENGER / CREW DOOR R2 IAW AMM 52-10-00SDR GTIA2024052138134Bottle · low pressureL2 & R2 DOOR ASSIST BOTTLE LOW-SERVICED L2 & R2 DOOR ASSIST BOTTLE IAW AMM 52-22-00SDR GTIA2024051838120A/C Pack · odorON CLIMB OUT WET SOCKS FUME EVENT. ISOLATED LEFT PACL 1 SMELL DISSIPATED-PERFORMED TROUBLESHOOTING PER TSM 05-50-00-810-831-A CONFIRMED PACK 1 AT FAULT.SDR GTIA2024040238042A/C Pack · odorSTRONG ODOR DURING DECENT PRIOR TO LANDING. REPORTED BY FA, MOSTLY AFT CABIN.-C/W TSM 05-50-00-810-831-A FOUND PACK 1 TO BE AT SOURCE. REF LP 3361174-2 FOR DEFERRAL. A/C OK FOR SVC. MOC # 110495/57545.SDR GTIA2024032238007A/C Pack · odorFUME EVENT DURING DESCENT FL390. RAN ELIMATION OF FUME PROCED. ODOR WENT AWAY WITH PACK 1 OFF-PERFORMED TSM 05-50-00-810-831-A FOUND PACK 1 TO BE AT FAULT. REF. LP 3359191-2 FOR DEFERRALSDR GTIA2024031938000A/C Pack · odorFUME EVENT CLIMBING THROUGH 7000'. DIRTY SOCK SMELL. RAN ELIMINATION OF FUMES PROCEDURE. ODOR WENT AWAY AFTER TURNING PACK 1 OFF. -C/W TSM 05-50-00-810-831-A FOUND PACK 1 TO BE SOURCE. DEACTIVATED PACK 1 IAW AMM 21-51-00-040-002-A. REF LP 3359183-2 FOR DEFERRASDR GTIA2024031237982Bottle · low pressureR2 & L2 DOOR ASSIST BOTTLES REQ SVC-SVCD R2 & L2 DOOR ASSIST BOTTLES PER AMM 52-10-00. NO DEFECTS NOTEDSDR GTIA2024030837966A/C Pack · odorSMELL OF DIRTY SOCKS/FEET IN CRUISE RAN ELIMINATION PROCEDURE PACK 1 OFF SMELL STOPPED.-CABIN ODOR ISOLATED TO PACK 1 REF TSM 05-50-00-810-831.SEE LOGPAGE 3359156-2 FOR CORRECTIVE ACTION.MOC 58966SDR GTIA2024030537965A/C Pack · odorSMELL OF DIRTY SOCKS/FEET IN CRUISE. RAN ELIMINATION PROCEDURE PACK 1 OFF SMELL STOPPED-CABIN ODOR ISOLATED TO PACK #1 REF TSM 05-50-00-810-831 SEE LOG PAGE 3359156-2 FOR CORRECTIVE ACTION MOC 58966SDR GTIA2024030237960A/C Pack · odorON CLIM UP HAD BURNING CRAYON SMELL THROUGHT AIR PLANE. FA CALLED & SMELL IT FRONT AND BACK. RAN ELIMINATION OF ODOR/ FAME CHECKLIST FOUND PACK 1 TO BE THE PROBLEM. SMELL WENT AWAY WITH PACK 1 OFF. FA IN BADE SAID IT COME BACK ON DESNT -PERFORMED INSPECTION PESDR GTIA2024022437936Megaphone · inoperativeAFT MEGAPHONE INOP-R&R AFT MEGAPHONE IAW EMERGENCY EQUIPMENT A320 DRAWINGSDR GTIA2024012637806A/C Pack · odorFUME EVENT IMMEDIATELY AFTER TAKEOFF. ELIMINATION OF FUMES PROCEDURE APPLIED. FUMES DISSIPATED AFTER TURNING OFF PACK 1.-PERFORMED TSM 05-50-00-810-831 FOUND PACK 1 AS SOURCE.SDR GTIA2024011937783A/C Pack · odorFUME EVENT ON DECENT. SHUT OFF PACK 1 AND SMELL WENT AWAY. ( PACKS - A320 WITH MOD. 30626/MP K6443 (ENHANCED ECS) OR A321 WITH MOD. 157080/MP K17996 (PACK FLOW SELECTOR) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) )--SDR GTIA2024011237769Unknown · unknownWHILE ON THE ARRIVAL TO FLL NOTICED THE ODOR OF STINKY SOX PACK 1 WAS TURNED OFF