N921XJ
Service difficulty reports · 153
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N921XJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N921XJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2016071301291Battery Pack · inoperativeFOUND EMERGENCY EXIT OVERWING LIGHTS RT AND LT FWD INOPERATIVE. REMOVED AND REPLACED THE NR 3 BATTERY PACK IAW AMM 33-51-17 OPS CHECKED GOOD.SDR REXA2016030800375Glowstrip · looseGLOW STRIP ON GALLEY FLOOR HAS COME LOOSE. ADHERED GLOW STRIP IAW THE AMM 33-51-01.SDR REXA2015122801216Floorbeam · crackedFLIGHT DECK FLOORBEAM FWD OF FS 280 AT LBL 12 HAS A SUSPECTED CRACK. REPAIRED FLIGHT DECK FLOORBEAM FWD OF FS 280 AT LBL 12 IAW EO 53254. THIS IS A MAJOR REPAIR.SDR REXA2015122801213Retainer · gougedCENTER CARGO DOOR LOWER SEAL RETAINER HAS SEVERAL GOUGES IN BOTH CORNERS. REPLACED LOWER SEAL RETAINER WITH NEW SERVICEABLE RETAINER PN LE670-39644-1 IAW AMM 52-35-07-400-802-A01. LEAK TESTED GOOD IAW AMM 52-00-00-790-801-A01.SDR REXA2015122801212Retainer · gougedFORWARD CARGO DOOR LOWER SEAL RETAINER HAS SEVERAL GOUGES ON BOTH CORNERS. REPLACED LOWER SEAL RETAINER WITH NEW SERVICEABLE RETAINER PN LE670-39644-1 IAW AMM 52-35-02-400-802-A01, LEAK CHECKED GOOD IAW AMM 52-00-00-790-801-A01.SDR REXA2015122801211Bracket · crackedRIGHT AIR CONDITIONING RAM AIR WATER SPRAYER LINE BRACKET IS CRACKED AT STRINGER 7R. R & R RT AIR CONDITIONING RAM AIR WATER SPRAYER LINE BRACKET PT MM 670-97107-001 IAW SRM 51-42-21-001-001-A01.SDR REXA2015122701225Plate · corrodedPASSENGER DOOR KICK PLATE ANGLE & MID CAP ANGLE CORRODED. REPLACED CORRODED PAX DOOR KICK PLATE ANGLE & MID CAP ANGLE WITH NEW SERVICEABLE PARTS IAW SRM 51-42-06-001-001-A01. SEE CONTINUATION CARD 81517211 108 FOR STEPS 6 - 10.SDR REXA2015122701218Floorbeam · crackedFLIGHT DECK FLOORBEAM FWD OF FS 280 AT RBL 12 HAS A SUSPECTED CRACK. REPAIRED FLIGHT DECK FLOORBEAM FWD OF FS 280 AT RBL 12 IAW EO R53254. THIS IS A MAJOR REPAIR.SDR REXA2015122720217Bulkhead · corrodedINTERGRANULAR CORROSION UNDER CORROSION CAP ON FS 280 LOWER WEB AT LBL 9. REPAIRED LT FS 280.00 LOWER BULKHEAD WEB IAW GREO 670-53-11-594 REV A DATED 2015 06 26. THIS IS A MAJOR REPAIR.SDR REXA2015122301222Angle · corrodedSERVICE DOOR ENTRANCE LOWER SILL ANGLE IS CORRODED. CONTINUATION CARD 107 & 117. REPAIRED SERVICE DOOR ENTRANCE LOWER SILL ANGLE CORROSION BY REPLACING ANGLE PN'S SH670-31982-1, SH670-31996-3, SH670-31982-1, SH670-31986-1 & BRACKET PN'S SH670-32040-3, SH670-SDR REXA2015122301220Beam · corrodedFOUND CORROSION ON UPPER FLANGE OF FS 280 TRANS