N924XJ
Service difficulty reports · 210
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N924XJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N924XJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2021040100190Light · missingEMERGENCY EXIT ROW 12 A/B FLOOR PROX LIGHT MISSING. INSTALLED NEW FLOOR PROX LIGHT AT EMERGENCY EXIT ROW 12 A/B IAW CRJ-900 AMM 33-51-01 P/N PL1600LH07SDR REXA2021022500075Fitting · damagedWHILE INCORPORATING SB 670BA-57-020, FOUND REAR SPAR MOD PREVIOUSLY C/W FITTINGS AT WS 48.95 INTERFERE WITH FASTENER INSTALLS ON LT AND RT SIDES. REPAIRED RT SIDE BATHTUB REAMER DAMAGE AND INTERFERENCE WITH FASTENER ISSUE ON LT AND RT FITTINGS IAW MHIRJ REO 6SDR REXA2020110900738Relay · inoperativeBOTH LT OVERWING EMERGENCY EXIT LIGHTS INOPERABLE. R & R K135 IN JB-11 PCB5, IAW AMM 24-06-11 & 20-42-00. R & R K198 RELAY, IAW AMM 33-51-19. RESECURED P377, IAW ESPM 20-26-00. P/N ON/OFF M83536117-002L P/N ON/OFF YAD4F.SDR REXA2019120281716Lamp · inoperativeLOWER MAIN CABIN DOOR EXIT SIGN HAS BURNED OUT LIGHT BULBS. RELAMP LOWER MAIN CABIN DOOR EXIT SIGN IAW CRJ 900 AMM 33-51-00. OPS CHECK GOOD.SDR REXA2019091201340Light · inoperative3 LIGHT BULBS ARE OUT FOR THE AIRSTAIR DOOR EMERGENCY LIGHT. RELAMPED FLOOR LEVEL EMERGENCY AIRSTAIR DOOR LIGHT IAW AMM 33-51-11. OPS CK GOOD. A/C BACK TO SVC.SDR REXA2019082861274Light · inoperativeLH AFT WING ROOT EMERG LIGHT INOP. R&R EMERG LIGHT IAW AMM 33-51-15. OPS CHECK GOOD.SDR REXA2019082831273Intercostal · corrodedDURING REMOTION OF FWD FORMER IN STA. FS= 311.75 AT PASSENGER DOOR INTERNAL ESTRUCTURE RELATED WITH NRC 00369 ]: CORROSION ON INTERCOSTAL DD3 IN STA. FS= 311.75 TO FS= 320.163 AT MAIN ENTRANCE DOOR. (L1) (PTAS) INTERCOSTAL DD3 IN STA. FS= 311.75 TO FS= 320.1SDR REXA2019082831271Intercostal · corrodedAWR; HIDDEN CORROSION: [ DURING REMOTION OF FWD FORMER IN STA. FS= 311.75 AT PASSENGER DOOR INTERNAL ESTRUCTURE RELATED WITH NRC 00369 ]: CORROSION ON INTERCOSTAL DD4 CLEAT IN STA. FS= 311.75 TO FS= 320.163 AT MAIN ENTRANCE DOOR. (L1) (PTAS)
CORROSION LEVEL 2SDR REXA2019082831269Intercostal · corrodedAWR; HIDDEN CORROSION: [ DURING REMOTION OF FWD FORMER IN STA. FS= 311.75 AT PASSENGER DOOR INTERNAL ESTRUCTURE RELATED WITH NRC 00369 ]: CORROSION ON INTERCOSTAL DD7 IN STA. FS= 311.75 TO FS= 320.163 AT MAIN ENTRANCE DOOR. (L1) (PTAS) CORROSION LEVEL 2, INTESDR REXA2019082831268Attach Fitting · corrodedAWR; HIDDEN CORROSION: [ DURING REMOTION OF FWD FORMER IN STA. FS= 311.75 AT PASSENGER DOOR INTERNAL ESTRUCTURE RELATED WITH NRC 00369 ]: CORROSION ON INTERCOSTAL CLEAT BETWEEN INTERCOSTAL DD1 AND DD2 IN STA. FS= 311.75 TO FS= 320.163 AT MAIN ENTRANCE DOOR. (SDR REXA2019082831267Intercostal · corrodedCORROSION ON INTERCOSTAL DD6 AT PASSENGER DOOR INTERNAL ESTRUCTURE. (L1) (TCI 52-10-301)