AND THE SMELL IMEDIATELY WENT AWAY-PERFORMED A PACK BURN OUT IN PACK #1 IAW TSM 05-50-00. NO ODOR SMELL NOTED. R/R RECIRCULAT FILTERS A/C OK FOR SERVICES REF AMM 21-21-41SDR GTIA2024011237765Unknown · unknown"F/A REPORTED DIRTY SOCK SMELL ON DESCENT. STARTED DESCENT AT 340-PERFORMED TSM 05-50-00-810-831-A AND PERFORMED VISUAL INSPECTION OF APU AND ENGINES AREAS NO LEAKS FOUND AND NO SIGNS OF SMOKE OR FUMES OR SMELL IN THE AIRCARFT. A/C OK FOR CONTINUED SERVICE, SDR GTIA2024010737734Unknown · unknownON DECENT FA NOTIFIED ME ABOUT 3000 FT OF A DIRTY SOCK SMELL IN THE CABIN-PERFORMED T/S IAW TSM 05-50-00-810 NO ODOR PRESENT. PREFORMED ECS DECONTAMINATION OF PACKS 1 &2 IAW AMM 21-00-00. RR BOTH RECIRC FILTERS IAW AMM 21-21-41 AS PRECAUTIONARY MEASURE A/C OK SDR GTIA2024010737733Unknown · unknownON DESCENT STRONG DIRTY SOCK ODOR ALL THE WAY TO THE GATE. THE SMELL WAS IN THE CABIN AND THE COCKPIT-PERF. TROUBLESHOOTING FOR CABIN ODOR IAW TSM 05-50-00-810-831-A. NO ODOR NOTED. CABIN ODOR SATISFACTORY. MOC 110810 NOTIFIEDSDR GTIA2023121537696Indicator · failedSTANDBY HORIZIN/ATTUDE INDICATOR FAILED IN FLIGHT-R & R'D ISIS INDICATOR OPS GOOD IAW AMM 34-22-25 AC OKAY FOR SERVICESDR GTIA2023121137681Unknown · unknownPASSENGER/CREW DOORS R2 AND L2 DOOR ASSIST BOTTLE NEEDS SERVICING -SERVICED PASSENGER/CREW DOORS R2 AND L2 IAW AMM 52-10-00-614-001-ASDR GTIA2023120537672Unknown · unknownFUME EVENT (COCKPIT ONLY) DURING DESCENT AT APPROX 8,000 - 12,000 FT. APPLIED PROCEDURE AND SMELL DISSAPATED AFTER PACK 1 OFF. DIRTY SOCK SMELL. APU OFF.-PERFORM ODOR ISOLATION IAW TSM 05-50-00-710-810-A, FOUND PACK 1 TO BE FAULTSDR GTIA2023120537671Flashlight · inoperativeFA - B FLASHLIGHT RED UNDER JUMPSEAT.-R/R F/A FLASHLIGHT IAW AMM 25-65-00/ A320 EMERGENCY EQUIP LAYOUT/ DRAWING A/C OK TO CONTINUE SERVICE.SDR GTIA2023111437612Unknown · unknownNOTICED DIRTY SOCK/PAINT SMELL ON DESCENT INTO IAH. TURNED PACK 1 OFF AND SMELL WENT AWAY. BEFORE TURNING OFF THE PACK THE SMELL PERSISTED FOR MORE THAN 2 MIN AND DIDNT SEEM LIKE IT WAS GOING TO GO AWAY.-PERFORMED TROUBLESHOOTING IAW TSM 05-50-00-810-831-A. FOSDR GTIA2023111037598Unknown · unknownDURING SERVICE CHECK FOUND BOTH AFT PAX/CREW DOOR, DOOR ASSIST BOTTLES REQ SERVICING -SERVICED THE DOOR ASSIST BOTTLES IAW AMM 52-10-00SDR GTIA2023110737584Unknown · unknownPACK #1 FUME EVENT DESENDING THROUGH 7,000 ON ARRIVAL IN TO MCO FUME IN COCKPIT TURNED OFF PACK #1 FUME DISAPEARED-PERFORMED APU OPS TEST IAW AMM 49-00-00, CK GOOD. PERFORMED #1 PACK OPS TEST & FOUND CONTAMINATED, FUME EVENT CONFIRMED.