BEAM AT FWD EDGE INBD OF RBL 9. R & R FS 280.00 RT TRANSVERSE BEAM, PN CC670-34094-1S, IAW SRM 51-42-11-001-001-A01, 51-42-21-001-001-A01, 51-42-06-001-001-A01 & EO R53117.SDR REXA2015122301219Beam · corrodedFOUND CORROSION ON UPPER FLANGE AT FS 280 TRANS BEAM U UNDER THE CORROSION CAP OTBD OF LBL 9. R & R FS 280.00 LT TRANSVERSE BEAM PN CC670-34094-1S IAW SRM 51-42-06-001-001-A01, 51-40-11-001-001-A01, 51-42-21-001- 001-A01 & EO R53117.SDR REXA2015122301214Angle · corrodedFORWARD J ANGLE AT FS 280, BETWEEN LBL & RBL 9 IS CORRODED. REMOVED & REINSTALLED LT & RT FS 280.00 BACKUP FITTINGS IAW SRM 51-42-21-001-001-A01 & 51-42-22-001-001-A01. R & R FS 280.00 FWD J ANGLE, PN CC670-34095-1, IAW SRM 51-40-11-001-001-A01, 51-40-06-001SDR REXA2015122201223Seal Depressor · corrodedCORROSION ON SERVICE DOOR LOWER SILL DEPRESSOR AROUND ALL FASTENER HOLES. R & R SERVICE DOOR LOWER DEPRESSOR SEAL PN SH670-31412-7 IAW SRM 51-42-06-001-001-A01.SDR REXA2015122001221Channel · crackedAFT FUSELAGE FAIRING CHANNEL IS CRACKED. R & R AFT FUSELAGE FAIRING CHANNEL PT CC690-39251-1 IAW SRM 51-40-11-001-001-A01 & 51-42-13-001-001-A01.SDR REXA2015122001210Strap · crackedAFT FUSELAGE FAIRING JOINT STRAP CRACKED AT FS 882. REPAIRED AFT FUSELAGE FAIRING JOINT STRAP AT FS 882 IAW RE9O 690-53-82-052 REV DATED 2014 04 09.SDR REXA2015121701224Floor Support · crackedCOCKPIT FLOORBOARD 221ALF LT SUPPORT ANGLE IS CRACKED. R & R COCKPIT FLOOR SUPPORT ANGLE, PN CC670-33199-3 IAW SRM TASK 51-42-06-001-001-A01.SDR REXA2015121401215Drag Angle · crackedPASSENGER DOOR AFT DRAG ANGEL IS CRACKED. COMPLY WITH REO 670-52-11-072 REV F 2015 04 26 TYPE II REPAIR.SDR REXA2015103100995Cover · damagedMULTIPLE E LIGHT FLOOR TRACK COVERS DAMAGED & FILM MISSING. R & R COVERS & INSTALLED NEW FILM IAW AMM 33-51-01.SDR REXA2015102100978Oxygen Mask · damagedFIRST OFFICER 02 MASK HARNESS & HEAD BAND MAY HAVE A PIN HOLE. BAND DOES NOT APPEAR TO FULLY INFLATE. R & R FIRST OFFICERS 02 MASK IAW AMM 35-11-12. OPERATIONS CHECKED GOOD.SDR REXA2015091000856Glowstrip · detachedEMERGENCY GLOW STRIP ON FLOOR ROW 12 AC LT DETACHED. SECURED EMER GLOW STRIP ON FLOOR AT ROW 12 AS REQUIRED LT SIDE.SDR REXA2015082100814Oxygen Mask · inoperativeOBSERVER O2 MASK INOPERATIVE. PLACED OBSERVER O2 MASK ON DEFERRAL IAW MEL 35-10-1 CAT A, PLACARD INSTALLED. COMPLIED WITH PROCEDURES, MXC NOTIFIED 95909 & ENTERED IN MM02. R & R 02 MASK IAW AMM 35-11-12. OPERATIONS CHECKED GOOD. PLACARD REMOVED & O2 MASK SDR REXA2015070500658Seal · brokenSEAL ON AFT PBE BROKEN. INSTALLED SEAL IAW AMM 