N908WN
Service difficulty reports · 292
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N908WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N908WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023110308071Floor Panel · pulledFWD FLOOR PANEL 221GF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] VERIFIED COMPLETION OF REPAIR OF UPPER SKIN ON PANEL 221GF IAW SRM 53-00-50-2R-1;[02] VERIFIED CORRECTIVE ACTION ITEM 1 COMPLETED.;[03] VERIFIED MEASUREMENT TABLE COMPLETED.SDR SWAA2023110308072Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SKIN PREVIOUS REPAIR HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222BF UPPER SKIN PREVIOUS REPAIR WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DSDR SWAA2023110308073Floor Panel · pulledFWD FLOOR PANEL 222CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222CF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB SDR SWAA2023110308066Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222DF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPAIRED PER SRM 53-00-50-2R-1. ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2023110308076Floor Panel · pulledAFT FLOOR PANEL 241XF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241XF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPAIRED PER SRM 53-00-50-2R-1. ATTACHED CURE SHEETS TO THIS FAULT RECORD.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2023110308080Floor Panel · pulledAFT FLOOR PANEL 241AAF UPPER SKIN HAS AREAS OF PULLED STRANDS<[01] AFT FLOOR PANEL 241AAF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL PER SRM 53-00-50-2R-0.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2023110308082Floor Panel · pulledAFT FLOOR PANEL 241ACF UPPER SKIN PREVIOUS REPAIR HAS AREAS OF PULLED STRANDS.<[01] REPAIRED AFT FLOOR PANEL 241ACF UPPER SKIN PULLED STRANDS IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2023110308083Floor Panel · pulledAFT FLOOR PANEL 241ADF UPPER SKIN PREVIOUS REPAIR HAS AREAS OF PULLED STRANDS.<[01] REMOVED FAILED PREVIOUS REPAIR THEN REPAIRED UPPER SURFACE OF AFT FLOOR PANEL 241ADF IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2023110308079Floor Panel · pulledAFT FLOOR PANEL 242VCF UPPER SKIN HAS AREAS OF PULLED STRANDS. AFT FLOOR PANEL 242VF<[01] AFT FLOOR PANEL 242VCF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPAIRED PER SRM 53-00-50-2R-1. ATTACHED CURE SHEETS TO THIS FAULT RECORD.;[02] VERIFIED MEASUREMENTS TSDR SWAA2023110308668Stringer · corrodedSTRINGER 25R; BS 539 HAS CORROSION AROUND FASTENERS COMMON TO SKIN<[01] STRINGER 25R; BS 539 CORROSION AROUND FASTENERS COMMON TO SKIN WAS 'REPAIRED PER EA 23-153-03025. THIS IS A CATEGORY A REPAIR AS DEFINED IN 737-700 SRM 51-00-06.';[02] VERIFIED STEPS COMPLSDR SWAA2023110308669Gusset · crackedGUSSET AT STRINGER 19L BS 500D IS CRACKED<[01] REMOVED AND REPLACED GUSSET AT STRINGER 19L BS 500D IAW SRM 51-10-02 SRM 51-40-02 DWG# 143A7902.;[02] VERIFIED MEASUREMENTS TABLE.SDR SWAA2023110308675Gusset · crackedGUSSET AT STRINGER 21L BS 500D IS CRACKED<[01] REMOVED AND REPLACED GUSSET AT STRINGER 21L BS 500D IAW SRM 51-10-02 SRM 51-40-02 DWG# 143A7902.;[02] VERIFIED MEASUREMENTS TABLE.;[03] CORRECTION FOR STEP 5; IS RII.SDR SWAA2023110308670Sill Drain · corrodedR/H AFT MOPSIL HAS CORROSION BS 955 RBL 55; BS 959 RBL 55; AND BS 967-987 RBL 50<[01] REMOVED AND REPLACED ASD MOP SILL I.A.W SRM 51-10-02-0G-0 PAR 9C; SRM 53-10-15-1A-1 ALLOWABLE DAMAGE 1; SRM 51-40-02-0G AND DWG 147A8501.