SUMMARY: CORROSION LEVEL. 2 INTERCOSTAL DD6 WAS REPLACED PER CRJ-900 S.R.M. 51-42-21-001-001-A01 AND 51-42-06-001-001-A01SDR REXA2019081301264Former · corrodedCORROSION ON FORMER, FS 329.41, DD5 AND DD6 AT PASSENGER DOOR INTERNAL STRUCTURE. FORMER FS 329.41 WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01SDR REXA2019082801261Strap · crackedCRACKED STRAP TO ATTACH C CHANNEL IN AFT FAIRING PANEL AT PANEL NBR 196DR. STRAP TO ATTACH C CHANNEL IN AFT FAIRING PANEL AT PANEL NBR 196DR WAS REPAIRED. PER. EA. CRJ953-09525 REV IR.SDR REXA201908281254Stringer · corrodedCORROSION ON STRINGER 27, BS 280 TO 295 IN THE MAIN AVIONICS COMPARTMENT. THE STRINGER WAS REPLACED IAW SRM 51-42-06-001-001-A01 AND SRM 51-42-20-001-001-A01.SDR REXA2019082891252Intercostal · corrodedCORROSION ON LEFT INTERCOSTAL (1 EA) IN STA. FS= 349 TO FS= 364 NEAR STGR 27 AT MAIN AVIONICS COMPARTMENT. ( LEFT INTERCOSTAL (1 EA) IN STA. FS= 349 TO FS= 364 NEAR STGR 27 AT MAIN AVIONICS COMPARTMENT WAS REPLACED PER SRM. 51-42-06-001-001-A01 PAR.6.D. AND SSDR REXA201908281265Support Plate · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
LEVEL CORROSION 2. PROTECTION PLATE SUPPORT IN STA. FS= 339 BETWEEN 41SDR REXA201908281263Support · corrodedCORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 322 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY: PROTECTION PLATE SUPPORT WAS REPLACED PER CRJ-900 SRM 51-42-06-001-001-A01 PAR 6DSDR REXA201908281262Web · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 346 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY: LEVEL CORROSION 2. PROTECTION PLATE SUPPORT IN STA. FS= 346 BETSDR REXA201908281260Web · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 329 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY: PROTECTION PLATE SUPPORT WAS REPLACED PER CRJ-900 SRM 51-42-06-SDR REXA2019082871259Angle · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON SUPORT MOUNTING ANGLE IN STA. FS= 319 TO FS= 349 AND 41RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY: MOUNTING ANGLE SUPPORT WAS REPLACED PER. CRJ-900 SRM 51-42-06-001-00SDR REXA2019082871258Floorbeam · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY: ANGLE WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01SDR REXA2019080701257Floorbeam · corroded[ IN REFERENCE NRC S/N 144 ] INITIAL INSPECTION: CORROSION ON FLOOR SUPPORT IN STA. FS= 280 BETWEEN STRG 26LH TO 26RH AT MAIN AVIONICS COMPARTMENT. (E/E) [ TASK 900-53-140-300 APPENDIX A ] TCI: 100-09, 100-09E4, 100-09E5