35-30-00.SDR REXA2015052800528Lens · crackedSERVICE DOOR EXIT SIGN LENS CRACKED. R & R SERVICE DOOR EXIT SIGN LENS IAW AMM 33-51-05. OPERATIONS CHECKED GOOD.SDR REXA2015022100238Battery · dischargedEMERGENCY FLASHLIGHT BATTERY DEAD. R & R FLASHLIGHT BATTERY IAW AMM 25-61-02. ALL CHECKED GOOD. PN 94-01-0021.SDR REXA2014032300311Battery Pack · dischargedSEVERAL EMERGENCY LIGHTS INOPERATIVE IN FWD CABIN, FWD SIDE OF CLASS DIVIDER & FWD LT EXTERNAL LIGHT. REMOVED NR 1 EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-17-000-801-A02 & INSTALLED SERVICEABLE BATTERY PACK IAW AMM 33-51-17-400-801-A02. OPERATIONAL TEST GSDR REXA2014032000305Light · crackedCABIN EMERGENCY LIGHT STRIPS SIX EACH, CRACKED & BROKEN. REPLACED LIGHT STRIPS IAW AMM 33-51-01-400-801-A21. STRIPS WERE PREVIOUSLY REMOVED FOR INSPECTION.SDR REXA2014031900316Panel · gougedC1 PANEL 584EB GOUGED OUT OF LIMITS. LOCATED & DRILLED NEW PANEL IAW SRM 51-40-11-001-001-A01.SDR REXA2014031900315Seat Track · corrodedCORROSION ON SEAT RAIL FWD OF FWD LAVATORY. R & R RT FWD SEAT RAIL IAW AMM 53-00-49-000-801-A01 & 53-00-49-400-801-A07, TORQUE WRENCH USED CUT 306-3.SDR REXA2014031600314Panel · gougedPANEL 584GB GOUGED OUT OF LIMITS. REMOVED UNSERVICEABLE PANEL 584GB IAW AMM 57-51-32-000-801-A01 & RECEIVED SERVICEABLE PANEL 584GB.SDR REXA2014031600313Panel · gougedPANEL 684EB GOUGED OUT OF LIMITS. REMOVED UNSERVICEABLE PANEL 684EB IAW AMM 57-51-32-000-801-A01 & RECEIVED SERVICEABLE PANEL 684EB.SDR REXA2014031600312Doubler · crackedLOWER TCAS ANTENNA DOUBLER HAS CORROSION. R & R ANTENNA DOUBLER IAW SRM 51-42-06-001-001-A01 & 51-42-20-001-001-A01. PRIMED & PAINTED IAW SRM 51-25-06-001-001-A01 & 51-25-16-001-001-A01.SDR REXA2013112602188Life Vest · missingTHREE OF EIGHT INFANT LIFE VESTS ARE MISSING FROM LOWER AFT WARDROBE COMPARTMENT. INSTALLED THREE NEW INFANT LIFE VESTS TO WARDROBE LOWER AFT COMPARTMENT IAW CRJ900 AMM 25-61-03. ALL CHECKED GOOD PN ON P0640-101.SDR REXA2012120601575Floorbeam · crackedFLIGHT DECK FLOORBEAM AT LBL 12.0 CRACKED AT BACK-UP FITTING ATTACH POINT. REPAIRED LBL 12 BEAM IAW EO R53254. AAR SM-74.SDR REXA2012120601574Floorbeam · crackedFLIGHT DECK FLOORBEAM AT LBL 12.0 CRACKED AT BACK-UP FITTING ATTACH POINT. REPAIRED LBL 12 BEAM IAW EO R53254. PN CC670-331-3. AAR SM-74.SDR REXA2012092800977Shutoff Valve · malfunctionedAT F360 L BLEED DUCT WARNING AND LT BLEEDS CLOSED. THE RT SIDE PRSOV VALVE CLOSED ON ITS OWN. PERFORMED EMERGENCY DESCENT TO 10K FT CABIN ALTITUDE CLIMBED TO 12,500 FT BEFORE STABILIZING PRIOR TO 10K FT. PAX O2 MASKS