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023110308664Floorbeam · corrodedCORROSION FLOOR BEAM UPPER CHORD BS 987 RBL 48 WL 208<[01] ACCOMPLISHED REPAIR ON FAULT#TTG8Q00NU8D9 PER SRM 53-70-51-2R-4 REPAIR 4 AND PER EA#23-153-03055-WIP1;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2023110608061Seal · crackedRT. HORIZONTAL STAB UPPER FORWARD SLIDE SEAL CRACKED.<[01] VERIFIED STEP 5 IN PARTIAL ITEM 1; OK TO INSTALL GIVEN.;[02] REMOVED AND REPLACED RT HORIZONTAL STAB FWD UPPER SLIDE SEAL IAW AMM 53-31-31-400-802.;[03] VERIFIED.<BR>VERIFIED MEASUREMENTS.SDR SWAA2023110307626Panel · crackedPANEL 195CL AFT CORNER RADIUS IS CRACKED.<[01] CRACKED AFT CORNER RADIUS ON PANEL 195CL WERE REPAIRED IAW SRM 51-70-05-2R-6.;[02] VERIFIED CRACKED AFT CORNER RADIUS ON PANEL 195CL WERE REPAIRED IAW SRM 51-70-05-2R-6.SDR SWAA2023110307622Floorbeam · corrodedCORROSION ON BS 986 FLOOR BEAM; LBL46; WL208<[01] ACCOMPLISHED REPAIR PER SRM 53-70-51-2R-6 REPAIR 6 ALTERNATIVE 4 FIGURE 205;[02] VERIFIED CORRECTIVE ACTION COMPLETE.<BR>VERIFIED MEASUREMENT TABLE.SDR SWAA2023110307623Floorbeam · corrodedCORROSION ON BS 986 FLOORBEAM; RBL 46; WL 208<[01] REPAIRED PASSENGER FLOORBEAM BS 986 IAW SRM 53-70-51-2R-4 REPAIR 4 AND PER EA#23-153-03055-WIP-1;[02] CORROSION ON BS 986 FLOORBEAM; RBL 46; WL 208 WAS REPAIRED IAW EA 23-153-03055;[03] VERIFIED STEPS COMPLETESDR SWAA2023110607174Panel · crackedLT WING L/E PANEL 521TB FWD O/B CORNER IS CRACKED (MARKED)<[01] LT WING L/E PANEL 521TB FWD O/B CORNER WITH CRACK WAS REPAIRED IAW SRM 51-70-05-2R-6.;[02] VERIFIED CORRECTIVE ACTION #1<BR>VERIFIED MEASUREMENTSSDR SWAA2023110607173Stiffener · crackedRH HORIZONTAL STABILIZER RIB 5 (STAB STA. 129.50); 3RD STIFFENER FROM FRONT SPAR; BOTTOM AREA WITH A CRACK.<[01] NDI REQUEST TO VERIFY CRACK AT DISCREPANCY AREA.;[02] HFEC INSPECTED SUSPECTED CRACK AREA IAW 737 NDTM PART 6; 51-00-00 PROCEDURE 23.<BR>CRACK NOTESDR SWAA2023041426502Light · inoperativeR/H AFT EXTERIOR EMERGENCY EXIT LT INOP.<[01] RELAMPED AFT R/H EE EXTERIOR LT IAW AMM 33-51-04.SDR SWAA2023041124824Cowling · pulled#1 ENGINE OUTBID SIDE COWL HAS MULTIPLE WORKING RIVETSON NO COWL PULLING THRU<[01] REMOVED AND REPLACED #1 ENGINE INLET COWL PER AMM 71-11-01SDR SWAA2023031515433Sign · missingEMERGENCY EXIT LIGHT LENS COVER AFT OF L2 DOOR MISSING BOTTOM ATTACHMENT SCREW (MARKED)<[01] REPLACED L2 DOOR EXIT SIGN ASSEMBLY IAW AMM 33-51-01. OPS CHECK GOOD.;[02] CW INSPECTION PER AMM 33-51-01SDR SWAA2023022810145Panel · damaged3 RIPS FOUND IN FWD CARGO BIN FLOOR.<[01] OK TO CONTINUE PER MEL#25-16-01; SP-1B.