SUMMARY: LEVEL CORROSION 2. FLOOR SUPPSDR REXA2019082871256Floorbeam · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 322 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY:ANGLE WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01SDR REXA2019082871255Floorbeam · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 346 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY::ANGLE WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01SDR REXA2019082871253Support Angle · corrodedCORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 329 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY::ANGLE WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01SDR REXA2019082861266Stringer Splice · corroded[ IN REFERENCE NRC S/N 144 ]: INITIAL INSPECTION: CORROSION ON STRINGER SPLICE 25RH IN STA. FS= 327 TO FS= 337 AT MAIN AVIONICS COMPARTMENT. (E/E) [ TASK 900-53-140-300 APPENDIX A ] TCI: 100-09, 100-09E4, 100-09E5
LEVEL CORROSION 2. STRINGER SPLICE 25RH IN STSDR REXA2019082861251Stringer · corroded[ IN REFERENCE NRC S/N 144 ]: INITIAL INSPECTION: CORROSION ON STRINGER 25RH IN STA. FS280 TO FS295 AT MAIN AVIONICS COMPARTMENT. (E/E) [ TASK 900-53-140-300 APPENDIX A ] TCI: 100-09, 100-09E4, 100-09E5
LEVEL CORROSION 2. STRINGER 25RH IN STA. FS280 TO FS295 SDR REXA2019080501270Intercostal · corrodedAWR; HIDDEN CORROSION: [ DURING REMOTION OF FWD FORMER IN STA. FS= 311.75 AT PASSENGER DOOR INTERNAL ESTRUCTURE RELATED WITH NRC 00369 ]: CORROSION ON INTERCOSTAL DD6 CLEAT IN STA. FS= 320.163 AT MAIN ENTRANCE DOOR. (L1) (PTAS). CORROSION LEVEL 2, INTERCOSTALSDR REXA2019082841272Intercostal · corrodedDURING REMOTION OF FWD FORMER IN STA. FS= 311.75 AT PASSENGER DOOR INTERNAL ESTRUCTURE RELATED WITH NRC 00369 ]: CORROSION ON INTERCOSTAL DD7 CLIP IN STA. FS= 311.75 AT MAIN ENTRANCE DOOR. (L1) (PTAS) CORROSION LEVEL 2, INTERCOSTAL DD7 CLIP IN STA. FS= 311.75SDR REXA2019072301128Light · inoperativeGALLEY EMERGENCY LIGHTS INOPERATIVE. REPLACED BULBS IAW AMM 33-51-05. OPS CHECK GOOD. PN#ON/OFF: OL3071.SDR REXA2018091300823Door · brokenAFTER TAKEOFF WITH GEAR RETRACTION WE GOT A GEAR DISAGREE WARNING MESSAGE NOSE GEAR RED INDICATION. PERFORMED GEAR EXTENSION/ RETRACTION IAW AMM 32-30-00. UPON RETRACTION FOUND NLG REAR DOOR HAD BROKEN OFF ITS HINGES. REMOVED DOOR AND PROCEDED WITH THE OPERATISDR REXA2018090700803Oxygen Mask · brokenFO SIDE O2 MASK RED TAB BROKE OFF. SWAPPED F/O O2 MASK WITH OBSERVERS O2 MASK. PERFORMED OPS & LEAK CHECK OF CREW OXYGEN SYSTEM & CREW O2 MASK MICROPHONE IAW AMM 35-10-00 & 23-51-00 OPS CHECK GOOD. REMOVE OBSERVER O2 FULL FACE MASK IAW AMM 35-11-12-000-801, INSDR REXA2018083000763Light · inoperativeOVERHEAD EMERGENCY LIGHTS OVER FIRST CLASS ARE INOP, AFTER FIRST CLASS EVERY OTHER LIGHT IS INOP. TROUBLESHOT OVERHEAD EMERGENCY LIGHTS IAW WMM 25-28-01. FOUND PUSHED BACK PIN AT CONNECTOR P5439 PIN K. RESEATED PIN K IAW ESPM 20-24-00. OPERATIONAL TEST OF EMERSDR REXA2018010200003Lens · looseFA REPORTED THE EXIT SIGN OVER ROW 12 HAD FALLEN OFF OF THE CELILING. SECURED THE SIGN COVER IAW AMM 33-51-07. ACFT OK FOR SERVICE.SDR REXA2017120601227Oxygen Mask · failedOBSERVER'S OXYGEN MASK TEST BUTTON DONT TEST.