#2 PACK OPS CK GOOD OK FOSDR GTIA2023102437557Unknown · unknownFOUND L1 & R1 DOOR ASSIST BOTTLE BELOW LIMITS-SVCD L1 & R1 DOOR ASSIST BOTTLE TO PROPER LIMITS PER AMM 52-10-00SDR GTIA2023101737540Unknown · unknownL2 & R2 DOOR ASSIT BOTTLES NEEDS SERVICING -SERVICED PASSENGER/ CREW DOORS ASSIST BOTTLES L2 & R2 PER AMM 52-10-00SDR GTIA2023100237507Megaphone · inoperativeAFT MEGAPHONE INOP-R&R AFT MEGAPHONE. OPS CHECK GOOD. REF EMERGENCY EQUIPMENT DWG# A32O EMERG-EQUIP DRAWING. OK FOR SVCSDR GTIA2023092237490Epsu · inoperativeDURING SVC CHECK FOUND EPSU 12WL INOP-R/R EPSU 12WL IAW AMM 33-51-38. OPS CHECK GOOD.SDR GTIA2023042737136Flashlight · inoperativeFWD FA EMERGENCY FLASHLIGHT INOP-R&R FWD F/A EMERGENCY FLASHLIGHT IAW CMM 25-60-13/ A320 EMERGENCY EQUIP LAYOUTSDR GTIA2023042437128Unknown · unknownL1,R4,L4 DOOR ASSIST REQUIRES SERVICING-SERVICED L1, R4, L4 DOOR ASSIST IAW AMM 52-10-00SDR GTIA2022081536585None · noneL1 AND L2 DOOR ASSIST BOTTLES NEED SERVICING -SERVICED L1 & L2 DOOR ASSIST BOTTLES IAW AMM 52-10-00SDR GTIA2022062736494None · noneL1,L2,R1 AND R2 DOOR ASSIST REQUIRE NITROGEN SERVICE-SERVICED L1,L2,R1 AND R2 DOOR ASSIST BOTTLES PER AMM 52-10-00. LEAK CHECK GOODSDR GTIA2022052336431None · noneL1, R1 AND L2 DOOR ASSIST ACTUATORS REQUIRES SERVICE.-L1, R1 AND L2 DOOR ASSIST ACTUATORS SERVICED IAW AMM 52-10-00.SDR GTIA2022041436383None · noneL2 AND R2 DOOR ASSIST BOTTLES LOW PRES.-SERVICED L2 AND R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021111836127None · noneL1,R1,AND L2 DOOR ASSIST BOTTLES FOUND LOW DURING WEEKLY CHK-SVCD L1,R1, AND L2 DOOR ASSIST BOTTLES TO PROPER LVL IAW AMM 52-10-00.SDR GTIA2021101436046None · noneL2 & R2 DOOR ASSIST BOTTLES REQUIRE SERVICING-SERVICED L2& R2 DOOR ASSIST BOTTLES IAW AMM 52-10-00SDR GTIA2021071535869Bottle · low pressureR1 DOOR ASSIST BOTTLE PRE CHARGE LOW. -SERVICED R1 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2021050635718Bottle · low pressureL1 & R1 DOORS ASSIST BTL LOW-SERVICE L1 & R1 DOOR ASSIST BTL IAW AMM 52-10-00. NO LEAK NOTED AT THIS TIMESDR GTIA2021050635717Bottle · low pressureL2 & R DOOR ASSIST BTL LOW -SERVICE L2 & R2 DOOR ASSIST BTL IAW AMM 52-10-00. NO LEAK NOTED AT THS TIME.SDR GTIA2021040835677Knob · missingMEGAPHONE BY L1 DOOR MISSING VOLUME KNOB-R&R L1 DOOR MEGAPHONE IAW A320-EMER EQUP LAYOUT A/C OK FOR SVCSDR GTIA2021040535671Unknown · odorAFT FA REPORTED A "DUSTY" SMELL ON CLIMB OUT. -PERFORMED TSM 05-50-00-810-831-A. COULD NO DUPLICATE ORDOR NO UNDER CR DEFECTS NOTED. FLIGHT CREW PERFORMED ENGINE RUNS ACFT O.K. FOR SERVICE.SDR GTIA2021010435532Bottle · low pressureL1, L2 AND R2 DOOR ASSIST BOTTLE LOW. SERVICE L1, L2 AND R2 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.SDR GTIA2020121435501Bottle · low pressureL1 AND R1 DOOR ACCUMULATOR PRESSURE LOW (DOOR ASSIST). SERVICED L1 AND R1 DOOR ACCUMULTAOR (DOOR ASSIST), IAW AMM 52-10-00.
Back to N908NK