<BR>AUTH#122455;[02] R&R FWD CARGO FLOOR PANEL IAW AMM 25-52-10SDR SWAA2022080939674Light · inoperativeLEFT SIDE OVER WING EMERGENCY EXIT FLOOD LIGHT INOP<[01] OK TO CONTINUE PER MEL 33-2-03. SP 1B;[02] RELAMPED L/H OVERWING EMER.EXIT FLOOD LIGHT I.A.W AMM 33-51-01<BR>OPS CHCK GOOD.SDR SWAA2022060815787Epsu · inoperativeEMERGENCY AREA AISLE LIGHTS INOP AT ROWS 1 AND 4 L/H SIDE. / [01] REPLACED THE FWD GALLEY (M1675) EMERGENCY POWER SUPPLY AND BATTERY PACK PER AMM 33-51-06. OPS CHECK GOOD.SDR SWAA2021121449277Battery Pack · inoperativeSUPPLEMENTAL INFORMATION: EMERGENCY EXIT LIGHT BATTERY PACK (M1673 AFT GALLEY; CEILING; L/H) WILL NOT CHARGE ; EMERGENCY EXIT LIGHT BATTERY PACK (M1673 AFT GALLEY; CEILING; LH) WILL NOT CHARGE / [01] REPLACED EMERGENCY EXIT LIGHT BATTERY PACK M1673; OPS CHECK SDR SWAA2021121449276Battery Pack · inoperativeSUPPLEMENTAL INFORMATION: EMERGENCY EXIT LIGHT BATTERY PACK (M1672 AFT GALLEY; CEILING; R/H) WILL NOT CHARGE ; EMERGENCY EXIT LIGHT BATTERY PACK (M1672 AFT GALLEY; CEILING; RH) WILL NOT CHARGE / [01] REPLACED EMERGENCY EXIT LIGHT BATTERY PACK M1672; OPS CHECK SDR SWAA2021112947658Door Frame · out of adjustFWD ENTRY DOOR AFT FRAME TARGET HAS EVIDENCE OF RUBBING PER TASK CARD STEP 6 DOOR REQUIRES ADJUSTMENT PER TASK 52-11-00-820-801 / REMOVED AND REPLACED DAMAGED TARGET ANGLE ON FWD ENTRY DOOR AFT SIDE IAW SRM 51-40-02-0G-0 SECTION 6 AND BOEING DWG # 141A6124 ID:SDR SWAA2021121447469None · corrodedSUPPLEMENTAL INFORMATION: A113-09 AFT CARGO COMPARTMENT STA 727E TO 747; L/H Z ANGLE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS ORIG. 'T' .040 REMAINING .032 LOSS ;008 FOSDR SWAA2021121447480Angle · corrodedSUPPLEMENTAL INFORMATION: A113-16 AFT CARGO CO APARTMENT STA 727B TO 727C; L/H Z ANGLE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS : ORIG. 'T' .040 REMAINING .038 LOSS .00SDR SWAA2021121447479Angle · corrodedSUPPLEMENTAL INFORMATION: A113-15 AFT CARGO COMPARTMENT STA 727C TO 727D; R/H Z ANGLE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS: ORIG 'T' .040 REMAINING .029 LOSS.011 FOSDR SWAA2021121447478Angle · corrodedSUPPLEMENTAL INFORMATION: A113-14 AFT CARGO COMPARTMENT STA 727C TO 727D; L/H Z ANGLE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS : ORIG 'T'.040 REMAINING .027 LOSS .013 FSDR SWAA2021121447477Angle · corrodedSUPPLEMENTAL INFORMATION: A113-12 AFT CARGO COMPARTMENT STA 727D TO 727E; R/H Z ANGLE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS. ORIG 'T' 040 REMAINING .033 LOSS .007 FOSDR SWAA2021121447470Angle · corrodedSUPPLEMENTAL INFORMATION: A113-13 AFT CARGO COMPARTMENT STA 727D TO 727E; L/H Z ANGLE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0-ITEM 15; [02] EVALUATED ALLOWABLE LIMITS .ORIG 'T' .040 REMAINING .033 LOSS .007 FSDR SWAA2021121447468Angle · corrodedSUPPLEMENTAL INFORMATION: A113-08 AFT CARGO COMPARTMENT STA 747 TO 767; L/H Z ANGLE IS CORRODED. ; / [01] REMOVED CORROSION ON Z-ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS. ORIG 'T' .040 REMAINING .028 LOSS .012 FOUND OUT OF LIMITS IASDR SWAA2021121447464Angle · corrodedSUPPLEMENTAL INFORMATION: A113-04 AFT CARGO COMPARTMENT STA 787 +10'; L/H Z ANGLE FASTENER HOLE IS CORRODED. ; / [01] REMOVED CORROSION AFT CARGO Z-ANGLE STA 787 +10 L/H IAW SRM 51-10-02-0G-0 ITEM 15; [02] VERIFIED STEP 1 IS COMPLETE; [03] VERIFIED STEP 1; [04SDR