WERE MANUALLY DEPLOYED. LT DUCT WARNINGSDR MALA110294Charger · inoperativeSERVICE CHECK, FWD F/A GALLEY EMERGENCY LIGHTS ARE INOP. R & R NR 1 E AND E BAY EMERGENCY LIGHT BATTERY CHARGER REF MM 33-51-17 AND PERFORMED SATISFACTORY OPS CHECK IAW MM33-51-00, PN 2013-1A, SN OFF 98041, SN ON 103109, PN 11-0049, SN OFF 22971, SN ON 23004.SDR MALA110293Floorbeam · corrodedLEFT BS 280 FLOORBEAM CORRODED BL0-LBL9. R & R LT 280 BEAM IAW SRM 51-42-06, 51-42-21, & EO RS3117.SDR MALA110292Floorbeam · corrodedRIGHT 280 FLOORBEAM CORRODED BL0-RBL9. R & R RT 280 FLOORBEAM IAW SRM 51-42-06, 51-42-21, & EO R53117.SDR MALA201112160291Floor Support · corrodedFLIGHTDECK FLOOR SUPPORT ANGLE CORRODED FS 28. R & R FLIGHTDECK FLOOR SUPPORT ANGLE IAW SRM 51-42-06, 51-42-21.SDR MALA110284Floor Support · corrodedFOUND FLOOR SUPPORT CORRODED AROUND FASTENER HOLES. R & R FLOOR SUPPORT IAW SRM.SDR MALA110283Threshold · corrodedFOUND CORROSION ON THE PAX DOOR THRESHOLD. R & R THRESHOLD IAW SRM.SDR MALA110272Bolt · looseRT OVERWING SAFETY LINE FUSELAGE ATTACH POINT HARDWARE CORRODING. R & R RT OVERWING SAFETY LINE FUSELAGE ATTACHED POINT HARDWARE IAW AMM 25-63-04.SDR MALA110271Bolt · looseLT OVERWING SAFETY LINE FUSELAGE ATTACH POINT HAS CORRODED HARDWARE AND 2 LOWER BOX ATTACH BOLTS ARE LOOSE. R & R HARDWARE & TORQUED 2 LOWER BOLTS ON LOWER BOX & LT OVERWING SAFETY LINE FUSELAGE ATTACH POINT IAW AMM 25-63-04.SDR MALA110253Light · missingFOUND EMERGENCY FLOOR PATH LIGHT MISSING IN GALLEY AREA. INSTALLED EMERGENCY LIGHT.SDR MALA110140Light · looseFLOOR TRACK LIGHTING CAPTAIN SIDE IN GALLEY LOOSE. R & R FLOOR TRACK LIGHTING CAPTAIN SIDE IN GALLEY AREA IAW AMM 33-51-01. OPS CHECK GOOD.SDR MALA110039Light · inoperativeLEFT AND RIGHT EMERGENCY FLOOR PATH LIGHTING IN GALLEY DEGRADED. REMOVED AND REPLACED GALLEY LEFT AND RIGHT EMERGENCY FLOOR PATH LIGHTING, P/N ON/OFF PL88-900LH00, PL88-930LH05 AND PL88-910LH00, IAW AMM CH 33-51-01. OPS CHECKED GOOD.SDR MALA110010Light · looseSTRIP ON FLOOR IN FRONT OF WASTE CART HAS PULLED LOOSE. INSTALLED SERVICEABLE EMERGENCY FLOOR TRACK LIGHT FWD OF WASTE CART AMM CHP. 33-51-01 SECURITY CHECK GOOD PN PL88-900LH00.SDR MALA100158Light · crackedEMERGENCY FLOOR LIGHTING IS CRACKED IN FRONT OF LAV AND ON LEFT SIDE OF GALLEY. REMOVED AND REPLACED EMERGENCY FLOOR LIGHTING IN FRONT OF LAV AND LEFT SIDE OF GALLEY IAW CRJ900M AMM 33-51-02. NO FURTHER ACTION REQUIRED AT THIS TIME.SDR MALA100068Light · missingF/A REPORTS FLOOR PATH LIGHTING MISSING IN FRONT OF CLOSET. INSTALLED FLOOR PATH LIGHTING.
Back to N921XJ