DEFERRING OBSERVER'S OXYGEN SYSTEM IAW CRJ 900 MEL 35-10-1. MM02 UPDAT
ED PLACARD INSTALLED. MOC NOTIFIED. # 96074 CAT""A""***R/R OBS O2 MASK
STOWAGE BOX IAW AMM 35-11-15. OPS+LEAK CHECK GOOD. THIS CLEARS MEL SDR REXA2017112901209Oxygen Mask · malfunctionedCAPTAIN`S OXYGEN MASK WILL NOT INFLATE. SWAPPED OBSERVER`S AND CAPTAIN`S OXYGEN MASKS IAW AMM 35-11-12. REMOVED AND REPLACED THE OBSERVER`S OXYGEN MASK IAW AMM 35-10-00. OPS CHECKED GOOD.SDR REXA2017111401178Light · inoperativeLT OVERWING FWD EMERGENCY LIGHT & RT OVERWING AFT EMERGENCY LIGHT DO NOT ILLUMINATE. REPLACED LT FWD EMER LIGHT ASSY & RT AFT EMER LIGHT ASSY PER AMM 33-51-15-400-801.SDR REXA2017082900962Warning Message · false activationAFTER TAKEOFF, HAD A WARNING GEAR DISAGREE. THE NOSEWHEEL DID NOT RETRACT. DIVERTED. PERFORMED TORQUE OF NLG AFT DOOR DRIVE BRACKET HARDWARE IAW JC 900-32-710-900. VERIFIED RIGGING OF PX37 IAW AMM 32-61-05 FOR NOSE GEAR CENTER SENSOR. ALL CHECKED NORMAL. SDR REXA2017081900894Coffeemaker · odorLEFT COFFEE MAKER GIVES OFF A BURNING SMELL WHEN TRYING TO BREW & LEAKS WATER FROM UNDER THE HOT PLATE BASE. PERFORMED OPS CHECK OF THE NR 1 COFFEEMAKER IAW AMM 25-32-06. OPS CHECKED GOOD. NO LEAKS FOUNDSDR REXA2017080600860Seal · brokenGREEN PLASTIC SEAL ON AFT PBE BROKEN. RESEALED THE AFT PBE IAW 25-16-00.SDR REXA2017060500651Sensor · inoperativeWHILE CLIMBING OUT THROUGH 150' BRAKE OVERHEAT WARNING ILLUMINATED. COMPLETED QRH. BRAKE TEMP ON LEFT OUTBOARD WAS RED AT 18 AND VERY IRRATIC NUMBERS.AFTER COMPLETION OF QRH WARNING WENT AWAY ALL INDICATIONS NORMAL. CONTINUED CLIMB THROUGH FL210' AND BRAKE OVHSDR REXA2017050400570Warning Message · false activationTHE LANDING GEAR DID NOT RETRACT (ALL 3) AND RECIEVED A GEAR DISAGREE WARNING MESSAGE. IAW QRH, THE GEAR HANDLE WAS PUT BACK IN THE DOWN POSITION AND THE GEAR INDICATION REMAINED, 3 GREEN. AFTER EXTENSIVE VECTORING FOR CHECKLISTS, MADE A NORMAL LANDING, TAXSDR REXA2017030300320Defibrillator · malfunctionedAED SHOWS SOLID RED BATTERY INDICATION. REMOVED & REPLACED THE AED.SDR REXA2017021400194Battery Pack · dischargedMAIN CABIN DOOR FLASHLIGHT IS NOT CHARGED. INSTALLED A NEW BATTERY PACK IN MAIN CABIN DOOR EMERGENCY FLASHLIGHT IAW AMM 25-60-00. OPS TEST GOOD.SDR REXA2017012600123Oxygen Mask · failedFO O2 MASK IS NOT WORKING PROPERLY ON THE TEST. DEFERRED OBSERVER'S OXYGEN SYS IAW MEL 35-10-1. R&R OBS O2 MASK IAW AMM 35-11-12. OPS CHECK PASSED.SDR REXA2016073101431Oxygen Mask · failedTHIRD FLIGHT ATTENDANT MASK DID NOT DEPLOY DURING AUTO-DEPLOY EVENT. REMOVED AND REPLACED OXYGEN IAW 35-20-00. CHECKED GOODSDR REXA2016073101430Oxygen Mask · unwanted deployON FINAL APPROACH, O2 PASS OXY ON MST CAUTION LIGHT ON AND OXYGEN MASKS DEPLOYED. RESTOWED AND CLEANED THE PAX OXYGEN MASK IAW 35-21-09 ALL CHECKED GOOD. REPLACED PIN IAW ESPM 20-16-00. R & R PCB4 IN JB10 IAW 24-05-09 ALL CHECKED GOOD. R & R CPCP IAW 21SDR REXA2016042700656Light · unsecureRIGHT SIDE FLOOR LIGHTING IN FRONT OF GALLEY CARTS NEED FASTENING TO FLOOR. SECURED FLOOR LIGHTING STRIP TO THE FLOOR IN THE RT SIDE OF THE GALLEY.SDR REXA2016040300548Cover · crackedFORWARD RT EMER TRACK COVER IS CRACKED & FILM FILLER STRIP IS MISSING PART. R & R FWD RT EMER TRACK COVER & FILM FILLER STRIP IAW AMM 33-51-01-400-801-A21.SDR REXA2016040300547Battery · dischargedLEFT & RIGHT FLIGHT DECK EMER FLASHLIGHTS ARE INOPERATIVE. REPLACED LT & RT FLIGHT DECK EMER FLASHLIGHT BATTERIES IAW CMM 25-60-02.
Back to N924XJ