SWAA2021121447463Angle · corrodedSUPPLEMENTAL INFORMATION: A113-03 AFT CARGO COMPARTMENT STA 867+3'; LBL 9; FLOORBOARD SUPPORT ANGLE HORIZONTAL FLANGE BOLT HOLE IS CORRODED. ; / [01] REMOVED CORROSION FLOOR BOARD SUPPORT ANGLE IAW SRM 51-10-02-0G-0 ITEM 15;13] OK TO INSTALL REPAIR PARTS; [14]SDR SWAA2021121447365Angle · corrodedSUPPLEMENTAL INFORMATION: A113-01 AFT CARGO COMPARTMENT STA 947 FLOORBOARD SUPPORT ANGLE RBL 20 TO LBL 10; HORIZONTAL FLANGE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION ON SAT 947 FLOORBOARD SUPPORT ANGLE AND CHECK WITH 10X MAGNIFYING GLASS IAW SDR SWAA2021121447475Angle · corrodedAFT CARGO, BS 727E - 747, RT ZEE ANGLE HAS SEVERAL AREAS OF CORROSION. REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15. FOUND OUT LIMITS IAW SRM 53-00-53-1A-2, FIG 103. REMOVED THE ZEE ANGLE FROM BS 727-747 IAW SRM 51-40-02-O-OG. FABRICATESDR SWAA2021121447466Angle · corrodedA113-06 AFT CARGO COMPARTMENT STA 767 TO 787; L/H Z ANGLE HAS SEVERAL AREAS OF CORROSION. ; / [01] REMOVED CORROSION Z-ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS .ORIG 'T' .040 REMAINING .027 LOSS .013 FOUND OUT LIMITS IAW SRM 53-00-5SDR SWAA2021121447461Shield · corrodedAFT CARGO BS 767 - 787, CARGO DOOR SURROUND FWD SHIELD HAD SEVERAL AREAS OF CORROSION. REMOVED CORROSION ON FWD SHIELD IAW SRM 51-10-02-0G-0 ITEM 15. FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103. REMOVED DAMAGED SHIELD IAW SRM 51-40-02-OG-0. LOCATED SDR SWAA2021121446998Door · looseR1 SERVICE DOOR IS SAGGING. ; / [01] REMOVED FWD GALLEY SERVICE DOOR GUIDE ARM IAW AMM 52-41-21-000-801.; [02] REMOVED LOWER GUIDE PLATE IAW SRM 51-40-02-0G-0.; [03] REMOVED FWD GALLEY SERVICE DOOR FUSELAGE TORQUE TUBE ACCESS PANEL IAW SRM 51-40-02-0G-0.; [04]SDR SWAA2021083010880Seal · crackedRIGHT HORIZONTAL STABILIZER UPPER SLIDER CRACKED. ; / [01] REMOVED AND REPLACED SLIDER SEAL IAW 20-50-11 AND SRM 51-40-02; [02] REMOVED AND REPLACED SLIDER SEAL IAW AMM 53-31-31SDR SWAA2021083010882Seal · crackedLEFT HORIZONTAL STABILIZER UPPER SLIDER CRACKED. ; / [01] REMOVED AND REPLACED SLIDER SEAL IAW AMM 20-50-11 AND SRM 51-40-02; [02] REMOVED AND REPLACED SLIDING SEAL IAW AMM 53-31-31SDR SWAA2021052775830Girt Bar · out of positionAFT ENTRY DOOR SLIDE CATCHING ON THRESHOLD WHEN CLOSING ; / PERFORMED GVI OF AFT ENTRY DOOR SLIDE-NO DEFECTS. REPOSITIONED GIRT IAW/REF AMM 25-66-11. OK FOR SERVICE.SDR SWAA2021051068993Sign · looseEMERGENCY EXIT LIGHT NEEDS SECURING ; SIGN LOOSE AT THE EMERGENCY EXIT ROWS / RESECURED LIGHT ASSYRIAN. OPS CK OKAY REF AM 33-51-01SDR SWAA2021050644574Seal · damagedL/H HORIZONTAL STAB UPPER FWD SLIDING SEAL DAMAGED / R&R L/H HORIZONTAL STAB UPPER FWD SLIDING SEAL REF AMM 53-31-31.SDR SWAA2020012040540Slide · out of positionR1 DOOR ESCAPE SLIDE SKIRT DISPLACED. REPOSITIONED SLIDE PER MT.SDR SWAA2019121639673Regulator · failedDECLARED EMERGENCY-----------------------------------------DEPARTING FL390 CABIN ALTIMETER HORN AND LIGHT CAME ON FOLLOWED QRH & QRC CABIN ALTITUDE WAS CONTROLLABLE NO DISCOMFIT NOTED BY CREW AND PASSENGER. / R&R #2 ENGINE HIGH STAGE PRESSURE REGULATOR PER AMM
Back to N908WN